Files
Marc Schier 0374e19121 Add MachineTool, WMTP, GMS and CranesHoists companions (#4765)
# Description

_Describe the changes here to communicate to the maintainers why they
should accept this pull request. By default - this will become the
Commit message after merging and thus define history._

Add provider-backed MachineTool, bundled WMTP, GMS and CranesHoists
companions using the existing Machinery/MachineVision fluent, DI and
typed-client approach. **The PR is open/non-draft by user choice.
Current head `ecc4a7d6ca3e8004cf28ab54da605da302d026bf` is mergeable and
has 108 successful checks, six intentionally skipped checks, zero
failures and zero pending checks. All five primary workflows completed
successfully at that exact head.**

| Family | Released specification/model | Packaging |
| --- | --- | --- |
| MachineTool | OPC 40501-1, 1.02.0 | Model, Server, Client and MCP;
normal root versions |
| WMTP | OPC 40505, 1.0.0 | Bundled in MachineTool; distinct CLR/wire
namespace and independent WMTP-only hosting |
| GMS | OPC 40210 reference 1.0.1, normative model 1.0.0 | Model,
Server, Client and MCP; normal root versions |
| CranesHoists | OPC 40020-1, 1.00 | Model, Server, Client and MCP; all
four plus Debug variants forced preview |

There are **12 new packable projects**. No separate WMTP
package/profile/guide, root version bump, tag, release or package
publication is included. Mandatory instance structure is the default;
selected optional features require explicit providers. The
implementation reuses Machinery results/jobs/files/ProcessValues and
Robotics topology, including retained MachineTool Production, defined
GMS jobs/parts, modern ISA95/Machinery jobs, shared-owner hosting and
isolated instances alongside MachineVision.

Runtime and integration fixes preserve raw quality/timestamps, coherent
acquisition, namespace ownership, accepted-configuration state,
borrowed-resource lifetime, session/node/file cleanup, terminal-value
publication, event propagation and endpoint-aware capability
publication. Firmware/licence transfer means provider acceptance, not
installation/activation. Cancellation does not silently abort another
caller's operation. The later upstream MCP expansion is integrated
without losing either family set or its default-off privileged/live
execution policy.

### Conformance and scope

Canonical model inputs are pinned to UA-Nodeset revision
`96a08945425d0295edb3607d2a38f6841ef44046`.

**GMS upstream exception:** [Annex
A.1](https://reference.opcfoundation.org/specs/OPC-40210/annex-a) makes
the released NodeSet normative, but §12.3.2.7 requires undefined
`GMS_ProductionStatisticsType`. Inherited statistics and defined
jobs/parts are implemented without inventing a standard type/NodeId; the
complete GMS Production facet is withheld.

The requirement ledger records **102 positively evidenced CU rows, 96
directly negative-tested rows and six explicit negative-evidence
limitations**. All 648 test-class/name/TRX links were independently
resolved to passing cases. The six limitations concern Stacklight,
retained legacy PowerOnDuration, Machinery PowerOnDuration, WorkingUnit,
Obligation and MaintenanceMode. They are not claims that every
invalid-input or hardware-control behavior was tested. The undefined GMS
requirement is outside the 102 defined CUs. No external certification
claim is made.

Retained baseline complete-assembly line coverage, with generated code
retained and no source exclusions:

| Family | Model | Server | Client |
| --- | ---: | ---: | ---: |
| MachineTool/WMTP | 83.80% | 91.98% | 84.74% |
| GMS | 95.51% | 90.63% | 88.38% |
| CranesHoists | 92.76% | 94.45% | 92.24% |

These nine measurements predate the later focused review fixes and
merges; they are not relabelled as new `ecc4a7d6c` percentages. The
current head's separate CI code-coverage check succeeded. No new
exclusions or threshold relaxations were introduced.

## Related Issues

- Fixes
[#4764](https://github.com/OPCFoundation/UA-.NETStandard/issues/4764),
the implementation/design and acceptance tracker.

## Checklist

_Put an `x` in the boxes that apply. You can complete these step by step
after opening the PR._

- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [ ] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [x] I have addressed **all** PR feedback received.
2026-10-15 15:15:46 +02:00

4.9 KiB

MachineTool and wireless-peripheral samples

These applications use the released typed MachineTool/WMTP runtime and clients. Their providers are explicitly simulated: no CNC instructions, Bluetooth pairing, radio driver, firmware installation or licence activation is performed.

Build both applications before starting the bounded server:

dotnet build samples\MachineTool\MachineToolServer\MachineToolServer.csproj -f net10.0
dotnet build samples\MachineTool\MachineToolClient\MachineToolClient.csproj -f net10.0

Run a secure, isolated workcell

In one terminal:

dotnet run --no-build --project samples\MachineTool\MachineToolServer -f net10.0 -- --mode mixed --advanced --instances 2 --seconds 120 --demo-trust --allow-commands --simulate-job Machine1

After its actual READY message, in another terminal:

dotnet run --no-build --project samples\MachineTool\MachineToolClient -f net10.0 -- --demo-trust

Default endpoint: opc.tcp://127.0.0.1:62558/MachineToolServer. --port 0 chooses an available port; pass the reported URL to the client's --endpoint. The server always binds loopback. --demo-trust is an explicit local-only certificate exception; SignAndEncrypt/Basic256Sha256 remain required. Without it, administer separate client/server trust stores with --pki. Never deploy demo trust as production authorization.

--mode machine, wmtp and mixed select independent model closures. Mandatory-only is the default; --advanced selects production/jobs/files and all eight wireless measurement kinds, metadata and independent work/service records. --instances 1..4 creates independent providers/stores for each selected family.

The client discovers native identities, reads raw values/capabilities and complete bounded records, then makes one bounded observation. It preserves UA quality and acquisition time. Reports copy records rather than consuming them. A WMTP-only endpoint never fabricates a MachineTool.

Explicit commands

Every client mutation requires --target and --consent. The server separately requires --advanced --demo-trust --allow-commands; --refuse-commands provides a deterministic refusal scenario.

# Read the non-executable WorkMasters file and submit the declared ISA95 order.
dotnet run --no-build --project samples\MachineTool\MachineToolClient -f net10.0 -- --demo-trust --target Machine1 --read-files --command job-store-start --consent

# Accept a UInt32 trigger setting, then explicitly prove a second request is refused.
dotnet run --no-build --project samples\MachineTool\MachineToolClient -f net10.0 -- --demo-trust --target Peripheral1 --command configure --sensor Temperature --trigger-ms 2000 --consent --prove-refusal

# Transfer generated, nonsecret demonstration bytes. Acceptance is not installation.
dotnet run --no-build --project samples\MachineTool\MachineToolClient -f net10.0 -- --demo-trust --target Peripheral1 --command firmware --transfer-bytes 32 --consent

Use --help for calibration, explicit UTC time, selected record deletion, licence transfer and explicit abort. Local timeout/cancellation never sends AbortOperation or retries an uncertain write.

Each peripheral accepts at most one simulated configuration, calibration, time setting and transfer of each kind; later requests are refused. A refused configuration retains the previously accepted trigger/delta. The separately selected server --simulate-job Machine1 supplies explicit execution/part observations after StoreAndStart. Job acceptance alone never means a machine executed anything.

Lifetimes and bounds

Server windows are 1-600 seconds. Client work has a 90-second deadline; observation is 0-20 seconds and 1-100 notifications. Discovery, sensors, files, record reports and transfer bytes have explicit ceilings. Oversize data fails, not silently truncated success. --freeze-measurements demonstrates real stale quality on advanced wireless observations.

--cancel-after-ms exercises bounded cancellation. Exit codes are 0 completed, 1 error/refusal, and 2 cancelled. Natural server shutdown joins acquisition, drains runtimes, releases providers and deletes only its generated temporary read-only program folders. PKI remains available for administration. Clients close call-owned subscriptions/files and their managed session.

Frameworks and NativeAOT

Both projects support net48, net8.0, net9.0 and net10.0. NativeAOT is selected only on the application projects for net10.0:

dotnet publish samples\MachineTool\MachineToolServer -c Release -f net10.0 -r win-x64 --self-contained true
dotnet publish samples\MachineTool\MachineToolClient -c Release -f net10.0 -r win-x64 --self-contained true

Run the published executables with the same CLI arguments; publishing alone does not prove native behavior. See the developer guide for provider contracts and CompanionSuite for all families on one DI/Machinery owner.