Marc Schier 20d9d65a64 Fix generated configuration namespace resolution (#4019)
# Description

Fix source-generated configuration types whose explicit namespace
references constants emitted by the same generator pass. Roslyn cannot
resolve those constants while `[DataType]` attributes are analyzed, so
the generated XML codec silently fell back to `urn:memorybuffer` /
`urn:testdata` while the shipped configuration uses the model namespace
URIs.

This change:

- adds `MODELGEN021` to fail when an explicitly supplied
`[DataType.Namespace]` expression cannot be resolved;
- uses compile-time-available model namespace URIs for the MemoryBuffer
and TestData configuration types;
- restores production-shaped XML fixtures and exercises the
`UpdateExtension<T>()` / `ParseExtension<T>()` path;
- documents the source-generator namespace requirement and migration
guidance.

Targeted validation passed:

- `TypeGeneratorTests`: 17 tests on `net10.0` and `net48`;
- `ConfigurationRoundTripTests`: 4 tests on `net10.0` and `net48`.

## Related Issues

- Fixes #4014

## Checklist

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [x] I have addressed **all** PR feedback received.
2026-07-18 20:15:49 +02:00
..

Source generation for OPC UA .NET Standard Library

This project uses C# source generators to create parts of the OPC UA .NET Standard Library at compile time. Source generators are a powerful feature in C# that allow developers to generate additional source code during the compilation process, enabling more efficient and maintainable codebases.

The OPC UA source generator is designed to automate working with the OPC UA core library in that it supports several ways to generate code at design time.

  1. Generate all required classes for servers and clients from a given OPC UA information model. The model can be provided in various formats, such as NodeSet2 XML files or Model design xml file.

  2. DataType Generators: These generators create classes and structures that represent OPC UA data types, ensuring that the generated code adheres to the OPC UA specifications.

Generate code from OPC UA Information Models

To generate code from OPC UA information models, you need to include the source generator in your project. This can be done by adding the appropriate NuGet package to your project file.

<PackageReference Include="Opc.Ua.SourceGeneration" Version="x.y.z" />

Once the package is added, you can configure the source generator to process your OPC UA information models. You can do this by adding an ItemGroup to your project file that specifies the model files to be processed.

<ItemGroup>
  <AdditionalFiles Include="Path\To\Your\ModelFile.xml" />
</ItemGroup>

The file to include must be part of your project and have its Build Action set to AdditionalFiles. When you build your project, the source generator will process the specified model files and generate the corresponding C# classes and structures.

Both ModelDesign and NodeSet2 XML files are supported, and they can be combined in one project — a node in one input may reference a type defined in another (for example, instances authored as a ModelDesign whose TypeDefinition points at object types authored as a NodeSet2). Every input is supplied to the others as a resolution dependency, so such cross-model references resolve automatically.

Per-file behaviour is controlled with AdditionalFiles metadata:

Metadata Description
ModelSourceGeneratorModelUri The model (namespace) URI of the input. Required when it cannot be inferred, and used to match the input to a namespace.
ModelSourceGeneratorName Overrides the generated Namespaces class identifier for the model.
ModelSourceGeneratorPrefix Overrides the C# namespace / prefix under which the model's types are generated. For a NodeSet2 input this defaults to a value derived from the model URI — set it explicitly to choose the generated C# namespace. A Prefix declared inside a referencing ModelDesign's <opc:Namespaces> does not rename the referenced model's generated types.
<ItemGroup>
  <AdditionalFiles Include="Model\EquipmentTypes.NodeSet2.xml">
    <ModelSourceGeneratorModelUri>http://example.org/EquipmentTypes</ModelSourceGeneratorModelUri>
    <ModelSourceGeneratorPrefix>Example.EquipmentTypes</ModelSourceGeneratorPrefix>
  </AdditionalFiles>
  <AdditionalFiles Include="Model\Instances.ModelDesign.xml">
    <ModelSourceGeneratorModelUri>http://example.org/EquipmentInstances</ModelSourceGeneratorModelUri>
  </AdditionalFiles>
</ItemGroup>

See Source-Generated NodeManagers for the end-to-end pattern.

Using DataType Generators

The OPC UA source generator includes several data type generators that can be used to create classes by annotating your existing code with specific attributes. Here are some of the available data type generators:

DataTypeAttribute

Generates IEncodeable implementation for your class. Simply annotate your class with the [DataType] attribute to generate the necessary serialization and deserialization code and other required implementation. The [DataContract} and [DataMember] attributes from System.Runtime.Serialization can be used to control the serialization behavior.

[DataType(TypeId = "nsu=http://your-namespace-uri/;i=1000")]
public partial class MyCustomDataType
{
    [DataMember(Order = 1)]
    public int Id { get; set; }
    [DataMember(Order = 2)]
    public string Name { get; set; }
}

IMPORTANT: your class must be a partial class with a default constructor for the source generator to work. Do not implement the IEncodeable interface yourself, as this will conflict with the generated code.

The source generator generates the necessary implementation for the IEncodeable interface, including methods for encoding and decoding the data type. If the type extends another type this type also must be annotated with the [DataType] attribute to be included in the source generation. Only the properties of the annotated type will be part of the generated implementation.

If the structure is abstract the type will be generated as abstract as well.

The following functionality will be implemented over time

  • Record types and structs
  • Support for generating structures with optional fields, option set and union types
  • Support to understand nullable annotation for optional fields
  • Support for generating collection types (arrays, lists, etc.)
  • Support for generating complex types with nested data types. If the type references other data types, these must be built in or implement IEncodeable to be included.

ObjectType client proxies

In addition to data type generation, the source generator emits a strongly typed asynchronous client proxy for every ObjectType defined in the processed model. Each emitted class is named {TypeName}Client and exposes the OPC UA methods declared by that ObjectType as await-able C# methods that internally translate to a CallRequest over an ISessionClient.

Inheritance and shadowing

Generated proxies form an inheritance chain that mirrors the OPC UA type hierarchy:

  • If an ObjectType derives from another ObjectType, its proxy derives from that parent's proxy — even when the parent lives in a different assembly (e.g. DirectoryTypeClient : Opc.Ua.FolderTypeClient).
  • The roots of the chain (types that derive directly from BaseObjectType) ultimately inherit from the hand-authored abstract base Opc.Ua.ObjectTypeClient, which provides the Session, ObjectId, Telemetry properties and the CallMethodAsync helper used by every generated wrapper.
  • When an ObjectType declares a method with the same browse name as an ancestor method but a different signature, the generated wrapper is emitted with the C# new modifier so the derived signature shadows the inherited one.

The standard UA stack ships with proxies for every ObjectType in the core NodeSet (e.g. FileTypeClient, TrustListTypeClient, ServerConfigurationTypeClient, …) emitted into the Opc.Ua namespace, so downstream models can simply derive from them.

For an ergonomic, System.IO-style async client built on top of the generated FileTypeClient / FileDirectoryTypeClient / TemporaryFileTransferTypeClient proxies, see docs/FileSystemClient.md.

Output namespace

By default each model emits its proxies into its own namespace — the C# prefix of the model's target namespace. For example:

Model Proxy namespace
Standard UA Opc.Ua
GDS Opc.Ua.Gds
Custom NodeSet matches the model's target namespace prefix

To redirect proxy emission to a different namespace, set the ModelSourceGeneratorObjectTypeProxyNamespace MSBuild property.

MSBuild properties

The proxy generator is controlled by the following MSBuild properties on the consuming project:

Property Description
ModelSourceGeneratorOmitObjectTypeProxies Set to true to suppress emission of *TypeClient proxies. By default proxies are emitted for every ObjectType in the model alongside the standard model output (constants, NodeIds, NodeStates, DataTypes, schemas).
ModelSourceGeneratorObjectTypeProxyNamespace Optional. Overrides the C# namespace used for the emitted proxy classes. Defaults to the model's own namespace.
ModelSourceGeneratorUseTypeDefinitionModellingRules Set to true to make instance code generation use the modelling rules from the referenced type definition unconditionally, rather than the overridden rules on the instance. Off by default; enabled by default for stack generation. Note: regardless of this setting, the generator always enforces OPC UA modelling rule promotion semantics — instances may only promote the type definition's rule (Optional→Mandatory, OptionalPlaceholder→Mandatory|MandatoryPlaceholder, MandatoryPlaceholder→Mandatory); demotions are silently rejected.

Example (suppress proxy emission for a model that does not need them):

<PropertyGroup>
  <ModelSourceGeneratorOmitObjectTypeProxies>true</ModelSourceGeneratorOmitObjectTypeProxies>
</PropertyGroup>

Implementation details

The source generator is implemented using the Roslyn API,which provides a rich set of tools for analyzing and generating C# code. The generator finds all marker attributes such as [DataType] in your code and builds the model design from it. It then processes the model design to generate the necessary C# code. The annotated types are grouped by namespace. Each namespace will result in a separate generated file. A namespace can be annotated with a namespace URI which