# Description Implement the released [OPC 40100-1](https://reference.opcfoundation.org/specs/OPC-40100-1) and [OPC 40100-2](https://reference.opcfoundation.org/specs/OPC-40100-2) specifications with generated models, provider-backed runtimes, typed clients, MCP workflows, and DI/Machinery integration. - **Part 1 stays in `Opc.Ua.Vision`** and its client/server packages alongside the distinct Perception model. Provide control/acquisition state machines, jobs and synchronized steps, recipe/product/configuration/result management, file transfers, diagnostics, events, and conditions. - **Part 2 is in `Opc.Ua.MachineVision`, `.Client`, and `.Server`.** Provide asset categories, identification, image-handling aspects, health/maintenance data, topology, and transactional updates. The base Vision assemblies do not reference these optional packages; the Part 2 wire model does not depend on Part 1. - Preserve the release-pinned model bytes, wire namespaces and NodeIds. Perception types are in `Opc.Ua.Vision.Perception`; the AMCM generated namespace remains `Opc.Ua.Vision.MachineVision.AMCM`, and asset client/server extension namespaces remain `Opc.Ua.Vision.Client` and `Opc.Ua.Vision.Server`. - Use `AddOpcUaMachineVision` and `AddOpcUaMachineVisionAMCM` for model loading and factory registration. Each has node-collection, encodeable-factory-builder and node-state-factory-builder overloads. These short entry points delegate to the generated implementations; existing namespace-derived generated names remain available for compatibility. - Support multiple independent named systems/assets under one namespace-owning manager. Reuse injectable providers, file binding, bounded memory stores, optional transactional `IFileSystemProvider` persistence, state machines, telemetry and conformance infrastructure. - Keep one `docs/Vision.md` guide, titled `Machine Vision (OPC 40100-1 and OPC 40100-2)`, and one `Opc.Ua.Mcp.Vision` package. Include deterministic server/client samples. - Expose 17 Machine Vision MCP tools, including capabilities/status, bounded relationships and observation, complete small-file uploads/downloads, management, explicit control, conditions, and chunked transfers. Catalogue counts: 39 Vision-specific, 43 with connection tools, 81 Vision+Robotics, 155 Full. Every Machine Vision wire parameter has a schema description. **Compatibility and limits:** `AddVision()` remains Perception-only unless released parts are selected. Standalone Part 2 uses `AddVision().AddMachineVision()`; Machinery composition uses `AddVisionToMachinery()`. Existing tool defaults and command signatures are preserved. Observation owns and cleans up its subscription: 5 seconds/50 notifications by default, capped at 60 seconds/100 notifications. Complete-file tools are capped at 1 MiB; larger files use chunked transfers. Domain Error values remain distinct from UA service failures. **Versioning:** the seven Vision/MachineVision/MCP packages and their Debug variants follow the repository root version instead of being forced to preview. Vision.OpenUsd and its descendants remain preview-only. Development builds still inherit the root prerelease version. No release version, tag, release branch, publication policy, or feed promotion is changed. **Review actions:** all fourteen review threads have action/evidence replies and are resolved. Changes include the unified guide, Perception namespace, separate Part 2 packages and final naming, multi-system ownership explanation, interrupted-write cleanup, observer failure isolation, complete MCP parameter descriptions, and explicit package inventory. The preview-layout migration topic and the requested ReleaseProcess caveat were removed. The test Publish collector now retries recognized transient failures within one cancellation budget and propagates other exceptions. Commit69b1f5db9applies the requested short loader names and renames standalone hosting to `AddMachineVision`, with callers, tests and documentation updated. The intervening master merge is preserved. ### Verification **Latest API naming changes, verified locally:** | Scope | Result | | --- | --- | | Full Vision suite, net10 | 572 passed, 1 existing skip, 0 failed | | Full Vision suite, net48 | 515 passed, 0 skipped, 0 failed | | Final loader/hosting cases after cross-TFM null-guard adjustment | 9 passed, 0 failed, 0 skipped | | Machine Vision MCP and profile cases | 198 passed, 0 failed, 0 skipped | | Main and MCP AOT test-project compilation | Both built with 0 warnings/errors | | MCP AOT companion, managed execution | 5 passed, 0 failed, 0 skipped; not claimed as native execution | `ModelLoaderNamesRegisterTypedFactories`, `ModelLoaderNamesRejectNullArguments`, and `GeneratedModelsLoadTogetherAndCreateTypedInstances` cover all six loader overloads, fluent return identities, typed instances, namespace coexistence and null guards. Existing standalone Part 2 tests verify idempotent registration, one-owner enforcement and null handling through `AddMachineVision`. No source-generator implementation, CLR namespace, wire identity or model payload was changed for these naming updates. The current69b1f5db9revision is running [CI](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38165826937), [package validation](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38165823359), [MCP usability](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38165826874), [CodeQL](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38165826906), and [Images CI](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38165826884). These runs are not claimed as completed results. **Earlier completed verification:** all seven default-TFM package archives were inspected after the package rename: exact IDs, 27 clean DLLs, correct dependencies/readmes/licenses, and unchanged pinned model hashes. [CI onc75ec4fa6](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/38142519760) passed, including the formerly failing Linux batch and required summary. Its unchanged coverage gate passed at **88.56% lines, 78.96% branches, 84.28% patch** against the 75% patch floor. The later bounded-Publish-helper regressions reproduced 13 failures before the fix and passed afterward; the full mainline triggering fixture passed 67 tests on each of net10/net48. These are historical results, not current full-matrix results. <details> <summary>Executed API naming validation commands and outcomes</summary> Run from the worktree root using the established artifact trees. Dependency builds were performed before the no-build full net10 run; the focused loader/hosting selection was rebuilt and rerun after the final null-guard adjustment. ```powershell $files = 'C:\Users\mschier\.copilot\session-state\deb2ba10-b0e9-4a44-8783-8331bc850814\files' $env:DOTNET_CLI_USE_MSBUILD_SERVER = '0' $env:TEMP = 'C:\Temp\mv-deb2\followup' $env:TMP = $env:TEMP # Passed: 572; Failed: 0; Skipped: 1. dotnet test tests\Opc.Ua.Vision.Tests\Opc.Ua.Vision.Tests.csproj -c Release -f net10.0 --no-build --no-restore --artifacts-path artifacts\vision-followup -p:CustomTestTarget=net10.0 -p:UseSharedCompilation=false -m:1 -nr:false --logger 'console;verbosity=minimal' --logger trx --results-directory "$files\vision-api-names-net10" -- 'NUnit.WorkDirectory=C:\Temp\mv-deb2\followup' # Passed: 9; Failed: 0; Skipped: 0, on the final source. dotnet test tests\Opc.Ua.Vision.Tests\Opc.Ua.Vision.Tests.csproj -c Release -f net10.0 --no-restore --artifacts-path artifacts\vision-followup -p:CustomTestTarget=net10.0 -p:UseSharedCompilation=false -m:1 -nr:false --filter 'FullyQualifiedName~MachineVisionModelTests|FullyQualifiedName~StandalonePartTwoRegistrationUsesOneOwnerAndOneModelProvider|FullyQualifiedName~StandalonePartTwoRequiresRegistrationAndRejectsCompetingOwnership' --logger 'console;verbosity=minimal' --logger trx --results-directory "$files\vision-api-names-final-model" -- 'NUnit.WorkDirectory=C:\Temp\mv-deb2\followup' # Passed: 198; Failed: 0; Skipped: 0. dotnet test tests\Opc.Ua.Tools.Tests\Opc.Ua.Tools.Tests.csproj -c Release -f net10.0 --no-restore --artifacts-path artifacts\vision-followup -p:CustomTestTarget=net10.0 -p:UseSharedCompilation=false -m:1 -nr:false --filter 'FullyQualifiedName~VisionMachineToolsTests|FullyQualifiedName~McpHostBuilderTests|FullyQualifiedName~McpToolProfileCompositionTests' --logger 'console;verbosity=minimal' --logger trx --results-directory "$files\vision-api-names-final-mcp" -- 'NUnit.WorkDirectory=C:\Temp\mv-deb2\followup' $env:TEMP = 'C:\Temp\mv-deb2\followup48' $env:TMP = $env:TEMP # Passed: 515; Failed: 0; Skipped: 0. dotnet test tests\Opc.Ua.Vision.Tests\Opc.Ua.Vision.Tests.csproj -c Debug -f net48 --no-restore --artifacts-path "$files\solution-net48-artifacts" -p:CustomTestTarget=net48 -p:UseSharedCompilation=false -m:1 -nr:false --logger 'console;verbosity=minimal' --logger trx --results-directory "$files\vision-api-names-net48-final" -- 'NUnit.WorkDirectory=C:\Temp\mv-deb2\followup48' ``` Opt-in long-running/stress/durable tiers have not been rerun locally; the unqualified **all tests** checklist item remains open. Original implementation matrix counts are not presented as current results. </details> ## Related Issues - Fixes #4732. The requester reviewed and approved the implementation plan and subsequent packaging/API decisions in the development session. The tracking issue records the design; maintainer architectural discussion/sign-off there is still pending. This PR remains a draft. ## Checklist _Put an `x` in the boxes that apply. You can complete these step by step after opening the PR._ - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [x] I have addressed **all** PR feedback received.
45 KiB
OPC UA Device Integration (DI)
Glossary: In this document, DI refers to OPC UA Device Integration (companion specification OPC 10000-100), not to .NET Dependency Injection (covered in DependencyInjection.md). Wherever this document uses the unqualified initialism "DI" it always means the companion spec; .NET-DI mentions are spelled out as "Dependency Injection (.NET DI)" or appear with
Microsoft.Extensions.DependencyInjectionin context.
End-to-end developer guide for the Opc.Ua.Di* library trio shipped
with this repository and the services.AddOpcUa() hosting model that
plugs it together.
Contents
- Library layout
- Quick start
- Device builder
- Device sub-type extensions
- Hosting integration
- Lock service
- Software update
- Client helpers
- What is supported (OPC 10000-100)
- See also
Library layout
| Library | Role |
|---|---|
Opc.Ua.Di |
Model assembly: source-generated NodeId tables, DataTypes, ObjectType client proxies, AddOpcUaDi(NodeStateCollection) extension. |
Opc.Ua.Di.Server |
Server: DiNodeManager, fluent topology/device builders, locking service, software-update package store, hosting integration. |
Opc.Ua.Di.Client |
Client: DiDeviceClient, DiDiscoveryClient, DiTopologyClient, DiLockClient, SoftwareUpdateClient, hosting integration. |
The running example is samples/DI/PumpDeviceIntegrationServer, a
companion-spec server that exposes a configurable number of fully
simulated PumpType instances. The sample uses the hand-written fluent
node-manager style for the common pump model and simulation wiring, then
uses ConfigureDevicesFor with the topology-element builder to add an
ad-hoc Diagnostics functional group to each pump. The simulated asset is
specified by its own product datasheet,
samples/DI/PumpDeviceIntegrationServer/DATASHEET.md,
which maps every nameplate field, engineering range and alarm trip point
to its OPC UA browse path.
Quick start
Plain Device Integration (DI) server
using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Hosting;
HostApplicationBuilder builder = Host.CreateApplicationBuilder(args);
builder.Services
.AddOpcUa()
.AddServer(o =>
{
o.ApplicationName = "MyDiServer";
o.EndpointUrls.Add("opc.tcp://localhost:48010/MyDiServer");
})
.AddOpcUaDi()
.ConfigureDevicesFor<DiNodeManager>(async ctx =>
{
var device = await ctx.CreateDeviceAsync(
new QualifiedName("Sensor_1", ctx.Manager.InstanceNamespaceIndex));
device.WithIdentification(id =>
{
id.Manufacturer = new LocalizedText("Acme");
id.SerialNumber = "SN-001";
id.DeviceClass = "Sensor";
});
});
await builder.Build().RunAsync();
Companion-spec server (Pumps + Device Integration)
builder.Services
.AddOpcUa()
.AddServer(o => { ... })
.AddNodeManager<Pumps.PumpNodeManagerFactory>()
// Pump factory already loads OPC UA Device Integration via its LoadPredefinedNodesAsync
// direct chain; do NOT call AddOpcUaDi() — that would
// double-register the OPC UA Device Integration namespace.
.ConfigureDevicesFor<Pumps.PumpNodeManager>(ctx =>
{
var manager = (Pumps.PumpNodeManager)ctx.Manager;
foreach (NodeId pumpNodeId in manager.PumpNodeIds)
{
ITopologyElementBuilder<PumpState> pump =
ctx.TopologyElement<PumpState>(pumpNodeId);
pump.WithFunctionalGroup(
new QualifiedName("Diagnostics", manager.InstanceNamespaceIndex),
group => group.Configure(node =>
node.WithProperty("LastError", Variant.From(string.Empty))));
}
return ValueTask.CompletedTask;
});
Client
builder.Services
.AddOpcUa()
.AddClient(o => { o.Configuration = ...; o.Session.Endpoint = ...; })
.AddOpcUaDi();
public sealed class MyAppService(
IDiDiscoveryService discovery,
Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>> deviceFactory,
Func<CancellationToken, ValueTask<DiTopologyClient>> topologyFactory)
{
public async Task PrintAsync(CancellationToken ct)
{
DiTopologyClient topology = await topologyFactory(ct);
await foreach (TopologyEntry entry in topology.EnumerateDevicesAsync(ct))
{
DiDeviceClient device = await deviceFactory(entry.NodeId, ct);
DeviceIdentification id = await device.ReadIdentificationAsync(ct);
Console.WriteLine($"{id.Manufacturer} {id.Model} ({id.SerialNumber})");
}
}
}
Device builder
The IDeviceBuilder<TDevice> fluent surface is the recommended way
to create and configure Device Integration device instances programmatically. It
lives in Opc.Ua.Di.Server.Builders and integrates with the broader
fluent API for node managers.
Runtime-created NodeIds use the server namespace.
DiNodeManagernow mints NodeIds for device and topology instances inInstanceNamespaceIndex, the server application's namespace derived fromApplicationConfiguration.ApplicationUri, rather than in the DI or companion-spec namespace of the parent. This follows the companion-spec modelling rules (for example OPC 10000-100 §13.4 and OPC 40223): nodes not defined by a specification must not use the standard namespace. The local server defines such nodes in its Local Server URI namespace. BrowseNames defined by DI or another companion specification keep that specification's namespace. UseInstanceNamespaceIndexfor application-defined instance names, functional groups, and properties.
Entry points
All entry points live on DiNodeManager:
// Default DeviceState organized by the Device Integration DeviceSet (or attached
// below whatever ResolveDefaultDeviceParent() returns).
ValueTask<IDeviceBuilder<DeviceState>> CreateDeviceAsync(
QualifiedName browseName,
NodeState? parent = null,
CancellationToken ct = default);
// Typed factory for ComponentType-derived companion-spec devices.
ValueTask<IDeviceBuilder<TDevice>> CreateDeviceAsync<TDevice>(
QualifiedName browseName,
NodeId typeDefinitionId,
Func<NodeState, TDevice> factory,
NodeState? parent = null,
CancellationToken ct = default)
where TDevice : ComponentState;
// Wrap an existing device.
IDeviceBuilder<TDevice> Device<TDevice>(TDevice device)
where TDevice : ComponentState;
IDeviceBuilder<TDevice> Device<TDevice>(NodeId nodeId)
where TDevice : ComponentState;
IDeviceBuilder<TDevice> DeviceByBrowseName<TDevice>(
QualifiedName browseName,
NodeState? parent = null)
where TDevice : ComponentState;
// Wrap an existing TopologyElementType-derived companion instance.
ITopologyElementBuilder<TElement> TopologyElement<TElement>(TElement element)
where TElement : TopologyElementState;
ITopologyElementBuilder<TElement> TopologyElement<TElement>(NodeId nodeId)
where TElement : TopologyElementState;
ITopologyElementBuilder<TElement> TopologyElementByBrowseName<TElement>(
QualifiedName browseName,
NodeState? parent = null)
where TElement : TopologyElementState;
CreateDeviceAsync performs five steps:
-
Resolves the parent (default: Device Integration
DeviceSet; subclasses overrideResolveDefaultDeviceParent()— e.g. machinery managers can return theMachinesfolder). -
Uses
Organizesfor the well-known DIDeviceSet; explicit custom parents retainHasComponent. -
Fails fast if a child with the same browse name already exists (
StatusCodes.BadBrowseNameDuplicated). -
Materializes the instance through the source-generated
CreateInstanceOf<Type>factory, such asCreateInstanceOfDeviceType. The factory adds the type's mandatory children andHasInterfacereferences. ForDeviceType, the children are eight nameplate variables:Manufacturer,Model,HardwareRevision,SoftwareRevision,DeviceRevision,DeviceManual,SerialNumber, andRevisionCounter. It assigns each variable a DI-namespace BrowseName.Because the factory receives a BrowseName, it also rebases the subtree onto per-instance NodeIds in the server's application namespace (
DiNodeManager.InstanceNamespaceIndex, the Local Server URI namespace). This prevents instances of the same type from colliding on the generator's type NodeIds. It also keeps application nodes out of DI and other companion-spec namespaces. Finally, the factory setsBrowseName,SymbolicName, andDisplayName, and stampsTypeDefinitionId. -
Calls the real
AsyncCustomNodeManager.AddPredefinedNodeAsyncso the node create lifecycle, subscription wiring, type-tree registration, and root-notifier propagation all happen exactly as for nodes loaded from a NodeSet2.
Machinery-aware subclasses can additionally reference managed machines
from the OPC 40001 Machines entry point. DiNodeManager's helper adds
an Organizes reference to the existing instance instead of re-parenting
it, so the same machine remains organized by DeviceSet while also being
browsable from Machines.
Fluent surface
IDeviceBuilder<TDevice>
.WithIdentification(action<DeviceIdentificationData>)
.WithIdentificationGroup(action<IFunctionalGroupBuilder>)
.WithConfigurationGroup(action<IFunctionalGroupBuilder>)
.WithMaintenanceGroup(action<IFunctionalGroupBuilder>)
.WithDiagnosticsGroup(action<IFunctionalGroupBuilder>)
.WithStatusGroup(action<IFunctionalGroupBuilder>)
.WithOperationalGroup(action<IFunctionalGroupBuilder>)
.WithStatisticsGroup(action<IFunctionalGroupBuilder>)
.WithOperationCountersGroup(action<IFunctionalGroupBuilder>)
.WithFunctionalGroup(QualifiedName name, action<IFunctionalGroupBuilder>)
.ConnectsTo(NodeId other)
.ConnectsToParent(NodeId parent)
.Configure(action<TDevice, ISystemContext>)
.WithDeviceHealth(DeviceHealthEnumeration) // extension; requires TDevice : DeviceState
ITopologyElementBuilder<TElement> is the parallel surface for
generated companion types that derive directly from
TopologyElementType. It exposes only common topology operations:
functional groups, ConnectsTo references, typed node access, and
raw state configuration. The internal device-builder implementation
reuses the same behavior without changing the existing public
IDeviceBuilder<TDevice> contract. Component nameplates, support
information, software update, lifetime indications, and
DeviceHealth remain on their narrower component/device builders.
Identification properties
WithIdentification(action) populates the standard Device Integration nameplate
properties on the device. The mutable DeviceIdentificationData
record holds:
Manufacturer(LocalizedText,IsNull= unset)ManufacturerUri(string?)Model(LocalizedText,IsNull= unset)HardwareRevision,SoftwareRevision,DeviceRevision,ProductCode,DeviceManual,DeviceClass,SerialNumber,ProductInstanceUri(string?)RevisionCounter(int?)
Properties that exist as typed children on the device are updated in
place. The eight mandatory nameplate properties are always present
(materialised by CreateInstanceOfDeviceType), so setting them takes
the in-place path. Optional nameplate properties (ManufacturerUri,
ProductCode, ProductInstanceUri, DeviceClass) are created on
demand via NodeState.AddProperty<T, VariantBuilder>, re-qualified into
the DI namespace (never namespace 0), and registered with the
manager.
DI companion-spec compliance
Devices created through CreateDeviceAsync are modelled to the DI
companion spec: mandatory DeviceType children are present with
DI-namespace BrowseNames, the type's HasInterface references are
carried, and the software-update state-machine method children point at
their in-type MethodDeclarationIds. The model is intentionally lean
— OPC UA does not require optional interface members
(IVendorNameplateType/ITagNameplateType/ISupportInfoType members
such as AssetId, ProductCode, DeviceTypeImage, Documentation,
ImageSet, ProtocolSupport) to be instantiated, so they are omitted
unless the application adds them. An external compliance checker may still flag omitted optional members.
It may also report placeholder warnings for application-added
HasComponent children, such as a custom Diagnostics functional group
or the SoftwareUpdate facet. The specification permits these omissions
and extensions; they are not modelling errors.
Functional groups
Common Device Integration functional groups have typed builder methods.
Spec-defined groups keep their standard BrowseName namespace, for
example Identification, Maintenance, and Operational in the DI
namespace and Events in the Pumps namespace. Application-defined
groups use the server instance namespace; the diagnostics helper follows
that rule because the diagnostics group it creates is vendor-defined.
Arbitrary group names go through WithFunctionalGroup(qualifiedName, action).
Each call is idempotent: invoking the same accessor twice reuses the
existing group. The order of operations inside the builder is:
- Create the
FunctionalGroupStatechild (viaTopologyElementState.AddIdentificationorAddGroupIdentifier). - Normalise BrowseName, SymbolicName, DisplayName, NodeId (via
Context.NodeIdFactory) andTypeDefinitionId. - Register the group with the manager via
AddPredefinedNodeAsync. - Hand the
IFunctionalGroupBuilderto the configure delegate.
device.WithMaintenanceGroup(fg =>
{
fg.Organizes(device.Manufacturer!.NodeId);
fg.Node.WithProperty("LastMaintenanceDate", DateTime.UtcNow);
});
For vendor-specific groups, use the non-typed
WithFunctionalGroup(QualifiedName, action) overload. The browse
name's namespace index controls where the group lives; pass
DiNodeManager.InstanceNamespaceIndex for application-defined groups.
Reserve DI, Pumps, Machinery, or other companion-spec BrowseName
namespaces for nodes that are defined by those specifications. The
PumpDeviceIntegrationServer sample demonstrates this on Pump #2
to surface a custom Diagnostics folder:
pump.WithFunctionalGroup(
new QualifiedName("Diagnostics", ctx.Manager.InstanceNamespaceIndex),
fg => fg.Configure(node =>
node.WithProperty("LastError", string.Empty)
.WithProperty("ErrorCount", 0)
.WithProperty("LastSelfTest", DateTime.UtcNow)));
Topology references
ConnectsTo(NodeId) adds a forward Opc.Ua.Di.ReferenceTypes.ConnectsTo
reference; ConnectsToParent(NodeId) adds the inverse. Useful for
declaring physical / logical topology relationships outside the
hierarchical address-space tree.
Device health
WithDeviceHealth(DeviceHealthEnumeration) is an extension method
constrained to TDevice : DeviceState (where the typed
DeviceHealth child variable exists). Throws
StatusCodes.BadInvalidState if the device was constructed without
the DeviceHealth child — typically because the factory was
p => new DeviceState(p) rather than the generator-produced
CreateDeviceType factory. Callers can pre-populate the child via
Configure((dev, ctx) => ...) to avoid the error.
Subclass support
Companion-spec managers (PumpNodeManager, machinery managers)
inherit from DiNodeManager and gain the entire builder surface for
free. They typically override ResolveDefaultDeviceParent() to
return the companion-spec-specific container (Machines folder,
etc.) and supply their own typed factories to
CreateDeviceAsync<TPumpType>(...).
Device sub-type extensions
Three extension surfaces on top of IDeviceBuilder<TDevice> cover
optional OPC 10000-100 features:
Software / Block / ConfigurableObject (§5.4 advanced sub-types)
DeviceBuilderTypeExtensions adds typed materialisation helpers for
the §5.4 sub-types that are not provided by WithDeviceType itself:
SoftwareState sw = builder.AddSoftware(qn("Firmware"));
BlockState blk = builder.AddBlock(qn("InputBlock"));
ConfigurableObjectState cfg = builder.AddConfigurableObject(qn("DriverFolder"));
Each helper creates a typed child under the device, stamps a
manager-assigned NodeId via INodeIdFactory, sets the
HasComponent reference, registers the child via
AddPredefinedNodeAsync, and invokes an optional configure
callback. The returned typed state is ready for further
configuration through the standard NodeState APIs.
Lifetime indication (§10.6)
DeviceBuilderLifetimeExtensions.AddLifetimeIndication creates a
LifetimeVariableState under the device with a
LifetimeIndicationKind classifier covering all six §10.6 indication
sub-types:
device.AddLifetimeIndication(
qn("OperatingHours"),
LifetimeIndicationKind.Time,
startValue: 0.0);
device.AddLifetimeIndication(
qn("PartsProduced"),
LifetimeIndicationKind.NumberOfParts,
startValue: 0.0);
The classifier enum maps directly to OPC 10000-100 ObjectType ids:
LifetimeIndicationKind |
OPC UA ObjectType |
|---|---|
Time |
TimeIndicationType |
NumberOfParts |
NumberOfPartsIndicationType |
NumberOfUsages |
NumberOfUsagesIndicationType |
Length |
LengthIndicationType |
Diameter |
DiameterIndicationType |
SubstanceVolume |
SubstanceVolumeIndicationType |
DeviceBuilderLifetimeExtensions.ResolveIndicationTypeId(kind, namespaceUris) resolves the matching NodeId at runtime when
applications need to materialise the indication classifier object
themselves.
Support info (§5.15)
DeviceBuilderSupportInfoExtensions.WithSupportInfo creates an
ISupportInfoState child on the device (idempotent — re-uses the
existing instance on subsequent calls) and yields it through a
configure callback. The interface exposes
DocumentationFiles / ImageSet / ProtocolSupport folder
properties; consumers populate them by attaching FileState or
BaseObjectState children through the standard NodeState API.
File-backed children commonly use FileState wired to an
IFileSystemProvider from src/Opc.Ua.Server/FileSystem.
device.WithSupportInfo(info =>
{
info.Description = new LocalizedText("Support information for device 1");
// attach FileState children for DocumentationFiles / ImageSet
// / ProtocolSupport folders here, using IFileSystemProvider
// for content backing.
});
Hosting integration
Use AddOpcUaDi() and ConfigureDevicesFor<TNodeManager>() to add the
Device Integration library to the unified AddOpcUa()
Microsoft.Extensions.DependencyInjection hosting pattern.
Server-side surface
Microsoft.Extensions.DependencyInjection.OpcUaServerDiBuilderExtensions
adds three methods on IOpcUaServerBuilder:
IOpcUaServerBuilder AddOpcUaDi();
IOpcUaServerBuilder ConfigureDevicesFor<TNodeManager>(
Action<IDiPostSetupContext> configure)
where TNodeManager : DiNodeManager;
IOpcUaServerBuilder ConfigureDevicesFor<TNodeManager>(
Func<IDiPostSetupContext, ValueTask> configure)
where TNodeManager : DiNodeManager;
When to use AddOpcUaDi()
Call this when you want a plain Device Integration (DI) server
without any companion-spec subclass. It registers the
DiNodeManagerFactory so the hosted service stands up a pure
DiNodeManager.
services.AddOpcUa()
.AddServer(o => { ... })
.AddOpcUaDi();
Do NOT call AddOpcUaDi() alongside a companion-spec factory
that already loads OPC UA Device Integration (e.g. PumpNodeManagerFactory which loads
Device Integration + Machinery + Pumps). The Device Integration namespace would be registered twice
and the OPC UA server may reject the duplicate. AddOpcUaDi() throws
on its second invocation to surface the misuse early.
ConfigureDevicesFor<TNodeManager>(action)
Registers a post-setup configurator targeted at a specific manager type. The runner invokes each matching delegate after:
- the manager's
LoadPredefinedNodesAsynchas populatedPredefinedNodes; - the manager's
CreateAddressSpaceAsyncbase has wired up the type tree and root notifiers; - (for
FluentNodeManagerBasesubclasses) the user'sConfigureAsync(builder, ct)/Configure(builder)wiring and the subsequentawait builder.SealAsync(ct)are complete.
Configurator-type matching follows Type.IsAssignableFrom. A
delegate targeting DiNodeManager runs against every Device Integration-derived
manager (including PumpNodeManager); a delegate targeting
PumpNodeManager will NOT run against a plain DiNodeManager.
Multiple ConfigureDevicesFor<T> calls accumulate and run in
registration order. Exception semantics are fail-fast: any
exception thrown by a configurator aborts hosted-server startup with
a diagnostic that identifies the failing index and target type.
Context surface
The configurator receives an IDiPostSetupContext:
public interface IDiPostSetupContext
{
DiNodeManager Manager { get; }
CancellationToken CancellationToken { get; }
T GetRequiredService<T>() where T : notnull;
ValueTask<IDeviceBuilder<DeviceState>> CreateDeviceAsync(...);
ValueTask<IDeviceBuilder<TDevice>> CreateDeviceAsync<TDevice>(...) where TDevice : ComponentState;
IDeviceBuilder<TDevice> Device<TDevice>(NodeId nodeId) where TDevice : ComponentState;
IDeviceBuilder<TDevice> DeviceByBrowseName<TDevice>(QualifiedName name, NodeState? parent = null)
where TDevice : ComponentState;
ITopologyElementBuilder<TElement> TopologyElement<TElement>(NodeId nodeId)
where TElement : TopologyElementState;
ITopologyElementBuilder<TElement> TopologyElementByBrowseName<TElement>(
QualifiedName name,
NodeState? parent = null)
where TElement : TopologyElementState;
}
The context does not expose a raw IServiceProvider. Use
GetRequiredService<T>() to resolve application services
(intentionally narrow to discourage service-locator anti-patterns
and lifetime traps).
Architecture
| Component | Lifetime | Where |
|---|---|---|
IDiPostSetupRunner |
Singleton (registered by AddOpcUaDi/ConfigureDevicesFor) |
Opc.Ua.Di.Server.Hosting |
IDiPostSetupConfigurator |
Singleton (one per ConfigureDevicesFor call) |
Opc.Ua.Di.Server.Hosting |
DiNodeManagerFactory / PumpNodeManagerFactory |
Singleton (.NET-DI-aware ctor injects runner) | server / app |
DiNodeManager / PumpNodeManager |
Per-server startup (factory passes runner) | app |
The runner is injected into the manager via the factory. The base
DiNodeManager auto-invokes it at the end of its own
CreateAddressSpaceAsync for every concrete subclass:
- The base
DiNodeManager.CreateAddressSpaceAsynccallsLoadPredefinedNodesAsync→CreateFluentBuilder(...)→ConfigureAsync(builder, ct)→RegisterAuthoredNodesAsync→CompleteConfigureAsync→PostSetupRunner.RunAsync(this, ct)→SealConfigurationAsync(builder, ct)in that order. Sealing comes last because the fluent registries (simulations, event sources) are owned by the manager, not by a single builder, and sealing starts them — a post-setup configurator must still be able to register a simulation loop. - Subclasses (e.g.
PumpNodeManager) override theprotected virtual ValueTask ConfigureAsync(INodeManagerBuilder, CancellationToken)hook to materialise instances and drive the fluentINodeManagerBuilder. Because the hook is awaited, asynchronous setup and synchronous wiring live in one method; the base class owns node registration and sealing. The runner fires automatically once the builder is sealed — subclasses do not need to callPostSetupRunner.RunAsyncthemselves.
sequenceDiagram
autonumber
participant Host as Hosting / factory
participant Base as DiNodeManager
participant Sub as Subclass, e.g. PumpNodeManager
participant B as NodeManagerBuilder
participant Run as IDiPostSetupRunner
Host->>Base: CreateAddressSpaceAsync(externalReferences, ct)
Base->>Base: await LoadPredefinedNodesAsync
Note over Base: predefined nodes loaded, type tree wired
Base->>B: CreateFluentBuilder(InstanceNamespaceIndex)
Note over B: attached to the manager's event-source<br/>and simulation registries
Base->>Sub: await ConfigureAsync(builder, ct)
Note over Sub: asynchronous setup and synchronous wiring<br/>in one awaited method
Base->>Base: await RegisterAuthoredNodesAsync(builder, ct)
Base->>Base: await CompleteConfigureAsync(externalReferences, ct)
Base->>Run: await RunAsync(this, ct)
Note over Run: configurators still register simulation<br/>loops and event sources here
Base->>B: await SealConfigurationAsync(builder, ct)
Note over B: drain staged root notifiers,<br/>then start the simulations
Sealing is the last step for a reason: the fluent registries belong to
the manager rather than to one builder, and sealing starts them. Sealing
before RunAsync would leave the post-setup configurators unable to
register a simulation loop of their own.
Runtime conformance advertisement
DiNodeManager implements IConformanceContributor, so the hosted
server publishes the DI facets and conformance units that are actually
wired at startup. The server merges these contributions into
Server/ServerCapabilities/ServerProfileArray and
Server/ServerCapabilities/ConformanceUnits alongside the base server
profiles.
Companions composed into the same manager can call
RegisterConformanceContributor(IConformanceContributor) instead of creating
a subclass solely to append units. The registration is idempotent by contributor
instance, preserves the DI units, and reevaluates the contributor on each publication.
Contributors must not refer back to their owning manager. The
Machine Vision integration uses this path for Machinery-hosted
released models; it does not invent profile URIs.
The conformance units follow what is built:
| Runtime condition | Conformance units |
|---|---|
DI DeviceSet exists |
DI DeviceTopology |
A LockingServicesState has InitLock, RenewLock, or ExitLock wired |
DI Locking |
The same lock service also wires BreakLock |
DI BreakLocking |
| Any software-update loading mode is recorded | DI SU Software Update, DI SU PrepareForUpdate, DI SU Resume Update |
SoftwareLoadingMode.Direct |
DI SU DirectLoading |
SoftwareLoadingMode.Cached |
DI SU CachedLoading |
A facet is advertised only while every conformance unit the DI 1.05 profile database marks mandatory for it is advertised:
| Server profile URI | Mandatory conformance units | Advertised |
|---|---|---|
http://opcfoundation.org/UA-Profile/DI/Server/DeviceIntegrationHost |
DI DeviceTopology, DI Offline |
No: offline and online device representations are not built |
http://opcfoundation.org/UA-Profile/DI/Server/Locking |
DI Locking |
When a lock service is wired |
http://opcfoundation.org/UA-Profile/DI/Server/SoftwareUpdateBase |
DI SU Software Update |
When a software update is attached |
http://opcfoundation.org/UA-Profile/DI/Server/FileSystemLoading |
Software Update Base, DI SU FileSystem Loading, DI SU Installation for File System |
No: Package builds a PackageLoadingType, not a FileSystemLoadingType, and the installation offers InstallSoftwarePackage |
http://opcfoundation.org/UA-Profile/DI/Server/DirectLoading |
Software Update Base, DI SU DirectLoading, DI SU UpdateStatus |
No: the UpdateStatus variable is not built |
http://opcfoundation.org/UA-Profile/DI/Server/CachedLoading |
Software Update Base, DI SU CachedLoading, DI SU Installation for Cached Loading, DI SU UpdateStatus |
No: the UpdateStatus variable is not built and the installation offers InstallFiles |
Client-side surface
Microsoft.Extensions.DependencyInjection.OpcUaClientDiBuilderExtensions
adds a single extension method on IOpcUaClientBuilder:
IOpcUaClientBuilder AddOpcUaDi();
This registers four .NET-DI-friendly services that wrap the lazy
ManagedSession accessor produced by AddClient(...):
IDiDiscoveryService— recursive device discovery from theObjectsfolder; streamsDeviceEntryrecords asIAsyncEnumerable<DeviceEntry>so callers can begin processing before the browse completes.Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>>— validates a device NodeId and returns a typed client.Func<NodeId, CancellationToken, ValueTask<DiLockClient>>— client wrapper forLockingServicesType.InitLock/RenewLock/ExitLock/BreakLock.Func<CancellationToken, ValueTask<DiTopologyClient>>— topology browser for the Device Integration well-known folders.Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>>— software-version reader for a SoftwareUpdate instance.
Requires AddClient(...) to be called first — the extension throws
InvalidOperationException if the managed-session accessor is
missing when one of the factories is resolved.
Lock service
The lock service implements the OPC 10000-100 §10.5 locking facet.
It tracks ownership of every TopologyElementType.Lock instance in
the address space, enforces configurable timeouts, releases locks
automatically when the owning session closes, and exposes the four
spec-defined methods through the typed LockingServicesState proxy.
Components
| Type | Purpose |
|---|---|
ILockService |
Application-facing facade: InitLock, RenewLock, ExitLock, BreakLock, GetState. Thread-safe. |
LockState |
Snapshot record (Locked, LockingClient, LockingUser, RemainingLockTimeSeconds). |
LockStatus |
OPC 10000-100 status-code constants. |
DefaultLockService |
Default in-memory implementation backed by a ConcurrentDictionary. |
LockingServicesExtensions.BindToLockService |
Wires the four generated *MethodState.OnCall handlers on a LockingServicesState instance through an ILockService. |
Namespaces: Opc.Ua.Di.Server.Locking.
Status codes
Following OPC 10000-100 §10.5:
| Constant | Value | Returned from |
|---|---|---|
LockStatus.Ok |
0 | All methods (success) |
LockStatus.AlreadyLocked |
1 | InitLock only |
LockStatus.CouldNotLock |
2 | InitLock only |
LockStatus.NotLocked |
1 | RenewLock / ExitLock / BreakLock |
LockStatus.WrongClient |
2 | RenewLock / ExitLock |
Default lock service
var lockService = new DefaultLockService(
lockDuration: TimeSpan.FromMinutes(5), // optional, defaults to 5 min
timeProvider: TimeProvider.System); // optional, for tests
// Hook session-close so locks held by a disconnecting session are
// released automatically.
lockService.AttachToSessionManager(server.SessionManager);
Lock ownership is keyed by ServerSystemContext.SessionId. When the
service is invoked from a test (SystemContext rather than
ServerSystemContext), it falls back to a synthetic session id
derived from ISystemContext.UserId so unit tests can still
distinguish callers.
Binding to a LockingServicesState
The Device Integration spec defines a Lock child on every TopologyElementType
that implements four method invocations. Wire them through your
service:
LockingServicesState lockNode = device.Lock!;
lockNode.BindToLockService(elementId: device.NodeId, service: lockService);
BindToLockService reads lockNode.InitLock, RenewLock,
ExitLock, BreakLock and replaces their OnCall handlers with
delegates that route into the ILockService. The elementId
argument keys the service's internal dictionary — typically the
topology element's own NodeId so two different devices can hold
independent locks.
End-to-end flow
- Client calls
InitLock(context: "tag")on a device's Lock. - The method's
OnCallruns the boundILockService.InitLock, which checks the per-device record:- If unlocked / expired → record
(SessionId, "tag", UserId, now + duration), returnOk(0). - If already locked by another session → return
AlreadyLocked(1).
- If unlocked / expired → record
RenewLock(same session) extends the expiry timestamp; from a different session it returnsWrongClient(2).ExitLockremoves the record (subject to ownership check).BreakLockremoves the record regardless of ownership; intended for administrative recovery.- If the owning session closes (server-emitted
SessionClosingevent), theDefaultLockServicewalks its records and releases anything that was held by that session.
Hosting
Register the service as a singleton through standard
Microsoft.Extensions.DependencyInjection:
services.AddSingleton<ILockService, DefaultLockService>();
Then attach the session-close hook from inside a
ConfigureDevicesFor<TNodeManager> configurator once the server's
SessionManager is available:
.ConfigureDevicesFor<DiNodeManager>(ctx =>
{
ILockService svc = ctx.GetRequiredService<ILockService>();
if (svc is DefaultLockService defaultSvc)
{
defaultSvc.AttachToSessionManager(ctx.Manager.Server.SessionManager);
}
foreach (DeviceState device in ctx.Manager.PredefinedNodes
.Values.OfType<DeviceState>())
{
device.Lock?.BindToLockService(device.NodeId, svc);
}
});
Software update
The software-update facet implements OPC 10000-100 workflows for loading,
preparation, installation, power cycle, and confirmation. Attach it with
WithSoftwareUpdate; application handlers supply device-specific behavior.
The SDK supplies the state-machine wiring and file-transfer infrastructure.
Server-side: package store
ISoftwarePackageStore stores package metadata and payloads.
ISoftwareFolder maintains each device's Current / Previous / Future versions.
Both have memory and file-system implementations. See
Software Update storage abstractions
for their contracts and persistence choices.
Surface
Use the package-store contract
for operations, metadata, and stream ownership. The Software Update guide also
owns WithSoftwareUpdate options and handler hooks.
FileSystemPackageStore layout
Use the store through ISoftwarePackageStore, rather than modifying its backing
files directly. See file-system layout and provider composition
for the file-system provider and persistence options.
Composing with IFileSystemProvider
Reuse the configured provider as described in provider composition.
Hosting
Register the package store with the host and attach it to the device's software-update facet. See the hosted-server walkthrough and package seeding example.
Client-side software update
SoftwareUpdateClient reads versions, uploads packages, and exposes typed
state-machine operations. The usual workflow is upload, prepare, install, and
confirm; supported steps depend on the device's advertised update capabilities.
See uploading a package and
typed state-machine operations
for runnable call sequences.
The DI client integration registers
Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>> through
services.AddOpcUa().AddClient(...).AddOpcUaDi().
Client helpers
Beyond DiDeviceClient and DiDiscoveryClient, the
Opc.Ua.Di.Client library ships three typed client wrappers that
compose the standard OPC UA Session surface.
| Helper | Purpose |
|---|---|
DiLockClient |
Wraps the four LockingServicesType methods. |
DiTopologyClient |
Browses DeviceSet, NetworkSet, DeviceTopology. |
SoftwareUpdateClient |
Reads the software-version property of a SoftwareUpdateType instance. |
All three live in Opc.Ua.Di.Client and are registered automatically
when applications call services.AddOpcUa().AddClient(...).AddOpcUaDi()
on the client-side builder.
DiLockClient
public sealed class DiLockClient
{
public DiLockClient(ISession session, NodeId lockNodeId, ITelemetryContext telemetry);
public ValueTask<int> InitLockAsync(string context, CancellationToken ct = default);
public ValueTask<int> RenewLockAsync(CancellationToken ct = default);
public ValueTask<int> ExitLockAsync(CancellationToken ct = default);
public ValueTask<int> BreakLockAsync(CancellationToken ct = default);
}
Each method invokes the corresponding LockingServicesType.{Method}
generated NodeId on the server and returns the integer status code
(see the LockStatus table for the OPC spec values).
The constructor takes the NodeId of the Lock instance — typically
the device.Lock child, not the device itself. Resolve it via
Session.TranslateBrowsePathsToNodeIdsAsync or by browsing the
device's HasComponent references for a child named "Lock".
DiLockClient lockClient = new(session, lockNodeId, telemetry);
int status = await lockClient.InitLockAsync("client-tag");
if (status == LockStatus.Ok)
{
try
{
// Do work that requires exclusive access.
}
finally
{
await lockClient.ExitLockAsync();
}
}
DiTopologyClient
public sealed class DiTopologyClient
{
public DiTopologyClient(ISession session, ITelemetryContext telemetry);
public NodeId DeviceSetId { get; }
public NodeId NetworkSetId { get; }
public NodeId DeviceTopologyId { get; }
public IAsyncEnumerable<TopologyEntry> EnumerateDevicesAsync(CancellationToken ct = default);
public IAsyncEnumerable<TopologyEntry> EnumerateNetworksAsync(CancellationToken ct = default);
public IAsyncEnumerable<TopologyEntry> EnumerateChildrenAsync(NodeId parentNodeId, CancellationToken ct = default);
}
public sealed record TopologyEntry(
NodeId NodeId,
string DisplayName,
NodeId TypeDefinitionId,
QualifiedName BrowseName);
EnumerateDevicesAsync and EnumerateNetworksAsync browse the
hierarchical references of DeviceSet and NetworkSet and return
the direct children that are Objects. EnumerateChildrenAsync
provides the same surface for arbitrary nodes — useful when walking
the DeviceTopology tree.
DiTopologyClient topology = new(session, telemetry);
await foreach (TopologyEntry device in topology.EnumerateDevicesAsync())
{
Console.WriteLine($"{device.BrowseName}: {device.DisplayName}");
}
Hosting registration
When services.AddOpcUa().AddClient(o => { ... }).AddOpcUaDi() is
called, the following factories are registered as singletons:
Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>>
Func<NodeId, CancellationToken, ValueTask<DiLockClient>>
Func<CancellationToken, ValueTask<DiTopologyClient>>
Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>>
IDiDiscoveryService
Inject the factory you need into your application services; the
factory opens (or reuses) the lazy ManagedSession on first call.
public sealed class MyMonitor(
Func<CancellationToken, ValueTask<DiTopologyClient>> topologyFactory,
Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>> deviceFactory,
Func<NodeId, CancellationToken, ValueTask<DiLockClient>> lockFactory)
{
public async Task ScanAsync(CancellationToken ct)
{
DiTopologyClient topo = await topologyFactory(ct);
await foreach (TopologyEntry e in topo.EnumerateDevicesAsync(ct))
{
DiDeviceClient dev = await deviceFactory(e.NodeId, ct);
DeviceIdentification id = await dev.ReadIdentificationAsync(ct);
// ...
}
}
}
What is supported (OPC 10000-100)
References are to the OPC 10000-100 (DI v1.05) specification sections.
Foundation — nameplates and topology elements
TopologyElementType(§5.2) — abstract base exposed throughITopologyElementBuilder<TElement>.IVendorNameplateType(§5.10) exposesManufacturer,Model,SerialNumber,HardwareRevision,SoftwareRevision,DeviceRevision,DeviceManual,DeviceClass,ProductInstanceUri, andProductCode. Populate these properties withIDeviceBuilder.WithIdentification(...).ITagNameplateType(§5.11) — AssetId, ComponentName, DeviceRevision. Populated by the same builder.IDeviceHealthType(§5.12) — DeviceHealth enum plus the four NAMUR alarm references.IAssetLocationIndicationType(§5.13) —StartLocationIndication/StopLocationIndicationmethods.IOperationCounterType(§5.14) — PowerOnDuration, OperationDuration, EstimatedReturnedOperationDuration, EstimatedReturnedPowerOnDuration.
Device tree
ComponentType(§5.3) — abstract; materialised viaIDeviceBuilder.DeviceType(§5.4) —IDeviceBuilder.WithDeviceType<TDeviceState>(factory).SoftwareType,BlockType,ConfigurableObjectType(§5.4 advanced sub-types) —IDeviceBuilder.AddSoftware,AddBlock,AddConfigurableObject.
Topology references
ConnectsTo(§5.6.2) —ITopologyElementBuilder.ConnectsTo(other).ConnectsToParent(§5.6.3) —ITopologyElementBuilder.ConnectsToParent(other).IsOnline(§5.6.4) — exposed for online-component wiring.UpdateParent,CanUpdate(§5.6.5–§5.6.6) — used by software update.
Topology containers
DeviceSet(§6.2) — well-known instance, auto-created byDiNodeManagerunderObjectsFolder;IDeviceBuilderparents devices here by default.NetworkSet(§6.3) — well-known instance.DeviceTopology(§6.4) — well-known instance; topology references attach here.NetworkType,ConnectionPointType,ProtocolType(§6.5–§6.7).
Functional groups (§5.7)
All eight well-known Device Integration functional groups are exposed
through typed methods on ITopologyElementBuilder; device builders
inherit the same surface:
Identification,Configuration,Maintenance,Diagnostics,Statistics,Status,Operational,OperationCounters.
Custom groups go through WithFunctionalGroup(qualifiedName, action).
Lock service (§10.5)
LockingServicesTypeand four method types:InitLockMethodType,RenewLockMethodType,ExitLockMethodType, andBreakLockMethodType.ILockServiceandDefaultLockServicewire these methods and provide session ownership, configurable timeouts, and cleanup when a session closes.
Software update (§10.3)
SoftwareUpdateType— orchestrates the loading + state-machine wiring.SoftwareLoadingType,PackageLoadingType(§10.3.4) — abstract bases.DirectLoadingType,CachedLoadingType,FileSystemLoadingType(§10.3.4) — the three loading variants.SoftwareVersionType(§10.3.6) — Manufacturer, ProductInstanceUri, SoftwareRevision, PatchIdentifiers, ReleaseDate, ChangeLog, Hash.- Generated proxies for
PrepareForUpdateStateMachineType(§10.3.7),InstallationStateMachineType(§10.3.8),PowerCycleStateMachineType(§10.3.9), andConfirmationStateMachineType(§10.3.10), driven by the application. - Storage abstraction:
ISoftwarePackageStorewithMemoryPackageStoreandFileSystemPackageStoreimplementations.
Support info & lifetime indication
ISupportInfoType(§5.15) —IDeviceBuilder.WithSupportInfo(configure). Backing foldersDocumentationFiles/ImageSet/ProtocolSupportacceptFileState/BaseObjectStatechildren; file content commonly backed byIFileSystemProvider.LifetimeVariableType+ 6 indication sub-types (§10.6) —IDeviceBuilder.AddLifetimeIndication(kind, …). Classifier kinds:Time,NumberOfParts,NumberOfUsages,Length,Diameter,SubstanceVolume.
NAMUR alarms (§10.2)
DeviceHealthDiagnosticAlarmType(abstract) and the four concrete alarm types (FailureAlarmType,CheckFunctionAlarmType,OffSpecAlarmType,MaintenanceRequiredAlarmType) — generated proxies wired via the fluentIAlarmBuilder<TState>+ActivatesAlarmpatterns fromsrc/Opc.Ua.Server/Fluent.
DataTypes & VariableTypes
The Opc.Ua.Di model library includes these source-generated Device
Integration DataTypes:
DeviceHealthEnumerationSoftwareClassLocationIndicationTypeSoftwareVersionFileTypeUpdateBehaviorFetchResultDataTypeTransferResultErrorDataTypeTransferResultDataDataTypeParameterResultDataType
Not yet implemented
TransferServicesType(§10.4) — parameter set transfer.- Offline and online device representations (§6.3) — needed for the
DI Offlineconformance unit and so for the DeviceIntegrationHost facet. - The
UpdateStatusvariable ofSoftwareUpdateType(§8.4.1.8) and aFileSystemLoadingTypeloading mode — needed for the Direct, Cached and FileSystem Loading facets (see Runtime conformance advertisement).
See also
- FileSystemClient — file-transfer client used by
SoftwareUpdateClientandFileSystemPackageStore. - Source-generated NodeManagers — the underlying source generator and fluent API.