| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
6e0ed89d3f |
Make UANodeSetSerializers.g.cs generation deterministic (#4252)
## Problem
Regenerating `src/Opc.Ua.Types/Schema/UANodeSetSerializers.g.cs` via
`UANodeSetSerializers.ps1` produced ~144 lines of no-op churn on every
run. The sgen tool (Microsoft.XmlSerializer.Generator) emits the Reader
`idNN_Name` field declarations and the matching `InitIDs()` initializers
in a hash-seed-dependent order: the assigned id numbers are stable, but
their emission order shuffles between runs. This made an otherwise no-op
regeneration produce a large, noisy diff that was painful to review.
## Fix
- Added a canonicalization pass in `UANodeSetSerializers.ps1` that sorts
each of the two affected contiguous blocks (the `string idNN_Name;`
field declarations and the `idNN_Name = Reader.NameTable.Add(...)`
initializers) by numeric id ascending, so re-running on unchanged input
yields byte-identical output.
- The name regex was widened to `@"[^"]*"` so entries with an empty name
(e.g. `id3_Item`) or URI-style names do not split the block into
independently-sorted runs (which would keep it unstable).
- Regenerated the committed `.g.cs` once through the improved script;
the resulting diff is sort-only.
## Also fixed: tool download
Replaced `Expand-Archive` (which rejects the `.nupkg` extension on
Windows PowerShell) with
`System.IO.Compression.ZipFile.ExtractToDirectory`, so a clean run with
an empty tool cache works end-to-end on both Windows PowerShell 5.1 and
PowerShell 7+.
## Validation
- From an empty tool cache, the full download + extract + generate path
succeeds.
- A second run is a byte-identical no-op (`git diff --exit-code` = 0).
- `dotnet build src\Opc.Ua.Types\Opc.Ua.Types.csproj -c Release -f
net10.0` builds with 0 warnings and 0 errors.
- All AOT post-processing is preserved: custom header, `#if
NET5_0_OR_GREATER` wrapper, module IL2026/IL3050 suppressions,
`[RequiresUnreferencedCode]`/`[RequiresDynamicCode]` on the
InitCallbacks() overrides (Writer = RequiresUnreferencedCode only,
Reader = both), pragmas, UTF-8 BOM, and CRLF line endings.
No hand-edits to `.g.cs`; the fix lives entirely in the script so future
regenerations stay stable.
## Also: Load UserAccessLevel from NodeSet2 model
Bundled here because it regenerates `UANodeSetSerializers.g.cs`, which
this PR owns.
- `UANodeSet.cs`: adds the `{Member}Specified` XmlSerializer convention
to `UAVariable.UserAccessLevel` (new `UserAccessLevelSpecified`
companion; removed the `[DefaultValue((uint)1)]`) so an
explicitly-present `UserAccessLevel` attribute is distinguishable from
the schema default of 1.
- `UANodeSetSerializers.g.cs`: regenerated - the writer now emits
`UserAccessLevel` when `UserAccessLevelSpecified`, and the reader sets
`UserAccessLevelSpecified = true`. Regenerating produced only these two
behavioral changes plus removal of pre-existing empty `if
(o.@MemberSpecified) { }` no-op blocks (see below); no `idNN` re-sort,
so determinism held.
- `UANodeSetHelpers.cs`: the runtime importer honors an
explicitly-specified `UserAccessLevel` instead of always deriving it
from `AccessLevel`.
- Source generator (`ModelDesign.cs` `RawUserAccessLevel`,
`ModelDesignExtensions.GetUserAccessLevelAsCode`,
`NodeSetToModelDesign.cs`): emit the verbatim `UserAccessLevel` when the
NodeSet sets it, otherwise derive from `AccessLevel` (matching the
runtime importer).
### Generator normalization for `{Member}Specified`
sgen emits an extra empty `if (o.@MemberSpecified) { }` no-op block near
`WriteEndElement` for every member that uses the `{Member}Specified`
convention. Adding the companion to `UserAccessLevel` would have
introduced one such block, and the committed file already contained
several for other members (`LastModified`, `AccessRestrictions`,
`PublicationDate`). `UANodeSetSerializers.ps1` now strips these empty
guard blocks during post-processing, so the generated file stays free of
dead code and a re-run of the generator remains a byte-identical no-op.
The real, non-empty guard around the `WriteAttribute` call is preserved.
The ReferenceServer sample application of this feature is intentionally
excluded and lands with #4220.
### Validation (UserAccessLevel)
- `dotnet build src\Opc.Ua.Types\Opc.Ua.Types.csproj -c Release -f
net10.0` and `dotnet build
tools\Opc.Ua.SourceGeneration.Core\Opc.Ua.SourceGeneration.Core.csproj
-c Release`: both 0 warnings / 0 errors.
- `dotnet test tests\Opc.Ua.SourceGeneration.Core.Tests -c Release -f
net8.0 --filter
"FullyQualifiedName~NodeSetToModelDesign|FullyQualifiedName~UserAccessLevel"`:
16 passed, 0 failed.
- Re-running the generator remains a byte-identical no-op.
---------
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com>
Co-authored-by: romanett <7413710+romanett@users.noreply.github.com>
|
||
|
|
8a10139b8c |
Fix OPC UA address-space compliance in the device integration stack (#4117)
# Description
A live OPC UA compliance audit of `samples/PumpDeviceIntegrationServer`
against the **OPC 40223 Pumps** and **OPC 10000-100 (DI)** companion
specifications found **13 address-space violations** plus a
serialization bug in the MCP tool. Every fix lands at its **root cause
in the shared stack** rather than as a workaround in the sample, so all
servers benefit.
The sample now exposes **N fully simulated pumps** (`--pumps N`) and
advertises the DI conformance facets it actually satisfies.
> This branch has been merged with `master` including **#4116** ("Add
simulation to PumpDeviceIntegrationServer and Event modelling"), which
independently reworked the same pump simulation and the same fluent
alarm builders. See [Relationship to #4116](#relationship-to-4116) below
for how the two were reconciled.
## Findings and fixes
| # | Finding | Root cause | Fix |
|---|---------|-----------|-----|
| 1 | `OverTempAlarm` created by the fluent API did not exist in the
address space | `AttachAlarm` attached the alarm with `AddChild` but
never indexed it into the node manager | Register the node; the same gap
existed in `AddObject`, `CreateInstance` and the state-machine creators
|
| 2 | Alarms were unsubscribable — `EventNotifier = 0` everywhere, no
`HasNotifier` from `Server` | No event-source wiring at all | Set
`HasCondition`, initialise
`SourceNode`/`SourceName`/`ConditionName`/`InputNode`, promote
`EventNotifier` up the ancestor chain, publish `HasNotifier` from the
`Server` object |
| 3 | Every instance NodeId was minted in the **DI standard namespace**
(`ns=4;s=5001_Pump #1`) | `DiNodeManager.New` inherited the parent's
namespace index | New `DiNodeManager.InstanceNamespaceIndex`; instances
move to the server's application namespace |
| 4 | `Server/Namespaces` described only 2 of 6 namespaces | The
NodeSet2 importer drops nodes parented to namespace 0, so companion-spec
metadata objects never reached the address space — and no route covered
the server's own namespace | New `NamespaceMetadataPublisher` walks the
`NamespaceArray` and fills version/publication date from
`ModelDependencyAttribute` |
| 5 | Vendor BrowseNames (`Diagnostics`, `LastError`, …) sat in the DI
namespace | Builders defaulted to the parent's namespace | Default to
the server namespace; **spec-defined BrowseNames are unchanged** |
| 6 | `AccessLevel="5"` from the Pumps NodeSet was reported as `1` | The
ModelDesign `AccessLevel` enum is not `[Flags]` and cannot represent
`CurrentRead \| HistoryRead` | Carry the verbatim NodeSet2 bitmask and
emit named `AccessLevels` constants |
| 7 | `Historizing = true` while `HistoryRead` returned
`BadHistoryOperationUnsupported` | Nothing reconciled the declared
history surface with the wired historians | Startup clears the
advertisement (including masking the attribute read callbacks) when no
provider resolves; the sample wires a real historian |
| 8 | Mandatory `ProductInstanceUri` unset | Sample omission | Populated
on every pump |
| 9 | Mandatory `TrueState`/`FalseState` empty on every supervision
boolean | Absent in the official NodeSet; a server must still populate
them | Populated on every pump |
| 10 | Machinery `Machines` folder empty (OPC 40001-1 §9.2 says
**shall**) | `TryAddToMachinesFolder` used `AddChild`, which
*re-parents* the device away from `DeviceSet` | Add the `Organizes`
reference instead |
| 11 | BrowseName contained a space and `#` | Sample naming | `Pump_1`
with the readable label in `DisplayName` |
| 12 | `Maintenance` group materialised but empty | Sample omission |
Populated |
| 13 | Uninitialised values reported `Good` | No initial-value status |
`BadWaitingForInitialData` until the first simulation tick |
| — | `ServerProfileArray` advertised only `StandardUA2017` |
`DiNodeManager` did not implement the existing `IConformanceContributor`
| Contribute DI 1.05 server facets computed at runtime from what is
actually wired, merged with `StandardUA2017` |
| — | MCP tool serialised boolean `false` and numeric `0` as JSON `null`
| `Variant.Null` is `default`, so `Variant.Equals` adopts the non-null
type and compares against the default value | Dispatch on `BuiltInType`
and use typed `TryGetValue` accessors instead of the prohibited
`AsBoxedObject` |
## Relationship to #4116
#4116 landed on `master` while this branch was in flight and targeted
overlapping ground. The merge is a **union of both intents**, not a
fast-forward:
- **`AlarmBuilderExtensions`** — kept both sides. #4116 contributes the
parent-must-be-an-Object guard, `SetEnableState`, and the
`HasEventSource` references; this branch contributes the `HasCondition`
reference, condition source initialisation, **registration of the alarm
with the node manager so it is browsable**, notifier promotion up the
whole ancestor chain, and root-notifier registration.
- **`SupervisionBuilderExtensions`** — took #4116's `SetAlarmActive`. It
is more spec-correct than this branch's version: it honours
`EnabledState`, resets Acked/Confirmed on activation, and computes
`Retain` per OPC 10000-9 so an unacknowledged Condition stays retained
after going inactive. This branch's null guard was kept so a malformed
alarm cannot dereference a missing `EnabledState`.
- **`PumpNodeManager.Configure.cs`** — took #4116's **push-based**
simulation (`RegisterPumpSimulation`, `CreatePumpSimulation`,
`IValueUpdater<T>`, `Initialize`/`Advance`/`Publish`, deterministic
per-pump phase offsets) as the structure, then folded in this branch's
compliance work: configurable pump count, Maintenance group,
`TrueState`/`FalseState`, historian wiring, per-pump mandatory
Identification values, and `BadWaitingForInitialData` until the first
tick.
- **README** — union, keeping #4116's address-space validation workflow
section.
Two test adjustments were needed, both because the merge legitimately
changed behaviour the tests pinned:
- `PumpHostedReferenceTests` now resolves pump NodeIds from the browse
result instead of hard-coding the DI namespace, and waits for the first
published value. `PumpCreatedAfterStartupJoinsTheLiveSimulationAsync`
was **added** to restore #4116's coverage that a pump created after
startup through `ConfigureDevicesFor` joins the live simulation.
- `FluentAlarmRegistrationIntegrationTests` no longer asserts that
`Retain` clears when an alarm goes inactive — that pinned this branch's
weaker semantics, and #4116's Part 9 behaviour is correct.
## Breaking change
Runtime-created DI device instance NodeIds move from the companion-spec
namespace to the server's application namespace, e.g.
`ns=<DI>;s=5001_Pump #1` becomes `ns=<application>;s=5001_Pump #1`. This
invalidates NodeIds cached by clients from earlier 2.0 previews. It is
**not** a model change — standard DI/Machinery/Pumps type NodeIds and
spec-defined BrowseNames are untouched.
Device integration hosting is new in 2.0, so there is nothing to migrate
from 1.5.378 and this is deliberately *not* in `docs/MigrationGuide.md`.
Anyone tracking 2.0 previews should rediscover devices by browsing
`DeviceSet` rather than persisting NodeIds, and resolve namespace
indexes from `NamespaceArray` per connection.
## Verification
Compliance is pinned by regression tests that assert **through the
server's service surface** (`BrowseAsync` / `ReadAsync` /
`HistoryReadAsync`), not by inspecting `NodeState` objects in memory.
That distinction mattered: three defects survived in-memory assertions
and were only caught through the read path — most subtly, `Historizing`
was cleared while `AccessLevel` still advertised `HistoryRead`, because
attribute read callbacks re-applied the NodeSet bits.
Post-merge on net10.0:
| Suite | Result |
|---|---|
| `Opc.Ua.Di.Tests` | 326 passed |
| `Opc.Ua.Server.Tests` | 3846 passed, 5 skipped |
| `Opc.Ua.Tools.Tests` | 288 passed |
| `Opc.Ua.History.Tests` | 506 passed, 27 skipped |
| `Opc.Ua.SourceGeneration.Core.Tests` | 3722 passed, 8 skipped |
The full solution was also built and tested on **net48** before the
merge.
Review feedback from `copilot-pull-request-reviewer` has been addressed
in commit `badad31dc`: the shared `ServerObjectState` lock was removed
(the forward `HasNotifier` edge is published through the owning node
manager instead), MCP array serialization now preserves element types,
and the pump option guards report the specific rejected option. The only
failure is
`ConfigureApplicationBuildsSharedClientAndServerConfigurationAsync`, a
pre-existing certificate-store issue that **passes when run in
isolation** and is unrelated to this change.
## Documentation
Updated `docs/DeviceIntegration.md`, `docs/MigrationGuide.md`,
`docs/HistoricalAccess.md`, `docs/DeveloperGuide.md`,
`docs/McpServer.md`, `docs/README.md`,
`samples/PumpDeviceIntegrationServer/README.md` and
`tools/Opc.Ua.Mcp/README.md`, and consolidated the four node-manager
documents into a single [`docs/NodeManagers.md`](docs/NodeManagers.md) —
overview, built-in managers (including `MasterNodeManager`), core vs
custom, registration, server address-space metadata, and source
generation — with a TOC and all inbound links repointed.
## Related Issues
No tracking issue exists for this work yet — it originated from an
ad-hoc compliance audit of the pump sample. Given the size of the change
and the runtime-breaking NodeId move, please open (or link) a tracking
issue so the design is recorded as an ADR before merging.
- Fixes #
## Checklist
_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._
- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [x] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.
---------
Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Copilot-Session: 0d50c3fc-58b1-4c99-85a4-1e32c88666d9
|
||
|
|
7cec2d614d | Move repository files to the consolidated layout |