4 Commits

Author SHA1 Message Date
Marc Schier 0374e19121 Add MachineTool, WMTP, GMS and CranesHoists companions (#4765)
# Description

_Describe the changes here to communicate to the maintainers why they
should accept this pull request. By default - this will become the
Commit message after merging and thus define history._

Add provider-backed MachineTool, bundled WMTP, GMS and CranesHoists
companions using the existing Machinery/MachineVision fluent, DI and
typed-client approach. **The PR is open/non-draft by user choice.
Current head `ecc4a7d6ca3e8004cf28ab54da605da302d026bf` is mergeable and
has 108 successful checks, six intentionally skipped checks, zero
failures and zero pending checks. All five primary workflows completed
successfully at that exact head.**

| Family | Released specification/model | Packaging |
| --- | --- | --- |
| MachineTool | OPC 40501-1, 1.02.0 | Model, Server, Client and MCP;
normal root versions |
| WMTP | OPC 40505, 1.0.0 | Bundled in MachineTool; distinct CLR/wire
namespace and independent WMTP-only hosting |
| GMS | OPC 40210 reference 1.0.1, normative model 1.0.0 | Model,
Server, Client and MCP; normal root versions |
| CranesHoists | OPC 40020-1, 1.00 | Model, Server, Client and MCP; all
four plus Debug variants forced preview |

There are **12 new packable projects**. No separate WMTP
package/profile/guide, root version bump, tag, release or package
publication is included. Mandatory instance structure is the default;
selected optional features require explicit providers. The
implementation reuses Machinery results/jobs/files/ProcessValues and
Robotics topology, including retained MachineTool Production, defined
GMS jobs/parts, modern ISA95/Machinery jobs, shared-owner hosting and
isolated instances alongside MachineVision.

Runtime and integration fixes preserve raw quality/timestamps, coherent
acquisition, namespace ownership, accepted-configuration state,
borrowed-resource lifetime, session/node/file cleanup, terminal-value
publication, event propagation and endpoint-aware capability
publication. Firmware/licence transfer means provider acceptance, not
installation/activation. Cancellation does not silently abort another
caller's operation. The later upstream MCP expansion is integrated
without losing either family set or its default-off privileged/live
execution policy.

### Conformance and scope

Canonical model inputs are pinned to UA-Nodeset revision
`96a08945425d0295edb3607d2a38f6841ef44046`.

**GMS upstream exception:** [Annex
A.1](https://reference.opcfoundation.org/specs/OPC-40210/annex-a) makes
the released NodeSet normative, but §12.3.2.7 requires undefined
`GMS_ProductionStatisticsType`. Inherited statistics and defined
jobs/parts are implemented without inventing a standard type/NodeId; the
complete GMS Production facet is withheld.

The requirement ledger records **102 positively evidenced CU rows, 96
directly negative-tested rows and six explicit negative-evidence
limitations**. All 648 test-class/name/TRX links were independently
resolved to passing cases. The six limitations concern Stacklight,
retained legacy PowerOnDuration, Machinery PowerOnDuration, WorkingUnit,
Obligation and MaintenanceMode. They are not claims that every
invalid-input or hardware-control behavior was tested. The undefined GMS
requirement is outside the 102 defined CUs. No external certification
claim is made.

Retained baseline complete-assembly line coverage, with generated code
retained and no source exclusions:

| Family | Model | Server | Client |
| --- | ---: | ---: | ---: |
| MachineTool/WMTP | 83.80% | 91.98% | 84.74% |
| GMS | 95.51% | 90.63% | 88.38% |
| CranesHoists | 92.76% | 94.45% | 92.24% |

These nine measurements predate the later focused review fixes and
merges; they are not relabelled as new `ecc4a7d6c` percentages. The
current head's separate CI code-coverage check succeeded. No new
exclusions or threshold relaxations were introduced.

## Related Issues

- Fixes
[#4764](https://github.com/OPCFoundation/UA-.NETStandard/issues/4764),
the implementation/design and acceptance tracker.

## Checklist

_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [ ] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [x] I have addressed **all** PR feedback received.
2026-10-15 15:15:46 +02:00
Marc Schier 15d0ce7bd5 Implement OPC UA Part 10 Programs (#4789)
# Description

Implement OPC UA Part 10 Programs across `Opc.Ua.Core`/`Core.Types`,
`Opc.Ua.Server`, and `Opc.Ua.Client`, reusing the existing
state-machine, source-generation, node-management, auditing, and
streaming-subscription infrastructure.

- Add asynchronous provider-backed execution, standard controls,
internal/autonomous transitions, generation checks, and nested-state
activation/resumption.
- Add checked creation/adoption, vendor Create adapters, deletion,
recycling and instance limits, auto-delete, DI, and direct-construction
paths.
- Maintain ProgramDiagnostic2 and retained final results; publish
captured intermediate results and concrete transition/audit events with
access controls.
- Add generated SDK models/proxies, typed client discovery and reads,
event streams, and subscribe-before-call readiness handling.
- Add unit, connected client/server, generated Annex A-style model, and
NativeAOT coverage. Document usage and migration in `docs/Programs.md`
and related guides.

### Compatibility and design decisions

The linked Part 10 document is v1.05.00; namespace-zero definitions
remain aligned with 1.05.07. Documentation distinguishes normative
requirements from conflicting specification text and SDK conventions.

- Correct state numbers to Halted=11, Ready=12, Running=13,
Suspended=14. Generated subtypes retain inherited namespace-zero
state/transition identifiers.
- Managed Reset is Halted-to-Ready only. Preserve the existing low-level
Reset-from-Suspended behavior for compatibility.
- Preserve UInt32 limit types; use `UInt32.MaxValue` as a documented SDK
unlimited convention. RecycleCount overflow reports BadOutOfRange
without stopping unlimited execution.
- In-memory default with injectable providers. Durable recovery,
distributed execution/failover, and a production Annex A download engine
are excluded.

## Checklist

_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [ ] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

Tests and focused coverage evidence are above; the combined
tests/coverage checkbox remains open because a whole-repository coverage
increase has not been established. CLA status, CI/CodeQL results,
tracking-issue approval, and PR feedback are not asserted.
2026-10-15 09:19:25 +02:00
romanett 9b034f8291 Enable nullable reference types centrally; migrate all unset and annotations-only projects (#4700)
# Description

Nullable reference types are now enabled once, in `common.props`, and
every project in the repository builds warning-clean with them.

**Configuration**
- `<Nullable>enable</Nullable>` lives in `common.props`. All per-project
`<Nullable>` settings are removed: 178 project files (enable,
annotations, and the `disable` in the three Aot test projects).
- 419 per-file `#nullable enable`/`restore` directives and the 4
`#nullable disable` directives are removed.
- Kept on purpose:
- The 5 `<auto-generated>` schema files (`UANodeSet.cs`, `UA Type
Dictionary.cs`, `OPCBinarySchema.cs`, `SecuredApplication.cs`,
`PInvokeHelper.cs`) keep `#nullable enable`. The compiler ignores the
project setting in generated code, so the directive is required there.
- `tests/Opc.Ua.Interop.LegacyPeer` keeps `disable`. It builds against
the 1.5.378 packages and does not import the repository props.
- `docs/DeveloperGuide.md` and `.github/copilot-instructions.md` now
describe the central setting.

**Migration** (the 43 unset and 13 annotations-only projects, roughly
10k diagnostics)
- **Production code: annotated at the declarations.** Covers
`tools/Opc.Ua.SourceGeneration.Core`, `src/Opc.Ua.Lds.Server` and the
LDS sample.
- Members, parameters and returns are nullable where null actually
flows.
- Null-check helpers carry `[NotNullWhen]` (`IsNull`, `IsValidXmlName`,
`IsMethodTypeDesign`).
- `CoreUtils.Format`, `Utils.Format`, `ITemplateWriter.WriteLine` take
`params object?[]`. `Template.AddReplacement` takes `string?` (rendering
already skips null replacements).
- `IRegisteredServerStore.RegisterAsync` returns
`Task<RegistrationEntry?>`: it returns null when a registration is
removed.
- Dereferences backed by an invariant (for example, the validated model)
use `!`, so runtime behaviour is unchanged.
- **Behavioural changes in production code** (small, deliberate):
- `NodeSetToModelDesign` throws `InvalidOperationException` when the
file is not a NodeSet. Before, it threw a NullReferenceException on the
next line.
- `ModelDesignValidator` starts its lookup tables empty instead of null.
A redundant `if (m_nodes == null) return;` guard is gone.
- **Test code: minimal annotations.**
  - `?` on values that can be null, `!` where the test asserts non-null.
  - `= null!` for fixture members assigned in SetUp.
- `TryGetStructure<T>(out T? x)` where the inferred `T?` broke the
`IEncodeable` constraint.
- A few redundant `== null` checks on structs (`NodeId`, `ArrayOf<T>`)
folded into the adjacent `IsNull`/`Count` checks.

**Notes for reviewers**
- The diff is large (~1,500 files) but almost entirely mechanical: `?`,
`!` and directive removal. The non-annotation changes are listed above.
- Known follow-up, not done here:
`IModelDesign.Namespaces/TargetNamespace/NamespaceUris` stay
non-nullable even though the validator returns null before it loads a
dictionary. Making them nullable would ripple through every generator
call site.

## Related Issues

- Fixes #4439

## Checklist

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [ ] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

The "no new warnings" box covers net10.0 and net48: full non-incremental
builds of `UA.slnx`, `tools/SourceGeneration.slnx`,
`tools/MigrationAnalyzer.slnx` and the Aot test projects finished with 0
warnings and 0 errors under the repository's warnings-as-errors
settings. net9.0 and net8.0 also had no nullable diagnostics, but they
were not rebuilt after the final fixes. Tests have not been run locally
yet.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 08:48:13 +02:00
Marc Schier 7cec2d614d Move repository files to the consolidated layout 2026-07-16 06:25:54 +02:00