4 Commits

Author SHA1 Message Date
Marc Schier 0612a43fe4 Pluggable cryptography and hardware-held private keys (#4192)
Makes the stack's cryptographic operations replaceable - by another library, an offboard service, or hardware (TPM 2.0 / HSM / PKCS#11 token / cloud KMS) - with no performance cost in the default configuration, and extends this to certificates so a private key need never exist in process memory.

Also fixes three pre-existing defects found while validating: STACKGEN001 erroring for every compilation the stack generator was merely loaded into, certificates failing to load from paths past MAX_PATH on Windows, and the MonitoredNode2 tests starving the thread pool.

Fixes #4190
2026-08-09 12:40:26 +02:00
Marc Schier 76d33cb139 Remove SourceGenerator.Foundations, ship analyzers under Roslyn-versioned folders for VS2022 and VS2026, and validate the packages (#4120)
# Description

The two OPC UA source generators were built on
`SourceGenerator.Foundations` (SGF), whose only job was getting the
generator's dependency closure loaded inside the compiler. It does so
with a **process-wide, first-generator-wins `AppDomain.AssemblyResolve`
hook backed by a non-concurrent `Dictionary` mutated from `AssemblyLoad`
callbacks**. Concurrent compilations in a shared `VBCSCompiler` race it,
which is the root cause of the intermittent clean-build failure:

```
CSC : error CS8784: Generator 'StackSourceGeneratorHoist' failed to initialize. ...
Exception was of type 'FileNotFoundException' with message 'Could not load file or assembly
'SourceGenerator.Foundations.Contracts, Version=2.0.14.0, ...'
```

The repository already solves that problem deterministically — #4041
made the NuGet packages ship the full closure under
`analyzers/dotnet/.../cs`, and `Directory.Build.targets` registers the
same closure as `Analyzer` items for in-repo `ProjectReference`
consumers. SGF was therefore pure liability and is removed.

## What changed

**1. SourceGenerator.Foundations removed.** `ModelSourceGenerator` and
`StackSourceGenerator` are plain `[Generator(LanguageNames.CSharp)]
IIncrementalGenerator` implementations again. SGF's implicit crash
handling is replaced by an explicit `SourceGenerator.Guard` that reports
`MODELGEN003` / `STACKGEN003` and rethrows cancellation. Its logger sink
was already dead code and is dropped.
`Opc.Ua.SourceGeneration.Stack.dll` shrank from **18 MB** (embedded
closure) to **29 KB**.

**2. Analyzers now ship under Roslyn-versioned folders.**
`analyzers/dotnet/roslyn4.14/cs` and `analyzers/dotnet/roslyn5.0/cs`
instead of `analyzers/dotnet/cs`, driven by `roslyn.props` at the
repository root, with new `*.Pack` projects owning the package identity.
The versioned folder matters: a host older than the band **skips** the
analyzer instead of loading it and failing inside generator
initialization.

**3. Dependencies flow automatically.** Both delivery paths discover the
payload by globbing the generator's output directory, so adding a
package to a generator's dependency tree requires **no** `.csproj`,
`.targets`, `.nuspec` or validation-script edit. Verified by temporarily
adding a `PackageReference` and watching it appear in the payload with
no other file touched.

## Two Roslyn bands: VS2022 and VS2026

Analyzers ship twice, once per band. The .NET SDK loads the highest band
its compiler supports and **silently skips** anything above it, so a
single-band package leaves every consumer below that band with no
diagnostics and no generated code.

| Band | Built against | Loaded by |
| --- | --- | --- |
| `roslyn4.14` | `Microsoft.CodeAnalysis.CSharp 4.14.0` | Visual Studio
2022 17.14+ / .NET 9 SDK |
| `roslyn5.0` | `Microsoft.CodeAnalysis.CSharp 5.0.0` | Visual Studio
2026 18.0+ / .NET 10 SDK |

Getting this wrong is invisible, which is most of why it took three
attempts. The rule:

> An analyzer must reference the **lowest**
`System.Collections.Immutable` / `System.Reflection.Metadata` across all
hosts it claims to support, and must never ship them. .NET binds a
reference *upward* but never downward.

Every failure mode is a compiler **warning**:

| Diagnostic | Cause |
| --- | --- |
| `CS9057` | Built against a newer Roslyn than the host, so it is
skipped entirely |
| `CS8784` | Loaded, then `MissingMethodException` - a shipped S.C.I
bound a second `ImmutableArray<T>` |
| `CS8032` | Analyzer instance could not be created |

This PR first shipped a `roslyn4.8` band that **never loaded** -
confirmed against a real Roslyn 4.8 compiler:

```
warning CS8784: Generator 'ModelSourceGenerator' failed to initialize ...
MissingMethodException: Method not found:
'IncrementalValueProvider`1<ImmutableArray`1<!!0>>
 IncrementalValueProviderExtensions.Collect(IncrementalValuesProvider`1<!!0>)'
```

That band was removed, and **this is not a regression**: master had the
same defect, pinned to Roslyn 4.14 while referencing
`System.Collections.Immutable 10.0.0.0`, so no 4.x host ever worked
there either.

The band that landed instead is `4.14`, and it is nearly free:
`Microsoft.CodeAnalysis 4.14` depends on the **same S.C.I 9.0.0 as
5.0.0** and its `csc` runs on `net9.0`. Both bands therefore share
`$(RoslynRuntimeVersion)`, so `Opc.Ua.Types` and
`Opc.Ua.SourceGeneration.Core` are compiled **once** and serve both;
only the five Roslyn-referencing assemblies get a second build, each
from a 12-line project that glob-links the primary sources and overrides
`RoslynApiVersion`. Going lower still - 4.8 wants S.C.I 7.x - would mean
rebuilding that whole closure, `Opc.Ua.Types` included, and remains out
of scope. (`System.Collections.Immutable 7.0.0` also does not resolve in
this repository: `NU1603`, 8.0.0 substituted.)

**Nothing else in the repository exercises the down-level payload**, and
since every failure is a warning, a broken band would ship silently -
exactly as the 4.8 one did. So `validate-source-generator-packages.ps1`
now restores a real `Microsoft.Net.Compilers.Toolset 4.14.0`, runs its
`csc.dll` over the packed `roslyn4.14` payload, and asserts **both**
that none of `CS9057`/`CS8784`/`CS8032`/`CS8034` is emitted **and** that
`/reportanalyzer` lists the generator as having executed - silence alone
would also pass if the generator were never handed to the compiler. The
migration analyzer, whose payload comes from a hand-written nuspec
rather than `SourceGeneratorPack.targets`, gets the same check plus a
band/assembly manifest assertion.

To stop the trap recurring, `Microsoft.CodeAnalysis*`,
`System.Collections.Immutable` and `System.Reflection.Metadata` are
excluded from both the package payload and the in-repo analyzer closure,
and asserted against in the validation script. `roslyn.props` and
`docs/DeveloperGuide.md` document what adding a band requires.
## The shipped package set is unchanged

Evaluating `PackageId`/`IsPackable` across every project in
`preview-pack.slnx` gives the **same 47 package ids** on `master` and on
this branch, and a full Release build plus `dotnet pack --no-build`
produces exactly those 47. Only the owning project changed:

| Package | master | this PR |
| --- | --- | --- |
| `…Opc.Ua.SourceGeneration` | `Opc.Ua.SourceGeneration.csproj` |
`Opc.Ua.SourceGeneration.Pack.csproj` |
| `…Opc.Ua.SourceGeneration.Stack` |
`Opc.Ua.SourceGeneration.Stack.csproj` |
`Opc.Ua.SourceGeneration.Stack.Pack.csproj` |

`.azurepipelines/expected-packages.txt` pins the expected set and the
validation script fails when the packed output drifts.

## Two new package checks

**`build/<PackageId>.props` naming.** NuGet only auto-imports that exact
name, and the file declares every `CompilerVisibleProperty` /
`CompilerVisibleItemMetadata` the model generator relies on. It was
previously packed as
`build/OPCFoundation.Opc.Ua.SourceGeneration.props`, which does **not**
match the package id — so **no NuGet consumer ever imported it**, and
every `ModelSourceGenerator*` property and `AdditionalFiles` metadata
was silently invisible. In-repo projects were unaffected because they
import it by relative path.

**An end-to-end consumer that actually drives the generator.** The
pre-existing clean-consumer check only proved the analyzer *loads*.
`Test-SourceGeneratingConsumer` builds a standalone project that feeds a
real NodeSet2 in as an `AdditionalFile`, pins a
`ModelSourceGeneratorPrefix` that cannot be derived from the model, and
references the emitted types from hand-written code. It deliberately
does **not** import the props by path, so the package's auto-import is
what is under test. Both checks were verified to fail against a package
rebuilt with the misnamed props.

## CI: parallelism re-enabled

`buildandtest.yml` pinned three `dotnet build` invocations to
`/p:UseSharedCompilation=false` and `-maxcpucount:1`. `dotnet build`
defaults to all logical processors, so `-maxcpucount:1` actively
disabled parallelism. Both flags were introduced silently in unrelated
PRs (`f358078b1`, `208c601b0`) and suppress exactly the conditions the
SGF race needed — now structurally gone. Compilation is ~72 % of what
that workflow executes (233 of 323 job-minutes in run `29916768976`), so
the queue-independent `Build` step durations are the baseline:

| Measurement | Baseline |
| --- | --- |
| `Build` step, 26 `test-*` jobs | mean 5.53 min, sum 143.9 min |
| `build-linux-all-tfm` | 56.3 min |
| `build-windows-all-tfm` | 32.5 min |

`codeql-analysis.yml` keeps the flag — the CodeQL tracer requires it.

## Incidental fixes

- `Microsoft.CodeAnalysis.CSharp` declares an exact `[version]` range on
`Microsoft.CodeAnalysis.Common`, so with
`CentralPackageTransitivePinningEnabled` the central pins must move in
lockstep or restore fails with `NU1109`. They now derive from
`$(RoslynApiVersionVS2026)`.
- `MigrationGeneratorTests` created its generator driver without parse
options — silently fine under Roslyn 4.14, `Inconsistent language
versions` under 5.0.
- The migration analyzer props injected `<Analyzer>` items by hand from
`analyzers/dotnet/cs`; NuGet registers analyzers itself and selects the
matching folder, so the injection was obsolete and would now force the
wrong assembly to load.
- Exception diagnostics reported `ex.StackTrace` (null for an exception
that never left its throw site, and carrying neither type nor inner
chain) — now `ex.ToString()` at all three call sites.
- The pack guard tested the flattened assembly list, so it only fired
when *no* variant produced output; it now checks each declared variant
contributed assemblies.
- `GeneratePackageOnBuild` is disabled for the generators; packing
happens in CI or on an explicit `dotnet pack`.

## Note for reviewers

**Building this repository requires a Roslyn 5.x host** (the .NET 10 SDK
or Visual Studio 2026). That is already the documented prerequisite and
every CI leg installs `10.0.x` last, but it is now a hard requirement.

## Related Issues

_No tracking issue: this is a follow-up to the CS8784 clean-build
failure reported against #4041, which fixed the packaged delivery path
but left the in-repo project-reference path relying on the SGF
resolver._

- Follow-up to #4041

## Checklist

_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._

- [x] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [x] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

### Verification detail

| Check | Result |
| --- | --- |
| `dotnet build UA.slnx` (clean, and after merging master) | 0 errors;
18 warnings, all pre-existing `CA1873` in `Opc.Ua.Client` |
| `Opc.Ua.SourceGeneration.Tests` | 81/81 on net10.0 and net48 |
| `Opc.Ua.SourceGeneration.Stack.Tests` | 92/92 on net10.0, 89/89 on
net48 |
| `Opc.Ua.SourceGeneration.Core.Tests` | 3722 passed, 8 skipped |
| `Opc.Ua.MigrationAnalyzer.Tests` | 121/121 on net10.0 and net48 |
| Package id set, master vs branch | identical, 47 packages |
| Release build + `dotnet pack --no-build` | 47 packages, matching the
manifest; both `roslyn4.14` and `roslyn5.0` present; no host-provided
assemblies shipped |
| `validate-source-generator-packages.ps1` | passes, including manifest,
props-naming, end-to-end generator consumer and down-level host checks |
| Down-level band under real csc 4.14.0 | all three analyzer packages
load **and run** |
| Negative tests | misnamed props → both checks fail as designed; hidden
variant output → pack guard fires; 5.0 build placed in `roslyn4.14` →
real `CS9057`; non-running generator name → execution assertion fires;
expecting a `roslyn4.8` band → manifest check fires |

---------

Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Copilot-Session: 9ed53262-5cfa-429a-820e-bf6146a00d8b
2026-07-31 15:46:17 +00:00
Marc Schier 5b9bcedc62 Add OPC UA ISA-95 Common Model and Job Control support (#4089)
# Description

Adds first-class support for the OPC UA ISA-95 companion specifications:

- OPC-10030 Common Model.
- OPC-10031-4 Job Control V1.
- OPC-10031-4 Job Control V2.

The change introduces `Opc.Ua.ISA95`, `Opc.Ua.ISA95.Client`, and
`Opc.Ua.ISA95.Server`, together with a NativeAOT-compatible minimal
server sample and comprehensive tests.

## Highlights

- Compiles the three canonical NodeSets and identifier mapping CSV files
through the source generator.
- Adds NodeSet identifier mapping validation, typed method
arguments/results, companion event records, and generated method
argument nodes.
- Provides typed Common Model builders with normative relationships and
an injectable `GeoSpatialLocationType` provider.
- Implements lossless V1/V2 Job Control providers over a shared
version-neutral store, including state paths, status events, comments,
response queries, catalog changes, and cohesive DI registration.
- Adds subtype-aware typed clients, standalone encodeable registration,
`IIsa95ClientFactory`, and V2 status-event streaming.
- Adds the `MinimalIsa95Server` sample, package documentation, and an
ISA-95 guide with conformance and HA guidance.
- Tracks typed RSL/GPOS integration as follow-up issue #4095.

## Validation

- `Opc.Ua.ISA95.Tests`: 137/137 passed on `net10.0` and `net48`.
- Source-generator suites: 81/81 model, 90/90 stack, 3718 passed / 8
skipped core.
- `EventRecordFieldReaders` feedback tests: 6/6 on `net10.0` and
`net48`.
- `EventRecordFieldReaders` changed-method patch coverage: 100% line
coverage (36/36) and 100% branch coverage (22/22).
- `Opc.Ua.ISA95`, `.Client`, and `.Server` build across all configured
target frameworks without new diagnostics.
- Cobertura line coverage: 88.08% model, 90.04% client, 91.19% server.
- NativeAOT sample publishes and passes a live typed V2
Store/status-event validation.
- The ISA-95 NativeAOT smoke test passes in the source-generated native
test executable.
- OPC UA KB NodeSet validation reports zero errors for Common, V1, and
V2.

The broader NativeAOT executable still reports unrelated existing GDS
and complex-type test failures; the ISA-95-specific native test passes.

## Node state generator fixes

Generating method arguments inline for imported nodesets regressed every
model that already emits `InputArguments` / `OutputArguments` child node
factories:

- The inline block ran before the child factories.
`MethodState.CreateOrReplaceInputArguments` keeps the property that was
assigned first, so the child carrying the well-known NodeId was dropped
and a NodeId-less placeholder remained in the address space. This broke
browsing (reference descriptions without a target) and made method
arguments unreachable at their well-known NodeIds.
- The `MethodDeclarationId` fallback keyed on an autogenerated display
name redirected every declared method of the standard address space to
its own NodeId, which made method calls fail.

The inline block is now emitted after the child factories and reduced to
a value assignment when a child factory exists. The value is only
re-emitted when an argument references a namespace other than OPC UA,
because the value of an imported property is the verbatim XML of the
source nodeset whose namespace indices do not survive the import. The
`MethodDeclarationId` fallback is restricted to declarations without a
resolvable NodeId. The generated OPC UA address space is byte-identical
to `master` again.

## Related Issues

- Fixes #4088
- Follow-up: #4095
2026-07-28 12:01:57 +02:00
Marc Schier 7cec2d614d Move repository files to the consolidated layout 2026-07-16 06:25:54 +02:00