Machinery client: return the NodeId of each metering point measurement (#4642)
# Description `MachineryMeasurementValue` gets an additive init-only `NodeId`; the positional constructor is unchanged. `ReadMeteringPointAsync` fills it, and so do `ReadMainMeteringPointAsync` and `ReadSubMetersAsync`, which use it. The values are now read by the NodeIds the browse returned, in one batched Read, instead of translating each browse name back to a NodeId first. That is one round trip less, and value and NodeId come from the same node. `docs/Machinery.md` shows how to subscribe to the measurements. Tests: - New end-to-end test `MeteringPointMeasurementsCarryTheNodeIdOfTheirVariableAsync` against `MachineryIntegrationServer`, covering the main metering point and the sub-meter. It reads `BrowseName` and `Value` behind every returned NodeId. It fails on master. - `Opc.Ua.Machinery.Tests` 165/165 on net10.0; all target frameworks build with 0 warnings. - Fork CI (full matrix incl. macOS) and CodeQL: green on `afa00065a` (the same change on master `ce88955f7`) — [CI run 36826789991](https://github.com/biancode/UA-.NETStandard/actions/runs/36826789991) (189 jobs), [CodeQL run 36826793071](https://github.com/biancode/UA-.NETStandard/actions/runs/36826793071). Rebasing onto master with #4607 needed one conflict resolution in `MachineryEndToEndTests.cs` (both new tests kept); `Opc.Ua.Machinery.Tests` passes 165/165 on net10.0 locally afterwards and CodeQL is green on that state ([run 36979020583](https://github.com/biancode/UA-.NETStandard/actions/runs/36979020583)). The run on the current head is in progress: [CI run 37016200389](https://github.com/biancode/UA-.NETStandard/actions/runs/37016200389). ## Related Issues - Fixes #4641 ## Checklist - [x] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. (Affected suites on net10.0 and net8.0 locally on macOS; .NET Framework is covered by the fork CI's Windows net48 legs.) - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. |
||
|
|
01d6b5d26c |
Machinery: the OPC 40001 companion SDK with Jobs, Result Transfer, Process Values and Energy (#4578)
> Tracking issue #4576. #4577 is merged, so this branch is rebased onto > `master` and contains only the Machinery commits. ## Summary Second of four stacked PRs. Adds the OPC UA for Machinery series as model packages plus a server and a client SDK, following the companion pattern of DI and Robotics, and the two models it depends on that the repository does not carry yet. | Package | Content | |---|---| | `Opc.Ua.IA` | OPC 10000-200 IA 1.01.4, **moved out of `Opc.Ua.Robotics`** (see below) | | `Opc.Ua.ECM` | OPC 34100 Energy Consumption Management 1.0.1 | | `Opc.Ua.PADIM` | OPC 30081 PA-DIM 1.02.0 with the IRDI dictionary | | `Opc.Ua.Machinery` | OPC 40001-1 Basic Building Blocks 1.04.1 | | `Opc.Ua.Machinery.ProcessValues` | OPC 40001-2 Process Values 1.00.0 | | `Opc.Ua.Machinery.Jobs` | OPC 40001-3 Job Management 1.0.1 | | `Opc.Ua.Machinery.Energy` | OPC 40001-4 Energy 1.00 | | `Opc.Ua.Machinery.Result` | OPC 40001-101 Result Transfer 1.01.0 | | `Opc.Ua.Machinery.Server` | `AddMachinery()` / `ConfigureMachinery(...)`, fluent machine builder, server-driven state machines, process values, job management over the shared ISA-95 V2 binder, energy, result management incl. `GenerateFileForRead` | | `Opc.Ua.Machinery.Client` | machine discovery, identification, state observation, process values, job and result access | OPC 40001-101 `ResultTransferType` redeclares `GenerateFileForRead` with its own arguments; the generator fix for such overrides, merged with #4577, is what makes it appear on the `ResultTransfer` instances. All NodeSets are byte-identical to `UA-Nodeset/latest`. Each model carries a pinned `Model/*.NodeIds.csv` the generator validates, next to the unmodified upstream table; `tools/nodesets/derive-identifier-table.py` derives the former from the latter. ## Changes to existing code - **IA moves out of Robotics.** Machinery needs IA as well (OPC 40001-1 types `Stacklight` with `BasicStacklightType`), and two assemblies generating the same model under the same prefix collide at any consumer referencing both. The NodeSet moves verbatim, so no generated type changes; the prefix stays `Opc.Ua.IA`. Source-compatible, but IA types now live in `Opc.Ua.IA.dll` rather than `Opc.Ua.Robotics.dll` — binary-breaking for consumers of the Robotics package. - **`samples/OpenUsd/GeneratorServer`** drops its hand-reduced Machinery NodeSet copy and the script that produced it (a workaround for the generator defect fixed by #4577) and references `Opc.Ua.Machinery` instead. - `README.md` and `docs/README.md` list the new models; the README also corrects the Industrial Automation entry (Part 200, not OPC 40001-1). ## Review follow-ups Separate commits after the docs/samples commit, so the reviewed state stays comparable. Each fix comes with a test that fails without it. - Copilot review: a transition is committed only while the state machine is still in its source state; optional Jobs/Result namespaces the server does not load are reported as absent, as documented; resources of registered machines (result transfer, job-management change pumps) are released with the node manager (`DisposeMachineryResourcesAsync` for a custom DI manager); `NodeId`/`LocalizedText` use their null sentinels instead of `Nullable<T>`. - Own review with the rubric in `.github/copilot-instructions.md`: a failed browse call propagates from the client instead of reading as "no children"; the predefined result metadata compares `CreationTime` against the `DateTimeUtc` sentinels (the `DateTime` conversion shifted `DateTime.MaxValue` by the host's UTC offset); process values below `Monitoring` are found; a second metering point named `Main` is rejected; the zero-point event is reported when the handler throws; smaller state-sharing and documentation corrections. ## Testing - `tests/Opc.Ua.Machinery.Tests`: 162 tests on net8 and net10 and with the netstandard2.1 libraries; the integration tests connect a real client session over `opc.tcp` to a hosted server. - With IA extracted: Robotics 636, OpenUsd 921, DI 433 and SourceGeneration 263 tests pass. - `UA.slnx` builds for net472, net48, netstandard2.0/2.1 and net8/9/10 with SDK 10.0.401 and no warnings. - Changed-line coverage of this layer (`check-coverage.ps1`): 91.68 % (6059 of 6609 changed lines, against `master`). - Fork CI, full PR matrix incl. macOS, on the current master: green, all 184 jobs ([run 36582685653](https://github.com/biancode/UA-.NETStandard/actions/runs/36582685653)). CodeQL: green ([run 36582689589](https://github.com/biancode/UA-.NETStandard/actions/runs/36582689589)). - Beyond the in-repo tests the implementation has been validated end to end against a separate, non-public OPC UA client and server. ## Reviewing Commits are ordered so each builds: IA extraction → identifier-table tool → ECM/PA-DIM → Machinery models → server → client → tests → docs/samples → GeneratorServer sample → review follow-ups. The model commits are large only because of the NodeSets and identifier tables; the hand-written code starts at the server commit. --------- Co-authored-by: Marc Schier <marcschier@users.noreply.github.com> |