http://opcfoundation.org/UA/Machinery/
http://opcfoundation.org/UA/DI/
i=1
i=3
i=5
i=7
i=12
i=13
i=17
i=20
i=21
i=26
i=28
i=35
i=37
i=40
i=45
i=46
i=47
i=51
i=52
i=256
i=290
i=291
i=887
i=17603
i=17604
ns=2;i=6244
ns=3;i=3002
IMachineTagNameplateType
Interface containing information of the identification of a machine set by the customer
Machinery Machine Identification
https://reference.opcfoundation.org/Machinery/v104/docs/8.5
ns=2;i=15048
ns=1;i=6028
ns=1;i=1012
Location
To be used by end users to store the location of the machine in a scheme specific to the end user Servers shall support at least 60 Unicode characters for the clients writing this value, this means clients can expect to be able to write strings with a length of 60 Unicode characters into that field.
i=80
i=68
ns=1;i=1011
IMachineryItemVendorNameplateType
Interface containing identification and nameplate information for a MachineryItem provided by the vendor
Machinery Machine Identification
Machinery Component Identification
https://reference.opcfoundation.org/Machinery/v104/docs/8.2
ns=2;i=15035
ns=1;i=6027
ns=1;i=6022
ns=1;i=6026
ns=1;i=6024
ns=1;i=6025
ns=1;i=1004
InitialOperationDate
The date, when the MachineryItem was switched on the first time after it has left the manufacturer plant.
i=80
i=68
ns=1;i=1003
Manufacturer
A human-readable, localized name of the manufacturer of the MachineryItem.
i=78
i=68
ns=1;i=1003
MonthOfConstruction
The month in which the manufacturing process of the MachineryItem has been completed. It shall be a number between 1 and 12, representing the month from January to December.
i=80
i=68
ns=1;i=1003
SerialNumber
A string containing a unique production number of the manufacturer of the MachineryItem. The global uniqueness of the serial number is only given in the context of the manufacturer, and potentially the model. The value shall not change during the life-cycle of the MachineryItem.
i=78
i=68
ns=1;i=1003
YearOfConstruction
The year (Gregorian calendar) in which the manufacturing process of the MachineryItem has been completed. It shall be a four-digit number and never change during the life-cycle of a MachineryItem.
i=80
i=68
ns=1;i=1003
IMachineVendorNameplateType
Interface containing identification and nameplate information for a machine provided by the machine vendor
Machinery Machine Identification
https://reference.opcfoundation.org/Machinery/v104/docs/8.4
ns=1;i=1003
ns=1;i=6023
ns=1;i=1012
ProductInstanceUri
A globally unique resource identifier provided by the manufacturer of the machine
i=78
i=68
ns=1;i=1010
MachineryItemIdentificationType
Contains information about the identification and nameplate of a MachineryItem
Machinery Machine Identification
Machinery Component Identification
https://reference.opcfoundation.org/Machinery/v104/docs/8.3
ns=2;i=1005
ns=1;i=6013
ns=1;i=6014
ns=1;i=6088
ns=1;i=6012
ns=1;i=6010
ns=1;i=1003
ns=1;i=6006
ns=2;i=15048
ns=1;i=6002
ns=1;i=6007
ns=1;i=6008
ns=1;i=6005
ns=1;i=6009
ns=1;i=6001
ns=1;i=6003
ns=1;i=6011
ns=1;i=6004
AssetId
To be used by end users to store a unique identification in the context of their overall application. Servers shall support at least 40 Unicode characters for the clients writing this value, this means clients can expect to be able to write strings with a length of 40 Unicode characters into that field.
i=80
i=68
ns=1;i=1004
ComponentName
To be used by end users to store a human-readable localized text for the MachineryItem. The minimum number of locales supported for this property shall be two. Servers shall support at least 40 Unicode characters for the clients writing the text part of each locale, this means clients can expect to be able to write texts with a length of 40 Unicode characters into that field.
i=80
i=68
ns=1;i=1004
DefaultInstanceBrowseName
The default BrowseName for instances of the type.
i=68
ns=1;i=1004
2
Identification
DeviceClass
Indicates in which domain or for what purpose the MachineryItem is used.
i=80
i=68
ns=1;i=1004
HardwareRevision
A string representation of the revision level of the hardware of a MachineryItem. Hardware is physical equipment, as opposed to programs, procedures, rules and associated documentation. Many machines will not provide such information due to the modular and configurable nature of the machine.
i=80
i=68
ns=1;i=1004
InitialOperationDate
The date, when the MachineryItem was switched on the first time after it has left the manufacturer plant.
i=80
i=68
ns=1;i=1004
Manufacturer
A human-readable, localized name of the manufacturer of the MachineryItem.
i=78
i=68
ns=1;i=1004
ManufacturerUri
A globally unique identifier of the manufacturer of the MachineryItem.
i=80
i=68
ns=1;i=1004
Model
A human-readable, localized name of the model of the MachineryItem.
i=80
i=68
ns=1;i=1004
MonthOfConstruction
The month in which the manufacturing process of the MachineryItem has been completed. It shall be a number between 1 and 12, representing the month from January to December.
i=80
i=68
ns=1;i=1004
ProductCode
A machine-readable string of the model of the MachineryItem, that might include options like the hardware configuration of the model. This information might be provided by the ERP system of the vendor. For example, it can be used as order information.
i=80
i=68
ns=1;i=1004
ProductInstanceUri
A globally unique resource identifier provided by the manufacturer of the MachineryItem.
i=80
i=68
ns=1;i=1004
SerialNumber
A string containing a unique production number of the manufacturer of the MachineryItem. The global uniqueness of the serial number is only given in the context of the manufacturer, and potentially the model. The value shall not change during the life-cycle of the MachineryItem.
i=78
i=68
ns=1;i=1004
SoftwareRevision
A string representation of the revision level of a MachineryItem. In most cases, MachineryItems consist of several software components. In that case, information about the software components might be provided as additional information in the address space, including individual revision information. In that case, this property is either not provided or provides an overall software revision level. The value might change during the life-cycle of a MachineryItem.
i=80
i=68
ns=1;i=1004
YearOfConstruction
The year (Gregorian calendar) in which the manufacturing process of the MachineryItem has been completed. It shall be a four-digit number and never change during the life-cycle of a MachineryItem.
i=80
i=68
ns=1;i=1004
MachineIdentificationType
Contains information about the identification and nameplate of a machine
Machinery Machine Identification
https://reference.opcfoundation.org/Machinery/v104/docs/8.6
ns=1;i=1004
ns=1;i=6030
ns=1;i=1011
ns=1;i=1010
ns=1;i=6029
ns=1;i=6015
DefaultInstanceBrowseName
The default BrowseName for instances of the type.
i=68
ns=1;i=1012
2
Identification
Location
To be used by end users to store the location of the machine in a scheme specific to the end user. Servers shall support at least 60 Unicode characters for the clients writing this value, this means clients can expect to be able to write strings with a length of 60 Unicode characters into that field.
i=80
i=68
ns=1;i=1012
ProductInstanceUri
A globally unique resource identifier provided by the manufacturer of the machine
i=78
i=68
ns=1;i=1012
MachineryItemState_StateMachineType
State machine representing the state of a machinery item
Machinery MachineryItem State
https://reference.opcfoundation.org/Machinery/v104/docs/12.2
i=2771
ns=1;i=6021
ns=1;i=5006
ns=1;i=5023
ns=1;i=5020
ns=1;i=5022
ns=1;i=5021
ns=1;i=5010
ns=1;i=5011
ns=1;i=5009
ns=1;i=5008
ns=1;i=5018
ns=1;i=5016
ns=1;i=5019
ns=1;i=5017
ns=1;i=5014
ns=1;i=5012
ns=1;i=5013
ns=1;i=5015
ns=1;i=5005
ns=1;i=5007
ns=1;i=5004
DefaultInstanceBrowseName
The default BrowseName for instances of the type
i=68
ns=1;i=1002
1
MachineryItemState
Executing
The machine is available & functional and is actively performing an activity (pursues a purpose)
i=2307
ns=1;i=1002
ns=1;i=6040
ns=1;i=5010
ns=1;i=5014
ns=1;i=5018
ns=1;i=5020
ns=1;i=5021
ns=1;i=5022
ns=1;i=5023
ns=1;i=5023
StateNumber
i=78
i=68
ns=1;i=5006
3
FromExecutingToExecuting
Transition from state Executing to state Executing
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5006
ns=1;i=6057
TransitionNumber
i=78
i=68
ns=1;i=5023
14
FromExecutingToNotAvailable
Transition from state Executing to state NotAvailable
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5005
ns=1;i=6054
TransitionNumber
i=78
i=68
ns=1;i=5020
6
FromExecutingToNotExecuting
Transition from state Executing to state NotExecuting
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5007
ns=1;i=6056
TransitionNumber
i=78
i=68
ns=1;i=5022
8
FromExecutingToOutOfService
Transition from state Executing to state OutOfService
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5004
ns=1;i=6055
TransitionNumber
i=78
i=68
ns=1;i=5021
7
FromNotAvailableToExecuting
Transition from state NotAvailable to state Executing
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5005
ns=1;i=6044
TransitionNumber
i=78
i=68
ns=1;i=5010
1
FromNotAvailableToNotAvailable
Transition from state NotAvailable to state NotAvailable
i=2310
ns=1;i=1002
ns=1;i=5005
ns=1;i=5005
ns=1;i=6045
TransitionNumber
i=78
i=68
ns=1;i=5011
12
FromNotAvailableToNotExecuting
Transition from state NotAvailable to state NotExecuting
i=2310
ns=1;i=1002
ns=1;i=5005
ns=1;i=5007
ns=1;i=6043
TransitionNumber
i=78
i=68
ns=1;i=5009
2
FromNotAvailableToOutOfService
Transition from state NotAvailable to state OutOfService
i=2310
ns=1;i=1002
ns=1;i=5005
ns=1;i=5004
ns=1;i=6042
TransitionNumber
i=78
i=68
ns=1;i=5008
0
FromNotExecutingToExecuting
Transition from state NotExecuting to state Executing
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5007
ns=1;i=6052
TransitionNumber
i=78
i=68
ns=1;i=5018
11
FromNotExecutingToNotAvailable
Transition from state NotExecuting to state NotAvailable
i=2310
ns=1;i=1002
ns=1;i=5005
ns=1;i=5007
ns=1;i=6050
TransitionNumber
i=78
i=68
ns=1;i=5016
9
FromNotExecutingToNotExecuting
Transition from state NotExecuting to state NotExecuting
i=2310
ns=1;i=1002
ns=1;i=5007
ns=1;i=5007
ns=1;i=6053
TransitionNumber
i=78
i=68
ns=1;i=5019
15
FromNotExecutingToOutOfService
Transition from state NotExecuting to state OutOfService
i=2310
ns=1;i=1002
ns=1;i=5007
ns=1;i=5004
ns=1;i=6051
TransitionNumber
i=78
i=68
ns=1;i=5017
10
FromOutOfServiceToExecuting
Transition from state OutOfService to state Executing
i=2310
ns=1;i=1002
ns=1;i=5006
ns=1;i=5004
ns=1;i=6048
TransitionNumber
i=78
i=68
ns=1;i=5014
4
FromOutOfServiceToNotAvailable
Transition from state OutOfService to state NotAvailable
i=2310
ns=1;i=1002
ns=1;i=5005
ns=1;i=5004
ns=1;i=6046
TransitionNumber
i=78
i=68
ns=1;i=5012
3
FromOutOfServiceToNotExecuting
Transition from state OutOfService to state NotExecuting
i=2310
ns=1;i=1002
ns=1;i=5007
ns=1;i=5004
ns=1;i=6047
TransitionNumber
i=78
i=68
ns=1;i=5013
5
FromOutOfServiceToOutOfService
Transition from state OutOfService to state OutOfService
i=2310
ns=1;i=1002
ns=1;i=5004
ns=1;i=5004
ns=1;i=6049
TransitionNumber
i=78
i=68
ns=1;i=5015
13
NotAvailable
The machine is not available and does not perform any activity (e.g., switched off, in energy saving mode)
i=2307
ns=1;i=1002
ns=1;i=6039
ns=1;i=5008
ns=1;i=5009
ns=1;i=5010
ns=1;i=5011
ns=1;i=5011
ns=1;i=5012
ns=1;i=5016
ns=1;i=5020
StateNumber
i=78
i=68
ns=1;i=5005
0
NotExecuting
The machine is available & functional and does not perform any activity. It waits for an action from outside to start or restart an activity
i=2307
ns=1;i=1002
ns=1;i=6041
ns=1;i=5009
ns=1;i=5013
ns=1;i=5016
ns=1;i=5017
ns=1;i=5018
ns=1;i=5019
ns=1;i=5019
ns=1;i=5022
StateNumber
i=78
i=68
ns=1;i=5007
2
OutOfService
The machine is not functional and does not perform any activity (e.g., error, blocked)
i=2307
ns=1;i=1002
ns=1;i=6038
ns=1;i=5008
ns=1;i=5012
ns=1;i=5013
ns=1;i=5014
ns=1;i=5015
ns=1;i=5015
ns=1;i=5017
ns=1;i=5021
StateNumber
i=78
i=68
ns=1;i=5004
1
MachineryOperationModeStateMachineType
State machine representing the operation mode of a MachineryItem
Machinery Operation Mode
https://reference.opcfoundation.org/Machinery/v104/docs/13.2
i=2771
ns=1;i=6058
ns=1;i=5035
ns=1;i=5032
ns=1;i=5034
ns=1;i=5033
ns=1;i=5028
ns=1;i=5031
ns=1;i=5030
ns=1;i=5029
ns=1;i=5041
ns=1;i=5040
ns=1;i=5043
ns=1;i=5042
ns=1;i=5037
ns=1;i=5036
ns=1;i=5038
ns=1;i=5039
ns=1;i=5025
ns=1;i=5024
ns=1;i=5026
ns=1;i=5027
DefaultInstanceBrowseName
The default BrowseName for instances of the type
i=68
ns=1;i=1008
1
MachineryOperationMode
FromMaintenanceToMaintenance
Transition from state Maintenance to state Maintenance
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5025
ns=1;i=6070
TransitionNumber
i=78
i=68
ns=1;i=5035
13
FromMaintenanceToNone
Transition from state Maintenance to state None
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5024
ns=1;i=6067
TransitionNumber
i=78
i=68
ns=1;i=5032
3
FromMaintenanceToProcessing
Transition from state Maintenance to state Processing
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5026
ns=1;i=6069
TransitionNumber
i=78
i=68
ns=1;i=5034
4
FromMaintenanceToSetup
Transition from state Maintenance to state Setup
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5027
ns=1;i=6068
TransitionNumber
i=78
i=68
ns=1;i=5033
5
FromNoneToMaintenance
Transition from state None to state Maintenance
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5024
ns=1;i=6063
TransitionNumber
i=78
i=68
ns=1;i=5028
0
FromNoneToNone
Transition from state None to state None
i=2310
ns=1;i=1008
ns=1;i=5024
ns=1;i=5024
ns=1;i=6066
TransitionNumber
i=78
i=68
ns=1;i=5031
12
FromNoneToProcessing
Transition from state None to state Processing
i=2310
ns=1;i=1008
ns=1;i=5024
ns=1;i=5026
ns=1;i=6065
TransitionNumber
i=78
i=68
ns=1;i=5030
1
FromNoneToSetup
Transition from state None to state Setup
i=2310
ns=1;i=1008
ns=1;i=5024
ns=1;i=5027
ns=1;i=6064
TransitionNumber
i=78
i=68
ns=1;i=5029
2
FromProcessingToMaintenance
Transition from state Processing to state Maintenance
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5026
ns=1;i=6076
TransitionNumber
i=78
i=68
ns=1;i=5041
7
FromProcessingToNone
Transition from state Processing to state None
i=2310
ns=1;i=1008
ns=1;i=5024
ns=1;i=5026
ns=1;i=6075
TransitionNumber
i=78
i=68
ns=1;i=5040
6
FromProcessingToProcessing
Transition from state Processing to state Processing
i=2310
ns=1;i=1008
ns=1;i=5026
ns=1;i=5026
ns=1;i=6078
TransitionNumber
i=78
i=68
ns=1;i=5043
14
FromProcessingToSetup
Transition from state Processing to state Setup
i=2310
ns=1;i=1008
ns=1;i=5026
ns=1;i=5027
ns=1;i=6077
TransitionNumber
i=78
i=68
ns=1;i=5042
8
FromSetupToMaintenance
Transition from state Setup to state Maintenance
i=2310
ns=1;i=1008
ns=1;i=5025
ns=1;i=5027
ns=1;i=6072
TransitionNumber
i=78
i=68
ns=1;i=5037
10
FromSetupToNone
Transition from state Setup to state None
i=2310
ns=1;i=1008
ns=1;i=5024
ns=1;i=5027
ns=1;i=6071
TransitionNumber
i=78
i=68
ns=1;i=5036
9
FromSetupToProcessing
Transition from state Setup to state Processing
i=2310
ns=1;i=1008
ns=1;i=5026
ns=1;i=5027
ns=1;i=6073
TransitionNumber
i=78
i=68
ns=1;i=5038
11
FromSetupToSetup
Transition from state Setup to state Setup
i=2310
ns=1;i=1008
ns=1;i=5027
ns=1;i=5027
ns=1;i=6074
TransitionNumber
i=78
i=68
ns=1;i=5039
15
Maintenance
MachineryItem is set into maintenance mode with the intention to carry out maintenance or servicing activities
i=2307
ns=1;i=1008
ns=1;i=6060
ns=1;i=5028
ns=1;i=5032
ns=1;i=5033
ns=1;i=5034
ns=1;i=5035
ns=1;i=5035
ns=1;i=5037
ns=1;i=5041
StateNumber
i=78
i=68
ns=1;i=5025
1
None
There is currently no operation mode available
i=2307
ns=1;i=1008
ns=1;i=6059
ns=1;i=5028
ns=1;i=5029
ns=1;i=5030
ns=1;i=5031
ns=1;i=5031
ns=1;i=5032
ns=1;i=5036
ns=1;i=5040
StateNumber
i=78
i=68
ns=1;i=5024
0
Processing
MachineryItem is set into processing mode with the intention to carry out the value adding activities
i=2307
ns=1;i=1008
ns=1;i=6061
ns=1;i=5030
ns=1;i=5034
ns=1;i=5038
ns=1;i=5040
ns=1;i=5041
ns=1;i=5042
ns=1;i=5043
ns=1;i=5043
StateNumber
i=78
i=68
ns=1;i=5026
3
Setup
MachineryItem is set into setup mode with the intention to carry out setup, preparation or postprocessing activities of a production process
i=2307
ns=1;i=1008
ns=1;i=6062
ns=1;i=5029
ns=1;i=5033
ns=1;i=5036
ns=1;i=5037
ns=1;i=5038
ns=1;i=5039
ns=1;i=5039
ns=1;i=5042
StateNumber
i=78
i=68
ns=1;i=5027
2