Marc Schier ca89ac85a7 Add a Generators companion-spec sample and compose servers at a site level (#4180)
# Description

Adds a **Generators companion-specification sample** alongside the
existing pump sample, and a **`SiteCompositionServer`** that composes
several device servers into one OpenUSD scene at a supervisory level —
demonstrating that servers can be aggregated without mirroring their
address spaces.

Three things, in dependency order:

### 1. `GeneratorServer`

A self-contained server realising the draft Generators spec
(`http://opcfoundation.org/UA/Generators/`) end to end: N simulated
generating sets, DI + Machinery integration, a twelve-state operating
state machine, four protection alarms per set, six control methods, and
a per-set OpenUSD twin.

The organising idea is that **load fraction is the only independent
variable**. Everything else is a function of it:

```
V̇_f(x) = 3.67 + 100·x                fuel rate      [L/h]
η(x)   = P(x) / (V̇_f(x) · ρ · LHV)   efficiency
S = P / PF     I = S / (√3·V_LL)     f = N·p / 120
```

This is not stylistic. When each measurement is an independent
oscillator — as the pump sample's simulation once was — a server happily
publishes a duty point no real machine could occupy, and no test can
catch it because there is nothing for the values to be inconsistent
*with*. Deriving them from one variable means `P = √3·V·I·PF` and `η =
P/(V̇·ρ·LHV)` hold at every tick by construction. The published
`DATASHEET.md`, the engineering ranges, the trip points and the
simulation all read the same constants in `GeneratorDatasheet.cs`, so
the document and the server cannot describe different machines.

The machine is a fictitious **SimGen Systems GenX-500** (400 kW prime /
440 kW standby, 400/230 V, 50 Hz, four-pole). Figures are representative
of a real industrial genset class; no vendor is named anywhere in the
code or docs.

### 2. Cross-server composition in the connector

`RemoteSessionFactory` already existed in the client library but the
connector CLI never set it, so cross-server composition was unreachable.
`--federate` wires it up: the connector opens a session to each server
named by a component binding, discovers its representations and drives
its bindings into the same stage.

It is **opt-in** because the endpoint the connector dials comes from the
server being rendered rather than from the operator, which makes
honouring it a trust decision. Federation is best-effort per component —
a subordinate that is down is logged and skipped, and the rest of the
scene still renders — which is the only `src/` change in this PR.

### 3. `SiteCompositionServer`

Owns no devices. It publishes a site stage plus one cross-server
component binding per subordinate, carrying that server's
`ComponentServerUri` and `ComponentEndpointUrl`. Nothing is mirrored, so
there is no cache to invalidate and no second copy of the truth.

## Notes for reviewers

**Everything interesting in this PR was found by running the servers,
not by reading the code.** Six defects, none of which looked wrong in
review:

- `IsShutdown` and `SubsystemName` are *optional* on
`GeneratorProtectionAlarmType`, so the generated factory does not
materialise them. `CreateOrReplace` alone produces a child that exists,
appears in `GetChildren` and holds the right value — but carries **no
`ReferenceTypeId`**, so no browse can reach it. Every alarm was
publishing its trip without saying whether the trip stops the machine or
which subsystem to go to. `AddXxx(context)` first is what gives the
child its `HasProperty` reference.
- **The protections could never fire.** Every trip point sits outside
the band the datasheet curves produce — that is what a datasheet *means*
— so all four alarms, the shutdown class, `ResetFaults` and the whole
`Fault` branch of the state machine were unreachable while the README
documented them as observable. Overload was worse: the load clamp
ceiling was set to exactly the trip point, making a
strictly-greater-than comparison unsatisfiable. Faults are now
injectable, and the first set — the one the hero camera frames —
develops one on a slow rotation.
- **A shutdown trip removes the condition that caused it**, because oil
pressure and coolant temperature are only supervised while the engine
turns. Each alarm went active for one tick and cleared, leaving an
operator with a stopped machine and no indication of why. Shutdown-class
alarms now latch until the set leaves the shutdown state. Every unit
test that checked the *condition* passed throughout — the defect only
appears when the trip and the supervision interact over time.
- **`Synchronizing` and `Paralleled` were declared, drawn in the README
and never entered.** The first set now energises a dead bus and closes
onto it while every other set synchronises to a live one — both how a
real plant parallels, and what makes the two states observable.
- **The tick raced client method calls.** The simulation tick runs on a
thread-pool thread while method calls arrive on request threads, and
both transition sets and write the same nodes. A tick moving a set to
`Cooldown` and a concurrent `EmergencyStop` could interleave the paired
`CurrentState` / `CurrentState.Id` writes and leave a client with a
state *name* from one transition and a state *node* from the other — the
exact failure the paired write exists to prevent, reintroduced by the
threading model. Both paths now take one gate.
- Low oil pressure supervised from raw speed **tripped every set during
cranking**, because pressure has not built yet. Now gated on
`IsSpinning`, which is what a real start-up bypass does.

Smaller fixes: shutdown trips are applied after the whole evaluation
pass (stopping mid-loop made the remaining conditions read healthy,
collapsing simultaneous trips to whichever came first in the table);
`ResetFaults` reports its clears as events (a client learns of condition
state changes only through events, so a silent clear leaves an
alarm-list client showing it forever); the start counter moved into the
transition so commanded starts are counted; the federated connector
closes the remote session if the connector constructor throws between
taking ownership and registering it; and `prepare_machinery_nodeset.py`
now *asserts* the IA namespace is last before removing it rather than
only claiming so in its docstring — removing any earlier entry would
silently renumber every namespace after it and rebind their NodeIds.

**A model limitation is left visible rather than papered over.**
`GeneratorStateMachineType` declares an emergency stop only out of
`Running`, `Loaded` and `Paralleled`, so the sample refuses
`EmergencyStop` from `Starting` and `Warmup`. A real panel stops from
anywhere. That is the specification's shape, not this sample's choice,
so it is pinned by a test and named in the docs.

**`Model/` vendors a reduced Machinery nodeset**, derived mechanically
by whitelist. The full official nodeset does not survive the model
source generator (`MODELGEN003`) and drags in IA through a single
optional `Stacklight` member a generating set does not have. Deriving it
by script keeps the provenance checkable; the whitelist is the only
thing to edit when more types are needed. **Never hand-edit the
generated output.**

**The federated scene renders end to end.** Getting there surfaced three
more defects, all of which produced a plausible-looking scene with
nothing in it: the generator sample's plant aggregation was created
under an already-registered `DeviceSet` and so was invisible to every
client (it had *never* rendered geometry, standalone or federated); the
connector's asset fetch ran on the primary session only, so composition
referenced layers that were never downloaded; and both generator colour
bindings wrote `primvars:displayColor` to prims that did not declare it,
so the renderer rejected every update while the file still looked
correct. Cross-server components compose under the subordinate's own
root, so the site layer now *places* `/Plant` and `/Powerhouse` rather
than leaving them stacked on the origin.

**`OpenUsdRepresentation` is now mounted with `HasAddIn`, not
`HasComponent`** (review feedback). The nodeset says so explicitly —
*"Mounted with HasAddIn"* — but every server in the tree used plain
`HasComponent`. It survived because `HasAddIn` is a *subtype* of
`HasComponent`: the representation still browses, still aggregates and
still drives a twin, so every functional test passed before the fix and
after it, and only a conformance checker could tell. Seven mount sites
corrected. `PumpDeviceIntegrationServer` and `MinimalRobotServer` had
hand-rolled the mount instead of calling the shared
`CreateRepresentation` helper, which is exactly how they drifted from
it. Both sample E2E suites now assert the reference type across
**every** discovered representation — a narrower check would have missed
the plant-level representation that arrived later from master still
carrying `HasComponent`.

**Live colour is not achievable in the current OpenUSD viewer, and that
is now documented rather than worked around.** Proven with a standalone
probe: `primvars:displayColor` resolves as `color3f[]` from the
`UsdGeomGprim` schema whatever the layer declares, and the `OpenUsd
0.4.0-alpha` managed API has no writer for that type. Bound
`UsdPreviewSurface` materials are not shaded either, so geometry renders
grey unless it also carries an explicit `displayColor` primvar. The
**visibility** bindings carry no such caveat and are what the samples
rely on to show state. Filed upstream as
[openusd-dotnet#2](https://github.com/marcschier/openusd-dotnet/issues/2),
[#3](https://github.com/marcschier/openusd-dotnet/issues/3) and
[#4](https://github.com/marcschier/openusd-dotnet/issues/4), and linked
from `docs/OpenUsd.md` so a reader can check whether they have since
been fixed.

## Related Issues

No tracking issue — this is additive sample and documentation work with
a single small, self-contained change to `src/` (per-component error
isolation and session-ownership hardening in
`OpenUsdConnector.Composition.cs`). Happy to open one if maintainers
would prefer it tracked.

## Checklist

- [x] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [x] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

### Testing

The generator fixtures live in `tests/Opc.Ua.OpenUsd.Tests/Generator` —
**82 tests**, no new project. `Opc.Ua.Di.Tests` would have been the
natural home next to the pump fixtures, but both device samples
source-generate their own reduced `Opc.Ua.Machinery` model and expose it
via `InternalsVisibleTo`, so referencing both from one assembly makes
every Machinery type ambiguous (CS0433); `Opc.Ua.OpenUsd.Tests`
references no other sample and already hosts `RobotAssetContractTests`.
The suite runs **870** on net10.0 and net48 (784 existing + 86) and
**788** on net472, where the sample does not exist and only the
framework-independent asset-contract tests run — forgetting exactly that
exclusion broke CI on the sibling pump PR.

The tests target the things in this sample that fail *quietly*:

- **Datasheet conformance** holds the model to its own claim — rated
speed is `120·f/p`, rated current follows from the rating, the fuel
curve reproduces the published table, and `η = P/(V̇·ρ·LHV)` reconciles
at every load. Efficiency is swept across the whole simulated range to
show it stays inside (0,100) and rises monotonically; a fit that goes
negative somewhere in its range is a coincidence that happens to look
right at the duty point, not a model. A further test reads
`DATASHEET.md` and checks the document quotes the figures the server
actually serves.
- **Drift between the two descriptions of the state machine** — the
physics' `IsLegalTransition` and the model's `GeneratorStateMap` — is
checked in *both* directions. A transition the physics permits but the
map lacks moves a machine without telling a client; one the map holds
but the physics refuses is dead weight that looks supported.
- **Reachability at run time**, not just in the declared table — the
test that catches states the model declares and nothing ever enters.
- **That every protection can actually fire**, which is the half of the
alarm contract that "a healthy set annunciates nothing" does not cover.

A **hosted end-to-end fixture** connects a real client and asserts what
the address space actually exposes — the aggregation at
`/Powerhouse/Generators`, its component binding, and every per-set twin.
That is the only kind of test that catches the registration defect
above: the node object had the right browse name, binding and asset
reference, so every test that inspected objects passed while no client
could see it.

**Every state-machine and protection fix was checked by mutation.**
Restoring the clamp ceiling, the direct `Running → Loaded` path, the old
start-counter placement, or removing the alarm opt-in each makes the
corresponding test fail, naming the specific defect. A test that has
never been seen to fail has not been shown to work.

Verified against a running plant: `Synchronizing`, `Paralleled` and
`Fault` all observed on a two-set server, with
`HighCoolantTemperatureAlarm` seen active on the fault subject. Method
behaviour verified separately — per-set distinct `CurrentState` nodes,
`EmergencyStop` → `EmergencyStopped` with `Start` then refused as
`BadInvalidState`, `ResetFaults` → `Off`, `SetOperatingMode(9999)`
refused with the mode unchanged, and the other sets untouched
throughout. Also verified as a three-server federated stage.

0 warnings on a clean Release rebuild of both samples, the client
library, the connector and the tests, across every TFM.

---------

Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Copilot-Session: fe608993-f3c9-4779-a6b9-9a9eabfc24ba
2026-08-07 10:48:02 +02:00

606 lines
26 KiB
C#

/* ========================================================================
* Copyright (c) 2005-2025 The OPC Foundation, Inc. All rights reserved.
*
* OPC Foundation MIT License 1.00
*
* Permission is hereby granted, free of charge, to any person
* obtaining a copy of this software and associated documentation
* files (the "Software"), to deal in the Software without
* restriction, including without limitation the rights to use,
* copy, modify, merge, publish, distribute, sublicense, and/or sell
* copies of the Software, and to permit persons to whom the
* Software is furnished to do so, subject to the following
* conditions:
*
* The above copyright notice and this permission notice shall be
* included in all copies or substantial portions of the Software.
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
* OTHER DEALINGS IN THE SOFTWARE.
*
* The complete license agreement can be found here:
* http://opcfoundation.org/License/MIT/1.00/
* ======================================================================*/
using System;
using System.Collections.Generic;
using System.Globalization;
using System.Threading;
using System.Threading.Tasks;
using Microsoft.Extensions.Logging;
using Microsoft.Extensions.Options;
using Opc.Ua;
using Opc.Ua.Di;
using Opc.Ua.Di.Server;
using Opc.Ua.Di.Server.Builders;
using Opc.Ua.Di.Server.Hosting;
using Opc.Ua.Generators;
using Opc.Ua.Machinery;
using Opc.Ua.OpenUsd;
using Opc.Ua.Server;
using Opc.Ua.Server.Fluent;
using Opc.Ua.Server.NodeManager;
namespace Generators
{
/// <summary>
/// Runtime options for the generator-set device-integration sample.
/// </summary>
public sealed class GeneratorDeviceIntegrationOptions
{
/// <summary>
/// Gets or sets how many simulated generator sets are materialised.
/// </summary>
public int GeneratorCount { get; set; } = 2;
/// <summary>
/// Gets or sets the interval used by the live simulation loop.
/// </summary>
public TimeSpan SimulationInterval { get; set; } = TimeSpan.FromMilliseconds(250);
/// <summary>
/// Gets or sets whether one set develops faults on a slow rotation.
/// </summary>
/// <remarks>
/// On by default. A set running to its datasheet stays well inside every
/// trip point, so without a deliberate excursion the protection alarms, the
/// shutdown class and the Fault branch of the state machine are all code
/// that never runs. Turn it off to watch a plant that is purely healthy.
/// </remarks>
public bool InjectFaults { get; set; } = true;
}
/// <summary>
/// Node manager for the Generators companion-specification server.
/// </summary>
/// <remarks>
/// <para>
/// This partial carries the infrastructure - construction, address-space load
/// and instance materialisation. The datasheet-driven simulation, the twelve
/// state operating state machine and the protection alarms live in
/// <c>GeneratorNodeManager.Configure.cs</c>; the OpenUSD twin lives in
/// <c>OpenUsdRepresentation.cs</c>.
/// </para>
/// <para>
/// Unlike the pump sample - whose <c>PumpType</c> derives from the Machinery
/// <c>MachineType</c> and so cannot use the DI device helpers -
/// <c>GeneratorSetType</c> derives from the DI <c>DeviceType</c>, so sets are
/// created through <see cref="DiNodeManager.CreateDeviceAsync{TDevice}"/> and
/// get the DI nameplate, registration and topology wiring for free.
/// </para>
/// </remarks>
public partial class GeneratorNodeManager : DiNodeManager
{
private readonly GeneratorDeviceIntegrationOptions m_options;
private readonly List<GeneratorSetState> m_generatorSets = [];
/// <summary>
/// Wires the simulation, state machines and alarms against the
/// materialised instances. Implemented in
/// <c>GeneratorNodeManager.Configure.cs</c>.
/// </summary>
/// <param name="builder">The active fluent builder.</param>
partial void Configure(INodeManagerBuilder builder);
/// <summary>
/// Initialises a new <see cref="GeneratorNodeManager"/> without DI-hosting
/// integration.
/// </summary>
/// <param name="server">The server the manager belongs to.</param>
/// <param name="configuration">The application configuration.</param>
public GeneratorNodeManager(
IServerInternal server,
ApplicationConfiguration configuration)
: this(server, configuration, postSetupRunner: null, options: null)
{
}
/// <summary>
/// Initialises a new <see cref="GeneratorNodeManager"/> that participates in
/// the DI hosting post-setup pipeline.
/// </summary>
/// <param name="server">The server the manager belongs to.</param>
/// <param name="configuration">The application configuration.</param>
/// <param name="postSetupRunner">Optional DI post-setup pipeline.</param>
/// <param name="options">Optional sample options.</param>
/// <exception cref="ArgumentOutOfRangeException">
/// The configured generator count or simulation interval is out of range.
/// </exception>
public GeneratorNodeManager(
IServerInternal server,
ApplicationConfiguration configuration,
IDiPostSetupRunner? postSetupRunner,
IOptions<GeneratorDeviceIntegrationOptions>? options = null)
: base(
server,
configuration,
postSetupRunner,
Opc.Ua.Generators.Namespaces.Generators,
Opc.Ua.Machinery.Namespaces.Machinery,
Opc.Ua.OpenUsd.Namespaces.OpenUSD)
{
// The base constructor points SystemContext.NodeIdFactory at itself;
// the New() override below takes over so every instance child gets a
// NodeId derived from its parent rather than the type-level one.
SystemContext.NodeIdFactory = this;
m_options = options?.Value ?? new GeneratorDeviceIntegrationOptions();
if (m_options.GeneratorCount is < 1 or > 100)
{
throw new ArgumentOutOfRangeException(
$"{nameof(options)}.{nameof(GeneratorDeviceIntegrationOptions.GeneratorCount)}",
m_options.GeneratorCount,
"Generator count must be between 1 and 100.");
}
if (m_options.SimulationInterval <= TimeSpan.Zero)
{
throw new ArgumentOutOfRangeException(
$"{nameof(options)}.{nameof(GeneratorDeviceIntegrationOptions.SimulationInterval)}",
m_options.SimulationInterval,
"Simulation interval must be positive.");
}
}
/// <summary>
/// Gets the registered generator-set instance NodeIds.
/// </summary>
public ArrayOf<NodeId> GeneratorNodeIds
{
get
{
var nodeIds = new List<NodeId>(m_generatorSets.Count);
foreach (GeneratorSetState set in m_generatorSets)
{
nodeIds.Add(set.NodeId);
}
return nodeIds.ToArrayOf();
}
}
/// <summary>
/// Gets the interval the simulation loop ticks at.
/// </summary>
internal TimeSpan SimulationInterval => m_options.SimulationInterval;
/// <summary>
/// Gets whether the fault schedule is running.
/// </summary>
internal bool InjectFaults => m_options.InjectFaults;
/// <inheritdoc/>
public override NodeId New(ISystemContext context, NodeState node)
{
if (node is BaseInstanceState { Parent: not null } instance)
{
string parentId = instance.Parent.NodeId.IdentifierAsString;
return new NodeId(
$"{parentId}_{instance.SymbolicName}",
InstanceNamespaceIndex);
}
return node.NodeId;
}
/// <summary>
/// Creates and registers a generator set organised by the DI
/// <c>DeviceSet</c>, wired into the running simulation.
/// </summary>
/// <param name="browseName">Browse name for the new set.</param>
/// <param name="cancellationToken">Cancellation token.</param>
/// <returns>The registered generator set.</returns>
public ValueTask<GeneratorSetState> CreateGeneratorSetAsync(
QualifiedName browseName,
CancellationToken cancellationToken = default)
{
return MaterialiseGeneratorSetAsync(
browseName,
m_generatorSets.Count + 1,
cancellationToken,
RegisterGeneratorSimulation);
}
/// <inheritdoc/>
protected override ValueTask<NodeStateCollection> LoadPredefinedNodesAsync(
ISystemContext context,
CancellationToken cancellationToken = default)
{
// Compose the predefined-node tree from the source-generated models in
// dependency order. No runtime XML loading: the NodeSet2 XMLs ship only
// as <AdditionalFiles> for the source generator. The generated AddOpcUa*
// methods are idempotent and pull in their declared dependencies through
// [ModelDependencyAttribute], so a direct chain is sufficient.
var nodes = new NodeStateCollection();
nodes.AddOpcUaDi(context);
nodes.AddOpcUaMachinery(context);
nodes.AddOpcUaGenerators(context);
nodes.AddOpcUaOpenUsd(context);
return new ValueTask<NodeStateCollection>(nodes);
}
/// <inheritdoc/>
protected override async ValueTask OnAddressSpaceReadyAsync(
CancellationToken cancellationToken)
{
// Phase 1 (async): materialise the instances the fluent Configure pass
// expects to find, so the builder has typed nodes to wire against.
await ConfigureInstancesAsync(cancellationToken).ConfigureAwait(false);
// Phase 2 (sync): wire the simulation, state machines and alarms.
CreateFluentBuilder(InstanceNamespaceIndex)
.Configure(Configure)
.Seal();
m_logger.GeneratorAddressSpaceReady(PredefinedNodes.Count, m_generatorSets.Count);
}
/// <summary>
/// Materialises the configured generator sets and the OpenUSD facility.
/// </summary>
/// <param name="cancellationToken">Cancellation token.</param>
private async ValueTask ConfigureInstancesAsync(CancellationToken cancellationToken)
{
// The OpenUSD facility comes first so each set's representation has a
// stage to reference.
await MaterialiseOpenUsdFacilityAsync(cancellationToken).ConfigureAwait(false);
for (int number = 1; number <= m_options.GeneratorCount; number++)
{
var browseName = new QualifiedName(
GetGeneratorBrowseName(number),
InstanceNamespaceIndex);
await MaterialiseGeneratorSetAsync(browseName, number, cancellationToken)
.ConfigureAwait(false);
}
await OrganiseRepresentationsAsync(cancellationToken).ConfigureAwait(false);
}
/// <summary>
/// Creates one generator set, materialises the optional subsystems the
/// simulation drives, attaches its OpenUSD twin and registers the whole
/// subtree.
/// </summary>
/// <param name="browseName">Browse name for the set.</param>
/// <param name="setNumber">One-based unit number, used for the nameplate.</param>
/// <param name="cancellationToken">Cancellation token.</param>
/// <param name="onRegistered">Invoked once the set is registered.</param>
/// <returns>The registered generator set.</returns>
private async ValueTask<GeneratorSetState> MaterialiseGeneratorSetAsync(
QualifiedName browseName,
int setNumber,
CancellationToken cancellationToken,
Action<GeneratorSetState>? onRegistered = null)
{
IDeviceBuilder<GeneratorSetState> builder = await CreateDeviceAsync(
browseName,
NodeId.Create(
Opc.Ua.Generators.ObjectTypes.GeneratorSetType,
Opc.Ua.Generators.Namespaces.Generators,
Server.NamespaceUris),
parent => SystemContext.CreateInstanceOfGeneratorSetType(parent, browseName),
parent: null,
cancellationToken).ConfigureAwait(false);
GeneratorSetState set = builder.Device;
set.DisplayName = new LocalizedText(GetGeneratorDisplayName(setNumber));
MaterialiseOptionalChildren(set);
MaterialiseProtectionAlarms(set);
AttachOpenUsdRepresentation(set, setNumber);
await AddPredefinedNodeAsync(SystemContext, set, cancellationToken)
.ConfigureAwait(false);
await AddRootNotifierAsync(set, cancellationToken).ConfigureAwait(false);
// The nameplate is written after the subtree is registered. Each
// identification property registers itself as it is created, so writing
// beforehand lets the subsequent subtree registration replace those
// nodes with freshly materialised, valueless ones - the properties then
// browse but read BadNotReadable.
WriteNameplate(builder, setNumber);
onRegistered?.Invoke(set);
// Variables hand-built onto the set (rather than materialised by the
// generated factory) browse and read correctly, but a monitored item
// never samples them unless they are registered in their own right.
await RegisterOpenUsdSignalsAsync(set, cancellationToken).ConfigureAwait(false);
m_generatorSets.Add(set);
m_logger.MaterialisedGeneratorSet(browseName.Name, set.NodeId);
return set;
}
/// <summary>
/// Writes the datasheet nameplate onto the DI identification properties.
/// </summary>
/// <param name="builder">Device builder for the set.</param>
/// <param name="setNumber">One-based unit number.</param>
/// <remarks>
/// Unit-level fields are derived from the set number so that
/// <c>--generators N</c> yields a consistent nameplate per instance rather
/// than N copies of the same serial number.
/// </remarks>
private static void WriteNameplate(IDeviceBuilder<GeneratorSetState> builder, int setNumber)
{
builder.WithIdentification(id =>
{
id.Manufacturer = new LocalizedText(GeneratorDatasheet.Identity.Manufacturer);
id.ManufacturerUri = GeneratorDatasheet.Identity.ManufacturerUri;
id.Model = new LocalizedText(GeneratorDatasheet.Identity.Model);
id.ProductCode = GeneratorDatasheet.Identity.ProductCode;
id.HardwareRevision = GeneratorDatasheet.Identity.HardwareRevision;
id.SoftwareRevision = GeneratorDatasheet.Identity.SoftwareRevision;
id.DeviceRevision = GeneratorDatasheet.Identity.DeviceRevision;
id.SerialNumber = GetSerialNumber(setNumber);
id.DeviceManual = "https://simgen.example.com/genx-500/manual";
id.ProductInstanceUri = FormattableString.Invariant($"urn:simgen.example.com:GenX-500:{GetSerialNumber(setNumber)}");
});
// Nameplate properties the generated factory already materialised keep
// the declaration's access level, which grants no read. Only properties
// the builder creates itself come out readable, so the ones that were
// already there have to be opened explicitly or they browse but answer
// BadNotReadable.
GeneratorSetState set = builder.Device;
MakeReadable(
set.Manufacturer, set.ManufacturerUri, set.Model, set.ProductCode,
set.HardwareRevision, set.SoftwareRevision, set.DeviceRevision,
set.SerialNumber, set.DeviceManual, set.ProductInstanceUri,
set.RevisionCounter);
}
/// <summary>
/// Grants current-read access to variables that carry a static value.
/// </summary>
/// <param name="variables">The variables to open for reading.</param>
private static void MakeReadable(params BaseVariableState?[] variables)
{
foreach (BaseVariableState? variable in variables)
{
if (variable == null)
{
continue;
}
variable.AccessLevel = AccessLevels.CurrentRead;
variable.UserAccessLevel = AccessLevels.CurrentRead;
variable.MinimumSamplingInterval = MinimumSamplingIntervals.Indeterminate;
}
}
/// <summary>
/// Materialises the optional <c>GeneratorSetType</c> children the simulation
/// drives. Mandatory children - Identification, OperatingState, OperatingMode,
/// Engine, Alternator and Controller - are created by the generated factory.
/// </summary>
/// <param name="set">The generator set to extend.</param>
private void MaterialiseOptionalChildren(GeneratorSetState set)
{
set.AddMachineryBuildingBlocks(SystemContext)
.AddFuelSystem(SystemContext)
.AddCoolingSystem(SystemContext)
.AddLubricationSystem(SystemContext)
.AddStartingSystem(SystemContext)
.AddEmissionsStandard(SystemContext)
.AddApplication(SystemContext)
.AddGeneratorBreakerClosed(SystemContext)
.AddGeneratorBreakerAvailable(SystemContext)
.AddRemoteStartInput(SystemContext)
.AddRunRequest(SystemContext)
.AddLoadInhibit(SystemContext)
.AddAvailableToLoad(SystemContext)
.AddStart(SystemContext)
.AddStop(SystemContext)
.AddEmergencyStop(SystemContext)
.AddResetFaults(SystemContext)
.AddSetOperatingMode(SystemContext)
.AddStartTest(SystemContext);
MaterialiseSubsystemChildren(set);
}
/// <summary>
/// Materialises the optional subsystem members the simulation publishes.
/// </summary>
/// <param name="set">The generator set to extend.</param>
/// <remarks>
/// The specification makes most telemetry optional so the type fits both a
/// bare air-cooled residential set and a fully instrumented industrial one.
/// This sample models the instrumented case, so it opts in explicitly rather
/// than assuming the factory materialises them.
/// </remarks>
private void MaterialiseSubsystemChildren(GeneratorSetState set)
{
set.Engine!
.AddPercentLoad(SystemContext)
.AddOilPressure(SystemContext)
.AddOilTemperature(SystemContext)
.AddCoolantTemperature(SystemContext)
.AddFuelRate(SystemContext)
.AddExhaustGasTemperature(SystemContext)
.AddIntakeManifoldTemperature(SystemContext)
.AddNumberOfStarts(SystemContext)
.AddDisplacement(SystemContext)
.AddCylinderCount(SystemContext)
.AddRatedSpeed(SystemContext)
.AddAspiration(SystemContext);
// Three-phase set: L1 is mandatory, L2 and L3 are not.
set.Alternator!
.AddL2(SystemContext)
.AddL3(SystemContext)
.AddAverageLineToLineVoltage(SystemContext)
.AddAverageLineToNeutralVoltage(SystemContext)
.AddAverageCurrent(SystemContext)
.AddTotalReactivePower(SystemContext)
.AddTotalApparentPower(SystemContext)
.AddAveragePowerFactor(SystemContext)
.AddTotalRealEnergy(SystemContext)
.AddLoadPercent(SystemContext)
.AddWindingTemperature1(SystemContext)
.AddConnection(SystemContext)
.AddExcitationType(SystemContext)
.AddNumberOfPoles(SystemContext);
foreach (AlternatorPhaseState phase in new[]
{
set.Alternator!.L1!, set.Alternator!.L2!, set.Alternator!.L3!,
})
{
phase.AddLineToNeutralVoltage(SystemContext)
.AddLineToLineVoltage(SystemContext)
.AddRealPower(SystemContext)
.AddReactivePower(SystemContext)
.AddApparentPower(SystemContext)
.AddPowerFactor(SystemContext);
}
set.FuelSystem!
.AddFuelLevel(SystemContext)
.AddFuelVolume(SystemContext)
.AddFuelConsumptionRate(SystemContext)
.AddRuntimeRemaining(SystemContext)
.AddTotalFuelConsumed(SystemContext);
set.CoolingSystem!
.AddCoolantTemperature(SystemContext)
.AddCoolantLevel(SystemContext)
.AddAmbientTemperature(SystemContext)
.AddCoolingMethod(SystemContext)
.AddRadiatorFanRunning(SystemContext);
set.LubricationSystem!
.AddOilPressure(SystemContext)
.AddOilTemperature(SystemContext)
.AddOilLevel(SystemContext);
set.StartingSystem!
.AddBatteryChargingCurrent(SystemContext)
.AddBatteryChargerActive(SystemContext)
.AddStartAttempts(SystemContext);
}
/// <summary>
/// Returns the browse name for a one-based generator set number.
/// </summary>
/// <param name="setNumber">One-based unit number.</param>
/// <returns>The browse name.</returns>
internal static string GetGeneratorBrowseName(int setNumber)
{
return FormattableString.Invariant($"GeneratorSet_{setNumber}");
}
/// <summary>
/// Returns the display name for a one-based generator set number.
/// </summary>
/// <param name="setNumber">One-based unit number.</param>
/// <returns>The display name.</returns>
internal static string GetGeneratorDisplayName(int setNumber)
{
return FormattableString.Invariant($"Generator Set {setNumber}");
}
/// <summary>
/// Returns the datasheet serial number for a one-based generator set number.
/// </summary>
/// <param name="setNumber">One-based unit number.</param>
/// <returns>The serial number.</returns>
internal static string GetSerialNumber(int setNumber)
{
return FormattableString.Invariant($"SG-500-{setNumber:D3}");
}
}
/// <summary>
/// Creates the <see cref="GeneratorNodeManager"/> for the DI hosting pipeline.
/// </summary>
public sealed class GeneratorNodeManagerFactory : IAsyncNodeManagerFactory
{
private readonly IDiPostSetupRunner? m_postSetupRunner;
private readonly IOptions<GeneratorDeviceIntegrationOptions>? m_options;
/// <summary>
/// Initialises a factory without DI-hosting integration.
/// </summary>
public GeneratorNodeManagerFactory()
{
}
/// <summary>
/// Initialises a factory that participates in the DI hosting pipeline.
/// </summary>
/// <param name="postSetupRunner">The DI post-setup pipeline.</param>
/// <param name="options">Sample options.</param>
public GeneratorNodeManagerFactory(
IDiPostSetupRunner? postSetupRunner,
IOptions<GeneratorDeviceIntegrationOptions>? options)
{
m_postSetupRunner = postSetupRunner;
m_options = options;
}
/// <inheritdoc/>
public ArrayOf<string> NamespacesUris => new string[]
{
Opc.Ua.Generators.Namespaces.Generators,
Opc.Ua.Machinery.Namespaces.Machinery,
Opc.Ua.OpenUsd.Namespaces.OpenUSD,
}.ToArrayOf();
/// <inheritdoc/>
public ValueTask<IAsyncNodeManager> CreateAsync(
IServerInternal server,
ApplicationConfiguration configuration,
CancellationToken cancellationToken = default)
{
#pragma warning disable CA2000 // ownership transferred to server
IAsyncNodeManager nodeManager =
new GeneratorNodeManager(server, configuration, m_postSetupRunner, m_options);
#pragma warning restore CA2000
return new ValueTask<IAsyncNodeManager>(nodeManager);
}
}
/// <summary>
/// Source-generated log messages for <see cref="GeneratorNodeManager"/>.
/// </summary>
internal static partial class GeneratorNodeManagerLog {
[LoggerMessage(
EventId = GeneratorServerEventIds.GeneratorNodeManager + 0,
Level = LogLevel.Information,
Message = "Generator address space ready: {NodeCount} nodes, {SetCount} generator set(s).")]
public static partial void GeneratorAddressSpaceReady(
this ILogger logger, int nodeCount, int setCount);
[LoggerMessage(
EventId = GeneratorServerEventIds.GeneratorNodeManager + 1,
Level = LogLevel.Information,
Message = "Materialised generator set '{BrowseName}' as {NodeId}.")]
public static partial void MaterialisedGeneratorSet(
this ILogger logger, string? browseName, NodeId nodeId);
}
}