Files
Copilot d525bc3f28 Bound reconnect cleanup and organize samples by domain (#4276)
# Description

This PR fixes bounded ManagedSession reconnect cleanup and reorganizes
the sample applications into domain-focused folders.

## Reconnect cleanup

- Bounds reconnect integration cleanup with independent 30-second close
and dispose limits.
- Sends `CloseSession` through the awaited transport request path during
`Session.DisposeAsync`.
- Preserves explicit `Session.CloseAsync` behavior that waits for or
cancels outstanding publish requests.
- Covers the disposal request path with a regression test.

## Sample organization

- `samples/OpenUsd`: `GeneratorServer`, `SiteCompositionServer`
- `samples/Redundancy`: `RedundantClient`, `RedundantServer`,
`RedundantPubSub`
- `samples/Isa95`: `MinimalIsa95Server`
- `samples/MinimalApi`: `MinimalBoilerServer`, `MinimalCalcServer`,
`MinimalClient`
- `samples/DI`: `PumpDeviceIntegrationServer`
- `samples/Lds`: `ConsoleLdsServer`
- `samples/Reference`: `ConsoleReferenceClient`,
`ConsoleReferenceServer`
- `samples/PubSub`: `ConsoleReferencePubSubClient`

`UA.slnx` now exposes the same requested domain groups. Project
references, tests, runtime sample probes, CI workflows, Dockerfiles,
Compose files, helper scripts, and documentation were updated to the new
paths. `samples/Robotics/MinimalRobotServer` remains under `Robotics`.

## Validation

- `dotnet build UA.slnx`
- 3 Redundancy short-haul sample tests
- 70 DI sample tests
- 914 OpenUSD tests
- 1 WotCon model-materialization test
- 137 AOT tests
- `docker compose config` for all 6 moved Redundancy Compose files

## Related Issues

- Fixes #4273

## Checklist

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce new build or
analyzer warnings.
- [x] I built the complete `UA.slnx` solution locally.
- [ ] I ran all tests locally against at least .NET Framework and .NET
10.
- [ ] I fixed all failing and flaky tests in the CI pipelines and all
CodeQL warnings.
- [x] I have addressed all PR feedback received.

---------

Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com>
Co-authored-by: marcschier <11168470+marcschier@users.noreply.github.com>
Co-authored-by: Marc Schier <mschier@microsoft.com>
Co-authored-by: Marc Schier <marcschier@users.noreply.github.com>
Copilot-Session: a2c2838f-74ae-4997-a1d4-50574d9e0636
2026-08-21 04:35:47 +00:00
..

SiteCompositionServer

A supervisory OPC UA server that owns no devices and composes the machines of several subordinate servers into a single live 3D scene.

This is the SCADA-level counterpart to a device server. Where PumpDeviceIntegrationServer and GeneratorServer each publish their own machines and their own twin, this server publishes a site and says which server owns what.

What it demonstrates

flowchart TD
  C["Opc.Ua.OpenUsd.Connector<br/>--federate"]
  S["SiteCompositionServer<br/>site shell + camera<br/>owns no devices"]
  P["PumpDeviceIntegrationServer<br/>pumps"]
  G["GeneratorServer<br/>generator sets"]

  C -->|"primary session"| S
  S -.->|"ComponentEndpointUrl"| P
  S -.->|"ComponentEndpointUrl"| G
  C ==>|"federated session"| P
  C ==>|"federated session"| G

  C --> STAGE[["one live stage<br/>machines from three servers"]]

The site server declares one cross-server component binding per subordinate, carrying that server's ComponentServerUri and ComponentEndpointUrl. A connector run with --federate opens a session to each named server, discovers its representations and drives its bindings into the same stage.

Nothing is mirrored. The site server never proxies a subordinate's address space: it only says where the machines are and lets the connector talk to each owner directly, so there is no cache to invalidate and no second copy of the truth.

Running it

Start the two device servers, then the site server:

dotnet run --project samples/DI/PumpDeviceIntegrationServer -- --host localhost --port 62542 --pumps 3
dotnet run --project samples/OpenUsd/GeneratorServer -- --host localhost --port 62543 --generators 2
dotnet run --project samples/OpenUsd/SiteCompositionServer -- --host localhost --port 62544

Then render the composed site:

dotnet run --project tools/Opc.Ua.OpenUsd.Connector -- \
    --server opc.tcp://localhost:62544/SiteCompositionServer \
    --insecure --federate --view

--pump-server and --generator-server override the subordinate endpoints.

Why --federate is opt-in

The endpoint the connector dials comes from the server being rendered, not from the operator, so honouring it is a trust decision — a server could name any endpoint it likes. The client library is fail-closed (no session factory, no federation) and the command-line connector mirrors that behind an explicit flag. Federated sessions are negotiated exactly the way the primary session is, so composing a subordinate cannot quietly downgrade security.

Federation is also best-effort per component: a subordinate that is down, unreachable or refuses the session is logged and skipped. The rest of the scene still renders and only that server's machines are missing, because one unreachable subordinate taking down the whole stage would be a poor trade.

What lands where

Each subordinate's machines compose at the prim paths that subordinate publishes — the pump server's pumps under /Plant/..., the generator server's sets under /Powerhouse/... — because the remote connector drives that server's own representation. The /Site/PumpHall and /Site/Powerhouse scopes in Site.usda are the site's own placeholders for those areas.

A verified run against three servers produces one override layer containing:

From In the stage
Pump server /Plant/Pumps/… with live impeller rotation and casing colour
Generator server /Powerhouse/Generators/GeneratorSet_1…N with frequency, power, engine hours, fan rotation and thermal colour
Site server /Site/… shell, lighting and the control-room camera

Files

File Purpose
SiteNodeManager.cs Site topology, OpenUSD facility, cross-server component bindings
Assets/Site.usda Ground, building slabs, lighting, control-room camera — deliberately no machine geometry
Program.cs Host wiring and endpoint arguments

See also