Files
UA-.NETStandard/docs/DeviceIntegration.md
T
Marc Schier c4e0721a29 Add a documentation learning path and fix issues found while verifying it (#4555)
## Summary

### Documentation
- Stage the documentation index as a learning path: a first application,
independent client, server, and PubSub paths, then data and services,
companion models, production, advanced integration, and draft or
experimental capabilities.
- Add Getting started (repository samples or NuGet packages), OPC UA
concepts, Your first information model, and a production readiness
checklist.
- Add Native AOT application publishing, a first PubSub publisher and
subscriber exchange, and the UDP transport options.
- Add or expand contents navigation throughout `docs/`, and keep
contributor documentation separate.
- Correct outdated SDK examples and capability guidance, consolidate
repeated explanations into canonical guides, and repair local links and
heading structure.
- Rewrite What's New in 2.0 as a concise feature overview with short
linked details; keep migration instructions in the Migration Guide.
- Expand the feature catalogue with specification IDs, GDS, LDS, the OPC
10000-21 onboarding registrar, ISA-95, xRegistry, OpenUSD, and
sample-local models; distinguish draft status, explain crypto
pluggability, and bring performance guidance forward.
- Address review feedback on wording, active monitored items during
shadow reload, and the `Samples.md` filename and references.
- Regenerate the `opcua-v20-migration` plugin's bundled copy of the
migration guides so it matches the edited `docs/migrate/2.0.x` guides.
- Merge the latest `master`, preserving upstream resource-isolation
guidance within the task-based documentation index.
- Retain deferred Lingity findings where appropriate; this PR does not
claim that every document meets the Lingity score thresholds.

### Fixes found while verifying the guides
Each fix has regression tests that fail without it.
- **Client:** V2 subscriptions compared their lifetime with the
operation timeout instead of the session timeout, and logged a spurious
warning. `ISubscriptionEngineContext`, which is new in 2.0, gains a
`SessionTimeout` property; implementations must add it.
- **PubSub:** a subscriber now registers the `DataSetMetaData`
configured on its readers (OPC 10000-14 6.2.9.4), and the UADP decoder
decodes DataSetMessages that carry no ConfigurationVersion. Before, a
secured subscriber of the reference sample received no DataSets.
- **Source generator:** a ModelDesign method that declares its arguments
inline, without a method type, produced code that did not compile; it
now uses `MethodState`. The generated code of existing models is
unchanged.
- **MinimalClient sample:** waits for its first data-change notification
before it disconnects.

### Known issues, not addressed here
- UDP multicast: the publisher does not send on the interface that the
subscriber joins, and `MulticastLoopback` defaults to false. The PubSub
guide uses unicast for the exchange on one computer.
- The UDP metadata announcement is sent unsecured on secured writer
groups; a secured subscriber drops it with a warning.
- A server does not start in globalization-invariant mode, because
`ResourceManager` creates `CultureInfo("en-US")`. The Native AOT guide
cautions against the mode.

## Validation
- `git diff --check` and
`./.azurepipelines/validate-migration-plugin.ps1` (15 bundled migration
docs validated, plugin manifests synchronized).
- Local Markdown links, anchors, file-link casing, and contents lists
checked across all 87 documents under `docs/`. The index links every
top-level guide and every target of the previous index.
- Both Getting started routes, Your first information model, the PubSub
exchange, and the Native AOT publish of the Getting started client and
server were run as documented. The NuGet route and the tutorial use the
public `2.0.0-preview.5` packages.
- The changed libraries build for all target frameworks in Release
without warnings.
- Tests on .NET 10: Opc.Ua.SourceGeneration.Tests 199 passed;
Opc.Ua.SourceGeneration.Core.Tests 3,977 passed, 8 skipped;
Opc.Ua.Server.Tests `Fluent` category 621 passed; Opc.Ua.Client.Tests
subscription-engine tests 70 passed; Opc.Ua.PubSub.Tests 1,374 passed, 2
skipped; PubSub fuzz replay 145 passed. The new and affected tests also
pass on .NET Framework 4.8.
- Earlier merge validation: 174 resource-isolation tests passed on .NET
10.
- The full solution suite was not run locally.

Review and validation artifacts are maintained outside the repository.

---------

Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
2026-09-28 19:19:39 +00:00

44 KiB

OPC UA Device Integration (DI)

Glossary: In this document, DI refers to OPC UA Device Integration (companion specification OPC 10000-100), not to .NET Dependency Injection (covered in DependencyInjection.md). Wherever this document uses the unqualified initialism "DI" it always means the companion spec; .NET-DI mentions are spelled out as "Dependency Injection (.NET DI)" or appear with Microsoft.Extensions.DependencyInjection in context.

End-to-end developer guide for the Opc.Ua.Di* library trio shipped with this repository and the services.AddOpcUa() hosting model that plugs it together.

Contents

Library layout

Library Role
Opc.Ua.Di Model assembly: source-generated NodeId tables, DataTypes, ObjectType client proxies, AddOpcUaDi(NodeStateCollection) extension.
Opc.Ua.Di.Server Server: DiNodeManager, fluent topology/device builders, locking service, software-update package store, hosting integration.
Opc.Ua.Di.Client Client: DiDeviceClient, DiDiscoveryClient, DiTopologyClient, DiLockClient, SoftwareUpdateClient, hosting integration.

The running example is samples/DI/PumpDeviceIntegrationServer, a companion-spec server that exposes a configurable number of fully simulated PumpType instances. The sample uses the hand-written fluent node-manager style for the common pump model and simulation wiring, then uses ConfigureDevicesFor with the topology-element builder to add an ad-hoc Diagnostics functional group to each pump. The simulated asset is specified by its own product datasheet, samples/DI/PumpDeviceIntegrationServer/DATASHEET.md, which maps every nameplate field, engineering range and alarm trip point to its OPC UA browse path.

Quick start

Plain Device Integration (DI) server

using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Hosting;

HostApplicationBuilder builder = Host.CreateApplicationBuilder(args);
builder.Services
    .AddOpcUa()
    .AddServer(o =>
    {
        o.ApplicationName = "MyDiServer";
        o.EndpointUrls.Add("opc.tcp://localhost:48010/MyDiServer");
    })
    .AddOpcUaDi()
    .ConfigureDevicesFor<DiNodeManager>(async ctx =>
    {
        var device = await ctx.CreateDeviceAsync(
            new QualifiedName("Sensor_1", ctx.Manager.InstanceNamespaceIndex));
        device.WithIdentification(id =>
        {
            id.Manufacturer = new LocalizedText("Acme");
            id.SerialNumber = "SN-001";
            id.DeviceClass = "Sensor";
        });
    });

await builder.Build().RunAsync();

Companion-spec server (Pumps + Device Integration)

builder.Services
    .AddOpcUa()
    .AddServer(o => { ... })
    .AddNodeManager<Pumps.PumpNodeManagerFactory>()
    // Pump factory already loads OPC UA Device Integration via its LoadPredefinedNodesAsync
    // direct chain; do NOT call AddOpcUaDi() — that would
    // double-register the OPC UA Device Integration namespace.
    .ConfigureDevicesFor<Pumps.PumpNodeManager>(ctx =>
    {
        var manager = (Pumps.PumpNodeManager)ctx.Manager;
        foreach (NodeId pumpNodeId in manager.PumpNodeIds)
        {
            ITopologyElementBuilder<PumpState> pump =
                ctx.TopologyElement<PumpState>(pumpNodeId);
            pump.WithFunctionalGroup(
                new QualifiedName("Diagnostics", manager.InstanceNamespaceIndex),
                group => group.Configure(node =>
                    node.WithProperty("LastError", Variant.From(string.Empty))));
        }

        return ValueTask.CompletedTask;
    });

Client

builder.Services
    .AddOpcUa()
    .AddClient(o => { o.Configuration = ...; o.Session.Endpoint = ...; })
    .AddOpcUaDi();

public sealed class MyAppService(
    IDiDiscoveryService discovery,
    Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>> deviceFactory,
    Func<CancellationToken, ValueTask<DiTopologyClient>> topologyFactory)
{
    public async Task PrintAsync(CancellationToken ct)
    {
        DiTopologyClient topology = await topologyFactory(ct);
        await foreach (TopologyEntry entry in topology.EnumerateDevicesAsync(ct))
        {
            DiDeviceClient device = await deviceFactory(entry.NodeId, ct);
            DeviceIdentification id = await device.ReadIdentificationAsync(ct);
            Console.WriteLine($"{id.Manufacturer} {id.Model} ({id.SerialNumber})");
        }
    }
}

Device builder

The IDeviceBuilder<TDevice> fluent surface is the recommended way to create and configure Device Integration device instances programmatically. It lives in Opc.Ua.Di.Server.Builders and integrates with the broader fluent API for node managers.

Runtime-created NodeIds use the server namespace. DiNodeManager now mints NodeIds for device and topology instances in InstanceNamespaceIndex, the server application's namespace derived from ApplicationConfiguration.ApplicationUri, rather than in the DI or companion-spec namespace of the parent. This follows the companion-spec modelling rules (for example OPC 10000-100 §13.4 and OPC 40223): nodes not defined by a specification must not use the standard namespace. The local server defines such nodes in its Local Server URI namespace. BrowseNames defined by DI or another companion specification keep that specification's namespace. Use InstanceNamespaceIndex for application-defined instance names, functional groups, and properties.

Entry points

All entry points live on DiNodeManager:

// Default DeviceState organized by the Device Integration DeviceSet (or attached
// below whatever ResolveDefaultDeviceParent() returns).
ValueTask<IDeviceBuilder<DeviceState>> CreateDeviceAsync(
    QualifiedName browseName,
    NodeState? parent = null,
    CancellationToken ct = default);

// Typed factory for ComponentType-derived companion-spec devices.
ValueTask<IDeviceBuilder<TDevice>> CreateDeviceAsync<TDevice>(
    QualifiedName browseName,
    NodeId typeDefinitionId,
    Func<NodeState, TDevice> factory,
    NodeState? parent = null,
    CancellationToken ct = default)
    where TDevice : ComponentState;

// Wrap an existing device.
IDeviceBuilder<TDevice> Device<TDevice>(TDevice device)
    where TDevice : ComponentState;
IDeviceBuilder<TDevice> Device<TDevice>(NodeId nodeId)
    where TDevice : ComponentState;
IDeviceBuilder<TDevice> DeviceByBrowseName<TDevice>(
    QualifiedName browseName,
    NodeState? parent = null)
    where TDevice : ComponentState;

// Wrap an existing TopologyElementType-derived companion instance.
ITopologyElementBuilder<TElement> TopologyElement<TElement>(TElement element)
    where TElement : TopologyElementState;
ITopologyElementBuilder<TElement> TopologyElement<TElement>(NodeId nodeId)
    where TElement : TopologyElementState;
ITopologyElementBuilder<TElement> TopologyElementByBrowseName<TElement>(
    QualifiedName browseName,
    NodeState? parent = null)
    where TElement : TopologyElementState;

CreateDeviceAsync performs five steps:

  1. Resolves the parent (default: Device Integration DeviceSet; subclasses override ResolveDefaultDeviceParent() — e.g. machinery managers can return the Machines folder).

  2. Uses Organizes for the well-known DI DeviceSet; explicit custom parents retain HasComponent.

  3. Fails fast if a child with the same browse name already exists (StatusCodes.BadBrowseNameDuplicated).

  4. Materializes the instance through the source-generated CreateInstanceOf<Type> factory, such as CreateInstanceOfDeviceType. The factory adds the type's mandatory children and HasInterface references. For DeviceType, the children are eight nameplate variables: Manufacturer, Model, HardwareRevision, SoftwareRevision, DeviceRevision, DeviceManual, SerialNumber, and RevisionCounter. It assigns each variable a DI-namespace BrowseName.

    Because the factory receives a BrowseName, it also rebases the subtree onto per-instance NodeIds in the server's application namespace (DiNodeManager.InstanceNamespaceIndex, the Local Server URI namespace). This prevents instances of the same type from colliding on the generator's type NodeIds. It also keeps application nodes out of DI and other companion-spec namespaces. Finally, the factory sets BrowseName, SymbolicName, and DisplayName, and stamps TypeDefinitionId.

  5. Calls the real AsyncCustomNodeManager.AddPredefinedNodeAsync so the node create lifecycle, subscription wiring, type-tree registration, and root-notifier propagation all happen exactly as for nodes loaded from a NodeSet2.

Machinery-aware subclasses can additionally reference managed machines from the OPC 40001 Machines entry point. DiNodeManager's helper adds an Organizes reference to the existing instance instead of re-parenting it, so the same machine remains organized by DeviceSet while also being browsable from Machines.

Fluent surface

IDeviceBuilder<TDevice>
    .WithIdentification(action<DeviceIdentificationData>)
    .WithIdentificationGroup(action<IFunctionalGroupBuilder>)
    .WithConfigurationGroup(action<IFunctionalGroupBuilder>)
    .WithMaintenanceGroup(action<IFunctionalGroupBuilder>)
    .WithDiagnosticsGroup(action<IFunctionalGroupBuilder>)
    .WithStatusGroup(action<IFunctionalGroupBuilder>)
    .WithOperationalGroup(action<IFunctionalGroupBuilder>)
    .WithStatisticsGroup(action<IFunctionalGroupBuilder>)
    .WithOperationCountersGroup(action<IFunctionalGroupBuilder>)
    .WithFunctionalGroup(QualifiedName name, action<IFunctionalGroupBuilder>)
    .ConnectsTo(NodeId other)
    .ConnectsToParent(NodeId parent)
    .Configure(action<TDevice, ISystemContext>)
    .WithDeviceHealth(DeviceHealthEnumeration)   // extension; requires TDevice : DeviceState

ITopologyElementBuilder<TElement> is the parallel surface for generated companion types that derive directly from TopologyElementType. It exposes only common topology operations: functional groups, ConnectsTo references, typed node access, and raw state configuration. The internal device-builder implementation reuses the same behavior without changing the existing public IDeviceBuilder<TDevice> contract. Component nameplates, support information, software update, lifetime indications, and DeviceHealth remain on their narrower component/device builders.

Identification properties

WithIdentification(action) populates the standard Device Integration nameplate properties on the device. The mutable DeviceIdentificationData record holds:

  • Manufacturer (LocalizedText, IsNull = unset)
  • ManufacturerUri (string?)
  • Model (LocalizedText, IsNull = unset)
  • HardwareRevision, SoftwareRevision, DeviceRevision, ProductCode, DeviceManual, DeviceClass, SerialNumber, ProductInstanceUri (string?)
  • RevisionCounter (int?)

Properties that exist as typed children on the device are updated in place. The eight mandatory nameplate properties are always present (materialised by CreateInstanceOfDeviceType), so setting them takes the in-place path. Optional nameplate properties (ManufacturerUri, ProductCode, ProductInstanceUri, DeviceClass) are created on demand via NodeState.AddProperty<T, VariantBuilder>, re-qualified into the DI namespace (never namespace 0), and registered with the manager.

DI companion-spec compliance

Devices created through CreateDeviceAsync are modelled to the DI companion spec: mandatory DeviceType children are present with DI-namespace BrowseNames, the type's HasInterface references are carried, and the software-update state-machine method children point at their in-type MethodDeclarationIds. The model is intentionally lean — OPC UA does not require optional interface members (IVendorNameplateType/ITagNameplateType/ISupportInfoType members such as AssetId, ProductCode, DeviceTypeImage, Documentation, ImageSet, ProtocolSupport) to be instantiated, so they are omitted unless the application adds them. An external compliance checker may still flag omitted optional members. It may also report placeholder warnings for application-added HasComponent children, such as a custom Diagnostics functional group or the SoftwareUpdate facet. The specification permits these omissions and extensions; they are not modelling errors.

Functional groups

Common Device Integration functional groups have typed builder methods. Spec-defined groups keep their standard BrowseName namespace, for example Identification, Maintenance, and Operational in the DI namespace and Events in the Pumps namespace. Application-defined groups use the server instance namespace; the diagnostics helper follows that rule because the diagnostics group it creates is vendor-defined. Arbitrary group names go through WithFunctionalGroup(qualifiedName, action). Each call is idempotent: invoking the same accessor twice reuses the existing group. The order of operations inside the builder is:

  1. Create the FunctionalGroupState child (via TopologyElementState.AddIdentification or AddGroupIdentifier).
  2. Normalise BrowseName, SymbolicName, DisplayName, NodeId (via Context.NodeIdFactory) and TypeDefinitionId.
  3. Register the group with the manager via AddPredefinedNodeAsync.
  4. Hand the IFunctionalGroupBuilder to the configure delegate.
device.WithMaintenanceGroup(fg =>
{
    fg.Organizes(device.Manufacturer!.NodeId);
    fg.Node.WithProperty("LastMaintenanceDate", DateTime.UtcNow);
});

For vendor-specific groups, use the non-typed WithFunctionalGroup(QualifiedName, action) overload. The browse name's namespace index controls where the group lives; pass DiNodeManager.InstanceNamespaceIndex for application-defined groups. Reserve DI, Pumps, Machinery, or other companion-spec BrowseName namespaces for nodes that are defined by those specifications. The PumpDeviceIntegrationServer sample demonstrates this on Pump #2 to surface a custom Diagnostics folder:

pump.WithFunctionalGroup(
    new QualifiedName("Diagnostics", ctx.Manager.InstanceNamespaceIndex),
    fg => fg.Configure(node =>
        node.WithProperty("LastError", string.Empty)
            .WithProperty("ErrorCount", 0)
            .WithProperty("LastSelfTest", DateTime.UtcNow)));

Topology references

ConnectsTo(NodeId) adds a forward Opc.Ua.Di.ReferenceTypes.ConnectsTo reference; ConnectsToParent(NodeId) adds the inverse. Useful for declaring physical / logical topology relationships outside the hierarchical address-space tree.

Device health

WithDeviceHealth(DeviceHealthEnumeration) is an extension method constrained to TDevice : DeviceState (where the typed DeviceHealth child variable exists). Throws StatusCodes.BadInvalidState if the device was constructed without the DeviceHealth child — typically because the factory was p => new DeviceState(p) rather than the generator-produced CreateDeviceType factory. Callers can pre-populate the child via Configure((dev, ctx) => ...) to avoid the error.

Subclass support

Companion-spec managers (PumpNodeManager, machinery managers) inherit from DiNodeManager and gain the entire builder surface for free. They typically override ResolveDefaultDeviceParent() to return the companion-spec-specific container (Machines folder, etc.) and supply their own typed factories to CreateDeviceAsync<TPumpType>(...).

Device sub-type extensions

Three extension surfaces on top of IDeviceBuilder<TDevice> cover optional OPC 10000-100 features:

Software / Block / ConfigurableObject (§5.4 advanced sub-types)

DeviceBuilderTypeExtensions adds typed materialisation helpers for the §5.4 sub-types that are not provided by WithDeviceType itself:

SoftwareState           sw    = builder.AddSoftware(qn("Firmware"));
BlockState              blk   = builder.AddBlock(qn("InputBlock"));
ConfigurableObjectState cfg   = builder.AddConfigurableObject(qn("DriverFolder"));

Each helper creates a typed child under the device, stamps a manager-assigned NodeId via INodeIdFactory, sets the HasComponent reference, registers the child via AddPredefinedNodeAsync, and invokes an optional configure callback. The returned typed state is ready for further configuration through the standard NodeState APIs.

Lifetime indication (§10.6)

DeviceBuilderLifetimeExtensions.AddLifetimeIndication creates a LifetimeVariableState under the device with a LifetimeIndicationKind classifier covering all six §10.6 indication sub-types:

device.AddLifetimeIndication(
    qn("OperatingHours"),
    LifetimeIndicationKind.Time,
    startValue: 0.0);

device.AddLifetimeIndication(
    qn("PartsProduced"),
    LifetimeIndicationKind.NumberOfParts,
    startValue: 0.0);

The classifier enum maps directly to OPC 10000-100 ObjectType ids:

LifetimeIndicationKind OPC UA ObjectType
Time TimeIndicationType
NumberOfParts NumberOfPartsIndicationType
NumberOfUsages NumberOfUsagesIndicationType
Length LengthIndicationType
Diameter DiameterIndicationType
SubstanceVolume SubstanceVolumeIndicationType

DeviceBuilderLifetimeExtensions.ResolveIndicationTypeId(kind, namespaceUris) resolves the matching NodeId at runtime when applications need to materialise the indication classifier object themselves.

Support info (§5.15)

DeviceBuilderSupportInfoExtensions.WithSupportInfo creates an ISupportInfoState child on the device (idempotent — re-uses the existing instance on subsequent calls) and yields it through a configure callback. The interface exposes DocumentationFiles / ImageSet / ProtocolSupport folder properties; consumers populate them by attaching FileState or BaseObjectState children through the standard NodeState API. File-backed children commonly use FileState wired to an IFileSystemProvider from src/Opc.Ua.Server/FileSystem.

device.WithSupportInfo(info =>
{
    info.Description = new LocalizedText("Support information for device 1");
    // attach FileState children for DocumentationFiles / ImageSet
    // / ProtocolSupport folders here, using IFileSystemProvider
    // for content backing.
});

Hosting integration

Use AddOpcUaDi() and ConfigureDevicesFor<TNodeManager>() to add the Device Integration library to the unified AddOpcUa() Microsoft.Extensions.DependencyInjection hosting pattern.

Server-side surface

Microsoft.Extensions.DependencyInjection.OpcUaServerDiBuilderExtensions adds three methods on IOpcUaServerBuilder:

IOpcUaServerBuilder AddOpcUaDi();

IOpcUaServerBuilder ConfigureDevicesFor<TNodeManager>(
    Action<IDiPostSetupContext> configure)
    where TNodeManager : DiNodeManager;

IOpcUaServerBuilder ConfigureDevicesFor<TNodeManager>(
    Func<IDiPostSetupContext, ValueTask> configure)
    where TNodeManager : DiNodeManager;

When to use AddOpcUaDi()

Call this when you want a plain Device Integration (DI) server without any companion-spec subclass. It registers the DiNodeManagerFactory so the hosted service stands up a pure DiNodeManager.

services.AddOpcUa()
    .AddServer(o => { ... })
    .AddOpcUaDi();

Do NOT call AddOpcUaDi() alongside a companion-spec factory that already loads OPC UA Device Integration (e.g. PumpNodeManagerFactory which loads Device Integration + Machinery + Pumps). The Device Integration namespace would be registered twice and the OPC UA server may reject the duplicate. AddOpcUaDi() throws on its second invocation to surface the misuse early.

ConfigureDevicesFor<TNodeManager>(action)

Registers a post-setup configurator targeted at a specific manager type. The runner invokes each matching delegate after:

  • the manager's LoadPredefinedNodesAsync has populated PredefinedNodes;
  • the manager's CreateAddressSpaceAsync base has wired up the type tree and root notifiers;
  • (for FluentNodeManagerBase subclasses) the user's ConfigureAsync(builder, ct) / Configure(builder) wiring and the subsequent await builder.SealAsync(ct) are complete.

Configurator-type matching follows Type.IsAssignableFrom. A delegate targeting DiNodeManager runs against every Device Integration-derived manager (including PumpNodeManager); a delegate targeting PumpNodeManager will NOT run against a plain DiNodeManager.

Multiple ConfigureDevicesFor<T> calls accumulate and run in registration order. Exception semantics are fail-fast: any exception thrown by a configurator aborts hosted-server startup with a diagnostic that identifies the failing index and target type.

Context surface

The configurator receives an IDiPostSetupContext:

public interface IDiPostSetupContext
{
    DiNodeManager Manager { get; }
    CancellationToken CancellationToken { get; }
    T GetRequiredService<T>() where T : notnull;

    ValueTask<IDeviceBuilder<DeviceState>> CreateDeviceAsync(...);
    ValueTask<IDeviceBuilder<TDevice>> CreateDeviceAsync<TDevice>(...) where TDevice : ComponentState;
    IDeviceBuilder<TDevice> Device<TDevice>(NodeId nodeId) where TDevice : ComponentState;
    IDeviceBuilder<TDevice> DeviceByBrowseName<TDevice>(QualifiedName name, NodeState? parent = null)
        where TDevice : ComponentState;
    ITopologyElementBuilder<TElement> TopologyElement<TElement>(NodeId nodeId)
        where TElement : TopologyElementState;
    ITopologyElementBuilder<TElement> TopologyElementByBrowseName<TElement>(
        QualifiedName name,
        NodeState? parent = null)
        where TElement : TopologyElementState;
}

The context does not expose a raw IServiceProvider. Use GetRequiredService<T>() to resolve application services (intentionally narrow to discourage service-locator anti-patterns and lifetime traps).

Architecture

Component Lifetime Where
IDiPostSetupRunner Singleton (registered by AddOpcUaDi/ConfigureDevicesFor) Opc.Ua.Di.Server.Hosting
IDiPostSetupConfigurator Singleton (one per ConfigureDevicesFor call) Opc.Ua.Di.Server.Hosting
DiNodeManagerFactory / PumpNodeManagerFactory Singleton (.NET-DI-aware ctor injects runner) server / app
DiNodeManager / PumpNodeManager Per-server startup (factory passes runner) app

The runner is injected into the manager via the factory. The base DiNodeManager auto-invokes it at the end of its own CreateAddressSpaceAsync for every concrete subclass:

  • The base DiNodeManager.CreateAddressSpaceAsync calls LoadPredefinedNodesAsync → CreateFluentBuilder(...) → ConfigureAsync(builder, ct) → RegisterAuthoredNodesAsync → CompleteConfigureAsync → PostSetupRunner.RunAsync(this, ct) → SealConfigurationAsync(builder, ct) in that order. Sealing comes last because the fluent registries (simulations, event sources) are owned by the manager, not by a single builder, and sealing starts them — a post-setup configurator must still be able to register a simulation loop.
  • Subclasses (e.g. PumpNodeManager) override the protected virtual ValueTask ConfigureAsync(INodeManagerBuilder, CancellationToken) hook to materialise instances and drive the fluent INodeManagerBuilder. Because the hook is awaited, asynchronous setup and synchronous wiring live in one method; the base class owns node registration and sealing. The runner fires automatically once the builder is sealed — subclasses do not need to call PostSetupRunner.RunAsync themselves.
sequenceDiagram
    autonumber
    participant Host as Hosting / factory
    participant Base as DiNodeManager
    participant Sub as Subclass, e.g. PumpNodeManager
    participant B as NodeManagerBuilder
    participant Run as IDiPostSetupRunner

    Host->>Base: CreateAddressSpaceAsync(externalReferences, ct)
    Base->>Base: await LoadPredefinedNodesAsync
    Note over Base: predefined nodes loaded, type tree wired
    Base->>B: CreateFluentBuilder(InstanceNamespaceIndex)
    Note over B: attached to the manager's event-source<br/>and simulation registries

    Base->>Sub: await ConfigureAsync(builder, ct)
    Note over Sub: asynchronous setup and synchronous wiring<br/>in one awaited method

    Base->>Base: await RegisterAuthoredNodesAsync(builder, ct)
    Base->>Base: await CompleteConfigureAsync(externalReferences, ct)

    Base->>Run: await RunAsync(this, ct)
    Note over Run: configurators still register simulation<br/>loops and event sources here

    Base->>B: await SealConfigurationAsync(builder, ct)
    Note over B: drain staged root notifiers,<br/>then start the simulations

Sealing is the last step for a reason: the fluent registries belong to the manager rather than to one builder, and sealing starts them. Sealing before RunAsync would leave the post-setup configurators unable to register a simulation loop of their own.

Runtime conformance advertisement

DiNodeManager implements IConformanceContributor, so the hosted server publishes the DI facets and conformance units that are actually wired at startup. The server merges these contributions into Server/ServerCapabilities/ServerProfileArray and Server/ServerCapabilities/ConformanceUnits alongside the base server profiles.

The current gating is implementation-derived:

Runtime condition Server profile URI Conformance units
DI DeviceSet exists http://opcfoundation.org/UA-Profile/DI/Server/DeviceIntegrationHost DI DeviceTopology, DI Offline
A LockingServicesState has InitLock, RenewLock, or ExitLock wired http://opcfoundation.org/UA-Profile/DI/Server/Locking DI Locking
The same lock service also wires BreakLock same Locking profile DI BreakLocking
Any software-update loading mode is recorded http://opcfoundation.org/UA-Profile/DI/Server/SoftwareUpdateBase DI SU Software Update, DI SU PrepareForUpdate, DI SU Resume Update
SoftwareLoadingMode.Package http://opcfoundation.org/UA-Profile/DI/Server/FileSystemLoading DI SU FileSystem Loading, DI SU Installation for File System
SoftwareLoadingMode.Direct http://opcfoundation.org/UA-Profile/DI/Server/DirectLoading DI SU DirectLoading, DI SU UpdateStatus
SoftwareLoadingMode.Cached http://opcfoundation.org/UA-Profile/DI/Server/CachedLoading DI SU CachedLoading, DI SU Installation for Cached Loading, DI SU UpdateStatus

Client-side surface

Microsoft.Extensions.DependencyInjection.OpcUaClientDiBuilderExtensions adds a single extension method on IOpcUaClientBuilder:

IOpcUaClientBuilder AddOpcUaDi();

This registers four .NET-DI-friendly services that wrap the lazy ManagedSession accessor produced by AddClient(...):

  • IDiDiscoveryService — recursive device discovery from the Objects folder; streams DeviceEntry records as IAsyncEnumerable<DeviceEntry> so callers can begin processing before the browse completes.
  • Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>> — validates a device NodeId and returns a typed client.
  • Func<NodeId, CancellationToken, ValueTask<DiLockClient>> — client wrapper for LockingServicesType.InitLock / RenewLock / ExitLock / BreakLock.
  • Func<CancellationToken, ValueTask<DiTopologyClient>> — topology browser for the Device Integration well-known folders.
  • Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>> — software-version reader for a SoftwareUpdate instance.

Requires AddClient(...) to be called first — the extension throws InvalidOperationException if the managed-session accessor is missing when one of the factories is resolved.

Lock service

The lock service implements the OPC 10000-100 §10.5 locking facet. It tracks ownership of every TopologyElementType.Lock instance in the address space, enforces configurable timeouts, releases locks automatically when the owning session closes, and exposes the four spec-defined methods through the typed LockingServicesState proxy.

Components

Type Purpose
ILockService Application-facing facade: InitLock, RenewLock, ExitLock, BreakLock, GetState. Thread-safe.
LockState Snapshot record (Locked, LockingClient, LockingUser, RemainingLockTimeSeconds).
LockStatus OPC 10000-100 status-code constants.
DefaultLockService Default in-memory implementation backed by a ConcurrentDictionary.
LockingServicesExtensions.BindToLockService Wires the four generated *MethodState.OnCall handlers on a LockingServicesState instance through an ILockService.

Namespaces: Opc.Ua.Di.Server.Locking.

Status codes

Following OPC 10000-100 §10.5:

Constant Value Returned from
LockStatus.Ok 0 All methods (success)
LockStatus.AlreadyLocked 1 InitLock only
LockStatus.CouldNotLock 2 InitLock only
LockStatus.NotLocked 1 RenewLock / ExitLock / BreakLock
LockStatus.WrongClient 2 RenewLock / ExitLock

Default lock service

var lockService = new DefaultLockService(
    lockDuration: TimeSpan.FromMinutes(5),   // optional, defaults to 5 min
    timeProvider: TimeProvider.System);       // optional, for tests

// Hook session-close so locks held by a disconnecting session are
// released automatically.
lockService.AttachToSessionManager(server.SessionManager);

Lock ownership is keyed by ServerSystemContext.SessionId. When the service is invoked from a test (SystemContext rather than ServerSystemContext), it falls back to a synthetic session id derived from ISystemContext.UserId so unit tests can still distinguish callers.

Binding to a LockingServicesState

The Device Integration spec defines a Lock child on every TopologyElementType that implements four method invocations. Wire them through your service:

LockingServicesState lockNode = device.Lock!;
lockNode.BindToLockService(elementId: device.NodeId, service: lockService);

BindToLockService reads lockNode.InitLock, RenewLock, ExitLock, BreakLock and replaces their OnCall handlers with delegates that route into the ILockService. The elementId argument keys the service's internal dictionary — typically the topology element's own NodeId so two different devices can hold independent locks.

End-to-end flow

  1. Client calls InitLock(context: "tag") on a device's Lock.
  2. The method's OnCall runs the bound ILockService.InitLock, which checks the per-device record:
    • If unlocked / expired → record (SessionId, "tag", UserId, now + duration), return Ok (0).
    • If already locked by another session → return AlreadyLocked (1).
  3. RenewLock (same session) extends the expiry timestamp; from a different session it returns WrongClient (2).
  4. ExitLock removes the record (subject to ownership check).
  5. BreakLock removes the record regardless of ownership; intended for administrative recovery.
  6. If the owning session closes (server-emitted SessionClosing event), the DefaultLockService walks its records and releases anything that was held by that session.

Hosting

Register the service as a singleton through standard Microsoft.Extensions.DependencyInjection:

services.AddSingleton<ILockService, DefaultLockService>();

Then attach the session-close hook from inside a ConfigureDevicesFor<TNodeManager> configurator once the server's SessionManager is available:

.ConfigureDevicesFor<DiNodeManager>(ctx =>
{
    ILockService svc = ctx.GetRequiredService<ILockService>();
    if (svc is DefaultLockService defaultSvc)
    {
        defaultSvc.AttachToSessionManager(ctx.Manager.Server.SessionManager);
    }
    foreach (DeviceState device in ctx.Manager.PredefinedNodes
        .Values.OfType<DeviceState>())
    {
        device.Lock?.BindToLockService(device.NodeId, svc);
    }
});

Software update

The software-update facet implements OPC 10000-100 workflows for loading, preparation, installation, power cycle, and confirmation. Attach it with WithSoftwareUpdate; application handlers supply device-specific behavior. The SDK supplies the state-machine wiring and file-transfer infrastructure.

Server-side: package store

ISoftwarePackageStore stores package metadata and payloads. ISoftwareFolder maintains each device's Current / Previous / Future versions. Both have memory and file-system implementations. See Software Update storage abstractions for their contracts and persistence choices.

Surface

Use the package-store contract for operations, metadata, and stream ownership. The Software Update guide also owns WithSoftwareUpdate options and handler hooks.

FileSystemPackageStore layout

Use the store through ISoftwarePackageStore, rather than modifying its backing files directly. See file-system layout and provider composition for the file-system provider and persistence options.

Composing with IFileSystemProvider

Reuse the configured provider as described in provider composition.

Hosting

Register the package store with the host and attach it to the device's software-update facet. See the hosted-server walkthrough and package seeding example.

Client-side software update

SoftwareUpdateClient reads versions, uploads packages, and exposes typed state-machine operations. The usual workflow is upload, prepare, install, and confirm; supported steps depend on the device's advertised update capabilities. See uploading a package and typed state-machine operations for runnable call sequences.

The DI client integration registers Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>> through services.AddOpcUa().AddClient(...).AddOpcUaDi().

Client helpers

Beyond DiDeviceClient and DiDiscoveryClient, the Opc.Ua.Di.Client library ships three typed client wrappers that compose the standard OPC UA Session surface.

Helper Purpose
DiLockClient Wraps the four LockingServicesType methods.
DiTopologyClient Browses DeviceSet, NetworkSet, DeviceTopology.
SoftwareUpdateClient Reads the software-version property of a SoftwareUpdateType instance.

All three live in Opc.Ua.Di.Client and are registered automatically when applications call services.AddOpcUa().AddClient(...).AddOpcUaDi() on the client-side builder.

DiLockClient

public sealed class DiLockClient
{
    public DiLockClient(ISession session, NodeId lockNodeId, ITelemetryContext telemetry);
    public ValueTask<int> InitLockAsync(string context, CancellationToken ct = default);
    public ValueTask<int> RenewLockAsync(CancellationToken ct = default);
    public ValueTask<int> ExitLockAsync(CancellationToken ct = default);
    public ValueTask<int> BreakLockAsync(CancellationToken ct = default);
}

Each method invokes the corresponding LockingServicesType.{Method} generated NodeId on the server and returns the integer status code (see the LockStatus table for the OPC spec values).

The constructor takes the NodeId of the Lock instance — typically the device.Lock child, not the device itself. Resolve it via Session.TranslateBrowsePathsToNodeIdsAsync or by browsing the device's HasComponent references for a child named "Lock".

DiLockClient lockClient = new(session, lockNodeId, telemetry);
int status = await lockClient.InitLockAsync("client-tag");
if (status == LockStatus.Ok)
{
    try
    {
        // Do work that requires exclusive access.
    }
    finally
    {
        await lockClient.ExitLockAsync();
    }
}

DiTopologyClient

public sealed class DiTopologyClient
{
    public DiTopologyClient(ISession session, ITelemetryContext telemetry);
    public NodeId DeviceSetId { get; }
    public NodeId NetworkSetId { get; }
    public NodeId DeviceTopologyId { get; }

    public IAsyncEnumerable<TopologyEntry> EnumerateDevicesAsync(CancellationToken ct = default);
    public IAsyncEnumerable<TopologyEntry> EnumerateNetworksAsync(CancellationToken ct = default);
    public IAsyncEnumerable<TopologyEntry> EnumerateChildrenAsync(NodeId parentNodeId, CancellationToken ct = default);
}

public sealed record TopologyEntry(
    NodeId NodeId,
    string DisplayName,
    NodeId TypeDefinitionId,
    QualifiedName BrowseName);

EnumerateDevicesAsync and EnumerateNetworksAsync browse the hierarchical references of DeviceSet and NetworkSet and return the direct children that are Objects. EnumerateChildrenAsync provides the same surface for arbitrary nodes — useful when walking the DeviceTopology tree.

DiTopologyClient topology = new(session, telemetry);
await foreach (TopologyEntry device in topology.EnumerateDevicesAsync())
{
    Console.WriteLine($"{device.BrowseName}: {device.DisplayName}");
}

Hosting registration

When services.AddOpcUa().AddClient(o => { ... }).AddOpcUaDi() is called, the following factories are registered as singletons:

Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>>
Func<NodeId, CancellationToken, ValueTask<DiLockClient>>
Func<CancellationToken, ValueTask<DiTopologyClient>>
Func<NodeId, CancellationToken, ValueTask<SoftwareUpdateClient>>
IDiDiscoveryService

Inject the factory you need into your application services; the factory opens (or reuses) the lazy ManagedSession on first call.

public sealed class MyMonitor(
    Func<CancellationToken, ValueTask<DiTopologyClient>> topologyFactory,
    Func<NodeId, CancellationToken, ValueTask<DiDeviceClient>> deviceFactory,
    Func<NodeId, CancellationToken, ValueTask<DiLockClient>> lockFactory)
{
    public async Task ScanAsync(CancellationToken ct)
    {
        DiTopologyClient topo = await topologyFactory(ct);
        await foreach (TopologyEntry e in topo.EnumerateDevicesAsync(ct))
        {
            DiDeviceClient dev = await deviceFactory(e.NodeId, ct);
            DeviceIdentification id = await dev.ReadIdentificationAsync(ct);
            // ...
        }
    }
}

What is supported (OPC 10000-100)

References are to the OPC 10000-100 (DI v1.05) specification sections.

Foundation — nameplates and topology elements

  • TopologyElementType (§5.2) — abstract base exposed through ITopologyElementBuilder<TElement>.
  • IVendorNameplateType (§5.10) exposes Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, DeviceRevision, DeviceManual, DeviceClass, ProductInstanceUri, and ProductCode. Populate these properties with IDeviceBuilder.WithIdentification(...).
  • ITagNameplateType (§5.11) — AssetId, ComponentName, DeviceRevision. Populated by the same builder.
  • IDeviceHealthType (§5.12) — DeviceHealth enum plus the four NAMUR alarm references.
  • IAssetLocationIndicationType (§5.13) — StartLocationIndication / StopLocationIndication methods.
  • IOperationCounterType (§5.14) — PowerOnDuration, OperationDuration, EstimatedReturnedOperationDuration, EstimatedReturnedPowerOnDuration.

Device tree

  • ComponentType (§5.3) — abstract; materialised via IDeviceBuilder.
  • DeviceType (§5.4) — IDeviceBuilder.WithDeviceType<TDeviceState>(factory).
  • SoftwareType, BlockType, ConfigurableObjectType (§5.4 advanced sub-types) — IDeviceBuilder.AddSoftware, AddBlock, AddConfigurableObject.

Topology references

  • ConnectsTo (§5.6.2) — ITopologyElementBuilder.ConnectsTo(other).
  • ConnectsToParent (§5.6.3) — ITopologyElementBuilder.ConnectsToParent(other).
  • IsOnline (§5.6.4) — exposed for online-component wiring.
  • UpdateParent, CanUpdate (§5.6.5–§5.6.6) — used by software update.

Topology containers

  • DeviceSet (§6.2) — well-known instance, auto-created by DiNodeManager under ObjectsFolder; IDeviceBuilder parents devices here by default.
  • NetworkSet (§6.3) — well-known instance.
  • DeviceTopology (§6.4) — well-known instance; topology references attach here.
  • NetworkType, ConnectionPointType, ProtocolType (§6.5–§6.7).

Functional groups (§5.7)

All eight well-known Device Integration functional groups are exposed through typed methods on ITopologyElementBuilder; device builders inherit the same surface:

  • Identification, Configuration, Maintenance, Diagnostics, Statistics, Status, Operational, OperationCounters.

Custom groups go through WithFunctionalGroup(qualifiedName, action).

Lock service (§10.5)

  • LockingServicesType and four method types: InitLockMethodType, RenewLockMethodType, ExitLockMethodType, and BreakLockMethodType. ILockService and DefaultLockService wire these methods and provide session ownership, configurable timeouts, and cleanup when a session closes.

Software update (§10.3)

  • SoftwareUpdateType — orchestrates the loading + state-machine wiring.
  • SoftwareLoadingType, PackageLoadingType (§10.3.4) — abstract bases.
  • DirectLoadingType, CachedLoadingType, FileSystemLoadingType (§10.3.4) — the three loading variants.
  • SoftwareVersionType (§10.3.6) — Manufacturer, ProductInstanceUri, SoftwareRevision, PatchIdentifiers, ReleaseDate, ChangeLog, Hash.
  • Generated proxies for PrepareForUpdateStateMachineType (§10.3.7), InstallationStateMachineType (§10.3.8), PowerCycleStateMachineType (§10.3.9), and ConfirmationStateMachineType (§10.3.10), driven by the application.
  • Storage abstraction: ISoftwarePackageStore with MemoryPackageStore and FileSystemPackageStore implementations.

Support info & lifetime indication

  • ISupportInfoType (§5.15) — IDeviceBuilder.WithSupportInfo(configure). Backing folders DocumentationFiles / ImageSet / ProtocolSupport accept FileState / BaseObjectState children; file content commonly backed by IFileSystemProvider.
  • LifetimeVariableType + 6 indication sub-types (§10.6) — IDeviceBuilder.AddLifetimeIndication(kind, …). Classifier kinds: Time, NumberOfParts, NumberOfUsages, Length, Diameter, SubstanceVolume.

NAMUR alarms (§10.2)

  • DeviceHealthDiagnosticAlarmType (abstract) and the four concrete alarm types (FailureAlarmType, CheckFunctionAlarmType, OffSpecAlarmType, MaintenanceRequiredAlarmType) — generated proxies wired via the fluent IAlarmBuilder<TState> + ActivatesAlarm patterns from src/Opc.Ua.Server/Fluent.

DataTypes & VariableTypes

The Opc.Ua.Di model library includes these source-generated Device Integration DataTypes:

  • DeviceHealthEnumeration
  • SoftwareClass
  • LocationIndicationType
  • SoftwareVersionFileType
  • UpdateBehavior
  • FetchResultDataType
  • TransferResultErrorDataType
  • TransferResultDataDataType
  • ParameterResultDataType

Not yet implemented

  • TransferServicesType (§10.4) — parameter set transfer.