/* ======================================================================== * Copyright (c) 2005-2025 The OPC Foundation, Inc. All rights reserved. * * OPC Foundation MIT License 1.00 * * Permission is hereby granted, free of charge, to any person * obtaining a copy of this software and associated documentation * files (the "Software"), to deal in the Software without * restriction, including without limitation the rights to use, * copy, modify, merge, publish, distribute, sublicense, and/or sell * copies of the Software, and to permit persons to whom the * Software is furnished to do so, subject to the following * conditions: * * The above copyright notice and this permission notice shall be * included in all copies or substantial portions of the Software. * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES * OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT * HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, * WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING * FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR * OTHER DEALINGS IN THE SOFTWARE. * * The complete license agreement can be found here: * http://opcfoundation.org/License/MIT/1.00/ * ======================================================================*/ using System; using System.Threading; using Microsoft.Extensions.Logging; using Opc.Ua; using Opc.Ua.Pumps; using Opc.Ua.Server.Fluent; namespace Pumps { /// /// Sibling partial that wires per-node callbacks for the /// using the fluent builder. /// Demonstrates the OPC 40223 Pumps companion specification /// with a full simulation loop. /// /// /// The node manager is hand-written and uses the fluent /// API to wire per-node /// callbacks. See for the entry point. /// public partial class PumpNodeManager { /// /// ── Simulation state ──────────────────────────────────────── /// private long m_simulationTicks; private long m_numberOfStarts; /// /// Reference to the hand-rolled Pump #1 instance so the /// simulation tick can mutate its DI properties in response to /// supervision flags. Set by CreatePumpInstanceAsync. /// private Opc.Ua.Pumps.PumpState? m_pump1; /// /// Optional DI DeviceHealth variable supplied by a declarative /// DeviceState device (e.g. Pump #2). Set via /// RegisterSupervisedDeviceHealth and toggled by AdvanceSimulation /// to reflect cavitation / motor-overheat states using the NAMUR /// NE 107 enumeration. /// private BaseDataVariableState? m_supervisedDeviceHealth; /// /// ── Latest simulated values, updated by the simulation tick. ── /// private double m_currentPressure; private double m_currentTemperature = 313.15; private double m_currentBearingTemp = 333.15; private double m_currentPower; private double m_currentFlow; private double m_currentEfficiency = 75.0; private double m_currentLevel = 2.5; private bool m_cavitation; private bool m_motorOverheat; partial void Configure(INodeManagerBuilder builder) { Server.Telemetry.CreateLogger() .LogInformation("Configuring PumpNodeManager fluent wiring..."); WithIdentification(builder); WithMeasurements(builder); WithSupervision(builder); // Single manager-owned simulation tick advances all live // measurements at 250 ms intervals; lets time-based fault // injection work cleanly. builder.Simulation(TimeSpan.FromMilliseconds(250)) .OnTick((ctx, elapsed) => AdvanceSimulation()); } /// /// ── Identification properties via WithProperty ────────────── /// PumpType.Identification is a mandatory child of PumpType so /// it is materialised by the source-generated factory used in /// CreatePumpInstanceAsync. BrowsePathResolver's cross-namespace /// name-only fallback (FB-3 phase 1) resolves the unqualified /// 'Identification' segment to the DI-namespace child without /// requiring an explicit ns= prefix in the path. /// /// private void WithIdentification(INodeManagerBuilder builder) { builder.Node("Pump #1/Identification") .WithProperty("Manufacturer", "SimPump Corp") .WithProperty("SerialNumber", "SN-001") .WithProperty("ProductInstanceUri", "urn:simdevice:SimPump:PumpX-2000:SN-001"); } /// /// ── Measurements with engineering units ───────────────────── /// All seven analog measurements live under /// PumpType.Operational.Measurements and are materialised by /// CreatePumpInstanceAsync via the generator-emitted AddXxx /// helpers. The cross-namespace name-only resolver fallback /// means the unqualified browse path resolves through the /// Pumps -> Machinery (Operational) -> Pumps (Measurements + /// analog states) namespace transitions transparently. /// /// private void WithMeasurements(INodeManagerBuilder builder) { AddMeasurement(builder, "Pump #1/Operational/Measurements/DifferentialPressure", () => m_currentPressure, EngineeringUnits.Pascal, min: 0, max: 1_000_000); AddMeasurement(builder, "Pump #1/Operational/Measurements/FluidTemperature", () => m_currentTemperature, EngineeringUnits.Kelvin, min: 233.15, max: 473.15); AddMeasurement(builder, "Pump #1/Operational/Measurements/BearingTemperature", () => m_currentBearingTemp, EngineeringUnits.Kelvin, min: 233.15, max: 473.15); AddMeasurement(builder, "Pump #1/Operational/Measurements/PumpPowerInput", () => m_currentPower, EngineeringUnits.Watt, min: 0, max: 50_000); AddMeasurement(builder, "Pump #1/Operational/Measurements/MassFlow", () => m_currentFlow, EngineeringUnits.KilogramsPerSecond, min: 0, max: 1.0); AddMeasurement(builder, "Pump #1/Operational/Measurements/PumpEfficiency", () => m_currentEfficiency, EngineeringUnits.Percent, min: 0, max: 100); AddMeasurement(builder, "Pump #1/Operational/Measurements/Level", () => m_currentLevel, EngineeringUnits.Metre, min: 0, max: 10); // Discrete count exposed alongside the analog measurements. builder.Variable( "Pump #1/Operational/Measurements/NumberOfStarts") .OnRead(() => (uint)Interlocked.Read(ref m_numberOfStarts)); } private static class EngineeringUnits { public static readonly EUInformation Pascal = new("Pa", "Pascal", "http://www.opcfoundation.org/UA/units/un/cefact"); public static readonly EUInformation Kelvin = new("K", "Kelvin", "http://www.opcfoundation.org/UA/units/un/cefact"); public static readonly EUInformation Watt = new("W", "Watt", "http://www.opcfoundation.org/UA/units/un/cefact"); public static readonly EUInformation KilogramsPerSecond = new("kg/s", "Kilograms per Second", "http://www.opcfoundation.org/UA/units/un/cefact"); public static readonly EUInformation Percent = new("%", "Percent", "http://www.opcfoundation.org/UA/units/un/cefact"); public static readonly EUInformation Metre = new("m", "Metre", "http://www.opcfoundation.org/UA/units/un/cefact"); } /// /// ── Supervision flags wired to NAMUR alarms ───────────────── /// Demonstrates the FB-3 phase 3 typed accessor API: starting /// from a typed INodeBuilder root, the generator- /// emitted PumpStateComponents.Events extension walks to /// SupervisionState (the type of PumpType.Events), and from /// there the typed SupervisionStateComponents accessor walks /// to SupervisionProcessFluid and SupervisionPumpOperation — /// each step is compile-time checked against the model and /// namespace-aware without forcing the author to spell out /// browse-paths or QualifiedNames. /// /// private void WithSupervision(INodeManagerBuilder builder) { ushort pumpsNs = (ushort)Server.NamespaceUris.GetIndex( Opc.Ua.Pumps.Namespaces.Pumps); Opc.Ua.Server.Fluent.INodeBuilder pump = builder.Node("Pump #1"); IAlarmBuilder tempAlarm = pump .Components().Events() .CreateLimitAlarm(new QualifiedName("OverTempAlarm", pumpsNs)) .WithLimits(highHigh: 373.15, high: 363.15, low: 283.15, lowLow: 273.15) .OnAcknowledge((ctx, c, eventId, comment) => ServiceResult.Good); pump.Components().Events() .Components().SupervisionProcessFluid() .Components().Cavitation() .OnRead(() => m_cavitation) .ActivatesAlarm(tempAlarm); pump.Components().Events() .Components().SupervisionPumpOperation() .Components().MotorOverheat() .OnRead(() => m_motorOverheat); } /// /// Direct measurement wiring — failures now propagate as /// BadNodeIdUnknown ServiceResultException so wiring errors /// surface at configuration time rather than getting silently /// logged. The legacy TryAdd* helpers and their per-method /// try/catch blocks were necessary while the optional pump /// subtree was unmaterialised; CreatePumpInstanceAsync now /// materialises every wired leaf so the wiring is unconditional. /// /// /// /// /// /// /// private static void AddMeasurement( INodeManagerBuilder builder, string browsePath, Func getter, EUInformation units, double min, double max) { builder.Variable(browsePath) .OnRead(getter) .WithEngineeringUnits(units) .WithEURange(min, max); } /// /// ── Simulation tick — advances all live measurements ──────── /// private void AdvanceSimulation() { long t = Interlocked.Increment(ref m_simulationTicks); m_currentPressure = 200000.0 + (50000.0 * Math.Sin(t * 0.03)); m_currentTemperature = 313.15 + (5.0 * Math.Sin(t * 0.01)); m_currentBearingTemp = 333.15 + (8.0 * Math.Cos(t * 0.008)); m_currentPower = 5000.0 + (500.0 * Math.Sin(t * 0.02)); m_currentFlow = 0.05 + (0.005 * Math.Cos(t * 0.04)); m_currentEfficiency = 75.0 + (10.0 * Math.Sin(t * 0.015)); m_currentLevel = 2.5 + (0.5 * Math.Sin(t * 0.02)); // Fault injection — supervision flags transition true/false. m_cavitation = (t % 120) > 100; m_motorOverheat = (t % 200) > 190; // Map the simulated supervision flags onto the DI DeviceHealth // NAMUR NE 107 enumeration. Motor overheat is the more severe // condition so it wins when both are active. The variable is // ClearChangeMasks-ed so subscriptions see each transition. UpdateDeviceHealth(); // Periodic restart simulation — every 3600 ticks (~15 min at 250ms). if (t % 3600 == 0) { Interlocked.Increment(ref m_numberOfStarts); } } /// /// Maps the simulated supervision flags onto the DI /// /// using the NAMUR NE 107 severity order: a motor overheat /// always wins over a cavitation event (FAILURE > /// MAINTENANCE_REQUIRED); when neither flag is set the device /// reports NORMAL. Exposed as a pure function so tests can /// exercise the mapping without instantiating the manager. /// public static Opc.Ua.Di.DeviceHealthEnumeration MapSupervisionToDeviceHealth(bool cavitation, bool motorOverheat) { if (motorOverheat) { return Opc.Ua.Di.DeviceHealthEnumeration.FAILURE; } if (cavitation) { return Opc.Ua.Di.DeviceHealthEnumeration.MAINTENANCE_REQUIRED; } return Opc.Ua.Di.DeviceHealthEnumeration.NORMAL; } private void UpdateDeviceHealth() { BaseDataVariableState? health = m_supervisedDeviceHealth; if (health == null) { return; } Opc.Ua.Di.DeviceHealthEnumeration desired = MapSupervisionToDeviceHealth(m_cavitation, m_motorOverheat); if (health.Value != desired) { health.Value = desired; health.Timestamp = DateTime.UtcNow; health.ClearChangeMasks(SystemContext, includeChildren: false); } } } }