# Description _Describe the changes here to communicate to the maintainers why they should accept this pull request. By default - this will become the Commit message after merging and thus define history._ Add provider-backed MachineTool, bundled WMTP, GMS and CranesHoists companions using the existing Machinery/MachineVision fluent, DI and typed-client approach. **The PR is open/non-draft by user choice. Current head `ecc4a7d6ca3e8004cf28ab54da605da302d026bf` is mergeable and has 108 successful checks, six intentionally skipped checks, zero failures and zero pending checks. All five primary workflows completed successfully at that exact head.** | Family | Released specification/model | Packaging | | --- | --- | --- | | MachineTool | OPC 40501-1, 1.02.0 | Model, Server, Client and MCP; normal root versions | | WMTP | OPC 40505, 1.0.0 | Bundled in MachineTool; distinct CLR/wire namespace and independent WMTP-only hosting | | GMS | OPC 40210 reference 1.0.1, normative model 1.0.0 | Model, Server, Client and MCP; normal root versions | | CranesHoists | OPC 40020-1, 1.00 | Model, Server, Client and MCP; all four plus Debug variants forced preview | There are **12 new packable projects**. No separate WMTP package/profile/guide, root version bump, tag, release or package publication is included. Mandatory instance structure is the default; selected optional features require explicit providers. The implementation reuses Machinery results/jobs/files/ProcessValues and Robotics topology, including retained MachineTool Production, defined GMS jobs/parts, modern ISA95/Machinery jobs, shared-owner hosting and isolated instances alongside MachineVision. Runtime and integration fixes preserve raw quality/timestamps, coherent acquisition, namespace ownership, accepted-configuration state, borrowed-resource lifetime, session/node/file cleanup, terminal-value publication, event propagation and endpoint-aware capability publication. Firmware/licence transfer means provider acceptance, not installation/activation. Cancellation does not silently abort another caller's operation. The later upstream MCP expansion is integrated without losing either family set or its default-off privileged/live execution policy. ### Conformance and scope Canonical model inputs are pinned to UA-Nodeset revision `96a08945425d0295edb3607d2a38f6841ef44046`. **GMS upstream exception:** [Annex A.1](https://reference.opcfoundation.org/specs/OPC-40210/annex-a) makes the released NodeSet normative, but §12.3.2.7 requires undefined `GMS_ProductionStatisticsType`. Inherited statistics and defined jobs/parts are implemented without inventing a standard type/NodeId; the complete GMS Production facet is withheld. The requirement ledger records **102 positively evidenced CU rows, 96 directly negative-tested rows and six explicit negative-evidence limitations**. All 648 test-class/name/TRX links were independently resolved to passing cases. The six limitations concern Stacklight, retained legacy PowerOnDuration, Machinery PowerOnDuration, WorkingUnit, Obligation and MaintenanceMode. They are not claims that every invalid-input or hardware-control behavior was tested. The undefined GMS requirement is outside the 102 defined CUs. No external certification claim is made. Retained baseline complete-assembly line coverage, with generated code retained and no source exclusions: | Family | Model | Server | Client | | --- | ---: | ---: | ---: | | MachineTool/WMTP | 83.80% | 91.98% | 84.74% | | GMS | 95.51% | 90.63% | 88.38% | | CranesHoists | 92.76% | 94.45% | 92.24% | These nine measurements predate the later focused review fixes and merges; they are not relabelled as new `ecc4a7d6c` percentages. The current head's separate CI code-coverage check succeeded. No new exclusions or threshold relaxations were introduced. ## Related Issues - Fixes [#4764](https://github.com/OPCFoundation/UA-.NETStandard/issues/4764), the implementation/design and acceptance tracker. ## Checklist _Put an `x` in the boxes that apply. You can complete these step by step after opening the PR._ - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [ ] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [x] I have addressed **all** PR feedback received.
348 lines
18 KiB
C#
348 lines
18 KiB
C#
/* ========================================================================
|
|
* Copyright (c) 2005-2026 The OPC Foundation, Inc. All rights reserved.
|
|
*
|
|
* OPC Foundation MIT License 1.00
|
|
*
|
|
* Permission is hereby granted, free of charge, to any person
|
|
* obtaining a copy of this software and associated documentation
|
|
* files (the "Software"), to deal in the Software without
|
|
* restriction, including without limitation the rights to use,
|
|
* copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
* copies of the Software, and to permit persons to whom the
|
|
* Software is furnished to do so, subject to the following
|
|
* conditions:
|
|
*
|
|
* The above copyright notice and this permission notice shall be
|
|
* included in all copies or substantial portions of the Software.
|
|
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
|
|
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
|
|
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
|
|
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
|
|
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
|
|
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
|
|
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
|
|
* OTHER DEALINGS IN THE SOFTWARE.
|
|
*
|
|
* The complete license agreement can be found here:
|
|
* http://opcfoundation.org/License/MIT/1.00/
|
|
* ======================================================================*/
|
|
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Text;
|
|
using System.Threading;
|
|
using System.Threading.Tasks;
|
|
using Opc.Ua;
|
|
using Opc.Ua.Client.FileSystem;
|
|
using Opc.Ua.MachineTool;
|
|
using Opc.Ua.MachineTool.Client;
|
|
using Opc.Ua.MachineTool.WMTP;
|
|
using TypedClient = Opc.Ua.MachineTool.Client.MachineToolClient;
|
|
using V2 = Opc.Ua.ISA95.JobControl.V2;
|
|
|
|
namespace MachineToolSample.Client
|
|
{
|
|
/// <summary>
|
|
/// Demonstrates generated proxies and bounded typed workflows without reimplementing OPC UA services.
|
|
/// </summary>
|
|
internal static class DemoReader
|
|
{
|
|
/// <summary>
|
|
/// Discovers actual identities, reads selected instances, then performs at most one bounded observation.
|
|
/// </summary>
|
|
internal static async Task RunAsync(TypedClient client, ClientOptions options, CancellationToken ct)
|
|
{
|
|
ArrayOf<MachineToolDeviceEntry> devices = await client.DiscoverAsync(options.MaximumDevices, ct)
|
|
.ConfigureAwait(false);
|
|
Console.WriteLine($"DISCOVERED count={devices.Count} models={client.AvailableParts}");
|
|
var selected = new List<MachineToolDeviceEntry>();
|
|
for (int index = 0; index < devices.Count; index++)
|
|
{
|
|
MachineToolDeviceEntry entry = devices[index];
|
|
Console.WriteLine($"DEVICE name={entry.BrowseName} id={entry.NodeId} kind={entry.Kind}");
|
|
if (options.Target == null || entry.BrowseName.Name == options.Target)
|
|
{
|
|
selected.Add(entry);
|
|
}
|
|
}
|
|
if (options.Target != null && selected.Count != 1)
|
|
{
|
|
throw new ArgumentException("The explicit target must identify exactly one discovered instance.");
|
|
}
|
|
var variables = new List<NodeId>();
|
|
foreach (MachineToolDeviceEntry entry in selected)
|
|
{
|
|
if (entry.Kind == MachineToolDeviceKind.MachineTool)
|
|
{
|
|
await ReadMachineAsync(client, entry, options, ct).ConfigureAwait(false);
|
|
}
|
|
else
|
|
{
|
|
await ReadPeripheralAsync(client, entry, options, variables, ct).ConfigureAwait(false);
|
|
}
|
|
}
|
|
if (options.Seconds > 0 && selected.Count > 0)
|
|
{
|
|
var settings = new MachineToolObservationOptions
|
|
{
|
|
Window = TimeSpan.FromSeconds(options.Seconds),
|
|
MaximumNotifications = options.Count
|
|
};
|
|
MachineToolDeviceEntry? machine = selected.Find(
|
|
entry => entry.Kind == MachineToolDeviceKind.MachineTool);
|
|
MachineToolDataObservation? observation = machine != null
|
|
? await client.ObserveDataAsync(machine.NodeId, settings, ct).ConfigureAwait(false)
|
|
: variables.Count != 0
|
|
? await client.ObserveValuesAsync(variables.ToArrayOf(), settings, ct).ConfigureAwait(false)
|
|
: null;
|
|
if (observation != null)
|
|
{
|
|
Console.WriteLine($"OBSERVED count={observation.Changes.Count} limit={observation.LimitReached} " +
|
|
$"dropped={observation.DroppedNotifications}");
|
|
for (int index = 0; index < observation.Changes.Count; index++)
|
|
{
|
|
Print(client, observation.Changes[index].NodeId.ToString(), observation.Changes[index].Value);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
Console.WriteLine(
|
|
"OBSERVATION_ABSENT: selected peripheral has no configured measurement variables.");
|
|
}
|
|
}
|
|
}
|
|
|
|
private static async Task ReadMachineAsync(
|
|
TypedClient client, MachineToolDeviceEntry entry, ClientOptions options, CancellationToken ct)
|
|
{
|
|
if (options.Command is not ("none" or "job-store-start"))
|
|
{
|
|
throw new ArgumentException("This command requires a wireless peripheral, not a machine.");
|
|
}
|
|
MachineToolReadSnapshot snapshot = await client.ReadSnapshotAsync(entry.NodeId, ct).ConfigureAwait(false);
|
|
Print(client, "OperationMode", snapshot.OperationMode);
|
|
Print(client, "ActiveProgram", snapshot.ActiveProgramName);
|
|
MachineToolCapabilityReadSnapshot capabilities = await client.GetCapabilitiesAsync(entry.NodeId, ct)
|
|
.ConfigureAwait(false);
|
|
Console.WriteLine($"CAPABILITIES declared={capabilities.DeclarationAvailable}");
|
|
MachineToolEquipmentReadSnapshot equipment = await client.ReadEquipmentAsync(
|
|
entry.NodeId, 32, 128, ct).ConfigureAwait(false);
|
|
MachineToolPrognosisReadSnapshot prognoses = await client.ReadPrognosesAsync(entry.NodeId, 32, ct)
|
|
.ConfigureAwait(false);
|
|
MachineToolProductionReadSnapshot production = await client.ReadProductionAsync(entry.NodeId,
|
|
new MachineToolProductionReadOptions { MaximumElements = 128, MaximumReferences = 1024 }, ct)
|
|
.ConfigureAwait(false);
|
|
Console.WriteLine($"MACHINE tools={equipment.Tools.Count} prognoses={prognoses.Entries.Count} " +
|
|
$"jobs={production.Jobs.Count}");
|
|
if (options.ReadFiles)
|
|
{
|
|
FileDirectoryTypeClient root =
|
|
await client.GetWorkMastersAsync(entry.NodeId, ct).ConfigureAwait(false) ??
|
|
throw new ServiceResultException(StatusCodes.BadNotSupported, "WorkMasters is not configured.");
|
|
var files = new FileSystemClient(client.Session, root.ObjectId,
|
|
new FileSystemClientOptions { MaxBufferedReadSize = 4096 });
|
|
string path = FormattableString.Invariant($"{root.ObjectId.NamespaceIndex}:{DemoContract.ProgramName}");
|
|
byte[] contents = await files.ReadAllBytesAsync(path, ct).ConfigureAwait(false);
|
|
if (Encoding.UTF8.GetString(contents) != DemoContract.ProgramContents)
|
|
{
|
|
throw new InvalidOperationException("The remote program is not the documented simulation content.");
|
|
}
|
|
Console.WriteLine($"FILE_COPIED bytes={contents.Length}; read-only simulation data, never executed.");
|
|
}
|
|
if (options.Command == "job-store-start")
|
|
{
|
|
Opc.Ua.Machinery.Jobs.JobManagementTypeClient management =
|
|
await client.GetJobManagementAsync(entry.NodeId, ct).ConfigureAwait(false) ??
|
|
throw new ServiceResultException(StatusCodes.BadNotSupported, "Machinery Jobs is not configured.");
|
|
V2.ISA95JobOrderReceiverObjectTypeClient receiver =
|
|
await management.GetJobOrderControlAsync(client.Telemetry, ct).ConfigureAwait(false) ??
|
|
throw new ServiceResultException(StatusCodes.BadConfigurationError, "JobOrderControl is missing.");
|
|
ulong result = await receiver.StoreAndStartAsync(new V2.ISA95JobOrderDataType
|
|
{
|
|
EncodingMask = (uint)V2.ISA95JobOrderDataTypeFields.WorkMasterID,
|
|
JobOrderID = DemoContract.JobOrderId,
|
|
WorkMasterID = [new V2.ISA95WorkMasterDataType { ID = DemoContract.WorkMasterId }]
|
|
}, [new LocalizedText("Explicitly consented simulated order.")], ct).ConfigureAwait(false);
|
|
if (result != 1)
|
|
{
|
|
throw new ServiceResultException(StatusCodes.BadInvalidState,
|
|
FormattableString.Invariant($"ISA95 request refused with ReturnStatus {result}."));
|
|
}
|
|
Console.WriteLine("JOB_ACCEPTED: StoreAndStart accepted; this does not assert CNC execution.");
|
|
}
|
|
}
|
|
|
|
private static async Task ReadPeripheralAsync(
|
|
TypedClient owner, MachineToolDeviceEntry entry, ClientOptions options, List<NodeId> variables,
|
|
CancellationToken ct)
|
|
{
|
|
if (options.ReadFiles || options.Command == "job-store-start")
|
|
{
|
|
throw new ArgumentException("The selected workflow requires a machine, not a wireless peripheral.");
|
|
}
|
|
WmtpPeripheralClient client = owner.GetWirelessPeripheral(entry.NodeId);
|
|
WmtpPeripheralSnapshot snapshot = await client.ReadSnapshotAsync(ct).ConfigureAwait(false);
|
|
Print(owner, "SerialNumber", snapshot.SerialNumber);
|
|
Print(owner, "Battery", snapshot.Battery);
|
|
Print(owner, "CalibrationMode", snapshot.CalibrationMode);
|
|
ArrayOf<WmtpMeasurementReading> sensors = await client.ReadMeasurementsAsync(32, ct).ConfigureAwait(false);
|
|
for (int index = 0; index < sensors.Count; index++)
|
|
{
|
|
WmtpMeasurementReading sensor = sensors[index];
|
|
Print(owner, sensor.BrowseName.ToString(), sensor.Sample);
|
|
variables.Add(sensor.ValueNodeId);
|
|
if (variables.Count > 256)
|
|
{
|
|
throw new ServiceResultException(StatusCodes.BadEncodingLimitsExceeded,
|
|
"The complete selected measurement inventory exceeds the observation bound.");
|
|
}
|
|
}
|
|
if (await client.Proxy.GetWMTPWorkCycleDataAsync(owner.Telemetry, ct).ConfigureAwait(false) != null)
|
|
{
|
|
await ReadRecordsAsync(await client.GetWorkRecordsAsync(ct).ConfigureAwait(false), "work", ct)
|
|
.ConfigureAwait(false);
|
|
}
|
|
if (await client.Proxy.GetWMTPServiceCycleDataAsync(owner.Telemetry, ct).ConfigureAwait(false) != null)
|
|
{
|
|
await ReadRecordsAsync(await client.GetServiceRecordsAsync(ct).ConfigureAwait(false), "service", ct)
|
|
.ConfigureAwait(false);
|
|
}
|
|
await RequestAsync(client, sensors, options, ct).ConfigureAwait(false);
|
|
}
|
|
|
|
private static async Task ReadRecordsAsync(WmtpRecordClient records, string dataset, CancellationToken ct)
|
|
{
|
|
var all = new WmtpRecordQuery();
|
|
uint before = await records.CountAsync(all, ct).ConfigureAwait(false);
|
|
ArrayOf<WMTPOutputDataType> copy = await records.ReadAsync(all, 16, ct).ConfigureAwait(false);
|
|
uint after = await records.CountAsync(all, ct).ConfigureAwait(false);
|
|
if (copy.Count != before || after != before)
|
|
{
|
|
throw new InvalidOperationException("The sample dataset changed during its nonconsuming report.");
|
|
}
|
|
Console.WriteLine($"RECORDS dataset={dataset} count={copy.Count} retained={after}");
|
|
}
|
|
|
|
private static async Task RequestAsync(
|
|
WmtpPeripheralClient client, ArrayOf<WmtpMeasurementReading> sensors,
|
|
ClientOptions options, CancellationToken ct)
|
|
{
|
|
switch (options.Command)
|
|
{
|
|
case "none":
|
|
return;
|
|
case "configure":
|
|
await ConfigureAsync(client, sensors, options, ct).ConfigureAwait(false);
|
|
break;
|
|
case "calibrate-on":
|
|
case "calibrate-off":
|
|
await client.SetCalibrationAsync(options.Command == "calibrate-on", ct).ConfigureAwait(false);
|
|
break;
|
|
case "set-time":
|
|
await client.SetDeviceTimeAsync(TimeProvider.System.GetUtcNow(),
|
|
new TimeZoneDataType { Offset = 0, DaylightSavingInOffset = false }, ct).ConfigureAwait(false);
|
|
break;
|
|
case "delete-work":
|
|
WmtpRecordClient deleting = await client.GetWorkRecordsAsync(ct).ConfigureAwait(false);
|
|
await deleting.DeleteAsync(new WmtpRecordQuery
|
|
{
|
|
Selection = WmtpRecordSelection.Index,
|
|
FromIndex = (uint)options.DeleteIndex!.Value,
|
|
ToIndex = (uint)options.DeleteIndex.Value
|
|
}, ct).ConfigureAwait(false);
|
|
break;
|
|
case "abort-work":
|
|
WmtpRecordClient aborting = await client.GetWorkRecordsAsync(ct).ConfigureAwait(false);
|
|
await aborting.AbortAsync(ct).ConfigureAwait(false);
|
|
break;
|
|
case "firmware":
|
|
case "license":
|
|
byte[] bytes = new byte[options.TransferBytes!.Value];
|
|
bytes.AsSpan().Fill((byte)'D');
|
|
await client.TransferAsync(options.Command == "firmware"
|
|
? WmtpTransferKind.Firmware : WmtpTransferKind.License, ByteString.From(bytes),
|
|
cancellationToken: ct)
|
|
.ConfigureAwait(false);
|
|
Console.WriteLine("TRANSFER_ACCEPTED: provider received demonstration bytes; nothing installed.");
|
|
break;
|
|
default:
|
|
throw new ArgumentException("Unsupported wireless command.");
|
|
}
|
|
Console.WriteLine($"REQUEST_ACCEPTED command={options.Command} target={options.Target}");
|
|
}
|
|
|
|
private static async Task ConfigureAsync(
|
|
WmtpPeripheralClient client, ArrayOf<WmtpMeasurementReading> sensors,
|
|
ClientOptions options, CancellationToken ct)
|
|
{
|
|
NodeId selected = default;
|
|
for (int index = 0; index < sensors.Count; index++)
|
|
{
|
|
if (sensors[index].BrowseName.Name == options.Sensor)
|
|
{
|
|
if (!selected.IsNull)
|
|
{
|
|
throw new ArgumentException("The sensor name is ambiguous.");
|
|
}
|
|
selected = sensors[index].NodeId;
|
|
}
|
|
}
|
|
if (selected.IsNull)
|
|
{
|
|
throw new ArgumentException("The selected sensor is not present.");
|
|
}
|
|
WMTPMeasurementTypeClient proxy = client.GetMeasurementProxy(selected);
|
|
await proxy.SetTriggerSettingsAsync(options.TriggerMilliseconds!.Value, ct).ConfigureAwait(false);
|
|
if (options.ProveRefusal)
|
|
{
|
|
bool refused = false;
|
|
try
|
|
{
|
|
await proxy.SetTriggerSettingsAsync(options.TriggerMilliseconds.Value + 1, ct)
|
|
.ConfigureAwait(false);
|
|
}
|
|
catch (ServiceResultException error) when (error.StatusCode == StatusCodes.BadResourceUnavailable)
|
|
{
|
|
refused = true;
|
|
}
|
|
if (!refused)
|
|
{
|
|
throw new InvalidOperationException("The second simulated configuration was not refused.");
|
|
}
|
|
ArrayOf<WmtpMeasurementReading> after =
|
|
await client.ReadMeasurementsAsync(32, ct).ConfigureAwait(false);
|
|
bool retained = false;
|
|
for (int index = 0; index < after.Count; index++)
|
|
{
|
|
if (after[index].NodeId == selected)
|
|
{
|
|
if (!after[index].TriggerSettings.WrappedValue.TryGetValue(out uint trigger) ||
|
|
trigger != options.TriggerMilliseconds.Value)
|
|
{
|
|
throw new InvalidOperationException("Refusal changed the previously accepted trigger.");
|
|
}
|
|
retained = true;
|
|
}
|
|
}
|
|
if (!retained)
|
|
{
|
|
throw new InvalidOperationException("The configured sensor disappeared before readback.");
|
|
}
|
|
Console.WriteLine("REFUSAL_CONFIRMED: second request rejected; accepted trigger retained.");
|
|
}
|
|
}
|
|
|
|
private static void Print(TypedClient client, string label, in DataValue value)
|
|
{
|
|
if (value.IsNull)
|
|
{
|
|
Console.WriteLine($"{label}: ABSENT");
|
|
return;
|
|
}
|
|
using var encoder = new JsonEncoder(client.Session.MessageContext);
|
|
encoder.WriteDataValue("DataValue", value);
|
|