mirror of
https://github.com/OPCFoundation/UA-.NETStandard.git
synced 2026-10-18 22:55:08 +08:00
ca89ac85a7
# Description Adds a **Generators companion-specification sample** alongside the existing pump sample, and a **`SiteCompositionServer`** that composes several device servers into one OpenUSD scene at a supervisory level — demonstrating that servers can be aggregated without mirroring their address spaces. Three things, in dependency order: ### 1. `GeneratorServer` A self-contained server realising the draft Generators spec (`http://opcfoundation.org/UA/Generators/`) end to end: N simulated generating sets, DI + Machinery integration, a twelve-state operating state machine, four protection alarms per set, six control methods, and a per-set OpenUSD twin. The organising idea is that **load fraction is the only independent variable**. Everything else is a function of it: ``` V̇_f(x) = 3.67 + 100·x fuel rate [L/h] η(x) = P(x) / (V̇_f(x) · ρ · LHV) efficiency S = P / PF I = S / (√3·V_LL) f = N·p / 120 ``` This is not stylistic. When each measurement is an independent oscillator — as the pump sample's simulation once was — a server happily publishes a duty point no real machine could occupy, and no test can catch it because there is nothing for the values to be inconsistent *with*. Deriving them from one variable means `P = √3·V·I·PF` and `η = P/(V̇·ρ·LHV)` hold at every tick by construction. The published `DATASHEET.md`, the engineering ranges, the trip points and the simulation all read the same constants in `GeneratorDatasheet.cs`, so the document and the server cannot describe different machines. The machine is a fictitious **SimGen Systems GenX-500** (400 kW prime / 440 kW standby, 400/230 V, 50 Hz, four-pole). Figures are representative of a real industrial genset class; no vendor is named anywhere in the code or docs. ### 2. Cross-server composition in the connector `RemoteSessionFactory` already existed in the client library but the connector CLI never set it, so cross-server composition was unreachable. `--federate` wires it up: the connector opens a session to each server named by a component binding, discovers its representations and drives its bindings into the same stage. It is **opt-in** because the endpoint the connector dials comes from the server being rendered rather than from the operator, which makes honouring it a trust decision. Federation is best-effort per component — a subordinate that is down is logged and skipped, and the rest of the scene still renders — which is the only `src/` change in this PR. ### 3. `SiteCompositionServer` Owns no devices. It publishes a site stage plus one cross-server component binding per subordinate, carrying that server's `ComponentServerUri` and `ComponentEndpointUrl`. Nothing is mirrored, so there is no cache to invalidate and no second copy of the truth. ## Notes for reviewers **Everything interesting in this PR was found by running the servers, not by reading the code.** Six defects, none of which looked wrong in review: - `IsShutdown` and `SubsystemName` are *optional* on `GeneratorProtectionAlarmType`, so the generated factory does not materialise them. `CreateOrReplace` alone produces a child that exists, appears in `GetChildren` and holds the right value — but carries **no `ReferenceTypeId`**, so no browse can reach it. Every alarm was publishing its trip without saying whether the trip stops the machine or which subsystem to go to. `AddXxx(context)` first is what gives the child its `HasProperty` reference. - **The protections could never fire.** Every trip point sits outside the band the datasheet curves produce — that is what a datasheet *means* — so all four alarms, the shutdown class, `ResetFaults` and the whole `Fault` branch of the state machine were unreachable while the README documented them as observable. Overload was worse: the load clamp ceiling was set to exactly the trip point, making a strictly-greater-than comparison unsatisfiable. Faults are now injectable, and the first set — the one the hero camera frames — develops one on a slow rotation. - **A shutdown trip removes the condition that caused it**, because oil pressure and coolant temperature are only supervised while the engine turns. Each alarm went active for one tick and cleared, leaving an operator with a stopped machine and no indication of why. Shutdown-class alarms now latch until the set leaves the shutdown state. Every unit test that checked the *condition* passed throughout — the defect only appears when the trip and the supervision interact over time. - **`Synchronizing` and `Paralleled` were declared, drawn in the README and never entered.** The first set now energises a dead bus and closes onto it while every other set synchronises to a live one — both how a real plant parallels, and what makes the two states observable. - **The tick raced client method calls.** The simulation tick runs on a thread-pool thread while method calls arrive on request threads, and both transition sets and write the same nodes. A tick moving a set to `Cooldown` and a concurrent `EmergencyStop` could interleave the paired `CurrentState` / `CurrentState.Id` writes and leave a client with a state *name* from one transition and a state *node* from the other — the exact failure the paired write exists to prevent, reintroduced by the threading model. Both paths now take one gate. - Low oil pressure supervised from raw speed **tripped every set during cranking**, because pressure has not built yet. Now gated on `IsSpinning`, which is what a real start-up bypass does. Smaller fixes: shutdown trips are applied after the whole evaluation pass (stopping mid-loop made the remaining conditions read healthy, collapsing simultaneous trips to whichever came first in the table); `ResetFaults` reports its clears as events (a client learns of condition state changes only through events, so a silent clear leaves an alarm-list client showing it forever); the start counter moved into the transition so commanded starts are counted; the federated connector closes the remote session if the connector constructor throws between taking ownership and registering it; and `prepare_machinery_nodeset.py` now *asserts* the IA namespace is last before removing it rather than only claiming so in its docstring — removing any earlier entry would silently renumber every namespace after it and rebind their NodeIds. **A model limitation is left visible rather than papered over.** `GeneratorStateMachineType` declares an emergency stop only out of `Running`, `Loaded` and `Paralleled`, so the sample refuses `EmergencyStop` from `Starting` and `Warmup`. A real panel stops from anywhere. That is the specification's shape, not this sample's choice, so it is pinned by a test and named in the docs. **`Model/` vendors a reduced Machinery nodeset**, derived mechanically by whitelist. The full official nodeset does not survive the model source generator (`MODELGEN003`) and drags in IA through a single optional `Stacklight` member a generating set does not have. Deriving it by script keeps the provenance checkable; the whitelist is the only thing to edit when more types are needed. **Never hand-edit the generated output.** **The federated scene renders end to end.** Getting there surfaced three more defects, all of which produced a plausible-looking scene with nothing in it: the generator sample's plant aggregation was created under an already-registered `DeviceSet` and so was invisible to every client (it had *never* rendered geometry, standalone or federated); the connector's asset fetch ran on the primary session only, so composition referenced layers that were never downloaded; and both generator colour bindings wrote `primvars:displayColor` to prims that did not declare it, so the renderer rejected every update while the file still looked correct. Cross-server components compose under the subordinate's own root, so the site layer now *places* `/Plant` and `/Powerhouse` rather than leaving them stacked on the origin. **`OpenUsdRepresentation` is now mounted with `HasAddIn`, not `HasComponent`** (review feedback). The nodeset says so explicitly — *"Mounted with HasAddIn"* — but every server in the tree used plain `HasComponent`. It survived because `HasAddIn` is a *subtype* of `HasComponent`: the representation still browses, still aggregates and still drives a twin, so every functional test passed before the fix and after it, and only a conformance checker could tell. Seven mount sites corrected. `PumpDeviceIntegrationServer` and `MinimalRobotServer` had hand-rolled the mount instead of calling the shared `CreateRepresentation` helper, which is exactly how they drifted from it. Both sample E2E suites now assert the reference type across **every** discovered representation — a narrower check would have missed the plant-level representation that arrived later from master still carrying `HasComponent`. **Live colour is not achievable in the current OpenUSD viewer, and that is now documented rather than worked around.** Proven with a standalone probe: `primvars:displayColor` resolves as `color3f[]` from the `UsdGeomGprim` schema whatever the layer declares, and the `OpenUsd 0.4.0-alpha` managed API has no writer for that type. Bound `UsdPreviewSurface` materials are not shaded either, so geometry renders grey unless it also carries an explicit `displayColor` primvar. The **visibility** bindings carry no such caveat and are what the samples rely on to show state. Filed upstream as [openusd-dotnet#2](https://github.com/marcschier/openusd-dotnet/issues/2), [#3](https://github.com/marcschier/openusd-dotnet/issues/3) and [#4](https://github.com/marcschier/openusd-dotnet/issues/4), and linked from `docs/OpenUsd.md` so a reader can check whether they have since been fixed. ## Related Issues No tracking issue — this is additive sample and documentation work with a single small, self-contained change to `src/` (per-component error isolation and session-ownership hardening in `OpenUsdConnector.Composition.cs`). Happy to open one if maintainers would prefer it tracked. ## Checklist - [x] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [x] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. ### Testing The generator fixtures live in `tests/Opc.Ua.OpenUsd.Tests/Generator` — **82 tests**, no new project. `Opc.Ua.Di.Tests` would have been the natural home next to the pump fixtures, but both device samples source-generate their own reduced `Opc.Ua.Machinery` model and expose it via `InternalsVisibleTo`, so referencing both from one assembly makes every Machinery type ambiguous (CS0433); `Opc.Ua.OpenUsd.Tests` references no other sample and already hosts `RobotAssetContractTests`. The suite runs **870** on net10.0 and net48 (784 existing + 86) and **788** on net472, where the sample does not exist and only the framework-independent asset-contract tests run — forgetting exactly that exclusion broke CI on the sibling pump PR. The tests target the things in this sample that fail *quietly*: - **Datasheet conformance** holds the model to its own claim — rated speed is `120·f/p`, rated current follows from the rating, the fuel curve reproduces the published table, and `η = P/(V̇·ρ·LHV)` reconciles at every load. Efficiency is swept across the whole simulated range to show it stays inside (0,100) and rises monotonically; a fit that goes negative somewhere in its range is a coincidence that happens to look right at the duty point, not a model. A further test reads `DATASHEET.md` and checks the document quotes the figures the server actually serves. - **Drift between the two descriptions of the state machine** — the physics' `IsLegalTransition` and the model's `GeneratorStateMap` — is checked in *both* directions. A transition the physics permits but the map lacks moves a machine without telling a client; one the map holds but the physics refuses is dead weight that looks supported. - **Reachability at run time**, not just in the declared table — the test that catches states the model declares and nothing ever enters. - **That every protection can actually fire**, which is the half of the alarm contract that "a healthy set annunciates nothing" does not cover. A **hosted end-to-end fixture** connects a real client and asserts what the address space actually exposes — the aggregation at `/Powerhouse/Generators`, its component binding, and every per-set twin. That is the only kind of test that catches the registration defect above: the node object had the right browse name, binding and asset reference, so every test that inspected objects passed while no client could see it. **Every state-machine and protection fix was checked by mutation.** Restoring the clamp ceiling, the direct `Running → Loaded` path, the old start-counter placement, or removing the alarm opt-in each makes the corresponding test fail, naming the specific defect. A test that has never been seen to fail has not been shown to work. Verified against a running plant: `Synchronizing`, `Paralleled` and `Fault` all observed on a two-set server, with `HighCoolantTemperatureAlarm` seen active on the fault subject. Method behaviour verified separately — per-set distinct `CurrentState` nodes, `EmergencyStop` → `EmergencyStopped` with `Start` then refused as `BadInvalidState`, `ResetFaults` → `Off`, `SetOperatingMode(9999)` refused with the mode unchanged, and the other sets untouched throughout. Also verified as a three-server federated stage. 0 warnings on a clean Release rebuild of both samples, the client library, the connector and the tests, across every TFM. --------- Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com> Copilot-Session: fe608993-f3c9-4779-a6b9-9a9eabfc24ba
605 lines
22 KiB
C#
605 lines
22 KiB
C#
/* ========================================================================
|
|
* Copyright (c) 2005-2025 The OPC Foundation, Inc. All rights reserved.
|
|
*
|
|
* OPC Foundation MIT License 1.00
|
|
*
|
|
* Permission is hereby granted, free of charge, to any person
|
|
* obtaining a copy of this software and associated documentation
|
|
* files (the "Software"), to deal in the Software without
|
|
* restriction, including without limitation the rights to use,
|
|
* copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
* copies of the Software, and to permit persons to whom the
|
|
* Software is furnished to do so, subject to the following
|
|
* conditions:
|
|
*
|
|
* The above copyright notice and this permission notice shall be
|
|
* included in all copies or substantial portions of the Software.
|
|
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
|
|
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
|
|
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
|
|
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
|
|
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
|
|
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
|
|
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
|
|
* OTHER DEALINGS IN THE SOFTWARE.
|
|
*
|
|
* The complete license agreement can be found here:
|
|
* http://opcfoundation.org/License/MIT/1.00/
|
|
* ======================================================================*/
|
|
|
|
using System;
|
|
|
|
namespace Generators
|
|
{
|
|
/// <summary>
|
|
/// The GenX-500 product datasheet as compile-time constants.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// This is the single source of truth shared by <c>DATASHEET.md</c>, the
|
|
/// address space (nameplate, engineering ranges, trip points), the simulation
|
|
/// and the conformance tests. Changing a value here moves the published model,
|
|
/// the simulated behaviour and the OpenUSD gauges together, and
|
|
/// <c>GeneratorDatasheetConformanceTests</c> fails if the document and these
|
|
/// constants ever disagree.
|
|
/// </para>
|
|
/// <para>
|
|
/// The machine is fictitious. Its parameters are ordinary engineering values
|
|
/// for a mid-size industrial diesel generating set - a 50 Hz, four-pole,
|
|
/// 1500 min-1 set in the 400 kW prime class on a turbocharged and aftercooled
|
|
/// inline-six - chosen so the simulation is physically self-consistent rather
|
|
/// than to represent any particular product.
|
|
/// </para>
|
|
/// <para>
|
|
/// Units here are the datasheet's own engineering units (kW, bar, degrees
|
|
/// Celsius, litres per hour). OPC UA publishes SI, so the node manager
|
|
/// converts on the way out; see <see cref="Convert"/>.
|
|
/// </para>
|
|
/// </remarks>
|
|
internal static class GeneratorDatasheet
|
|
{
|
|
/// <summary>
|
|
/// Nameplate identity.
|
|
/// </summary>
|
|
public static class Identity
|
|
{
|
|
/// <summary>
|
|
/// Manufacturer name carried by the DI and Machinery nameplates.
|
|
/// </summary>
|
|
public const string Manufacturer = "SimGen Systems";
|
|
|
|
/// <summary>
|
|
/// Marketing model designation.
|
|
/// </summary>
|
|
public const string Model = "GenX-500";
|
|
|
|
/// <summary>
|
|
/// Manufacturer's product page, used as ManufacturerUri.
|
|
/// </summary>
|
|
public const string ManufacturerUri = "https://simgen.example.com";
|
|
|
|
/// <summary>
|
|
/// Orderable product code.
|
|
/// </summary>
|
|
public const string ProductCode = "GX500-400-50-4W";
|
|
|
|
/// <summary>
|
|
/// Hardware revision of the skid and driveline.
|
|
/// </summary>
|
|
public const string HardwareRevision = "3.1";
|
|
|
|
/// <summary>
|
|
/// Controller firmware revision.
|
|
/// </summary>
|
|
public const string SoftwareRevision = "5.4.2";
|
|
|
|
/// <summary>
|
|
/// Combined device revision reported through DI.
|
|
/// </summary>
|
|
public const string DeviceRevision = "3.1/5.4.2";
|
|
|
|
/// <summary>
|
|
/// Device class reported through the Machinery identification add-in.
|
|
/// </summary>
|
|
public const string DeviceClass = "GeneratingSet";
|
|
|
|
/// <summary>
|
|
/// Year the set left the factory.
|
|
/// </summary>
|
|
public const ushort YearOfConstruction = 2025;
|
|
|
|
/// <summary>
|
|
/// Month the set left the factory.
|
|
/// </summary>
|
|
public const byte MonthOfConstruction = 4;
|
|
}
|
|
|
|
/// <summary>
|
|
/// ISO 8528 duty ratings.
|
|
/// </summary>
|
|
public static class Ratings
|
|
{
|
|
/// <summary>
|
|
/// Prime power (PRP): unlimited hours at variable load, in watts.
|
|
/// </summary>
|
|
public const double PrimePowerWatts = 400_000.0;
|
|
|
|
/// <summary>
|
|
/// Prime apparent power, in volt-amperes.
|
|
/// </summary>
|
|
public const double PrimeApparentPowerVoltAmperes =
|
|
PrimePowerWatts / Electrical.RatedPowerFactor;
|
|
|
|
/// <summary>
|
|
/// Standby power (ESP): emergency use at varying load, in watts.
|
|
/// </summary>
|
|
public const double StandbyPowerWatts = 440_000.0;
|
|
|
|
/// <summary>
|
|
/// Standby apparent power, in volt-amperes.
|
|
/// </summary>
|
|
public const double StandbyApparentPowerVoltAmperes =
|
|
StandbyPowerWatts / Electrical.RatedPowerFactor;
|
|
|
|
/// <summary>
|
|
/// Reference ambient temperature the ratings assume, in degrees Celsius.
|
|
/// </summary>
|
|
public const double ReferenceAmbientCelsius = 25.0;
|
|
|
|
/// <summary>
|
|
/// Reference site altitude the ratings assume, in metres.
|
|
/// </summary>
|
|
public const double ReferenceAltitudeMetres = 150.0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Alternator and electrical system.
|
|
/// </summary>
|
|
public static class Electrical
|
|
{
|
|
/// <summary>
|
|
/// Nominal line-to-line voltage, in volts.
|
|
/// </summary>
|
|
public const double RatedLineVoltage = 400.0;
|
|
|
|
/// <summary>
|
|
/// Nominal line-to-neutral voltage, in volts.
|
|
/// </summary>
|
|
public const double RatedPhaseVoltage = 230.0;
|
|
|
|
/// <summary>
|
|
/// Rated power factor, lagging.
|
|
/// </summary>
|
|
public const double RatedPowerFactor = 0.8;
|
|
|
|
/// <summary>
|
|
/// Nominal output frequency, in hertz.
|
|
/// </summary>
|
|
public const double RatedFrequency = 50.0;
|
|
|
|
/// <summary>
|
|
/// Number of alternator poles.
|
|
/// </summary>
|
|
public const int Poles = 4;
|
|
|
|
/// <summary>
|
|
/// Number of phases.
|
|
/// </summary>
|
|
public const int Phases = 3;
|
|
|
|
/// <summary>
|
|
/// Rated line current at prime power and rated power factor, in amperes.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// I = S / (sqrt(3) * V_LL). Computed rather than tabulated so it can
|
|
/// never drift away from the rating it is derived from.
|
|
/// </remarks>
|
|
public static double RatedCurrentAmperes =>
|
|
Ratings.PrimeApparentPowerVoltAmperes / (Math.Sqrt(3.0) * RatedLineVoltage);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Engine mechanical data.
|
|
/// </summary>
|
|
public static class Engine
|
|
{
|
|
/// <summary>
|
|
/// Rated engine speed, in revolutions per minute.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// Fixed by the pole count and the output frequency:
|
|
/// N = 120 * f / p = 120 * 50 / 4.
|
|
/// </remarks>
|
|
public const double RatedSpeedRpm =
|
|
120.0 * Electrical.RatedFrequency / Electrical.Poles;
|
|
|
|
/// <summary>
|
|
/// Number of cylinders.
|
|
/// </summary>
|
|
public const int Cylinders = 6;
|
|
|
|
/// <summary>
|
|
/// Swept volume, in litres.
|
|
/// </summary>
|
|
public const double DisplacementLitres = 12.5;
|
|
|
|
/// <summary>
|
|
/// Cylinder bore, in millimetres.
|
|
/// </summary>
|
|
public const double BoreMillimetres = 130.0;
|
|
|
|
/// <summary>
|
|
/// Piston stroke, in millimetres.
|
|
/// </summary>
|
|
public const double StrokeMillimetres = 157.0;
|
|
|
|
/// <summary>
|
|
/// Compression ratio.
|
|
/// </summary>
|
|
public const double CompressionRatio = 16.5;
|
|
|
|
/// <summary>
|
|
/// Oil pressure at rated speed and normal temperature, in bar.
|
|
/// </summary>
|
|
public const double RatedOilPressureBar = 4.8;
|
|
|
|
/// <summary>
|
|
/// Coolant thermostat opening temperature, in degrees Celsius.
|
|
/// </summary>
|
|
public const double ThermostatCelsius = 82.0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Fuel system and consumption.
|
|
/// </summary>
|
|
public static class Fuel
|
|
{
|
|
/// <summary>
|
|
/// Usable capacity of the base tank, in litres.
|
|
/// </summary>
|
|
public const double TankCapacityLitres = 1000.0;
|
|
|
|
/// <summary>
|
|
/// Density of the reference diesel fuel, in kilograms per litre.
|
|
/// </summary>
|
|
public const double DensityKilogramsPerLitre = 0.832;
|
|
|
|
/// <summary>
|
|
/// Lower heating value of the reference diesel fuel, in megajoules per kilogram.
|
|
/// </summary>
|
|
public const double LowerHeatingValueMegajoulesPerKilogram = 42.7;
|
|
|
|
/// <summary>
|
|
/// Usable energy per litre of fuel, in kilowatt-hours.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// (MJ/kg * kg/L) / 3.6 MJ per kWh.
|
|
/// </remarks>
|
|
public const double EnergyPerLitreKilowattHours =
|
|
LowerHeatingValueMegajoulesPerKilogram * DensityKilogramsPerLitre / 3.6;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Physical envelope.
|
|
/// </summary>
|
|
public static class Dimensions
|
|
{
|
|
/// <summary>
|
|
/// Overall length of the skid, in metres.
|
|
/// </summary>
|
|
public const double LengthMetres = 4.00;
|
|
|
|
/// <summary>
|
|
/// Overall width of the skid, in metres.
|
|
/// </summary>
|
|
public const double WidthMetres = 1.50;
|
|
|
|
/// <summary>
|
|
/// Overall height of the set, in metres.
|
|
/// </summary>
|
|
public const double HeightMetres = 2.20;
|
|
|
|
/// <summary>
|
|
/// Dry mass, in kilograms.
|
|
/// </summary>
|
|
public const double DryMassKilograms = 4500.0;
|
|
|
|
/// <summary>
|
|
/// Sound pressure level at one metre with the enclosure fitted, in decibels A.
|
|
/// </summary>
|
|
public const double SoundPressureDecibelsA = 75.0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// The published characteristic curves.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// Load fraction is the only independent variable in the simulation.
|
|
/// Everything the set reports follows from these curves, which is what
|
|
/// keeps the published values mutually consistent at every tick.
|
|
/// </remarks>
|
|
public static class Curves
|
|
{
|
|
/// <summary>
|
|
/// No-load intercept of the fuel-consumption curve, in litres per hour.
|
|
/// </summary>
|
|
public const double FuelNoLoadLitresPerHour = 3.67;
|
|
|
|
/// <summary>
|
|
/// Slope of the fuel-consumption curve, in litres per hour at full load.
|
|
/// </summary>
|
|
public const double FuelSlopeLitresPerHour = 100.0;
|
|
|
|
/// <summary>
|
|
/// Coolant temperature rise from thermostat to full load, in kelvin.
|
|
/// </summary>
|
|
public const double CoolantRiseKelvin = 13.0;
|
|
|
|
/// <summary>
|
|
/// Exhaust temperature at no load, in degrees Celsius.
|
|
/// </summary>
|
|
public const double ExhaustNoLoadCelsius = 250.0;
|
|
|
|
/// <summary>
|
|
/// Exhaust temperature rise from no load to full load, in kelvin.
|
|
/// </summary>
|
|
public const double ExhaustRiseKelvin = 300.0;
|
|
|
|
/// <summary>
|
|
/// Fuel consumption at a given load fraction, in litres per hour.
|
|
/// </summary>
|
|
/// <param name="loadFraction">
|
|
/// Electrical output as a fraction of prime power.
|
|
/// </param>
|
|
/// <returns>
|
|
/// Volumetric fuel rate in litres per hour.
|
|
/// </returns>
|
|
public static double FuelLitresPerHour(double loadFraction)
|
|
{
|
|
return FuelNoLoadLitresPerHour + (FuelSlopeLitresPerHour * loadFraction);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Electrical efficiency at a given load fraction, in percent.
|
|
/// </summary>
|
|
/// <param name="loadFraction">
|
|
/// Electrical output as a fraction of prime power.
|
|
/// </param>
|
|
/// <returns>
|
|
/// Fuel-to-electricity conversion efficiency in percent, or zero when the
|
|
/// set is not producing power.
|
|
/// </returns>
|
|
/// <remarks>
|
|
/// The identity that makes the model self-consistent:
|
|
/// eta = P / (Vdot * rho * LHV). Because both P and Vdot are functions of
|
|
/// the same load fraction, the published efficiency always reconciles with
|
|
/// the published power and fuel rate.
|
|
/// </remarks>
|
|
public static double EfficiencyPercent(double loadFraction)
|
|
{
|
|
if (loadFraction <= 0.0)
|
|
{
|
|
return 0.0;
|
|
}
|
|
double outputKilowatts = loadFraction * Ratings.PrimePowerWatts / 1000.0;
|
|
double inputKilowatts =
|
|
FuelLitresPerHour(loadFraction) * Fuel.EnergyPerLitreKilowattHours;
|
|
return 100.0 * outputKilowatts / inputKilowatts;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Coolant temperature at a given load fraction, in degrees Celsius.
|
|
/// </summary>
|
|
/// <param name="loadFraction">
|
|
/// Electrical output as a fraction of prime power.
|
|
/// </param>
|
|
/// <returns>
|
|
/// Jacket-water temperature in degrees Celsius.
|
|
/// </returns>
|
|
public static double CoolantCelsius(double loadFraction)
|
|
{
|
|
return Engine.ThermostatCelsius + (CoolantRiseKelvin * loadFraction);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Exhaust gas temperature at a given load fraction, in degrees Celsius.
|
|
/// </summary>
|
|
/// <param name="loadFraction">
|
|
/// Electrical output as a fraction of prime power.
|
|
/// </param>
|
|
/// <returns>
|
|
/// Exhaust temperature in degrees Celsius.
|
|
/// </returns>
|
|
public static double ExhaustCelsius(double loadFraction)
|
|
{
|
|
return ExhaustNoLoadCelsius + (ExhaustRiseKelvin * loadFraction);
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Protection trip points.
|
|
/// </summary>
|
|
public static class TripPoints
|
|
{
|
|
/// <summary>
|
|
/// Low oil pressure shutdown, in bar.
|
|
/// </summary>
|
|
public const double LowOilPressureBar = 1.7;
|
|
|
|
/// <summary>
|
|
/// High coolant temperature shutdown, in degrees Celsius.
|
|
/// </summary>
|
|
public const double HighCoolantCelsius = 98.0;
|
|
|
|
/// <summary>
|
|
/// Overspeed shutdown, in revolutions per minute.
|
|
/// </summary>
|
|
public const double OverspeedRpm = 1.15 * Engine.RatedSpeedRpm;
|
|
|
|
/// <summary>
|
|
/// Overload alarm, as a fraction of prime power.
|
|
/// </summary>
|
|
public const double OverloadFraction = 1.10;
|
|
|
|
/// <summary>
|
|
/// Low fuel level warning, in percent of tank capacity.
|
|
/// </summary>
|
|
public const double LowFuelPercent = 15.0;
|
|
|
|
/// <summary>
|
|
/// Low battery voltage warning, in volts.
|
|
/// </summary>
|
|
public const double LowBatteryVolts = 22.0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Engineering ranges published as EURange on the measured variables.
|
|
/// </summary>
|
|
public static class Ranges
|
|
{
|
|
/// <summary>
|
|
/// Upper bound of the real-power range, in watts.
|
|
/// </summary>
|
|
public const double RealPowerMaxWatts = 550_000.0;
|
|
|
|
/// <summary>
|
|
/// Lower bound of the frequency range, in hertz.
|
|
/// </summary>
|
|
public const double FrequencyMinHertz = 45.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the frequency range, in hertz.
|
|
/// </summary>
|
|
public const double FrequencyMaxHertz = 55.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the voltage range, in volts.
|
|
/// </summary>
|
|
public const double VoltageMaxVolts = 480.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the current range, in amperes.
|
|
/// </summary>
|
|
public const double CurrentMaxAmperes = 800.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the engine-speed range, in revolutions per minute.
|
|
/// </summary>
|
|
public const double SpeedMaxRpm = 2000.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the coolant-temperature range, in degrees Celsius.
|
|
/// </summary>
|
|
public const double CoolantMaxCelsius = 120.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the exhaust-temperature range, in degrees Celsius.
|
|
/// </summary>
|
|
public const double ExhaustMaxCelsius = 700.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the oil-pressure range, in bar.
|
|
/// </summary>
|
|
public const double OilPressureMaxBar = 8.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the fuel-rate range, in litres per hour.
|
|
/// </summary>
|
|
public const double FuelRateMaxLitresPerHour = 120.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the battery-voltage range, in volts.
|
|
/// </summary>
|
|
public const double BatteryVoltageMaxVolts = 32.0;
|
|
|
|
/// <summary>
|
|
/// Upper bound of the load-percent range.
|
|
/// </summary>
|
|
public const double LoadPercentMax = 120.0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Nominal values the simulation starts from and returns to.
|
|
/// </summary>
|
|
public static class Simulation
|
|
{
|
|
/// <summary>
|
|
/// Nominal battery voltage of the starting system, in volts.
|
|
/// </summary>
|
|
public const double BatteryVolts = 24.0;
|
|
|
|
/// <summary>
|
|
/// Ambient air temperature, in degrees Celsius.
|
|
/// </summary>
|
|
public const double AmbientCelsius = 25.0;
|
|
|
|
/// <summary>
|
|
/// Fuel level the tank starts at, in percent of capacity.
|
|
/// </summary>
|
|
public const double InitialFuelPercent = 88.0;
|
|
|
|
/// <summary>
|
|
/// Load fraction the sets settle around when loaded.
|
|
/// </summary>
|
|
public const double NominalLoadFraction = 0.72;
|
|
|
|
/// <summary>
|
|
/// Peak-to-peak load swing about the nominal load fraction.
|
|
/// </summary>
|
|
public const double LoadSwingFraction = 0.18;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Conversions between the datasheet's engineering units and the SI units
|
|
/// OPC UA publishes.
|
|
/// </summary>
|
|
public static class Convert
|
|
{
|
|
/// <summary>
|
|
/// Zero degrees Celsius expressed in kelvin.
|
|
/// </summary>
|
|
public const double KelvinOffset = 273.15;
|
|
|
|
/// <summary>
|
|
/// Pascals per bar.
|
|
/// </summary>
|
|
public const double PascalsPerBar = 100_000.0;
|
|
|
|
/// <summary>
|
|
/// Seconds per hour.
|
|
/// </summary>
|
|
public const double SecondsPerHour = 3600.0;
|
|
|
|
/// <summary>
|
|
/// Converts degrees Celsius to kelvin.
|
|
/// </summary>
|
|
/// <param name="celsius">Temperature in degrees Celsius.</param>
|
|
/// <returns>Temperature in kelvin.</returns>
|
|
public static double ToKelvin(double celsius)
|
|
{
|
|
return celsius + KelvinOffset;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Converts bar to pascal.
|
|
/// </summary>
|
|
/// <param name="bar">Pressure in bar.</param>
|
|
/// <returns>Pressure in pascal.</returns>
|
|
public static double ToPascal(double bar)
|
|
{
|
|
return bar * PascalsPerBar;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Converts litres per hour to cubic metres per second.
|
|
/// </summary>
|
|
/// <param name="litresPerHour">Volumetric rate in litres per hour.</param>
|
|
/// <returns>Volumetric rate in cubic metres per second.</returns>
|
|
public static double ToCubicMetresPerSecond(double litresPerHour)
|
|
{
|
|
return litresPerHour / 1000.0 / SecondsPerHour;
|
|
}
|
|
}
|
|
}
|
|
}
|