# Description - Add opt-in bounded browsing and strict reads with original source, status, timestamp, and structured-value evidence. Preserve the existing tolerant constructors and convenience projections, and wire options through session extensions, factories, and hosting registration. - Add selected-result streaming downloads with byte/request limits and independent cleanup, using `TemporaryFileTransferClient.CopyToAsync` from the client/server predecessor. Retain the detailed transfer regressions in the Machinery test layer. - Expose genuinely null unpublished result slots, carry the two Machinery sample updates, and include the complete Machinery guide and package README changes. ## Related Issues - Related tracking issue: #4461; this extraction does not close it. - Frozen source PR: #4462; this extraction does not close or modify it. - Immediate predecessor: #4803 (`marcschier-extract-amb-changes`). The earlier dependencies are client/server #4802 and core/types #4801. ## Checklist _Put an `x` in the boxes that apply. You can complete these step by step after opening the PR._ - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [ ] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received.
74 KiB
OPC UA for Machinery (OPC 40001)
Released Machine Vision (OPC 40100-1/-2) composes into this
manager through AddVisionToMachinery() and ConfigureVisionFor<MachineryNodeManager>().
This reuses the existing DI/Machinery owner; do not register a second asset-owning Vision manager.
The Opc.Ua.Machinery* packages implement the OPC 40001 specification series —
the building blocks every machine shares, plus the four specialised parts that
production equipment adds depending on its use case.
Contents
- Library layout
- Models and namespaces
- Dependency specifications
- Quick start — server
- Quick start — client
- Server hosting model
- Coexisting with a server that already owns DI or ISA-95
- Builder reference
- Abstract event types
- State machines are server-driven
- Client
- Conformance matrix
- Model sources and identifier tables
- Cross-assembly generator behavior
Library layout
Each part is its own model assembly, so a server takes only what it serves. A machine tool that reports jobs and results does not have to carry PADIM.
| Package | Specification | Model URI |
|---|---|---|
Opc.Ua.Machinery |
OPC 40001-1 Basic Building Blocks | http://opcfoundation.org/UA/Machinery/ |
Opc.Ua.Machinery.ProcessValues |
OPC 40001-2 Process Values | …/UA/Machinery/ProcessValues/ |
Opc.Ua.Machinery.Jobs |
OPC 40001-3 Job Management | …/UA/Machinery/Jobs/ |
Opc.Ua.Machinery.Energy |
OPC 40001-4 Energy Management | …/UA/Machinery/Energy/ |
Opc.Ua.Machinery.Result |
OPC 40001-101 Result Transfer | …/UA/Machinery/Result/ |
Two more packages turn those models into a running server and a client:
| Package | What it adds |
|---|---|
Opc.Ua.Machinery.Server |
MachineryNodeManager, the fluent machine builder, the state-machine controllers, the OPC 40001-101 download path, and the AddMachinery() hosting pipeline |
Opc.Ua.Machinery.Client |
MachineryClient — discovery from the Machines folder, identification, state observation, job control and result download |
Models and namespaces
The generated C# namespace of each model is derived from its model URI by
NodeSetToModelDesign.CreateNamespace, and every project pins the derived value
explicitly — it is part of the contract each assembly publishes through
[assembly: ModelDependencyAttribute] (see ModelDependencies.md).
| Model URI | C# namespace | Namespaces member |
Model loader |
|---|---|---|---|
…/UA/Machinery/ |
Opc.Ua.Machinery |
Machinery |
AddOpcUaMachinery |
…/UA/Machinery/ProcessValues/ |
Opc.Ua.Machinery.ProcessValues |
MachineryProcessValues |
AddOpcUaMachineryProcessValues |
…/UA/Machinery/Jobs/ |
Opc.Ua.Machinery.Jobs |
MachineryJobs |
AddOpcUaMachineryJobs |
…/UA/Machinery/Energy/ |
Opc.Ua.Machinery.Energy |
MachineryEnergy |
AddOpcUaMachineryEnergy |
…/UA/Machinery/Result/ |
Opc.Ua.Machinery.Result |
MachineryResult |
AddOpcUaMachineryResult |
…/UA/IA/ |
Opc.Ua.IA |
IA |
AddOpcUaIA |
…/UA/ECM/ |
Opc.Ua.ECM |
ECM |
AddOpcUaECM |
…/UA/PADIM/ |
Opc.Ua.PADIM |
PADIM |
AddOpcUaPADIM |
…/UA/Dictionary/IRDI |
Opc.Ua.IRDI |
IRDI |
AddOpcUaIRDI |
Note on placement: the Machines folder (FolderType) that OPC 40001-1 defines
is Organizes-referenced from Objects, not from the DI DeviceSet. There
is no MachineryItems folder in 1.04.1, and no MachineryBuildingBlocksType —
the building blocks are AddIn instances (Identification, Monitoring,
Components, MachineryEquipment, Notifications).
Dependency specifications
The Machinery models compose types from these companion specifications:
| Package | Specification | Why |
|---|---|---|
Opc.Ua.IA |
OPC 10000-200 Industrial Automation | 40001-1 types MonitoringType.Status.Stacklight with IA's BasicStacklightType. Machinery and Robotics reference this shared model package, avoiding duplicate producers for the same model URI and C# prefix. Its generated types use the Opc.Ua.IA namespace and AddOpcUaIA registration. |
Opc.Ua.PADIM |
OPC 30081 PADIM + the IRDI dictionary | 40001-2 derives ProcessValueType / ProcessValueVariableType from PADIM's AnalogSignalType / AnalogSignalVariableType. IRDI ships in the same assembly because PADIM references it several hundred times and is unusable without it. |
Opc.Ua.ECM |
OPC 34100 Energy Consumption Management | 40001-4's energy carriers are instances of ECM's EnergyMeasurementValueType. |
Opc.Ua.ISA95 |
OPC 10031-4 ISA-95 Job Control V2 | 40001-3's JobManagementType composes the Job Control V2 receiver and response provider. |
The model reference graph:
Opc.Ua.Core
└── Opc.Ua.Di ──┬── Opc.Ua.IA ──┬── Opc.Ua.Robotics
│ ├── Opc.Ua.ECM ─── Opc.Ua.Machinery.Energy
│ └── Opc.Ua.Machinery
└── Opc.Ua.PADIM (+ IRDI) ─── Opc.Ua.Machinery.ProcessValues
Opc.Ua.Core ─── Opc.Ua.Machinery.Result
Opc.Ua.ISA95 ─── Opc.Ua.Machinery.Jobs
Quick start — server
builder.Services
.AddOpcUa()
.AddServer(options =>
{
options.ApplicationName = "MachineryServer";
options.ApplicationUri = "urn:localhost:OPCFoundation:MachineryServer";
options.EndpointUrls.Add("opc.tcp://localhost:62546/MachineryServer");
})
.AddMachinery(options => options.Parts = MachineryParts.All)
.ConfigureMachinery(async machinery =>
{
IMachineHandle<BaseObjectState> press = await machinery
.AddMachine("Press-1")
.WithIdentification(id =>
{
id.Manufacturer = new LocalizedText("Acme");
id.Model = new LocalizedText("P-500");
id.SerialNumber = "SN-0001";
id.ProductInstanceUri = "urn:acme:press:1";
})
.WithMonitoring(monitoring => monitoring
.WithMachineryItemState()
.WithOperationMode())
.BuildAsync();
// The handle is how the application drives the machine afterwards.
await press.ItemState!.SetStateAsync(MachineryItemStateValue.NotExecuting);
});
Nothing reaches the address space until BuildAsync runs, and a failure
anywhere in the chain rolls the machine back — the server is never left with
half a machine.
MachineryParts decides which models the manager loads, which namespaces it
announces and which conformance units it can advertise. Trim it so the server
carries only what it serves:
| Value | Needs |
|---|---|
BuildingBlocks |
DI + IA |
ProcessValues |
BuildingBlocks + PADIM + IRDI |
Jobs |
ISA-95 Job Control V2 only — no DI |
Energy |
BuildingBlocks + ECM |
Result |
UA core only — no DI, no machine model |
A server that publishes nothing but measurement results skips the machine model entirely:
builder.Services
.AddOpcUa()
.AddServer(/* … */)
.AddMachineryResults(options => options.RootBrowseName = "ResultManagement");
That registers MachineryResultNodeManager,
which shares its method binder with the ResultManagement object below a
machine, so both answer a client identically.
Quick start — client
MachineryClient machinery = session.Machinery(telemetry);
await foreach (MachineEntry machine in machinery.EnumerateMachinesAsync(ct))
{
MachineIdentification? id = await machinery
.ReadIdentificationAsync(machine.NodeId, ct);
FiniteStateSnapshot? state = await machinery
.GetItemStateAsync(machine.NodeId, ct);
Console.WriteLine(
$"{id?.Manufacturer.Text} {id?.Model.Text} — {state?.CurrentState.Text}");
}
With the constructor that takes no options, optional-block accessors return
null when a machine does not publish the block: OPC 40001-1 makes nearly
everything optional, so a client that insists on a block would work against
one vendor and fail against the next.
Server hosting model
AddMachinery() registers MachineryNodeManager, a DiNodeManager subclass —
the same shape RoboticsNodeManager has. One manager serves every configured
part, because the parts share one instance tree: a machine's process values,
jobs, energy carriers and results all hang off the same object.
ConfigureMachinery(...) runs during server startup, after the models are
loaded and the address space is wired. Three overloads take a delegate
(sync, async, async with token) and one takes an IMachineryConfigurator
class, which is the one to reach for when the configuration needs services
from the container.
Instances are minted into an application-owned namespace,
MachineryServerOptions.InstanceNamespaceUri
(default urn:opcua-netstandard:machinery:instances). It must not be a model
namespace, and the options validate that.
Coexisting with a server that already owns DI or ISA-95
AddMachinery() claims the Device Integration address space, and — when the
Jobs part is selected — the ISA-95 namespaces as well. A second registration
that would load the same models fails immediately with a message naming the
current owner, rather than producing a server with two DeviceSet trees.
A server that already owns either one loads the Machinery models into its own manager and drives them through the same builder:
protected override ValueTask<NodeStateCollection> LoadPredefinedNodesAsync(
ISystemContext context, CancellationToken ct = default)
{
var nodes = new NodeStateCollection();
nodes.AddMachineryTypeSystem(context, MachineryParts.BuildingBlocks);
nodes.AddOpcUaPumps(context);
return new ValueTask<NodeStateCollection>(nodes);
}
builder.ConfigureMachineryFor<PumpNodeManager>(async machinery =>
{
await machinery.AddMachine(pump, new QualifiedName("Pump-1"))
.WithIdentification(/* … */)
.BuildAsync();
});
AddMachine<TState>(TState machine, …) adopts an instance a companion
specification created — an OPC 40223 PumpState, an OPC 40223-style
GeneratorSetState — so the vendor model keeps its own type definition and
still answers the Machinery browse paths. The custom manager only has to expose
an IMachineryNodeIdFactory or the shared DI ICompanionNodeIdFactory;
MachineryNodeManager implements both. A custom manager supplies a thread-safe
allocator for the configured instance namespace. The Robotics allocator marker
also derives from the shared marker, allowing both families to reuse one owner
when their required models are loaded and their instance namespaces agree.
The optional ICompanionNodeIdReservationOwner capability releases temporary
reservations through the actual allocator on success or rollback; both stock
managers implement this capability separately from their allocator markers.
When a companion already declares its nameplate, bind it with
machine.WithIdentification(existingIdentification, configure) instead of
creating another base add-in. Derived machine identification and nested
component identification are both supported. The type, parent, browse name,
NodeId and reference type remain intact, and MachineryBuildingBlocks points
at that same node. Required identification values are validated before the
existing nameplate is changed; machine and component requirements remain
distinct.
Bindings on an externally registered root
When Robotics owns a companion root under DeviceSet, do not also call
AddMachine(root).BuildAsync(): that adopts the root as a Machinery-owned
machine. Instead enlist shared bindings in the Robotics registration:
system.WithRegistrationParticipant(machineryContext.BindMachine(
craneState,
machine => machine.WithIdentification(craneState.Identification!, identity =>
{
identity.Manufacturer = new LocalizedText("Example manufacturer");
identity.SerialNumber = "CR-1";
identity.ProductInstanceUri = "urn:example:crane:CR-1";
})));
system is the builder supplied to AddMotionDeviceSystemAsync<TState>.
Both contexts must use the same node manager and application namespace.
The binding callback runs before publication and reuses the normal Machinery
writer; it must not call BuildAsync or change the root's identity.
Robotics validates and registers the entire subtree once. Machinery adds
Machines organizing references without changing the root's DeviceSet
parent or HasComponent reference. Facets commit only after every participant
has bound successfully. Failure or cancellation releases the participant's
references, resources and reservations, while only the registration owner
removes its own attempted tree.
The DI-level ICompanionRegistrationParticipant is single-use. Its
PrepareAsync and BindAsync phases may fail; Commit must not perform I/O
or throw. The owner disposes participants in reverse order on every path.
Committed Machinery bindings use the existing node-attachment lifetime,
including on an existing Robotics manager: deleting the root or stopping the
manager releases its bindings without a second owner or manager-wide registry.
For either an ordinary machine builder or an enlisted one,
WithRegistrationBinding(async (state, context, cancellationToken) => resource)
defers an asynchronous binding until after indexing. The returned
IAsyncDisposable is owned by the transaction: a later failure disposes it,
and success transfers it to the existing machine lifetime. If configuration
throws before an ordinary BuildAsync is called, await builder.AbortAsync()
to release the unused name and allocations. Aborting cannot remove a
registered machine and permanently closes that builder.
For ordinary machine builders, successful registration groups the owned resources behind the exact root node. Deleting that root awaits reverse-order cleanup without touching another machine's resources. Manager shutdown joins any pending cleanup and releases remaining roots; a removed root does not retain an ever-growing entry in the coordinator. This uses the manager's actual asynchronous node-removal hook, not a value change-mask callback.
Builder reference
OPC 40001-1 building blocks
Every block is attached to its machinery item with HasAddIn, which is what
OPC 40001-1 uses — not HasComponent.
For a companion-created or vendor-derived Components AddIn,
machine.WithComponents(existingComponents, configure) reuses the existing
MachineComponentsState. Its parent, qualified name, NodeId, reference and
type definition are preserved. The node must be a descendant of this machine,
derive from MachineComponentsType, and retain a HasAddIn reference or
subtype. Existing child names are reserved rather than silently replaced.
| Call | What it adds |
|---|---|
WithIdentification(…) |
Identification, typed MachineIdentificationType. The browse name comes from the DI namespace because the type derives from DI's FunctionalGroupType. Manufacturer, SerialNumber and (for a machine) ProductInstanceUri are mandatory and validated. |
WithMonitoring(…) |
Monitoring, and below it Status/MachineryItemState, Status/MachineryOperationMode, Status/Stacklight (OPC 10000-200 IA), Health, Process, Consumption — each only when asked for |
WithComponents(…) |
Components, and one AddComponent per machine component. A component gets the narrower MachineryComponentIdentificationType. |
WithMachineryEquipment(…) |
MachineryEquipment and the equipment below it. MachineryEquipmentTypeId is mandatory and required by the call; WithEquipmentLife(…) adds the DI LifetimeVariableType the equipment interface declares. |
WithNotifications(…) |
Notifications, with EventNotifier set, registered as a root notifier, and a publisher the application reports its own events on |
WithOperationCounters(…) |
OperationCounters — PowerOnDuration, OperationDuration, OperationCycleCounter |
WithLifetimeCounters(…) |
LifetimeCounters and one DI LifetimeVariableType per AddLifetimeVariable |
The MachineryBuildingBlocks organizer
OPC 40001-1 §7.1 puts the building blocks below a FolderType object named
MachineryBuildingBlocks (Machinery namespace), referenced from the machinery
item with HasComponent, and the blocks themselves with HasAddIn from that
folder. Table 12 of the specification says the item state, the operation mode,
both counters, monitoring, equipment and notifications shall be reachable
that way, and identification and the components folder may be.
This is not presentation. Every conformance unit for those blocks is worded
"has this AddIn under its MachineryBuildingBlocks folder", and OPC 40001-3's
Machinery Job Management Base is worded the same way — so a server without
the folder satisfies none of them. The builder creates it on first use and
references every block it builds; §7.3 forbids duplicating the node, so the
second path is a reference to the same node, not a copy. The blocks keep their
direct HasAddIn from the machinery item as well, which §7.1 recommends as the
top-level entry point.
There is no MachineryItems folder and no MachineryBuildingBlocksType in
1.04.1 — both appear in older drafts and in reduced NodeSet copies. The folder
has no type of its own: it is a plain FolderType identified by its browse
name, which is why the builder assembles it rather than a generated factory.
The Machines folder is Organizes-referenced from Objects.
Default instance browse names are load-bearing
Every OPC 40001-1 conformance unit is worded "using the
DefaultInstanceBrowseName", so the namespace a block's browse name sits in is
part of the contract, and it is not always the Machinery one:
MachineryOperationCounterType declares 2:OperationCounters — the Device
Integration namespace — because OPC 40001-1 reuses the OPC 10000-100 functional
group so a client written against Device Integration finds it.
MachineryItemIdentificationType and its two subtypes do the same with
2:Identification. MachineryNodeSetConformanceTests pins all ten values
against the vendored NodeSet.
OPC 40001-2 process values
.WithProcessValue(new QualifiedName("OilTemperature"), pv => pv
.WithEngineeringUnits(degreeCelsius, new Range { Low = -20, High = 120 })
.WithLimits(lowLow: 5, low: 15, high: 65, highHigh: 80)
.WithSetpoint(45)
.WithDeviationLimits(low: -10, high: 10)
.WithPercentageValue()
.WithStatus()
.WithLimitAlarm()
.WithDeviationAlarm()
.WithZeroPointAdjustment(async (processValue, ct) => await ZeroAsync(ct))
.WithValue(45)
.Bind(out IProcessValueHandle oilTemperature))
The application drives the value through the handle afterwards, and everything derived from it follows:
await oilTemperature.SetValueAsync(70.0); // percentage, both alarms
await oilTemperature.SetSetpointAsync(55); // deviation alarm
For acquired data, SetValueAsync(in DataValue, cancellationToken) preserves
the original numeric scalar type, quality and acquisition timestamp. An
unavailable sample can carry Variant.Null with a bad status; it is not
converted into a fresh zero or used to clear the last alarm. Incompatible
payloads and canceled updates leave the previous sample unchanged. The
percentage value carries the same quality and source time. Convenience
double-valued updates use an injected TimeProvider, or TimeProvider.System
when no provider is registered.
MachineryProcessValue.Sample returns the full signal DataValue on the client,
including uncertain or bad quality and both service timestamps. It complements
the numeric Value projection rather than silently normalizing a
failed or unavailable reading.
machine.WithProcessValue(existingProcessValue, configure) adopts a
companion-derived descendant without replacing either its object or signal.
The signal must already use the standard ProcessValueVariableType subtype
and keep its PADIM-qualified AnalogSignal browse name. A companion builder
selects that permitted subtype when constructing the instance; an incompatible
existing signal is rejected rather than replaced. Nested descendants are
supported and remain under their declared parent.
WithLimitAlarm() and WithDeviationAlarm() do more than create the objects
the model declares. Each one mirrors the limits onto the alarm — absolute
limits from WithLimits, deviations from WithDeviationLimits — points the
condition at the signal as its InputNode, gives it the source, name and
enable state OPC 10000-9 needs, registers it as a root notifier, and
re-evaluates it on every SetValueAsync. An alarm that is only created never
activates and never reports, which is what the objects alone amount to.
WithZeroPointAdjustment binds the optional OPC 30081 method and reports a
ZeroPointAdjustmentEventType event on every call — the part's conformance
unit says all instances supporting the method do — with the handler deciding
only the ZeroPointAdjustmentResult status the event carries. Because that
event type is abstract, the event is reported with a concrete subtype; see
Abstract event types.
ProcessValueType derives from PADIM's AnalogSignalType, and its mandatory
AnalogSignal child keeps PADIM's AnalogSignalVariableType as its declared
type — OPC 40001-2 does not narrow it. What the part adds is
ProcessValueVariableType, a subtype of that variable type carrying
LowLowLimit / LowLimit / HighLimit / HighHighLimit and
PercentageValue. An instance may use a subtype in a declared slot, so the
builder puts the richer type there and the limits become reachable. The
generated factory alone would leave the PADIM type in place and
WithLimits(...) would have nowhere to write.
The generated subtype preserves inherited reference types and browse-name
namespaces, including when ProcessValueVariableType is instantiated directly.
SignalTag is a mandatory PA-DIM property, and EngineeringUnits is a
namespace-0 property used by Data Access clients and the
0:Data Access AnalogUnitType unit of the OPC 40001-2 base facet.
These attributes travel through the cross-assembly dependency payload; see
Cross-assembly generator behavior.
OPC 40001-3 job management
.WithJobManagement(jobs => jobs
.WithJobOrderReceiver(provider)
.WithJobResponseProvider(provider)
.WithJobOrderCatalog(provider))
JobManagementType has exactly two mandatory children: JobOrderControl, an
ISA-95 JobOrderReceiverObjectType, and JobOrderResults, an ISA-95
JobResponseProviderObjectType. The eleven job verbs — Store,
StoreAndStart, Start, Stop, Abort, Pause, Resume, Clear,
Cancel, Update, RevokeStart — belong to the ISA-95 type, not to
OPC 40001-3, and are bound by the shared
Isa95JobControlV2Binder
that Isa95NodeManager uses. A client therefore sees the same verbs with the
same semantics whether it reaches them through a stand-alone ISA-95 root or
through a machine.
When no provider is supplied explicitly the builder resolves
IIsa95JobOrderReceiverV2 from the application services, so
AddInMemoryIsa95JobControlProvider() is enough for a demo server.
Companion models can bind an already-declared job-management child with
machine.WithJobManagement(existingJobManagement, configure). This overload
preserves the child's identity and validates both the receiver and response
provider before publishing the machine. Explicit per-machine providers never
borrow another instance's catalog from the container. The
WithJobManagement(configure) overload uses receiver-only provider validation;
choose the companion overload when complete response handling is
required.
MachineryEndToEndTests.JobControlPausesResumesAndRevokesStartThroughAMachineAsync
drives Pause, Resume and RevokeStart through a machine over opc.tcp,
both the accepted transitions and the refused ones (revoking a running order,
pausing one that is not running, resuming one that is), and checks the state
the published JobOrderList reports after each.
JobOrderList and JobOrderResponseList are snapshots the builder keeps
current from the provider's change streams, because a machine changes its
orders by routes that never pass an OPC UA method: IIsa95JobStatusSourceV2
and IIsa95JobOrderCatalogChangeSource refresh both lists, and
IIsa95JobResponseChangeSource refreshes the response list when the machine
reports a response while the order keeps running — progress such as
RunsCompleted, which changes neither the order's state nor the catalog.
InMemoryIsa95JobControlProvider implements all three.
OPC 40001-4 energy
.WithEnergy(energy => energy
.AddResource(MachineryEnergyCarrier.CompressedAir, air =>
{
air.Main
.WithApplicationTag("press/CompressedAir")
.WithNonElectricalEnergy(importHighPrecision: 0, exportHighPrecision: 0)
.WithVolumeFlow(volume: 184_320f, volumeFlowRate: 18.4f)
.WithBaseFlow(pressure: 620_000f, temperature: 294.65f);
air.AddMeteringPoint(
new QualifiedName("ClampingCylinders"),
point => point.WithNonElectricalEnergy(0, 0));
}))
OPC 40001-4 is an extension of the OPC 40001-1 Monitoring building block
rather than a block of its own (§6.1), and its structure is three levels deep:
Monitoring
Consumption ← OPC 40001-1 MonitoringType
CompressedAir ← well-known FolderType browse name, §9.1
Main ← well-known EnergyMeasurementType name, §9.2
ClampingCylinders ← further metering points
A metering point is an OPC 34100 EnergyMeasurementType object that
implements INonElectricalEnergyType and the flow interfaces; the interfaces
are abstract, so nothing is ever an instance of them. WithEnergy materialises
the monitoring add-in and the Consumption folder when the machine does not
already publish them, and AddResource always creates Main — the
Machinery Energy Main grouping unit requires one for each resource folder,
so a resource without it would make the server non-conformant for every other
resource too.
Contains (§8.1) runs from the main metering point to a sub-meter whose
readings are part of it. Both ends must be EnergyMeasurementType objects,
which is why it never points at a resource folder or at the same-named Object
the Energy model carries — those Objects exist only to publish the well-known
browse names.
Electricity is the one resource OPC 40001-4 describes with no interfaces of its
own: §6.5 defers it to OPC 34100's energy profiles. WithInterface and
AddMeasurementValue are how a metering point takes one:
.AddResource(MachineryEnergyCarrier.Electricity, electricity =>
electricity.Main
.WithApplicationTag("press/Electricity")
.WithInterface(NodeId.Create(
Opc.Ua.ECM.ObjectTypes.IEnergyProfileE1Type,
Opc.Ua.ECM.Namespaces.ECM,
context.Context.NamespaceUris))
.AddMeasurementValue(
new QualifiedName(Opc.Ua.ECM.BrowseNames.AcActivePowerTotal),
Variant.From(41_250.0f),
watt))
The units OPC 40001-4 pins are the UNECE Recommendation 20 codes from its
attribute tables and are applied by the builder: watt hours for the two energy
readings, pascal for Pressure, kelvin for Temperature.
OPC 40001-101 results
.WithResultManagement(results => results
.WithInMemoryStore(capacity: 32)
.WithResultsFolder(publishedResults: 4)
.WithFileTransfer())
All five methods of ResultManagementType are optional; the builder publishes
GetLatestResult, GetResultById, GetResultIdListFiltered,
AcknowledgeResults and ReleaseResultHandle once a store is bound, and the
ResultTransfer object only when downloads are enabled.
For a companion-declared subtype, use
machine.WithResultManagement(existingResultManagement, configure) instead of
creating a second base add-in. The existing descendant keeps its parent, browse
name, NodeId, type definition and reference type, while the shared runtime
supplies queries, metadata handles, publication and file-transfer lifetime.
Foreign descendants and duplicate bindings are rejected. Stores are validated
before the machine is published, and method nodes are staged before indexing.
results.WithResultsFolder(count, createResult) accepts a typed result-variable
factory, and results.WithResultReadyEvents(eventTypeId, createEvent) selects a
derived result-ready event factory. The event factory receives the result being
published; any specialized result child it creates is retained. Abstract event
declarations stay unchanged: the runtime registers a concrete subtype in the
application namespace. These overloads are extensions in
Opc.Ua.Machinery.Server.Builders, so they require no additional members on
builder-interface implementations.
The WithResultReadyEvents(eventTypeIds, createEvent) overload accepts one to
sixteen distinct declared result-event bases. A factory can select a different
configured base for each result, such as a companion's intermediate-result
event instead of its final-result event. Every selected base gets a concrete
application subtype; unconfigured or unrelated types are rejected.
WithResultProjection(prepareProjection) captures validated immutable
companion fields and sample metadata once per publication, before storage.
It returns a synchronous assignment-only projection over the supplied result
variable. The shared writer applies that projection after setting the standard
result fields and before issuing change notifications, including the result
inside events. A fixed ring retains the projection with its result when slots
shift, so acquisition time, quality and derived fields do not depend on the
backing store still retaining an old entry. Projection assignments must not
perform I/O or recursively publish results.
Bringing your own store
Substitute a real store by implementing
IMachineryResultStore
and passing it to WithStore(...), or by registering it in the container. The
machine's result publisher (IMachineHandle.Results, and Publisher on the
stand-alone MachineryResultNodeManager) works with any store:
- a store that also implements
IWritableMachineryResultStorereceives every published result throughAddResultAsync—InMemoryMachineryResultStoreis one; - a store that fills itself through a path of its own — a database a PLC
gateway writes to — does not implement it. Publishing then only announces
the result: the result variables and the
ResultReadyEventTypeevent. The store has to hold the result already; one it cannot return fromGetResultByIdAsyncis refused withBad_InvalidState, because an event must not announce a result the methods cannot hand out.
With WithPredefinedResultMetaData() the metadata check runs before the store
sees the result, whichever kind of store it is.
Filtering and ordering the result list
GetResultIdListFiltered evaluates both arguments OPC 40001-101 §7.1.3
defines:
filteris aContentFilterwhose BrowsePaths "can be built from the fields of theResultReadyEventType, theResultTypeVariableType or theResultDataType". All three spellings resolve to the same field — an optional leadingResult, thenResultMetaData(with its fields, andProcessingTimesone level further down) orResultContent— and names are matched without their namespace index, because a DataType field has none. The comparison, logical andLike/Between/InList/OfType/bitwise operators are supported;InViewandRelatedToneed a node and are FALSE.orderedBysorts by each RelativePath in turn, ascending. Results that leave a key unset sort last, and results that tie keep the store's newest-first order. An emptyorderedBy"executes no ordering", so the store's own order stands.maxResultscaps the list after filtering and ordering; zero means no cap.
Most metadata fields are optional, so NULL handling decides what a filter
returns. The evaluator follows OPC 10000-4 §7.7.3: a comparison with an unset
field is NULL and never selects a result — neither does its negation — and only
IsNull sees the missing value. An optional field counts as set when its
encoding-mask bit is set or when it carries a non-default value; deciding that
needs the structure, which is why the result query carries
its own evaluator
next to the stack's node-oriented FilterEvaluator. Both apply the same NULL
rules.
An invalid filter is refused with Bad_ContentFilterInvalid, an orderedBy
path that names no field with Bad_InvalidArgument.
The query reads the candidates through GetResultIdsAsync(0) and
GetResultByIdAsync, so filtering and ordering require no additional custom-store
methods. The timeout argument of the three getters is the client's hint for
how long it will need the data (§6.4); it is not a deadline for the call.
Downloads, and the refused write side
ResultTransferType derives from TemporaryFileTransferType, so the download
is the standard OPC 10000-5 sequence: GenerateFileForRead returns a transient
FileType object and a handle that is already open, the client reads from
it and closes it.
MachineryResultTransferManager
serves it in the shape SoftwareUpdateFileTransferManager uses for DI
software uploads: one transient FileState per handle, the handle bound to
the session that opened it, a cap on concurrent handles, and a timeout after
which an inactive handle is reclaimed. Pending generations also consume the
cap. Inactivity for a still-live session is swept at the next
GenerateFileForRead; session termination and shutdown are independently
awaited. A successful CloseSession, including deleteSubscriptions=false,
waits for that owner's pending generation or rollback, transient-node deletion
and capacity release. Other sessions retain their own handles. Providers and
registration callbacks must honor cancellation or complete; cleanup does not
abandon an unbounded late operation.
GenerateFileForWrite and CloseAndCommit are mandatory on every
TemporaryFileTransferType (OPC 10000-20 §4.4.1), so a ResultTransfer
object always carries them, and they answer. OPC 40001-101 §7.2.1 leaves
GenerateFileForWrite unspecialised "as results are supposed to be only
generated by the Server, not received", which is the read-only case
OPC 10000-20 names a code for: GenerateFileForWrite returns
Bad_NotWritable (§4.4.4), and CloseAndCommit returns
Bad_InvalidArgument (§4.4.5) for any handle — a download handle included,
which stays open and is closed with the file's own Close.
WithResultsFolder publishes the most recent results as ResultType variables
as well, which is what the Machinery-Result ResultVariables unit asks for —
an empty folder satisfies nothing. The variables are a fixed ring created with
the machine: the newest result lands in the first slot and the others shift
down, so a client can subscribe to a slot once and keep receiving results, and
the server never adds or deletes nodes while it runs.
Before a slot receives its first result, its value and structured parts are genuinely null. Model-default XML is not a published result and is not exposed as one. A present Good-null slot has no ResultId to inspect or download; clients can keep monitoring the same slot until the publisher fills it.
GetLatestResult, GetResultById and GetResultIdListFiltered each return a
ResultHandle that pins what they handed out until the client calls
ReleaseResultHandle. The handle is bound to the calling session, and
releasing one twice is refused. Closing or expiring the session reclaims only
its metadata handles. A late store response cannot pin additional metadata for an
ended session, and removal of the bound machine releases the lifecycle hook.
Because the payload is materialised from the store before the method returns,
GenerateFileForRead returns NodeId.Null for completionStateMachine — the
value OPC 10000-5 defines for "no completion state machine".
Abstract event types
Two of the event types the series declares are abstract:
OPC 40001-101's ResultReadyEventType and OPC 40001-2's
ZeroPointAdjustmentEventType. OPC 10000-3 forbids an instance of an abstract
type, and a client filtering on a concrete EventType never sees an event
reported with an abstract one — so a server that means to publish them has to
derive a concrete subtype of its own.
MachineryConcreteEventTypes
mints one per node manager into the application-owned instance namespace and
every object reporting that event shares it; deriving one per instance would
multiply types a client has to know about for no gain. Both the
TypeDefinitionId and the EventType field are set, because the second is
what an event filter actually selects on.
Isa95NodeManager.CreateV2StatusEventTypeAsync does the same for the ISA-95
job-order status event.
The client side mirrors it. An OfType filter on the abstract type still
selects the subtype — that is what OfType means — but the generated decoder
registry is keyed by the exact event type, so
MachineryClient.Events
re-decodes against the declared abstract type once the session's type cache
confirms the subtype relationship.
State machines are server-driven
Both OPC 40001-1 state machines — MachineryItemState_StateMachineType with
Executing / NotExecuting / NotAvailable / OutOfService, and
MachineryOperationModeStateMachineType with None / Maintenance / Setup /
Processing — declare four states and sixteen transitions each, including the
self-transitions. Neither declares a cause method. The whole Machinery
NodeSet contains no UAMethod at all, so a client can never request a
transition.
The server surface follows: IMachineryItemStateController.SetStateAsync and
IMachineryOperationModeController.SetModeAsync, reachable from the machine
handle. There is deliberately no WithCause.
await press.ItemState!.SetStateAsync(MachineryItemStateValue.Executing);
await press.OperationMode!.SetModeAsync(MachineryOperationModeValue.Processing);
The state and transition tables live in
MachineryStateMachineTables,
spelled out from the generated *TypeIds constants — the generator emits these
two types as plain FiniteStateMachineState subclasses without the stack's
StateTable / TransitionTable / TransitionMappings overrides, so the
stack's own SetState would write nothing. The driver still invokes the
machine's OnBeforeTransition / OnAfterTransition delegates around the
variable update, which is exactly where StateMachineBuilder.For(...) installs
its guards and observers, so the repository's state-machine lifecycle surface
keeps working.
Client
MachineryClient starts at the Machines folder, so it needs no configured
NodeIds and works against a server it has never seen.
| Concern | API |
|---|---|
| Discovery | EnumerateMachinesAsync, DiscoverMachinesAsync, EnumerateComponentsAsync, EnumerateBuildingBlocksAsync |
| Identification | ReadIdentificationAsync — one TranslateBrowsePaths plus one batched Read |
| State | ItemStateAsync / OperationModeAsync return the generated FSM proxies; GetItemStateAsync / ObserveItemStateAsync wrap them |
| Health | ReadDeviceHealthAsync |
| Counters | ReadOperationCountersAsync, ReadLifetimeCountersAsync |
| Equipment | EnumerateEquipmentAsync — including EquipmentLife |
| Process values | EnumerateProcessValuesAsync, ReadProcessValueAsync, ZeroPointAdjustmentAsync, ObserveZeroPointAdjustmentsAsync |
| Energy | ResolveConsumptionAsync, EnumerateEnergyResourcesAsync, EnumerateMeteringPointsAsync, ReadMainMeteringPointAsync, ReadMeteringPointAsync, and for the sub-meters a point Contains EnumerateSubMetersAsync / ReadSubMetersAsync |
| Jobs | JobManagementAsync returns the ISA-95 Isa95JobControlV2Client; ReadJobOrdersAsync / ReadJobResponsesAsync read the published lists; ReadJobOrderParametersAsync / ReadJobResponseParametersAsync return the predefined OPC 40001-3 parameters typed |
| Results | ResultManagementAsync (whose GetResultIdListFilteredAsync takes the filter and order), DownloadResultAsync, ReadPublishedResultsAsync, ObserveResultsAsync |
| Notifications | ResolveNotificationsAsync, ObserveNotificationsAsync |
| Device Integration | Topology — for a machine that is also a DI device |
Process values are found by type definition rather than by browse path:
OPC 40001-2 does not fix where they hang — its examples put them on a sensor
component, on the machine, and below Monitoring — so every object below the
item whose type is ProcessValueType counts.
A metering point's measurements are read with one browse and one batched
Read. Each MachineryMeasurementValue carries the NodeId of the variable
its reading came from next to the value, so a client that wants live values
subscribes to those nodes without browsing the point again:
MachineryMeteringPoint? main = await machinery.ReadMainMeteringPointAsync(resource, ct);
foreach (MachineryMeasurementValue measurement in main!.Measurements)
{
subscription.TryAddMonitoredItem(
measurement.BrowseName.Name!,
measurement.NodeId,
options => options with { SamplingInterval = TimeSpan.FromSeconds(1) },
out _);
}
State observation rides the generated *StateMachineTypeClient proxies, which
inherit GetCurrentFiniteStateAsync, ObserveFiniteTransitionsAsync and
WaitForStateAsync from FiniteStateMachineTypeClient — so a vendor subtype of
either state machine is observed the same way. See
StateMachines.md.
Constructing the client registers the OPC 40001-101 and OPC 40001-3
structured types, and the ISA-95 Job Control V2 ones the job lists travel as,
with the session's encodeable factory, so GetLatestResult decodes into
ResultDataType and JobOrderList into ISA95JobOrderAndStateDataType
instead of an opaque ExtensionObject.
The predefined job parameters of OPC 40001-3 §7.2 Table 1 travel as ISA-95
key-value pairs rather than as nodes, so the client reads them out of the
payload: MachineryJobOrderParameters.FromJobOrder and
MachineryJobResponseParameters.FromJobResponse return each one with the
type the table declares — Duration in milliseconds, the series' own
enumerations as JobExecutionMode / JobResult, and Overproduction from
where Table 1 puts it, below PlannedOrderQuantity — and keep every
parameter as received in Parameters. A parameter with the wrong type counts
as not carried in these convenience projections. Optional fields of the
generated ISA-95 structures, such as JobOrderParameters and Subparameters,
only reach the wire when their EncodingMask bit is set.
Bounded, evidenced inspection
The two-argument constructor and session.Machinery(telemetry) use tolerant
reads. For inspection that must not confuse an unreadable value with an absent
building block, opt into strict reads:
MachineryClient machinery = session.Machinery(telemetry, new MachineryClientOptions
{
MaximumBrowseReferences = 1024,
MaximumBrowsePages = 128,
MaximumReadArrayItems = 1024
});
// Discovery reads identities, not every machine's details.
await foreach (MachineEntry machine in machinery.EnumerateMachinesAsync(ct))
{
Console.WriteLine($"{machine.NodeId}: {machine.DisplayName}");
}
// Read details only for a selected machine.
MachineIdentification? identification =
await machinery.ReadIdentificationAsync(selectedMachineId, ct);
if (identification is not null)
{
foreach (MachineryReadValue field in identification.Values)
{
Console.WriteLine(field.IsAbsent
? $"{field.BrowsePath}: not published"
: $"{field.SourceNodeId}: {field.Value.WrappedValue}, " +
$"{field.Value.StatusCode}, source={field.Value.SourceTimestamp}, " +
$"server={field.Value.ServerTimestamp}");
}
}
MachineryStateSnapshot? state = await machinery.ReadItemStateAsync(selectedMachineId, ct);
MachineryReadValue health = await machinery.ReadDeviceHealthValueAsync(selectedMachineId, ct);
The same immutable options can be passed to
new MachineryClient(session, telemetry, options),
new MachineryClientFactory(sessionFactory, telemetry, options) or
AddMachineryClient(options) on the client builder. Each construction
path validates positive limits and copies the options. The session is borrowed,
never closed or disposed.
Strict reads require Good service, operation and value statuses, exact response
and diagnostic counts, and one complete local translation target.
Ambiguous, remote, incomplete or unknown-namespace targets fail without changing
the namespace table. Only an optional path's BadNoMatch denotes absence;
missing mandatory fields, denied reads, Uncertain quality, wrong wire types and
malformed responses are errors, not null/default values. A published Good-null
value is present (IsAbsent == false). Scalar UInt32 fields reject a
StatusCode payload even though Variant.TryGetValue(out uint) can accept it.
MachineryReadException derives from ServiceResultException: its StatusCode
preserves the actual non-Good status, or describes a type/shape/limit failure.
ReadValue identifies the offending source and qualified path and retains the
original DataValue when one was returned, including both timestamps and
picoseconds. Translation failures and requests without a returned value instead
carry synthetic status evidence. The failure's status does not overwrite an
original Good DataValue when the payload has the wrong type.
| Inspection | Evidence API |
|---|---|
| Identification, operation/lifetime counters, equipment, process values, meters and measurements | Records expose ArrayOf<MachineryReadValue> Values; tolerant reads leave this empty |
| Item state and operation mode | ReadItemStateAsync / ReadOperationModeAsync return MachineryStateSnapshot with the compatible State, Values, optional CurrentStateNumber, LastTransitionNumber and TransitionTime |
| Health | ReadDeviceHealthValueAsync returns one MachineryReadValue; ReadDeviceHealthAsync retains its enum projection |
| Published job lists | ReadJobOrdersSnapshotAsync / ReadJobResponsesSnapshotAsync return typed arrays plus original list evidence |
| Published result identities | EnumeratePublishedResultsAsync does not read result content |
| Selected published result | ReadPublishedResultAsync(resultVariableId, ct) returns MachineryResultSnapshot without downloading a file or requesting a result URI |
| Explicit multi-result inspection | ReadPublishedResultSnapshotsAsync reads one variable per consumed iteration; stopping enumeration prevents further value reads |
Evidence-specific APIs use strict reads, with default limits when the client
is constructed without options. Enum, array and FiniteStateSnapshot APIs
provide convenience projections; use the evidence APIs to distinguish absent,
empty and Good-null values.
Each result owns its evidence: overlapping calls do not share mutable
last-read state.
Browse limits are checked during Browse/BrowseNext traversal, before
accumulating a page or deduplicating identities. Duplicate references and empty
pages count. Process-value discovery shares its budget across the machine and
Monitoring roots. Continuation points are opaque and may remain unchanged while
pages advance; the page and reference budgets still bound the traversal.
Exceeding a budget fails with BadEncodingLimitsExceeded, never silently
truncates a result. Outstanding points are released using an independent
five-second deadline that also bounds an unresponsive release call. Standard
empty release responses and validated per-point responses are accepted.
If traversal and cleanup both fail,
AggregateException preserves the primary failure first.
Bounded browsing and selected-result downloads capture one authenticated
ManagedSession generation for their service calls and cleanup. Result-path
resolution is part of that same download scope. Recovery invalidates the scope
instead of forwarding an old continuation point, resolved target or handle to
a replacement session. Ordinary borrowed sessions are checked for a changed
SessionId; callers must not independently retarget their transport or identity
while an operation is running.
Strict lifetime counters and a present EquipmentLife require StartValue
and LimitValue. Their scalar Number fields accept floating-point and integer
values; WarningValues accepts either a scalar Number or a one-dimensional
numeric array. The ArrayOf<double> warning projection is populated
only for Double arrays; other valid forms remain unmodified in Values.
Operation durations retain their Double-only wire contract.
Strict meters require ApplicationTag, while a published Good-null tag remains
present. Measurements are checked against their published DataType and
ValueRank, including the ECM AcPeDataType and AcPpDataType structures.
Properties such as IA StartTime remain in Values rather than being reported
as numeric measurements; StartTime must carry a DateTime. Clients constructed
without options use tolerant projections.
MaximumReadArrayItems bounds decoded arrays and the aggregate modeled array
items in each job-list or result snapshot, including nested parameter arrays.
OPC 40001-2 permits Number arrays for AnalogSignal and Setpoint; strict reads
retain those bounded arrays in Values, with a null scalar convenience
projection. Scalar numeric projections can lose integer precision; the original
Variant remains authoritative. These limits do not bound transport decoding
or opaque vendor ExtensionObject bodies. Configure the session's message,
array, string and ByteString quotas as well.
Missing optional model namespaces and building blocks remain normal absence.
Where a value-level evidence API reports a missing namespace,
MissingNamespaceUri names it without inventing an index. A published model
missing a required dependency is a failure.
In strict mode, ReadJobResponseParametersAsync inspects only the published
response list without invoking response-request methods. An
absent catalog or unlisted order therefore returns null; multiple matching
responses fail explicitly. Static FromJobOrder / FromJobResponse projections
use tolerant extraction. Generated proxies, the Topology client, event
subscriptions, job commands and result-file transfers have their own contracts;
these options do not harden those separate surfaces.
EnumerateEquipmentAsync is a detailed equipment reader, not an
identity-only browse.
Job endpoints and streamed results
GetJobManagementEndpointsAsync returns the machine's actual job roles:
MachineryJobManagementEndpoints endpoints =
await client.GetJobManagementEndpointsAsync(machineId, ct);
if (!endpoints.JobResponseProviderId.IsNull)
{
var responses = new Opc.Ua.ISA95.JobControl.V2.ISA95JobResponseProviderObjectTypeClient(
client.Session, endpoints.JobResponseProviderId, client.Telemetry);
var response = await responses.RequestJobResponseByJobOrderIDAsync("job-1", ct);
}
Missing roles are NodeId.Null; Machinery defines no response receiver.
The three-role JobManagementAsync helper returns null when the order receiver
is absent. Otherwise it uses that receiver for the undefined response-receiver
role and as a fallback for a missing response provider. Use the actual
role-specific endpoint when that distinction matters. ISA-95 return codes are
UInt64 bitmaps; only 1 means success, independently of the UA service status.
DownloadResultAsync(machine, resultId, destination, ct) streams through
TemporaryFileTransferClient and leaves the destination open. The ByteString
overload shares that implementation. Advanced callers can use
OpenResultStreamAsync and must asynchronously dispose its UaFileStream.
Conformance matrix
Status key: ✅ implemented and tested · 📄 static NodeSet structure only · 🔲 optional per the published modelling rule · ❌ not shipped.
Conformance units are advertised at runtime, not statically. The series has two kinds of unit and the manager answers them differently:
- a type-exposure unit — "the server exposes this type and all its
supertypes" — is satisfied by loading the model, so it follows
MachineryParts; - every other unit talks about instances, methods or references, and is reported only once a build actually materialised and wired the structure behind it.
A server that builds no machine therefore advertises nothing but
Machinery Find Machines and whatever types its parts loaded.
OPC 40001-1 building blocks
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
Machines folder organized from Objects (Machinery Find Machines) |
✅ | ✅ | MachineryNodeManager |
MachineryModelLoadingTests |
MachineryBuildingBlocks organizer (Machinery Building Block Organization) |
✅ | ✅ | MachineryItemBlocks |
MachineryBuildingBlockTests |
Machine identification (Machinery Machine Identification) |
✅ | ✅ | MachineryBlockBuilders |
MachineBuilderTests |
Component identification and discovery (Machinery Component Identification, Machinery Find Components of Machines) |
✅ | ✅ | same | MachineBuilderTests |
Monitoring add-in (Machinery Monitoring) |
✅ | ✅ | same | MachineBuilderTests |
Monitoring/Health with DI DeviceHealth and DeviceHealthAlarms |
✅ | ✅ | MachineryHealthBuilder |
MachineBuilderTests; MachineryEndToEndTests |
Item state machine, four states / sixteen transitions, no causes (Machinery MachineryItem State) |
✅ | ✅ | MachineryStateMachineTables |
MachineBuilderTests; MachineryStateMachineTests |
Operation-mode state machine (Machinery Operation Mode) |
✅ | ✅ | same | same |
Operation counters (Machinery Operation Counter) |
✅ | ✅ | MachineryBlockBuilders |
MachineBuilderTests; MachineryEndToEndTests |
Lifetime counters (Machinery Lifetime Counter) |
✅ | ✅ | same | MachineBuilderTests |
Machinery equipment (Machinery MachineryEquipment) incl. EquipmentLife |
✅ | ✅ | same | MachineBuilderTests; MachineryEndToEndTests |
Notifications (Machinery Notifications) with a publish seam |
✅ | ✅ | MachineryNotificationsBuilder |
MachineBuilderTests |
| Stacklight over OPC 10000-200 IA | ✅ | 🔲 | MonitoringBuilder |
MachineBuilderTests |
Writable identification (Machinery Machine Identification Writable, Component Identification Mandatory, Component Identification Writable) |
✅ | ✅ opt-in via MachineryIdentificationData.Writable |
MachineryBlockBuilders |
MachineryPartsBuilderTests |
OPC 40001-2 process values
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
ProcessValueType instances over the ProcessValueVariableType subtype (… Base Types, … Analog Object Instances) |
✅ | ✅ | ProcessValueBuilder |
MachineryProcessValueTests; MachineryEndToEndTests |
Setpoint (… Base SetpointType, … Base Process Value Setpoint) |
✅ | ✅ | same | MachineryProcessValueTests |
Limits on the signal (… Limits Base) |
✅ | ✅ | same | MachineryProcessValueTests |
Exclusive limit alarm driven by the value (… Limits Alarm, … Limits Alarm Object) |
✅ | ✅ | MachineryProcessValueAlarm |
MachineryProcessValueTests |
Deviations on the setpoint (… Deviation Base, … Deviation AutoAdjustment, … Deviation Sensitivity) |
✅ | ✅ | ProcessValueBuilder |
MachineryProcessValueTests |
Exclusive deviation alarm against the setpoint (… Deviation Alarm, … Deviation Alarm Object) |
✅ | ✅ | MachineryProcessValueAlarm |
MachineryProcessValueTests |
PercentageValue kept in step with the range (… Percentage Value) |
✅ | ✅ | ProcessValueBuilder |
MachineryProcessValueTests |
Status and AlarmSuppression (… Monitoring, … AlarmSuppression) |
✅ | ✅ | same | MachineryProcessValueTests |
ZeroPointAdjustment method and its event (… Base EventTypes, … ZeroPointAdjustment Events) |
✅ | ✅ | same | MachineryProcessValueTests; MachineryEndToEndTests |
Simulation (PA-DIM AnalogSignalVariable Simulation) |
✅ | ✅ opt-in via WithSimulation() |
ProcessValueBuilder |
MachineryProcessValueTests |
Device object (… Device Object, … Simple Device Info) |
✅ | ✅ opt-in via WithProcessValueDevice() |
MachineBuilder |
MachineryPartsBuilderTests |
OPC 40001-3 job management
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
JobManagement as an AddIn under the organizer, composing ISA-95 Job Control V2 (Machinery Job Management Base, … Minimum String Length) |
✅ | ✅ | JobManagementBuilder |
MachineryPartsBuilderTests; MachineryEndToEndTests |
Job verbs through a machine, including Pause, Resume and RevokeStart and their refusals |
✅ | ✅ | Isa95JobControlV2Binder |
MachineryEndToEndTests |
JobOrderList and JobOrderResponseList kept current, including responses reported while an order runs |
✅ | ✅ | JobManagementBuilder |
MachineryEndToEndTests |
Job results (Machinery Job Management Result Base) |
✅ | ✅ | same | MachineryPartsBuilderTests |
The predefined Planned … / Result … job-order parameters (42 units) |
✅ | ✅ opt-in via WithPredefinedParameters() — the 37 IDs of §9 are recognised and their declared types enforced; anything the series does not predefine still travels untouched |
MachineryJobParameters |
MachineryPartsBuilderTests |
OPC 40001-4 energy
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
Resource folders below Monitoring/Consumption (Machinery Energy Base Structure) |
✅ | ✅ | MachineryEnergyBuilder |
MachineryPartsBuilderTests; MachineryEndToEndTests |
A Main metering point per resource (Machinery Energy Main grouping) |
✅ | ✅ — checked at build time, so a resource folder attached to Consumption past the builder fails the build instead of breaking the unit |
same; check in MachineryBuildScope |
same; MachineryPartsBuilderTests |
INonElectricalEnergyType on a metering point (… Non Electrical Base) |
✅ | ✅ | same | same |
Volume- and mass-flow interfaces (… Volume Flow, … Mass Flow) |
✅ | ✅ | same | MachineryPartsBuilderTests |
Contains from Main to a sub-meter (Machinery Energy Contains) |
✅ | ✅ | same | same; MachineryEndToEndTests |
| Electricity | ✅ | ✅ | same — OPC 40001-4 defers it to OPC 34100's own interfaces, which WithInterface and AddMeasurementValue attach |
MachineryEndToEndTests |
OPC 40001-101 results
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
Result types (Machinery-Result Types) |
✅ | ✅ | MachineryResultManagementBinder |
MachineryPartsBuilderTests |
The five optional methods (… GetLatestResult, … GetResultById, … GetResultsFiltered, Machinery Result AcknowledgeResults) |
✅ | ✅ | same | MachineryPartsBuilderTests |
filter, orderedBy and maxResults of GetResultIdListFiltered (§7.1.3), with OPC 10000-4 NULL semantics |
✅ | ✅ | MachineryResultQuery, MachineryResultFilterEvaluator |
MachineryResultQueryTests; MachineryEndToEndTests |
Mandatory GenerateFileForWrite / CloseAndCommit answering for a read-only result file |
✅ | ✅ | MachineryResultTransferManager |
MachineryResultQueryTests; MachineryEndToEndTests |
| Publishing through an application-supplied store, writable or self-ingesting | — | ✅ | MachineryResult |
MachineryResultQueryTests |
GenerateFileForRead download path with session-bound handles, cap and timeout (… ResultFiles) |
✅ | ✅ | MachineryResultTransferManager |
MachineryPartsBuilderTests; MachineryEndToEndTests |
Result variables in the Results folder (… ResultVariables) |
✅ | ✅ | MachineryResultVariables |
MachineryPartsBuilderTests; MachineryEndToEndTests |
Predefined result metadata (Machinery-Result PredefinedResultMetaData) |
✅ | ✅ opt-in via WithPredefinedResultMetaData() — refused on publish and on the way out of a bound store |
PredefinedResultMetaData |
MachineryPartsBuilderTests |
Result-ready events with a concrete event type (… ResultEvents) |
✅ | ✅ | MachineryResultManagementBinder |
MachineryPartsBuilderTests; MachineryEndToEndTests |
| Stand-alone result server without DI or the machine model, reporting the same units and facets | ✅ | ✅ | MachineryResultNodeManager |
MachineryResultServerTests |
| Durable result store | ❌ not shipped — the storage technology is an open decision; an application plugs its own in through IMachineryResultStore and publishes through it |
— | — | — |
Client and hosting
| Area | Static | Runtime | Source | Tests |
|---|---|---|---|---|
| Discovery, identification, components, building blocks | — | ✅ | MachineryClient |
MachineryClientTests; MachineryEndToEndTests |
| State observation over both state machines | — | ✅ | MachineryClient.StateMachines |
same |
| Process values, zero-point adjustment | — | ✅ | MachineryClient.ProcessValues |
MachineryEndToEndTests |
| Energy resources, metering points and sub-meters | — | ✅ | MachineryClient.Energy |
same |
| Counters, equipment, device health | — | ✅ | MachineryClient.Counters |
same |
| Job control | — | ✅ | MachineryClient.Accessors |
same |
| Job lists and predefined job parameters | — | ✅ | MachineryClient.Jobs, MachineryJobParameters |
MachineryJobParameterClientTests; MachineryEndToEndTests |
| Result download, published result variables, result and zero-point events | — | ✅ | MachineryClient.Events |
same |
Server/client DI wiring (AddMachinery, AddMachineryResults, AddMachineryClient) |
— | ✅ | OpcUaServerMachineryBuilderExtensions |
MachineryHostingTests; MachineryAotTests |
Facet URIs on ServerProfileArray |
— | ✅ | ServerProfiles |
MachineryEndToEndTests reads them back over the wire |
Where the facet URIs come from
Each URI in ServerProfiles
is the published value from the "Profile URIs" table of the matching part, at
the exact model version this repository vendors. The three URI shapes are the
specifications' own and are reproduced verbatim, because conformance tooling
matches a facet URI literally:
| Part | Shape | Example |
|---|---|---|
| 40001-1, -3, -101 | …/UA-Profile/Machinery/…, no trailing slash |
http://opcfoundation.org/UA-Profile/Machinery/Server/State |
| 40001-2 | …/UA/Machinery/ProcessValues/…, with a trailing slash |
http://opcfoundation.org/UA/Machinery/ProcessValues/Server/Base/ |
| 40001-4 | …/UA-Profile/Machinery/Energy/… |
http://opcfoundation.org/UA-Profile/Machinery/Energy/Server/Base |
A facet is advertised only when every conformance unit the specification marks
mandatory for it, and that this library is responsible for, was
materialised and wired. The base-server units each facet also inherits —
address space, view, attribute, method and event subscription — are the stack's
to report and already appear in base.ServerProfiles.
Model sources and identifier tables
Every NodeSet is vendored unmodified from
OPCFoundation/UA-Nodeset (branch
latest). Two files are renamed on the way in, because upstream's names do not
match the assembly they belong to; renaming is safe because
NodeSetToModelDesign.IsNodeSet inspects the document, not the file name.
| Repository path | Upstream path |
|---|---|
src/Opc.Ua.Machinery/Model/Opc.Ua.Machinery.NodeSet2.xml |
Machinery/Opc.Ua.Machinery.NodeSet2.xml |
src/Opc.Ua.Machinery.ProcessValues/Model/Opc.Ua.Machinery.ProcessValues.NodeSet2.xml |
Machinery/ProcessValues/Opc.Ua.Machinery.ProcessValues.NodeSet2.xml |
src/Opc.Ua.Machinery.Jobs/Model/Opc.Ua.Machinery.Jobs.NodeSet2.xml |
Machinery/Jobs/Opc.Ua.Machinery.Jobs.Nodeset2.xml (lower-case s) |
src/Opc.Ua.Machinery.Energy/Model/Opc.Ua.Machinery.Energy.NodeSet2.xml |
Machinery/Energy/Opc.Ua.Machinery.Energy.NodeSet2.xml |
src/Opc.Ua.Machinery.Result/Model/Opc.Ua.Machinery.Result.NodeSet2.xml |
Machinery/Result/Opc.Ua.Machinery_Result.NodeSet2.xml (underscore) |
src/Opc.Ua.IA/Model/Opc.Ua.IA.NodeSet2.xml |
IA/Opc.Ua.IA.NodeSet2.xml |
src/Opc.Ua.ECM/Model/Opc.Ua.ECM.NodeSet2.xml |
ECM/Opc.Ua.ECM.NodeSet2.xml |
src/Opc.Ua.PADIM/Model/Opc.Ua.PADIM.NodeSet2.xml |
PADIM/Opc.Ua.PADIM.NodeSet2.xml |
src/Opc.Ua.PADIM/Model/Opc.Ua.IRDI.NodeSet2.xml |
PADIM/Opc.Ua.IRDI.NodeSet2.xml |
What the identifier table is and is not
Each model carries a Model/*.NodeIds.csv wired up as
ModelSourceGeneratorIdentifierFile. It is not a NodeId source — for a
NodeSet2 input the NodeIds come from the XML
(ModelDesignValidator.LoadDesignFile routes NodeSet2 documents through
NodeSetToModelDesign.Import; only ModelDesign inputs use the CSV fallback).
It is a drift guard: the generator validates every row against the imported
symbols and fails the build with MODELGEN022…MODELGEN029 when the vendored
model and the pinned mapping disagree. That is how a silently dropped type gets
caught instead of quietly disappearing from the generated API.
Model/*.Upstream.NodeIds.csv is the OPC Foundation's publication unmodified
and is deliberately kept out of <AdditionalFiles>, so the two can be diffed to
compare the published and derived mappings, following the convention used by
src/Opc.Ua.ISA95.
Why the published tables need deriving
The published tables carry the UA-ModelCompiler's symbolic names, which differ
from the ones this repository's generator derives. Three differences occur; all
three are handled by
tools/nodesets/derive-identifier-table.py,
which reimplements NodeSetToModelDesign.ImportSymbolicName / BuildSymbolicId:
| Published | Derived | Why |
|---|---|---|
Server_Namespaces_http___…_ |
http___…_ |
the publication qualifies the namespace-metadata object with its server path |
X_ControlChannel |
X_ControlChannel_Placeholder |
a <Placeholder> BrowseName maps to Name_Placeholder |
DefaultBinary |
RGBWDataType_Encoding_DefaultBinary |
encoding nodes are qualified with the data type they encode |
Two publications also deviate in shape rather than in naming, and the script
reads both: ECM publishes its table as Opc.Ua.ECM.NodeSet2.csv rather than
*.NodeIds.csv, and PADIM publishes a tab-separated table with an
ID / Browsename / Node Class header — identifier first, and BrowseNames rather
than symbolic names. IRDI has no published table at all and therefore
carries no drift guard.
The numeric ids and node classes agree with the NodeSets in all nine models. The vendored NodeSets therefore require no normative corrections.
Cross-assembly generator behavior
Models consumed through referenced assemblies carry their type and member metadata in dependency payloads. The generator preserves the following relationships when composing Machinery with DI, ECM and PA-DIM.
VariableType data type restrictions. DependencyNode carries a
VariableType's DataType and ValueRank alongside its base type, numeric id,
abstractness, fields and children. Consumers use these restrictions when
resolving variables such as OPC 40001-1's EquipmentLife and
<LifetimeVariable>, both typed by DI's LifetimeVariableType.
An optional node flag identifies the restriction metadata; payloads without
that flag remain readable. If required type metadata cannot be resolved,
GetNodeStateClassName reports the variable and its type in the error message.
Method-state and declaration identities. When a dependency child carries
both identities, the consumer links the declaration to its method-state node.
ResolveMethodStateIdentity follows that relationship to select the
producer's generated method-state class. This supports inherited method
re-declarations, including the DI LockingServices methods on OPC 34100 ECM.
Inherited reference types and browse-name namespaces. DependencyChild
carries BrowseNameNamespace, ReferenceTypeName and
ReferenceTypeNamespace. Directly instantiated derived types and nested
instances use the same inherited attributes. For example, the OPC 40001-2
members inherited from PA-DIM have these attributes:
| Member | Reference type | Browse-name namespace |
|---|---|---|
ProcessValueType.SignalTag |
HasProperty |
PA-DIM |
ProcessValueVariableType.EngineeringUnits |
HasProperty |
OPC UA (namespace 0) |
The producer records a browse namespace only when it differs from the
declaring model and a reference type only when it differs from the member
kind's default. Per-child flag bits identify the optional metadata.
MaterialiseDependencyChild assigns the carried reference type when present,
or the same kind default that ImportInstance applies to locally declared
instances. Payloads without the optional metadata use those defaults.
ApplyDefaultSignalTag supplies the OPC 30081 default value for the mandatory
tag. The opc.tcp end-to-end tests exercise filtered browsing, and
MachineryProcessValueTests.TheSignalKeepsThePadimBrowseNameAndTheNarrowerTypeAsync
checks the inherited attributes.
See also
- Machinery samples — a simulated press that exercises all five parts, and a client that walks it
- Device Integration (DI) developer guide
- ISA-95 developer guide — OPC 40001-3 sits on Job Control V2
- Cross-assembly model dependencies
- Robotics developer guide — shares