# Description Adds a **Generators companion-specification sample** alongside the existing pump sample, and a **`SiteCompositionServer`** that composes several device servers into one OpenUSD scene at a supervisory level — demonstrating that servers can be aggregated without mirroring their address spaces. Three things, in dependency order: ### 1. `GeneratorServer` A self-contained server realising the draft Generators spec (`http://opcfoundation.org/UA/Generators/`) end to end: N simulated generating sets, DI + Machinery integration, a twelve-state operating state machine, four protection alarms per set, six control methods, and a per-set OpenUSD twin. The organising idea is that **load fraction is the only independent variable**. Everything else is a function of it: ``` V̇_f(x) = 3.67 + 100·x fuel rate [L/h] η(x) = P(x) / (V̇_f(x) · ρ · LHV) efficiency S = P / PF I = S / (√3·V_LL) f = N·p / 120 ``` This is not stylistic. When each measurement is an independent oscillator — as the pump sample's simulation once was — a server happily publishes a duty point no real machine could occupy, and no test can catch it because there is nothing for the values to be inconsistent *with*. Deriving them from one variable means `P = √3·V·I·PF` and `η = P/(V̇·ρ·LHV)` hold at every tick by construction. The published `DATASHEET.md`, the engineering ranges, the trip points and the simulation all read the same constants in `GeneratorDatasheet.cs`, so the document and the server cannot describe different machines. The machine is a fictitious **SimGen Systems GenX-500** (400 kW prime / 440 kW standby, 400/230 V, 50 Hz, four-pole). Figures are representative of a real industrial genset class; no vendor is named anywhere in the code or docs. ### 2. Cross-server composition in the connector `RemoteSessionFactory` already existed in the client library but the connector CLI never set it, so cross-server composition was unreachable. `--federate` wires it up: the connector opens a session to each server named by a component binding, discovers its representations and drives its bindings into the same stage. It is **opt-in** because the endpoint the connector dials comes from the server being rendered rather than from the operator, which makes honouring it a trust decision. Federation is best-effort per component — a subordinate that is down is logged and skipped, and the rest of the scene still renders — which is the only `src/` change in this PR. ### 3. `SiteCompositionServer` Owns no devices. It publishes a site stage plus one cross-server component binding per subordinate, carrying that server's `ComponentServerUri` and `ComponentEndpointUrl`. Nothing is mirrored, so there is no cache to invalidate and no second copy of the truth. ## Notes for reviewers **Everything interesting in this PR was found by running the servers, not by reading the code.** Six defects, none of which looked wrong in review: - `IsShutdown` and `SubsystemName` are *optional* on `GeneratorProtectionAlarmType`, so the generated factory does not materialise them. `CreateOrReplace` alone produces a child that exists, appears in `GetChildren` and holds the right value — but carries **no `ReferenceTypeId`**, so no browse can reach it. Every alarm was publishing its trip without saying whether the trip stops the machine or which subsystem to go to. `AddXxx(context)` first is what gives the child its `HasProperty` reference. - **The protections could never fire.** Every trip point sits outside the band the datasheet curves produce — that is what a datasheet *means* — so all four alarms, the shutdown class, `ResetFaults` and the whole `Fault` branch of the state machine were unreachable while the README documented them as observable. Overload was worse: the load clamp ceiling was set to exactly the trip point, making a strictly-greater-than comparison unsatisfiable. Faults are now injectable, and the first set — the one the hero camera frames — develops one on a slow rotation. - **A shutdown trip removes the condition that caused it**, because oil pressure and coolant temperature are only supervised while the engine turns. Each alarm went active for one tick and cleared, leaving an operator with a stopped machine and no indication of why. Shutdown-class alarms now latch until the set leaves the shutdown state. Every unit test that checked the *condition* passed throughout — the defect only appears when the trip and the supervision interact over time. - **`Synchronizing` and `Paralleled` were declared, drawn in the README and never entered.** The first set now energises a dead bus and closes onto it while every other set synchronises to a live one — both how a real plant parallels, and what makes the two states observable. - **The tick raced client method calls.** The simulation tick runs on a thread-pool thread while method calls arrive on request threads, and both transition sets and write the same nodes. A tick moving a set to `Cooldown` and a concurrent `EmergencyStop` could interleave the paired `CurrentState` / `CurrentState.Id` writes and leave a client with a state *name* from one transition and a state *node* from the other — the exact failure the paired write exists to prevent, reintroduced by the threading model. Both paths now take one gate. - Low oil pressure supervised from raw speed **tripped every set during cranking**, because pressure has not built yet. Now gated on `IsSpinning`, which is what a real start-up bypass does. Smaller fixes: shutdown trips are applied after the whole evaluation pass (stopping mid-loop made the remaining conditions read healthy, collapsing simultaneous trips to whichever came first in the table); `ResetFaults` reports its clears as events (a client learns of condition state changes only through events, so a silent clear leaves an alarm-list client showing it forever); the start counter moved into the transition so commanded starts are counted; the federated connector closes the remote session if the connector constructor throws between taking ownership and registering it; and `prepare_machinery_nodeset.py` now *asserts* the IA namespace is last before removing it rather than only claiming so in its docstring — removing any earlier entry would silently renumber every namespace after it and rebind their NodeIds. **A model limitation is left visible rather than papered over.** `GeneratorStateMachineType` declares an emergency stop only out of `Running`, `Loaded` and `Paralleled`, so the sample refuses `EmergencyStop` from `Starting` and `Warmup`. A real panel stops from anywhere. That is the specification's shape, not this sample's choice, so it is pinned by a test and named in the docs. **`Model/` vendors a reduced Machinery nodeset**, derived mechanically by whitelist. The full official nodeset does not survive the model source generator (`MODELGEN003`) and drags in IA through a single optional `Stacklight` member a generating set does not have. Deriving it by script keeps the provenance checkable; the whitelist is the only thing to edit when more types are needed. **Never hand-edit the generated output.** **The federated scene renders end to end.** Getting there surfaced three more defects, all of which produced a plausible-looking scene with nothing in it: the generator sample's plant aggregation was created under an already-registered `DeviceSet` and so was invisible to every client (it had *never* rendered geometry, standalone or federated); the connector's asset fetch ran on the primary session only, so composition referenced layers that were never downloaded; and both generator colour bindings wrote `primvars:displayColor` to prims that did not declare it, so the renderer rejected every update while the file still looked correct. Cross-server components compose under the subordinate's own root, so the site layer now *places* `/Plant` and `/Powerhouse` rather than leaving them stacked on the origin. **`OpenUsdRepresentation` is now mounted with `HasAddIn`, not `HasComponent`** (review feedback). The nodeset says so explicitly — *"Mounted with HasAddIn"* — but every server in the tree used plain `HasComponent`. It survived because `HasAddIn` is a *subtype* of `HasComponent`: the representation still browses, still aggregates and still drives a twin, so every functional test passed before the fix and after it, and only a conformance checker could tell. Seven mount sites corrected. `PumpDeviceIntegrationServer` and `MinimalRobotServer` had hand-rolled the mount instead of calling the shared `CreateRepresentation` helper, which is exactly how they drifted from it. Both sample E2E suites now assert the reference type across **every** discovered representation — a narrower check would have missed the plant-level representation that arrived later from master still carrying `HasComponent`. **Live colour is not achievable in the current OpenUSD viewer, and that is now documented rather than worked around.** Proven with a standalone probe: `primvars:displayColor` resolves as `color3f[]` from the `UsdGeomGprim` schema whatever the layer declares, and the `OpenUsd 0.4.0-alpha` managed API has no writer for that type. Bound `UsdPreviewSurface` materials are not shaded either, so geometry renders grey unless it also carries an explicit `displayColor` primvar. The **visibility** bindings carry no such caveat and are what the samples rely on to show state. Filed upstream as [openusd-dotnet#2](https://github.com/marcschier/openusd-dotnet/issues/2), [#3](https://github.com/marcschier/openusd-dotnet/issues/3) and [#4](https://github.com/marcschier/openusd-dotnet/issues/4), and linked from `docs/OpenUsd.md` so a reader can check whether they have since been fixed. ## Related Issues No tracking issue — this is additive sample and documentation work with a single small, self-contained change to `src/` (per-component error isolation and session-ownership hardening in `OpenUsdConnector.Composition.cs`). Happy to open one if maintainers would prefer it tracked. ## Checklist - [x] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [x] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. ### Testing The generator fixtures live in `tests/Opc.Ua.OpenUsd.Tests/Generator` — **82 tests**, no new project. `Opc.Ua.Di.Tests` would have been the natural home next to the pump fixtures, but both device samples source-generate their own reduced `Opc.Ua.Machinery` model and expose it via `InternalsVisibleTo`, so referencing both from one assembly makes every Machinery type ambiguous (CS0433); `Opc.Ua.OpenUsd.Tests` references no other sample and already hosts `RobotAssetContractTests`. The suite runs **870** on net10.0 and net48 (784 existing + 86) and **788** on net472, where the sample does not exist and only the framework-independent asset-contract tests run — forgetting exactly that exclusion broke CI on the sibling pump PR. The tests target the things in this sample that fail *quietly*: - **Datasheet conformance** holds the model to its own claim — rated speed is `120·f/p`, rated current follows from the rating, the fuel curve reproduces the published table, and `η = P/(V̇·ρ·LHV)` reconciles at every load. Efficiency is swept across the whole simulated range to show it stays inside (0,100) and rises monotonically; a fit that goes negative somewhere in its range is a coincidence that happens to look right at the duty point, not a model. A further test reads `DATASHEET.md` and checks the document quotes the figures the server actually serves. - **Drift between the two descriptions of the state machine** — the physics' `IsLegalTransition` and the model's `GeneratorStateMap` — is checked in *both* directions. A transition the physics permits but the map lacks moves a machine without telling a client; one the map holds but the physics refuses is dead weight that looks supported. - **Reachability at run time**, not just in the declared table — the test that catches states the model declares and nothing ever enters. - **That every protection can actually fire**, which is the half of the alarm contract that "a healthy set annunciates nothing" does not cover. A **hosted end-to-end fixture** connects a real client and asserts what the address space actually exposes — the aggregation at `/Powerhouse/Generators`, its component binding, and every per-set twin. That is the only kind of test that catches the registration defect above: the node object had the right browse name, binding and asset reference, so every test that inspected objects passed while no client could see it. **Every state-machine and protection fix was checked by mutation.** Restoring the clamp ceiling, the direct `Running → Loaded` path, the old start-counter placement, or removing the alarm opt-in each makes the corresponding test fail, naming the specific defect. A test that has never been seen to fail has not been shown to work. Verified against a running plant: `Synchronizing`, `Paralleled` and `Fault` all observed on a two-set server, with `HighCoolantTemperatureAlarm` seen active on the fault subject. Method behaviour verified separately — per-set distinct `CurrentState` nodes, `EmergencyStop` → `EmergencyStopped` with `Start` then refused as `BadInvalidState`, `ResetFaults` → `Off`, `SetOperatingMode(9999)` refused with the mode unchanged, and the other sets untouched throughout. Also verified as a three-server federated stage. 0 warnings on a clean Release rebuild of both samples, the client library, the connector and the tests, across every TFM. --------- Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com> Copilot-Session: fe608993-f3c9-4779-a6b9-9a9eabfc24ba
408 lines
18 KiB
C#
408 lines
18 KiB
C#
/* ========================================================================
|
|
* Copyright (c) 2005-2025 The OPC Foundation, Inc. All rights reserved.
|
|
*
|
|
* OPC Foundation MIT License 1.00
|
|
*
|
|
* Permission is hereby granted, free of charge, to any person
|
|
* obtaining a copy of this software and associated documentation
|
|
* files (the "Software"), to deal in the Software without
|
|
* restriction, including without limitation the rights to use,
|
|
* copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
* copies of the Software, and to permit persons to whom the
|
|
* Software is furnished to do so, subject to the following
|
|
* conditions:
|
|
*
|
|
* The above copyright notice and this permission notice shall be
|
|
* included in all copies or substantial portions of the Software.
|
|
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
|
|
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
|
|
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
|
|
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
|
|
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
|
|
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
|
|
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
|
|
* OTHER DEALINGS IN THE SOFTWARE.
|
|
*
|
|
* The complete license agreement can be found here:
|
|
* http://opcfoundation.org/License/MIT/1.00/
|
|
* ======================================================================*/
|
|
|
|
using System;
|
|
using System.Collections.Concurrent;
|
|
using System.Collections.Generic;
|
|
using Opc.Ua;
|
|
using Opc.Ua.Generators;
|
|
|
|
namespace Generators
|
|
{
|
|
/// <summary>
|
|
/// The protection alarms a generating set annunciates.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// One <c>GeneratorProtectionAlarmType</c> instance per protection function
|
|
/// rather than a single instance whose <c>ProtectionFunction</c> changes: a set
|
|
/// can trip on low oil pressure and overspeed at the same moment, and an
|
|
/// operator needs to see both. It is also how a real control panel annunciates.
|
|
/// </para>
|
|
/// <para>
|
|
/// Because <c>OffNormalAlarmType</c> takes <em>healthy</em> as the normal state,
|
|
/// each instance carries the supervised input and its normal value so a client
|
|
/// can find what is actually being watched.
|
|
/// </para>
|
|
/// </remarks>
|
|
public partial class GeneratorNodeManager
|
|
{
|
|
private readonly ConcurrentDictionary<NodeId, List<ProtectionAlarm>> m_alarms = new();
|
|
|
|
/// <summary>
|
|
/// Creates the protection alarm nodes for one set.
|
|
/// </summary>
|
|
/// <param name="set">The generator set.</param>
|
|
/// <remarks>
|
|
/// Called while the set is being materialised, before its subtree is
|
|
/// registered, so the alarms register along with everything else. Building
|
|
/// them later would mean registering each one separately from a synchronous
|
|
/// context, which is how sync-over-async creeps in.
|
|
/// </remarks>
|
|
private void MaterialiseProtectionAlarms(GeneratorSetState set)
|
|
{
|
|
ushort ns = (ushort)Server.NamespaceUris.GetIndex(
|
|
Opc.Ua.Generators.Namespaces.Generators);
|
|
|
|
foreach (ProtectionDefinition definition in GeneratorProtections.Definitions)
|
|
{
|
|
Create(set, ns, definition);
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Binds the trip conditions once the simulation for a set exists.
|
|
/// </summary>
|
|
/// <param name="set">The generator set.</param>
|
|
/// <param name="simulation">The set's simulation.</param>
|
|
private void AttachProtectionAlarms(GeneratorSetState set, GeneratorSimulation simulation)
|
|
{
|
|
var alarms = new List<ProtectionAlarm>();
|
|
foreach (ProtectionDefinition definition in GeneratorProtections.Definitions)
|
|
{
|
|
if (FindPredefinedNode<GeneratorProtectionAlarmState>(
|
|
AlarmNodeId(set, definition.Name)) is not { } alarm)
|
|
{
|
|
continue;
|
|
}
|
|
alarms.Add(new ProtectionAlarm(
|
|
alarm, () => definition.IsTripped(simulation), definition.IsShutdown));
|
|
}
|
|
m_alarms[set.NodeId] = alarms;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Returns the NodeId an alarm is minted with.
|
|
/// </summary>
|
|
/// <param name="set">Owning generator set.</param>
|
|
/// <param name="name">Alarm browse name.</param>
|
|
/// <returns>The alarm's NodeId.</returns>
|
|
private NodeId AlarmNodeId(GeneratorSetState set, string name)
|
|
{
|
|
return new NodeId(
|
|
$"{set.NodeId.IdentifierAsString}_{name}", InstanceNamespaceIndex);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Creates and configures one protection alarm node.
|
|
/// </summary>
|
|
/// <param name="set">Owning generator set.</param>
|
|
/// <param name="ns">Generators namespace index.</param>
|
|
/// <param name="definition">What the alarm reports.</param>
|
|
private void Create(GeneratorSetState set, ushort ns, ProtectionDefinition definition)
|
|
{
|
|
GeneratorProtectionAlarmState alarm = SystemContext
|
|
.CreateInstanceOfGeneratorProtectionAlarmType(
|
|
set, new QualifiedName(definition.Name, ns));
|
|
alarm.ReferenceTypeId = ReferenceTypeIds.HasComponent;
|
|
alarm.SymbolicName = definition.Name;
|
|
|
|
GeneratorProtections.ApplyDefinition(alarm, SystemContext, definition);
|
|
|
|
set.AddChild(alarm);
|
|
|
|
alarm.CreateOrReplaceEventType(SystemContext, null!).Value = NodeId.Create(
|
|
Opc.Ua.Generators.ObjectTypes.GeneratorProtectionAlarmType,
|
|
Opc.Ua.Generators.Namespaces.Generators,
|
|
Server.NamespaceUris);
|
|
alarm.CreateOrReplaceSourceNode(SystemContext, null!).Value = set.NodeId;
|
|
alarm.CreateOrReplaceSourceName(SystemContext, null!).Value =
|
|
set.BrowseName.Name ?? string.Empty;
|
|
alarm.CreateOrReplaceConditionName(SystemContext, null!).Value = definition.Name;
|
|
alarm.CreateOrReplaceSeverity(SystemContext, null!).Value = definition.Severity;
|
|
alarm.CreateOrReplaceRetain(SystemContext, null!).Value = false;
|
|
alarm.CreateOrReplaceTime(SystemContext, null!).Value = DateTime.UtcNow;
|
|
alarm.CreateOrReplaceReceiveTime(SystemContext, null!).Value = DateTime.UtcNow;
|
|
alarm.CreateOrReplaceMessage(SystemContext, null!).Value =
|
|
new LocalizedText("Protection healthy.");
|
|
|
|
// OffNormalAlarmType treats healthy as normal, so record what is being
|
|
// supervised rather than leaving a client to guess.
|
|
NodeId input = definition.Name switch
|
|
{
|
|
"LowOilPressureAlarm" => set.LubricationSystem?.OilPressure?.NodeId ?? NodeId.Null,
|
|
"HighCoolantTemperatureAlarm" => set.Engine?.CoolantTemperature?.NodeId ?? NodeId.Null,
|
|
"OverspeedAlarm" => set.Engine?.Speed?.NodeId ?? NodeId.Null,
|
|
_ => set.Alternator?.LoadPercent?.NodeId ?? NodeId.Null,
|
|
};
|
|
if (!input.IsNull)
|
|
{
|
|
alarm.CreateOrReplaceInputNode(SystemContext, null!).Value = input;
|
|
}
|
|
|
|
alarm.SetEnableState(SystemContext, true);
|
|
alarm.SetActiveState(SystemContext, false);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Evaluates every set's protections and reports state changes as events.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// The trip conditions come from the simulation, which already applies
|
|
/// hysteresis, so an alarm latches and clears cleanly instead of chattering
|
|
/// on the threshold.
|
|
/// </remarks>
|
|
private void EvaluateProtections()
|
|
{
|
|
foreach (KeyValuePair<NodeId, List<ProtectionAlarm>> entry in m_alarms)
|
|
{
|
|
if (!m_simulations.TryGetValue(entry.Key, out GeneratorSimulation? simulation))
|
|
{
|
|
continue;
|
|
}
|
|
|
|
bool shutdown = false;
|
|
foreach (ProtectionAlarm alarm in entry.Value)
|
|
{
|
|
bool active = alarm.IsTripped();
|
|
|
|
// A shutdown-class protection latches. Stopping the engine is
|
|
// what removes the condition that tripped it - oil pressure and
|
|
// coolant temperature are only supervised while the set turns -
|
|
// so following the condition would clear the alarm on the very
|
|
// next tick and leave an operator with a stopped machine and no
|
|
// indication of why. It stays annunciated until ResetFaults,
|
|
// which is what a real control panel does. A warning-class
|
|
// protection does not stop anything, so it follows its condition.
|
|
if (alarm.IsLatched)
|
|
{
|
|
continue;
|
|
}
|
|
|
|
if (active == alarm.WasActive)
|
|
{
|
|
continue;
|
|
}
|
|
alarm.WasActive = active;
|
|
Annunciate(alarm, active);
|
|
shutdown |= active && alarm.IsShutdown;
|
|
}
|
|
|
|
// A shutdown-class protection stops the machine; a warning does not.
|
|
// Reporting a trip without stopping the set would publish a generator
|
|
// that is on fire and still loaded.
|
|
//
|
|
// Tripping is deferred until every protection has been evaluated:
|
|
// stopping the set mid-loop makes its remaining conditions read
|
|
// healthy, so a set that lost oil pressure and overspeed at the same
|
|
// moment would annunciate only whichever came first in the table -
|
|
// exactly the case one-alarm-per-function exists to show.
|
|
if (shutdown)
|
|
{
|
|
simulation.Trip();
|
|
}
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Publishes one alarm's new active state and reports it as an event.
|
|
/// </summary>
|
|
/// <param name="alarm">The alarm whose state changed.</param>
|
|
/// <param name="active">Whether the protection is now tripped.</param>
|
|
/// <remarks>
|
|
/// A client learns of condition state changes only through events, so the
|
|
/// node update and the event have to travel together. Updating the node
|
|
/// alone leaves an alarm-list client showing a stale condition until it
|
|
/// happens to issue a ConditionRefresh.
|
|
/// </remarks>
|
|
private void Annunciate(ProtectionAlarm alarm, bool active)
|
|
{
|
|
DateTime now = DateTime.UtcNow;
|
|
alarm.State.SetActiveState(SystemContext, active);
|
|
alarm.State.CreateOrReplaceRetain(SystemContext, null!).Value = active;
|
|
alarm.State.CreateOrReplaceTime(SystemContext, null!).Value = now;
|
|
alarm.State.CreateOrReplaceReceiveTime(SystemContext, null!).Value = now;
|
|
alarm.State.CreateOrReplaceMessage(SystemContext, null!).Value = new LocalizedText(
|
|
active ? "Protection tripped." : "Protection cleared.");
|
|
alarm.State.ClearChangeMasks(SystemContext, true);
|
|
|
|
var snapshot = new InstanceStateSnapshot();
|
|
snapshot.Initialize(SystemContext, alarm.State);
|
|
alarm.State.ReportEvent(SystemContext, snapshot);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Clears the latched protections of one set.
|
|
/// </summary>
|
|
/// <param name="set">The generator set.</param>
|
|
/// <remarks>
|
|
/// Each clear is reported as an event, for the same reason a trip is: a
|
|
/// client that saw the alarm go active learns it is over only from the
|
|
/// event, so clearing the node silently would leave the alarm displayed as
|
|
/// active and retained indefinitely.
|
|
/// </remarks>
|
|
private void ClearLatchedAlarms(GeneratorSetState set)
|
|
{
|
|
if (!m_alarms.TryGetValue(set.NodeId, out List<ProtectionAlarm>? alarms))
|
|
{
|
|
return;
|
|
}
|
|
foreach (ProtectionAlarm alarm in alarms)
|
|
{
|
|
if (!alarm.WasActive)
|
|
{
|
|
continue;
|
|
}
|
|
alarm.WasActive = false;
|
|
Annunciate(alarm, false);
|
|
}
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// The protections every generating set annunciates.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// A table rather than a switch, so a client-visible property and the condition
|
|
/// that drives it are declared next to each other and cannot drift apart. Held
|
|
/// to the datasheet's trip points by <c>GeneratorProtectionTests</c>.
|
|
/// </remarks>
|
|
internal static class GeneratorProtections
|
|
{
|
|
/// <summary>
|
|
/// Gets the protections, in the order a set publishes them.
|
|
/// </summary>
|
|
public static ArrayOf<ProtectionDefinition> Definitions { get; } = new ProtectionDefinition[]
|
|
{
|
|
new ProtectionDefinition("LowOilPressureAlarm",
|
|
GeneratorProtectionFunctionEnum.LowOilPressure,
|
|
"LubricationSystem", IsShutdown: true, Severity: 900,
|
|
s => s.LowOilPressure),
|
|
new ProtectionDefinition("HighCoolantTemperatureAlarm",
|
|
GeneratorProtectionFunctionEnum.HighCoolantTemperature,
|
|
"CoolingSystem", IsShutdown: true, Severity: 900,
|
|
s => s.CoolantOverTemperature),
|
|
new ProtectionDefinition("OverspeedAlarm",
|
|
GeneratorProtectionFunctionEnum.Overspeed,
|
|
"Engine", IsShutdown: true, Severity: 1000,
|
|
s => s.SpeedRpm > GeneratorDatasheet.TripPoints.OverspeedRpm),
|
|
new ProtectionDefinition("OverloadAlarm",
|
|
GeneratorProtectionFunctionEnum.Overload,
|
|
"Alternator", IsShutdown: false, Severity: 600,
|
|
s => s.LoadFraction > GeneratorDatasheet.TripPoints.OverloadFraction),
|
|
};
|
|
|
|
/// <summary>
|
|
/// Writes what a protection reports onto one alarm node.
|
|
/// </summary>
|
|
/// <param name="alarm">The alarm node to configure.</param>
|
|
/// <param name="context">The system context.</param>
|
|
/// <param name="definition">What the alarm reports.</param>
|
|
/// <remarks>
|
|
/// <c>ProtectionFunction</c> is mandatory on the type, so the generated
|
|
/// factory has already materialised it. <c>IsShutdown</c> and
|
|
/// <c>SubsystemName</c> are <b>optional</b> and have not been.
|
|
/// <c>CreateOrReplace</c> alone is not enough for those: it produces a child
|
|
/// with no <c>ReferenceTypeId</c> and no NodeId, so there is no reference for
|
|
/// a browse to follow and the alarm reports its trip without saying whether
|
|
/// the trip stops the machine or which subsystem to go to. Opting in with
|
|
/// <c>AddXxx</c> first is what gives the child its <c>HasProperty</c>
|
|
/// reference. Every write looks correct in the source; the loss is only
|
|
/// visible from a client.
|
|
/// </remarks>
|
|
public static void ApplyDefinition(
|
|
GeneratorProtectionAlarmState alarm,
|
|
ISystemContext context,
|
|
ProtectionDefinition definition)
|
|
{
|
|
alarm.AddIsShutdown(context);
|
|
alarm.AddSubsystemName(context);
|
|
|
|
alarm.CreateOrReplaceProtectionFunction(context, null!).Value = definition.Function;
|
|
alarm.CreateOrReplaceIsShutdown(context, null!).Value = definition.IsShutdown;
|
|
alarm.CreateOrReplaceSubsystemName(context, null!).Value = definition.Subsystem;
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// One protection a generating set annunciates.
|
|
/// </summary>
|
|
/// <param name="Name">Browse name of the alarm.</param>
|
|
/// <param name="Function">Which protection this alarm reports.</param>
|
|
/// <param name="Subsystem">Subsystem the fault belongs to.</param>
|
|
/// <param name="IsShutdown">Whether tripping shuts the set down.</param>
|
|
/// <param name="Severity">Event severity.</param>
|
|
/// <param name="IsTripped">Evaluates the trip condition against a simulation.</param>
|
|
internal sealed record ProtectionDefinition(
|
|
string Name,
|
|
GeneratorProtectionFunctionEnum Function,
|
|
string Subsystem,
|
|
bool IsShutdown,
|
|
ushort Severity,
|
|
Func<GeneratorSimulation, bool> IsTripped);
|
|
|
|
/// <summary>
|
|
/// One protection alarm and the condition that trips it.
|
|
/// </summary>
|
|
/// <param name="state">The alarm node.</param>
|
|
/// <param name="isTripped">Evaluates the trip condition.</param>
|
|
/// <param name="isShutdown">Whether tripping shuts the set down.</param>
|
|
internal sealed class ProtectionAlarm(
|
|
GeneratorProtectionAlarmState state,
|
|
Func<bool> isTripped,
|
|
bool isShutdown)
|
|
{
|
|
/// <summary>
|
|
/// Gets the alarm node.
|
|
/// </summary>
|
|
public GeneratorProtectionAlarmState State { get; } = state;
|
|
|
|
/// <summary>
|
|
/// Gets whether tripping this protection shuts the set down.
|
|
/// </summary>
|
|
public bool IsShutdown { get; } = isShutdown;
|
|
|
|
/// <summary>
|
|
/// Gets or sets the last reported active state, so only changes raise events.
|
|
/// </summary>
|
|
public bool WasActive { get; set; }
|
|
|
|
/// <summary>
|
|
/// Gets a value indicating whether the alarm is latched on.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// A shutdown-class protection holds its annunciation until it is reset,
|
|
/// because the shutdown removes the condition that caused it: oil pressure
|
|
/// and coolant temperature are only supervised while the engine turns, so an
|
|
/// alarm that followed its condition would clear on the tick after the trip
|
|
/// and leave an operator with a stopped machine and no indication of why.
|
|
/// </remarks>
|
|
public bool IsLatched => IsShutdown && WasActive;
|
|
|
|
/// <summary>
|
|
/// Evaluates the trip condition.
|
|
/// </summary>
|
|
/// <returns><see langword="true"/> when the protection is tripped.</returns>
|
|
public bool IsTripped()
|
|
{
|
|
return isTripped();
|
|
}
|
|
}
|
|
}
|