romanett cce2004fdd CTT: keep GeneratesEvent off Object instances and Views off non-hierarchical references; classify Deadband Err-006 as CTT defect (#4667)
# Description

Three findings from the 2026-10-03 CTT run with the patched 1.05.513
scripts. Two are server/model defects and are fixed here. The third is a
CTT script defect, recorded as C56 in `plans/ctt-issues.md`.

## 1. Monitored Items Deadband Filter `Err-006.js`: CTT defect (C56, no
server change)

The script modifies a MonitoredItem on the first static numeric scalar
(a plain BaseDataVariable with no EURange) to use a PercentDeadband. It
accepts only `Good` or `Bad_MonitoredItemFilterUnsupported`. Since #4629
the server returns `Bad_DeadbandFilterInvalid`, and that is the code the
spec defines for this case:

- OPC 10000-8 §7.2: PercentDeadband "applies only to AnalogItems with an
EURange Property".
- OPC 10000-8 §7.3.2 Table 61: `Bad_DeadbandFilterInvalid` is returned
when "a PercentDeadband is not supported, since an EURange is not
configured".

CreateMonitoredItems and ModifyMonitoredItems both go through
`ValidateMonitoringFilterAsync` and return the same code. Monitor Basic
`Err-022.js` already accepts `Bad_FilterNotAllowed` for non-analog
items, so the scripts disagree with each other here.

Draft Mantis note (not filed yet):

> **Monitored Items Deadband Filter Err-006.js rejects
Bad_DeadbandFilterInvalid for a PercentDeadband on a node without
EURange**
> Err-006.js picks the first node of `/Server Test/NodeIds/Static/All
Profiles/Scalar/NumericSettings`, which is normally a BaseDataVariable
without an EURange. It then calls ModifyMonitoredItems with a
PercentDeadband (10 %) and accepts only Good or
Bad_MonitoredItemFilterUnsupported. OPC 10000-8 §7.2 limits
PercentDeadband to AnalogItems with an EURange. §7.3.2 Table 61 defines
Bad_DeadbandFilterInvalid for "a PercentDeadband is not supported, since
an EURange is not configured", so a compliant server fails this test.
Monitor Basic Err-022.js already accepts Bad_FilterNotAllowed for the
non-analog fallback.
> Proposed fix: add StatusCode.BadDeadbandFilterInvalid (and, consistent
with Err-022.js, StatusCode.BadFilterNotAllowed) to the
ExpectedAndAcceptedResults of the ModifyMonitoredItems call.

## 2. GeneratesEvent on Objects (Base Info Core Structure 2 `001.js`):
source generator defect

The CTT reported `ns=9;i=234` (the `<ServiceName>` placeholder of
AuthorizationServicesFolderType) and
`ns=9;s=AuthorizationServices/Default` as Objects that are the source of
GeneratesEvent references. OPC 10000-3 §7.15 says: "The SourceNode of
References of this type shall be an ObjectType, a VariableType or a
Method".

`OpcUaGdsModel.xml` declares both references
(AccessTokenRequested/Issued audit events) correctly, on
`AuthorizationServiceType`. The source generator copied the type's own
non-hierarchical references onto every Object or Variable built from the
type: onto instance declarations (the placeholder) and into
`CreateInstanceOf<Type>`, which `AuthorizationServiceState` initialises
from, and that is how the `Default` service gets them. UA-ModelCompiler
does the same thing, so the official `Opc.Ua.Gds.NodeSet2.xml` in
UA-Nodeset has the same two references on `ns=1;i=234`.

Fix:
- `TranslateReferences` now marks references declared on a type
(`HierarchyReference.DefinedOnType`, which already existed but was never
set).
- `NodeStateGenerator.GetReferences` drops forward GeneratesEvent
references (including subtypes such as AlwaysGeneratesEvent) for Object
and Variable nodes when the reference came from the type.
- ObjectTypes, VariableTypes and Methods keep these references. For
example, the RegisterApplication methods and the Acknowledge/AddComment
methods of the alarm types are unchanged.
- References that a model declares explicitly on an instance are emitted
as before.

## 3. View targeted by HasCause/HasEffect (Base Info Core Structure 2
`001.js`): sample model defect

#4485 added `Views_Operations HasCause/HasEffect Views_Engineering` so
that View Minimum Continuation Point 01 `012.js` and View Basic 2
`018.js` have at least two references to View nodes on the configured
View (`/Server Test/NodeIds/NodeClasses/View` = `Views_Operations`). OPC
10000-3 §5.4 says Views "can be the SourceNode of any hierarchical
Reference. They shall not be the SourceNode of any NonHierarchical
Reference."

`Views_Operations` now Organizes `Views_Engineering` and a new View,
`Views_Maintenance`, which organizes `DataAccess`. This keeps two
View-class references and adds no loops (ContainsNoLoops stays true).

## Tests
-
`NodeStateGeneratorTests.TypeGeneratesEventReferencesAreNotCopiedToObjectInstances`:
covers the type, the placeholder, the instance, `CreateInstanceOf`,
Methods and an explicit instance reference. It fails without the fix.
- `ReferenceServerTest.SampleViewsHaveNoNonHierarchicalReferencesAsync`.
The existing `NodeClassSampleNodesReferenceTheirOwnNodeClassAsync` still
passes.
- Results with net10.0:
  - SourceGeneration.Core.Tests: 4267 passed, 0 failed
  - InformationModel.Tests: 1078 passed, 0 failed
  - Di.Tests, including RobotOpenUsdE2e: 438 passed, 0 failed
  - OpenUsd.Tests: 921 passed, 0 failed
  - Server.Tests `ReferenceServerTest`: 56 passed, 0 failed
- `UA.slnx` builds with net10.0. The changed test projects build with
net48.

## CTT (patched 1.05.513 scripts, compared with the 2026-10-03 patched
baseline)

| Part | Change |
| --- | --- |
| p02-base-info | Base Info Core Structure 2 `001.js`: Error → Skipped.
The GeneratesEvent and View errors are gone; the remaining skips are the
CTT's own "type not defined within the test-script" notes. No other
change. |
| p03-base-view-method | No change. View Basic 2 `018.js` and View
Minimum Continuation Point 01 `012.js` still pass. |
| p13-monitored-items | Deadband `Err-006.js` still Error (C56). With
the script fix it passes. Monitor Basic `007.js` gave a
response-timestamp delay warning (>200 ms) caused by machine load; it
also appears in the 2026-09-29 base run. |

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 05:50:30 +00:00
romanett 2415503ab9 Close CTT skips in the reference server sample address space, diagnostics EnabledFlag and project settings (#4485)
Closes #4479

The CTT skipped a number of reference-server test cases because the
sample address space, the diagnostics EnabledFlag or the CTT project
settings did not provide what the scripts need. This PR fixes the sample
data and the server behaviour behind those skips, updates
`samples/UAReferenceServer.ctt.xml`, and records the CTT script defects
that the newly running cases expose.

## Changes

### Sample address space (`ReferenceServer.NodeSet2.xml`,
`ReferenceNodeManager`)

| # | Skip | Fix |
| --- | --- | --- |
| 1 | Base Info Engineering Units `004.js`: ArrayItemType
`EngineeringUnits` have an empty NamespaceUri | UNECE `mV` (12890)
EUInformation, and the axis definitions use `s` (5457219) instead of
UnitId 0. |
| 2 | Data Access PercentDeadband `006/016/017`:
`DataAccess_AnalogType_Float` EURange 0..0 | EURange 0..100 like the
other analog items. |
| 3 | Attribute Read `033.js` (19 nodes): second dimension of 3 | All
`Scalar_Static_Arrays2D_*` are 5x5 (generated values; the Variant matrix
holds scalar Int32 elements). The code-seeded Integer/Number/UInteger
matrices are 5x5 too. |
| 4 | View Minimum Continuation Point 01 `012.js`, View Basic 2
`018.js`: Method/View nodes need two references of their own NodeClass |
`Methods_Void` HasCause/HasEffect to two methods, `Views_Operations`
HasCause/HasEffect to `Views_Engineering`. |
| 5 | Base Info Server Capabilities 2 `002.js`: no node without
MinimumSamplingInterval | `DataAccess_DataItem_String` reports
`Bad_AttributeIdInvalid` for the optional attribute (Part 3 §5.6.2). A
DA item is used because Address Space WriteMask writes every attribute
of the static scalars back. |
| 6 | Historical Access Read Raw `Err-025.js`: no non-historizing Static
Scalar | New `Scalar_Static_NonHistorizing_Boolean` (HistoryRead access,
Historizing = false). See the historian change below. |
| 10 | Address Space Atomicity `001.js`: no NonatomicRead node found |
New `AccessRights_AccessAll_NonatomicReadWrite`. The script examines
only the first 10000 variables sorted by NodeId string; the 5000 mass
variables sort before `Scalar_Static_NonatomicReadWrite`. |

### Server library

- **Diagnostics EnabledFlag (item 7, Base Info Diagnostics
`018-1/2/3`).** `Server.ServerDiagnostics.EnabledFlag` is writable for
SecurityAdmin or ConfigureAdmin over SignAndEncrypt (UserAccessLevel
hook, asynchronous write handler); other users get
`Bad_UserAccessDenied`. Transitions are serialized, including the node
removal. Disabling returns `Bad_NotReadable` for
ServerDiagnosticsSummary, its children and the diagnostics arrays, and
removes the session and subscription diagnostics nodes (Part 5 §6.3.3).
The server keeps the registrations: enabling restores the nodes of the
live sessions and subscriptions with the same NodeIds (sessions created
while disabled included) and resets the arrays to Good. Counters stay
cumulative (required by `018-1.js`). Subscriptions created while
diagnostics are disabled still get no diagnostics node.
- `DiagnosticsNodeManager.IsDiagnosticsStructureNode` had an inverted
NodeId check, so monitored diagnostics nodes never started the scan
timer; `OnMonitoringModeChangedAsync` counted every node and replaced a
running timer. Both fixed.
- **Non-historized nodes (item 6).** `HistorianDispatcher` raw/modified,
processed and at-time reads ask the resolved provider
`IsHistorizingAsync` and return `Bad_HistoryOperationUnsupported` for a
node it does not historize, instead of the empty result the in-memory
historian gave for any node.
- **Browse order (item 8).** `ReferenceDictionary.Find` returned
references of a type from hash-based target maps, so a Browse filtered
by ReferenceType returned references in a different order than an
unfiltered Browse. It now returns them in insertion order (no extra
allocation; a single match keeps the fast path). View Basic 2 `015.js`
compares both lists by index. The characterization test in
`NodeStateReferenceStorageTests` is updated accordingly.

### CTT project settings (`samples/UAReferenceServer.ctt.xml`)

| Setting | Old | New |
| --- | --- | --- |
| `/Server Test/NodeIds/Static/All Profiles/Scalar/Bool` |
`ns=2;s=Scalar_Static_Boolean` |
`ns=2;s=Scalar_Static_NonHistorizing_Boolean` |
| `/Server Test/NodeIds/References/Has References of a ReferenceType and
SubType` | `ns=2;s=References_HasReferenceTypeAndSubType` | `i=2253` |
| `/Server Test/NodeIds/NodeClasses/Object` | `ns=2;s=Scalar` | `i=2253`
|

`References_HasReferenceTypeAndSubType` loses its
HasComponent/HasOrderedComponent references in the source generator;
that is tracked in #4484 and not changed here. The Server object has
HasComponent and HasAddIn references.

### Decisions

- **Item 11, Attribute Write StatusCode & Timestamp `003/006/008`
(writing ServerTimestamp): unchanged.** The stack rejects writes that
contain a ServerTimestamp (`NodeState`/`BaseVariableState`), which Part
4 §5.11.4.2 allows (`Bad_WriteNotSupported`); the CTT reports it as "Not
Supported", not as an error. Side finding, not changed: the
StatusWrite/TimestampWrite AccessLevel bits are not enforced.
- **Item 6:** Part 4 §5.11.3.4 (Table 52) specifies
`Bad_HistoryOperationUnsupported`; `Err-025.js` accepts only
`Bad_NotSupported`, so the case now runs and reports that as an error.
Recorded as a CTT defect in `plans/ctt-issues.md`.
- **Item 12:** removed the stale Historical Access `Err-012.js` entry
(fixed by #4026).

`plans/ctt-issues.md` adds C32 (`Err-025.js` status code), C33
(Atomicity `001.js`: 10000 cap, operator precedence, substring matching
of `UaNodesToIgnore`) and C34 (View Basic 2 `015.js` index comparison),
and replaces the Err-025/Err-012 configuration notes with the new
settings and the EnabledFlag access requirement. Monitor Basic `039.js`
is already C17. The run procedure in `plans/ctt-testing.md` is
unchanged.

## Verification

CTT 1.05.06, scripts 1.05.513, `ConsoleReferenceServer --ctt -a`, fresh
server per conformance unit/group. "master" = 5362ec5e5 with the
unchanged project settings.

**Targeted CUs (skips before → after):** Attribute Read `033` Pass; Base
Info Diagnostics `018-2`, `018-3` Pass, `018-1` Warning (*"Session
diagnostics not available"* for the session the script creates while
diagnostics are disabled); Base Info Engineering Units `001`
Inconclusive→Pass, `004` Pass; Base Info Server Capabilities 2 `002`
Pass; Data Access PercentDeadband `016`, `017` Warning→Pass; View Basic
2 `005`, `015`, `016`, `018`, `020` Pass; View Minimum Continuation
Point 01 `010`, `011` Pass, `012` Warning→Pass; Address Space Atomicity
`001` Pass; Monitor Value Change V2 `042` Error→Pass; Historical Access
Read Raw `Err-025` runs (CTT status-code defect above); `013` fails on a
varying number of results per run (1–12, also 11 on master), the
documented continuation-point defect #16. Unchanged: Monitor Basic `039`
(CTT script error), Monitor Value Change V2 `020` skip
(`Arrays/ByteString` elements shorter than 4 bytes, not part of #4479),
Historical Access Delete Value all pass.

**Saved selection (1,882 cases) per group, errors:** Address Space Model
0 → 0, Aggregates 4558 → 4558 and Base Information 19 → 19 (identical
messages) measured master (5362ec5e5) → this PR; after merging master
(#4478) and the review fixes, Aggregates 4210 and Base Information 19;
Attribute Services, Base Services, Data Access, Method Services and View
Services 0 errors with this PR (0 in the recorded baseline).

**Tests** (net10.0): Opc.Ua.Types.Tests 10395 passed,
Opc.Ua.Server.Tests 5561 passed, Opc.Ua.InformationModel.Tests 1082
passed, Opc.Ua.History.Tests 519 passed, Opc.Ua.Client.Tests 2266
passed; no failures. New regression tests: `ReferenceServerTests`
(units/ranges, 5x5 matrices, missing MinimumSamplingInterval,
non-historizing HistoryRead, NodeClass references, Server object
reference subtypes, both nonatomic nodes),
`DiagnosticsNodeManagerTests.SetDiagnosticsEnabledAsync_Toggle_HidesAndRestoresDiagnosticsAsync`,
`BaseInfoEnabledFlagToggleTests` (admin-only write, Bad_NotReadable
while disabled, restore after enable),
`ReferenceTableTests.FindReturnsReferencesInInsertionOrder`.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5 <noreply@anthropic.com>
Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com>
Co-authored-by: romanett <7413710+romanett@users.noreply.github.com>
2026-09-15 16:59:04 +00:00
romanett 162fc5ebb3 Fix AddNodes scaling and OpenSecureChannel revocation errors found by CTT Monitored Item, Node Management and security runs (#4486)
# Description

Findings from running the CTT conformance groups **Monitored Item
Services**, **Node Management Services**, **Security General** and
**Security User Token** against `ConsoleReferenceServer --ctt` (CTT
1.05.06, scripts 1.05.513). The security groups ran **without `-a`**,
against an isolated server PKI built from the CTT's `copyToServer`
folders, so the negative certificate tests are meaningful.

## Server fixes

### AddNodes below one parent was quadratic (Node Management Delete Node
`Err-002.js`)

The CTT adds 15,000 variables below `ns=2;s=CTT` in batches of 5,000 and
warned that AddNodes responses took 400–800 ms. For every added node the
server searched all children of the parent twice: once in the BrowseName
duplicate check in `AsyncCustomNodeManager.AddNodeCoreAsync`, which also
copied the children list, and once in the NodeVersion lookup of
`FilterChangesByNodeVersion`.

- `NodeState.FindChild` now searches children lists with ≥ 64 entries
through a BrowseName index kept in a `ConditionalWeakTable`, so nodes
with few children get no extra field.
- It keeps first-match semantics and is maintained by
`AddChild`/`RemoveChild`.
- It is dropped on replacement and invalidated when a child is renamed
or moves to another parent.
- Lists whose children point at another parent (clones) are still
searched linearly.
- The duplicate check uses `FindChild` instead of copying the list.

| 5,000-node AddNodes batch (in-process, Debug) | 1st | 2nd | 3rd |
| --- | --- | --- | --- |
| before | 769 ms | 2,083 ms | 4,011 ms |
| after | 141 ms | 166 ms | 172 ms |

In the CTT, AddNodes of 5,000 items now answers in 51–72 ms and the
warning is gone.

### OpenSecureChannel leaked revocation errors (Security Certificate
Validation `002.js`)

Part 4 §6.1.3, Table 106:
- For the revocation check (`Bad_CertificateRevoked`,
`Bad_CertificateIssuerRevoked`), `Bad_SecurityChecksFailed` **shall** be
reported to the client.
- For a missing revocation list (`Bad_CertificateRevocationUnknown`,
`Bad_CertificateIssuerRevocationUnknown`), it **should** be.

`TcpServerChannel` masked only `Bad_CertificateRevoked`, and
`StandardServer.OnApplicationCertificateError` (CreateSession) had its
own list that missed `Bad_CertificatePolicyCheckFailed`. Both now use
one helper, `CertificateErrorReporting` in Opc.Ua.Core, which also
inspects the nested errors of the certificate validator (both paths now
throw the validation result with `ThrowIfInvalid`). Only validity
period, host name, URI and usage errors keep their own code, and audit
events still carry the specific result. The CTT warning is gone.

### Sample data

- **Monitor Value Change V2 `020.js`** skipped because
`Scalar_Static_Arrays_ByteString` had a 1-byte and a 3-byte element. The
script checks every element, and the simulation only padded elements
0–2. The seed value now has no element shorter than four bytes, and the
simulation pads every element.
- **Monitor Value Change V2 `042.js`** got 18 of 19 notifications. The
missing item is the Float matrix: its element [1,1] was
`-1.03179664E+33`, where adding 1 is below Float precision, so the value
really did not change. The server did not drop a notification. The
element is now `-1031.79664`.

## CTT results after the fixes

| Group | Result |
| --- | --- |
| Monitored Item Services (208) | Monitor Value Change V2 44/44.
Remaining: Monitor Basic `039.js` (C17, missing include), `038.js`
warning (C32), and 1–2 sporadic timestamp-tolerance warnings that move
between test cases from run to run. |
| Node Management Services (15) | Only Add Node `Err-008.js` (Mantis
11266). |
| Security General (314) | Certificate Validation: 23 pass, 24 not
implemented, 3 not-applicable skips. None CreateSession/ActivateSession:
all pass. The other 50 CUs are *Not Implemented* in scripts 1.05.513. |
| Security User Token (66) | Anonymous `002.js` (C35) and User Name
Password 2 `015.js` (C36) fail because of CTT defects. X509: 18/18
automated cases pass. |

## CTT defects documented (`plans/ctt-issues.md`)

- **C32** `038.js` compares a RevisedSamplingInterval of 0 with a
project setting instead of the node's MinimumSamplingInterval or the
server's MinSupportedSampleRate.
- **C33** `020.js` requires every ByteString element to be ≥ 4 bytes,
but its message says elements 0–2.
- **C34** `RequestedNewNodeId()` always sends `ns=1`, regardless of
`RequestedNodeId_Namespace`, so client NodeIds can't be enabled.
- **C35** Security User Anonymous picks the `opc.wss` endpoint, which
the CTT cannot open (`BadNotSupported`).
- **C36** `UaEndpointDescription.FindTokenType` rewrites the cached
endpoints' token policies, so `015.js` reports PolicyIds as reused. The
server's GetEndpoints output was verified compliant (PolicyIds unique
per configuration, Mantis 11258).
- Evidence added to **C9** (042.js) and **issue 17** (015.js).

`plans/ctt-testing.md` gains how to run the Monitored Item/Node
Management groups and a recommended setup for the security groups:
isolated PKI from `copyToServer`, no `-a`, PKI restore per part, and
waiting for `Server started`. Other findings recorded there:
- the Create/DeleteMonitoredItems timing warnings are jitter;
- `LoginNameAccessDenied` is not a real user;
- `samples\UAReferenceServer.ctt.xml` needs no change (enabling
`RequestedNodeId` breaks six Add Node cases because of C34).

**Note:** `plans/ctt-testing.md` and the refreshed `plans/ctt-issues.md`
are introduced by #4482. The plans files here are based on #4482's
versions, and new entries start at C32 because #4481 uses C19–C31.
Please merge after #4482 (or rebase the plans files onto it).

## Tests

- `NodeStateChildNameIndexTests` (Opc.Ua.Types.Tests): index semantics
(duplicates, remove, rename, replace, re-parent, clone, shrink/grow,
2,000 random operations against a linear search). Also a scan guard:
5,000 misses against 50,000 children take 97 ms with the index and 7,083
ms with it disabled.
-
`AsyncCustomNodeManagerNodeManagementTests.AddNodeAsync_DuplicateBrowseNameUnderParentWithManyChildren…`
- `TcpServerChannelCertificateErrorTests` (Opc.Ua.Core.Tests): masked vs
reported certificate errors.
- Opc.Ua.Server.Tests 5,553 passed, Opc.Ua.Core.Security.Tests 556
passed, Opc.Ua.Core.Tests (Security + Stack) 3,561 passed,
InformationModel NodeManagement 26 passed (net10.0).
- Opc.Ua.Types.Tests 10,404 passed and 1 failed:
`WotSpecFixtureManifestTests.EveryEmbeddedExampleMatchesItsRecordedHash`.
That test hashes WoT assets which are `eol=lf` in the index but CRLF in
this worktree's checkout; no WoT file is touched by this PR.

## Checklist

- [x] I have signed the CLA and read the CONTRIBUTING doc.
- [x] I have added tests that prove my fix is effective or that my
feature works.
- [x] I have added all necessary documentation.
- [ ] I ran all tests locally using UA.slnx against .NET Framework and
.NET 10 (net10.0 suites listed above only).

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5 <noreply@anthropic.com>
Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com>
Co-authored-by: romanett <7413710+romanett@users.noreply.github.com>
2026-09-15 10:08:30 +00:00
romanett d547747e22 Generate ReferenceNodeManager address space from a NodeSet2 model (#4220)
# Description

The CTT/compliance `ReferenceNodeManager` built its ~6,000 node address
space entirely in imperative C#. This PR migrates it to a
source-generated `[NodeManager]` partial driven by an exported NodeSet2
model (`ReferenceServer.NodeSet2.xml`), mirroring the
`MinimalBoilerServer` sample and completing the goal of issue #4204.

The address space is now materialized from the model by the source
generator. The large orchestration body was kept but converted from
create-based to **find-instead-of-create**: each `Create*` primitive now
looks up the model-materialized node via `FindPredefinedNode<T>` and
re-applies runtime values, DataAccess metadata, and write handlers,
rather than constructing nodes from scratch. This keeps the
deterministic value seeding and behavior wiring intact while the
structure comes from the model.

## Notable details for reviewers

- **Idempotent reference wiring.** The mesh references in the
`References` folder are already present in the model, so the historic
manual `AddReference` calls would throw on duplicates. Added a small
`AddReferenceIfMissing` helper so those calls are safe.
- **Non-string NodeIds.** The `NodeIds` folder assigns numeric / GUID /
opaque NodeIds. The model exports those nodes with their final ids, so
find-by-string-path no longer works; added `CreateVariableById(NodeId)`
to locate them by their real id.
- **Generator bug fix (worth a careful look).**
`ModelDesignExtensions.GetValueRankAsCode` reconstructed `ValueRank` as
`dimensions.Length + 1`, so a node with `ArrayDimensions="3,3"` was
emitted as `ValueRank = 3`. This affected **any** NodeSet2 with a fixed
multi-dimensional array (rank-3 matrices, `BadTypeMismatch` on
whole-matrix writes, wrong decoded dimensions). Corrected to
`dimensions.Length` and updated the unit tests that had codified the
off-by-one.

## Validation

- `ReferenceServerTest`: 44/44 on net10.0 and net48
- `Opc.Ua.SourceGeneration.Core.Tests`: pass on
net8.0/net9.0/net10.0/net48
- Integration on net10.0: ComplexTypes, Client, History, Sessions,
Subscriptions all pass
- Clean build, no new analyzer warnings

## Related Issues

- Fixes #4204

## Checklist

_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [ ] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [x] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

---------

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-08-15 05:22:31 -07:00