## Summary
### Documentation
- Stage the documentation index as a learning path: a first application,
independent client, server, and PubSub paths, then data and services,
companion models, production, advanced integration, and draft or
experimental capabilities.
- Add Getting started (repository samples or NuGet packages), OPC UA
concepts, Your first information model, and a production readiness
checklist.
- Add Native AOT application publishing, a first PubSub publisher and
subscriber exchange, and the UDP transport options.
- Add or expand contents navigation throughout `docs/`, and keep
contributor documentation separate.
- Correct outdated SDK examples and capability guidance, consolidate
repeated explanations into canonical guides, and repair local links and
heading structure.
- Rewrite What's New in 2.0 as a concise feature overview with short
linked details; keep migration instructions in the Migration Guide.
- Expand the feature catalogue with specification IDs, GDS, LDS, the OPC
10000-21 onboarding registrar, ISA-95, xRegistry, OpenUSD, and
sample-local models; distinguish draft status, explain crypto
pluggability, and bring performance guidance forward.
- Address review feedback on wording, active monitored items during
shadow reload, and the `Samples.md` filename and references.
- Regenerate the `opcua-v20-migration` plugin's bundled copy of the
migration guides so it matches the edited `docs/migrate/2.0.x` guides.
- Merge the latest `master`, preserving upstream resource-isolation
guidance within the task-based documentation index.
- Retain deferred Lingity findings where appropriate; this PR does not
claim that every document meets the Lingity score thresholds.
### Fixes found while verifying the guides
Each fix has regression tests that fail without it.
- **Client:** V2 subscriptions compared their lifetime with the
operation timeout instead of the session timeout, and logged a spurious
warning. `ISubscriptionEngineContext`, which is new in 2.0, gains a
`SessionTimeout` property; implementations must add it.
- **PubSub:** a subscriber now registers the `DataSetMetaData`
configured on its readers (OPC 10000-14 6.2.9.4), and the UADP decoder
decodes DataSetMessages that carry no ConfigurationVersion. Before, a
secured subscriber of the reference sample received no DataSets.
- **Source generator:** a ModelDesign method that declares its arguments
inline, without a method type, produced code that did not compile; it
now uses `MethodState`. The generated code of existing models is
unchanged.
- **MinimalClient sample:** waits for its first data-change notification
before it disconnects.
### Known issues, not addressed here
- UDP multicast: the publisher does not send on the interface that the
subscriber joins, and `MulticastLoopback` defaults to false. The PubSub
guide uses unicast for the exchange on one computer.
- The UDP metadata announcement is sent unsecured on secured writer
groups; a secured subscriber drops it with a warning.
- A server does not start in globalization-invariant mode, because
`ResourceManager` creates `CultureInfo("en-US")`. The Native AOT guide
cautions against the mode.
## Validation
- `git diff --check` and
`./.azurepipelines/validate-migration-plugin.ps1` (15 bundled migration
docs validated, plugin manifests synchronized).
- Local Markdown links, anchors, file-link casing, and contents lists
checked across all 87 documents under `docs/`. The index links every
top-level guide and every target of the previous index.
- Both Getting started routes, Your first information model, the PubSub
exchange, and the Native AOT publish of the Getting started client and
server were run as documented. The NuGet route and the tutorial use the
public `2.0.0-preview.5` packages.
- The changed libraries build for all target frameworks in Release
without warnings.
- Tests on .NET 10: Opc.Ua.SourceGeneration.Tests 199 passed;
Opc.Ua.SourceGeneration.Core.Tests 3,977 passed, 8 skipped;
Opc.Ua.Server.Tests `Fluent` category 621 passed; Opc.Ua.Client.Tests
subscription-engine tests 70 passed; Opc.Ua.PubSub.Tests 1,374 passed, 2
skipped; PubSub fuzz replay 145 passed. The new and affected tests also
pass on .NET Framework 4.8.
- Earlier merge validation: 174 resource-isolation tests passed on .NET
10.
- The full solution suite was not run locally.
Review and validation artifacts are maintained outside the repository.
---------
Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
23 KiB
Your first information model
This tutorial continues Route B of Getting started. You add a small information model to the server, give it behavior, and use it from the client. The model describes a room thermostat:
- A
ThermostatTypeobject type with a measuredTemperature, a writableSetpoint, and aBoostmethod that raises the setpoint. - A
Thermostatobject of that type in the server'sObjectsfolder.
The server accepts setpoints from 5 to 30 degrees Celsius. The client finds the thermostat by name, reads and writes its variables, and calls its method. It also shows how the server reports an operation that it rejects.
Contents
- Before you begin
- 1. Describe the model
- 2. Add the model to the server
- 3. Use the model from the client
- 4. Check the result
- What the code does
- Troubleshooting
- Next steps
Before you begin
Complete steps B1 to B4 of
Getting started.
This tutorial changes the GettingStartedServer and GettingStartedClient
projects from those steps. The applications keep their certificates and already
trust each other, so you do not repeat the trust steps.
The tutorial was verified with package version 2.0.0-preview.5, the version
that Route B installs.
If you ran only the repository samples, create the Route B projects first. The MinimalCalcServer sample uses the same server-side pattern as this tutorial.
1. Describe the model
A model file declares types and instances. At build time, the SDK source generator reads the file and generates C# code for it.
In the GettingStartedServer folder, create a Model folder and in it a file
named Heating.xml:
<?xml version="1.0" encoding="utf-8"?>
<opc:ModelDesign
xmlns:opc="http://opcfoundation.org/UA/ModelDesign.xsd"
xmlns:ua="http://opcfoundation.org/UA/"
xmlns="http://example.com/Heating/"
TargetNamespace="http://example.com/Heating/"
TargetXmlNamespace="http://example.com/Heating/Types.xsd"
TargetVersion="1.0.0"
TargetPublicationDate="2026-01-01T00:00:00Z">
<opc:Namespaces>
<opc:Namespace Name="Heating" Prefix="Heating"
XmlNamespace="http://example.com/Heating/Types.xsd"
XmlPrefix="Heating">http://example.com/Heating/</opc:Namespace>
<opc:Namespace Name="OpcUa" Prefix="Opc.Ua"
XmlNamespace="http://opcfoundation.org/UA/2008/02/Types.xsd"
XmlPrefix="OpcUa">http://opcfoundation.org/UA/</opc:Namespace>
</opc:Namespaces>
<opc:Method SymbolicName="BoostMethodType">
<opc:Description>Raises the setpoint and returns the new setpoint.</opc:Description>
<opc:InputArguments>
<opc:Argument Name="Degrees" DataType="ua:Double">
<opc:Description>The number of degrees to add to the setpoint.</opc:Description>
</opc:Argument>
</opc:InputArguments>
<opc:OutputArguments>
<opc:Argument Name="NewSetpoint" DataType="ua:Double" />
</opc:OutputArguments>
</opc:Method>
<opc:ObjectType SymbolicName="ThermostatType" BaseType="ua:BaseObjectType">
<opc:Description>A thermostat that controls the temperature of a room.</opc:Description>
<opc:Children>
<opc:Variable SymbolicName="Temperature" DataType="ua:Double"
AccessLevel="Read" ModellingRule="Mandatory">
<opc:Description>The measured temperature in degrees Celsius.</opc:Description>
</opc:Variable>
<opc:Variable SymbolicName="Setpoint" DataType="ua:Double"
AccessLevel="ReadWrite" ModellingRule="Mandatory">
<opc:Description>The target temperature in degrees Celsius, from 5 to 30.</opc:Description>
</opc:Variable>
<opc:Method SymbolicName="Boost" TypeDefinition="BoostMethodType"
ModellingRule="Mandatory" />
</opc:Children>
</opc:ObjectType>
<opc:Object SymbolicName="Thermostat" TypeDefinition="ThermostatType">
<opc:Description>The living-room thermostat.</opc:Description>
<opc:References>
<opc:Reference IsInverse="true">
<opc:ReferenceType>ua:Organizes</opc:ReferenceType>
<opc:TargetId>ua:ObjectsFolder</opc:TargetId>
</opc:Reference>
</opc:References>
</opc:Object>
</opc:ModelDesign>
| Part | Meaning |
|---|---|
TargetNamespace |
The namespace URI that identifies the model. When the server starts, it assigns each namespace URI a number, the namespace index. Clients look up the index by the URI. |
Prefix="Heating" |
The C# namespace of the generated code. |
BoostMethodType |
Declares the arguments of the Boost method: one Double input and one Double output. |
ThermostatType |
The object type. Every instance has the Mandatory children. AccessLevel decides whether clients can write a variable. |
Thermostat |
An instance of ThermostatType. The inverse Organizes reference places it in the Objects folder, where clients start browsing. |
The file uses the ModelDesign format, which is compact to write by hand. The generator also reads NodeSet2 files: the standard exchange format of modeling tools and companion specifications. See Source-generated node managers.
Declare method arguments in a method type such as
BoostMethodType, and reference it withTypeDefinition. With version2.0.0-preview.5, arguments declared on a method inside an object type produce code that does not compile.
2. Add the model to the server
Stop the server if it is still running from Getting started.
Generate the code
From the GettingStartedServer folder, add the source generator package. It
runs at build time and adds no assembly to your application.
dotnet add package OPCFoundation.NetStandard.Opc.Ua.SourceGeneration --prerelease
Open GettingStartedServer.csproj, and add the model file inside the
<Project> element:
<ItemGroup>
<AdditionalFiles Include="Model/Heating.xml" />
</ItemGroup>
Implement the behavior
Create HeatingNodeManager.cs in the GettingStartedServer folder:
using Opc.Ua;
using Opc.Ua.Server.Fluent;
namespace Heating;
[NodeManager(NamespaceUri = "http://example.com/Heating/")]
public partial class HeatingNodeManager
{
private const double MinimumSetpoint = 5.0;
private const double MaximumSetpoint = 30.0;
private readonly Lock m_lock = new();
private double m_setpoint = 21.0;
partial void Configure(IHeatingNodeManagerBuilder builder)
{
builder.Thermostat.Temperature
.PollEvery(TimeSpan.FromSeconds(1), SampleTemperature);
builder.Thermostat.Setpoint
.OnRead(ReadSetpoint)
.OnWrite(WriteSetpoint);
builder.Thermostat.Boost
.OnCall(Boost);
}
// Simulates a measurement within half a degree of the setpoint.
private double SampleTemperature()
{
return Math.Round(ReadSetpoint() - 0.5 + Random.Shared.NextDouble(), 1);
}
private double ReadSetpoint()
{
lock (m_lock)
{
return m_setpoint;
}
}
private void WriteSetpoint(double value)
{
CheckSetpoint(value);
lock (m_lock)
{
m_setpoint = value;
}
}
private double Boost(double degrees)
{
lock (m_lock)
{
double newSetpoint = m_setpoint + degrees;
CheckSetpoint(newSetpoint);
m_setpoint = newSetpoint;
return newSetpoint;
}
}
// The client receives the status code of an exception that a callback throws.
private static void CheckSetpoint(double setpoint)
{
if (setpoint is not (>= MinimumSetpoint and <= MaximumSetpoint))
{
throw new ServiceResultException(
StatusCodes.BadOutOfRange,
$"The setpoint must be from {MinimumSetpoint} to {MaximumSetpoint}.");
}
}
}
The [NodeManager] attribute asks the generator to complete this partial class.
The generated part loads the model's nodes into the server's address space. The
generator also creates a HeatingNodeManagerFactory class and an
IHeatingNodeManagerBuilder interface. Set NamespaceUri to the model's
namespace URI as a string literal. The generated constant for it,
Heating.Namespaces.Heating, cannot be used here, because the attribute is read
before that constant is generated.
In Configure, the builder has a property for each node of the model:
builder.Thermostat.Setpoint is the Setpoint variable of the Thermostat
object. A misspelled name is a compile error. The callbacks connect the nodes to
the state that the node manager holds:
PollEverysamplesTemperatureevery second and updates the node when the value changes. Reads return the latest sample, and subscriptions receive each change.OnReadandOnWritehandle each read and write ofSetpoint. A value that is returned only by anOnReadcallback does not reach subscriptions; see pushing value changes to subscribers.OnCallreceives the method's input as adoubleand returns its output.
To reject an operation, throw a ServiceResultException with a Bad status code.
The server returns that status code to the client. The server checks some rules
itself before it calls your callback: it rejects a value of the wrong data type
and a write to the read-only Temperature.
The server runs callbacks for several requests at the same time, and PollEvery
runs in the background, so a lock guards the setpoint.
Register the node manager
Replace the contents of Program.cs:
using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Hosting;
HostApplicationBuilder builder = Host.CreateApplicationBuilder(args);
builder.Services
.AddOpcUa()
.AddServer(options =>
{
options.ApplicationName = "GettingStartedServer";
options.ApplicationUri = "urn:localhost:GettingStartedServer";
options.ProductUri = "urn:example.com:GettingStartedServer";
options.EndpointUrls.Add("opc.tcp://localhost:62560/GettingStartedServer");
options.PkiRoot = Path.Combine(builder.Environment.ContentRootPath, "pki");
})
.AddNodeManager<Heating.HeatingNodeManagerFactory>();
await builder.Build().RunAsync();
Only the AddNodeManager line is new. It adds the generated factory, which
creates the node manager when the server starts.
Start the server:
dotnet run
The server is ready when it logs:
OPC UA server listening at opc.tcp://localhost:62560/GettingStartedServer.
Leave the server running.
3. Use the model from the client
Share the model
The client generates code from the same model file: constants for the namespace
URI and the browse names, and a typed client for ThermostatType.
In the second terminal, from the GettingStartedClient folder, add the source
generator package:
dotnet add package OPCFoundation.NetStandard.Opc.Ua.SourceGeneration --prerelease
Open GettingStartedClient.csproj, and add the following inside the <Project>
element:
<PropertyGroup>
<ModelSourceGeneratorOmitFluentApi>true</ModelSourceGeneratorOmitFluentApi>
</PropertyGroup>
<ItemGroup>
<AdditionalFiles Include="../GettingStartedServer/Model/Heating.xml" />
</ItemGroup>
ModelSourceGeneratorOmitFluentApi turns off the server-side helpers, which
need the server package.
Replace the client code
Replace the contents of Program.cs:
using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Hosting;
using Microsoft.Extensions.Logging;
using Opc.Ua;
using Opc.Ua.Client;
HostApplicationBuilder builder = Host.CreateApplicationBuilder(args);
builder.Logging.SetMinimumLevel(LogLevel.Warning);
builder.Services
.AddOpcUa()
.AddClient(options =>
{
options.ApplicationName = "GettingStartedClient";
options.ApplicationUri = "urn:localhost:GettingStartedClient";
options.ProductUri = "urn:example.com:GettingStartedClient";
options.PkiRoot = Path.Combine(builder.Environment.ContentRootPath, "pki");
options.Session = new ManagedSessionOptions
{
ReconnectPolicy = new ReconnectPolicyOptions { MaxRetries = 2 },
};
})
.AddDiscoveryAndConnect(options =>
{
options.DiscoveryUrl = "opc.tcp://localhost:62560/GettingStartedServer";
options.SecurityMode = MessageSecurityMode.SignAndEncrypt;
options.SecurityPolicyUri = SecurityPolicies.Basic256Sha256;
});
using IHost host = builder.Build();
await host.StartAsync();
using var timeout = new CancellationTokenSource(TimeSpan.FromMinutes(1));
CancellationToken ct = timeout.Token;
try
{
var connect = host.Services
.GetRequiredService<Func<CancellationToken, Task<ManagedSession>>>();
ManagedSession session = await connect(ct);
await using (session)
{
// The server assigns the namespace index at run time. Look it up
// from the namespace URI that the model defines.
int namespaceIndex = session.NamespaceUris.GetIndex(Heating.Namespaces.Heating);
if (namespaceIndex < 0)
{
throw new ServiceResultException(
StatusCodes.BadNotFound,
"The server does not expose the Heating model.");
}
var ns = (ushort)namespaceIndex;
Console.WriteLine($"Heating namespace index: {ns}");
// Translate three browse paths, starting at the Objects folder, in one request.
TranslateBrowsePathsToNodeIdsResponse translated =
await session.TranslateBrowsePathsToNodeIdsAsync(
null,
[
PathFromObjects(ns, Heating.BrowseNames.Thermostat),
PathFromObjects(ns, Heating.BrowseNames.Thermostat,
Heating.BrowseNames.Temperature),
PathFromObjects(ns, Heating.BrowseNames.Thermostat,
Heating.BrowseNames.Setpoint),
],
ct);
NodeId thermostatId = GetTarget(session, translated.Results[0]);
NodeId temperatureId = GetTarget(session, translated.Results[1]);
NodeId setpointId = GetTarget(session, translated.Results[2]);
// Read both variables in one request. Each value has its own status.
(ArrayOf<DataValue> values, ArrayOf<ServiceResult> errors) =
await session.ReadValuesAsync([temperatureId, setpointId], ct);
PrintValue("Temperature", values[0], errors[0]);
PrintValue("Setpoint", values[1], errors[1]);
// Write a valid setpoint, then one outside the range the server accepts.
foreach (double setpoint in new[] { 22.5, 35.0 })
{
WriteResponse response = await session.WriteAsync(
null,
[
new WriteValue
{
NodeId = setpointId,
AttributeId = Attributes.Value,
Value = new DataValue(new Variant(setpoint)),
},
],
ct);
// The Write service succeeds as a whole; each write has its own result.
Console.WriteLine($"Write Setpoint {setpoint}: {response.Results[0]}");
}
// Call the Boost method through the client generated from the model.
var thermostat = new Heating.ThermostatTypeClient(
session,
thermostatId,
host.Services.GetRequiredService<ITelemetryContext>());
double newSetpoint = await thermostat.BoostAsync(2.0, ct);
Console.WriteLine($"Boost 2: new setpoint {newSetpoint}");
try
{
await thermostat.BoostAsync(10.0, ct);
}
catch (ServiceResultException ex)
{
Console.WriteLine($"Boost 10: {ex.StatusCode}");
}
}
}
catch (ServiceResultException ex)
{
Console.Error.WriteLine($"OPC UA error {ex.StatusCode}: {ex.Message}");
Environment.ExitCode = 1;
}
catch (OperationCanceledException)
{
Console.Error.WriteLine("The client did not finish within one minute.");
Environment.ExitCode = 1;
}
finally
{
await host.StopAsync();
}
static BrowsePath PathFromObjects(ushort ns, params string[] browseNames)
{
return new BrowsePath
{
StartingNode = ObjectIds.ObjectsFolder,
RelativePath = new RelativePath
{
Elements = browseNames
.Select(name => new RelativePathElement
{
ReferenceTypeId = ReferenceTypeIds.HierarchicalReferences,
IncludeSubtypes = true,
TargetName = new QualifiedName(name, ns),
})
.ToArray(),
},
};
}
static NodeId GetTarget(ManagedSession session, BrowsePathResult result)
{
if (StatusCode.IsBad(result.StatusCode) || result.Targets.Count == 0)
{
throw new ServiceResultException(
result.StatusCode,
"A browse path was not found.");
}
return ExpandedNodeId.ToNodeId(result.Targets[0].TargetId, session.NamespaceUris);
}
static void PrintValue(string name, DataValue value, ServiceResult error)
{
if (ServiceResult.IsBad(error) || StatusCode.IsBad(value.StatusCode))
{
Console.WriteLine($"{name}: failed with {value.StatusCode}");
}
else if (value.WrappedValue.TryGetValue(out double number))
{
Console.WriteLine($"{name}: {number} ({value.StatusCode})");
}
else
{
Console.WriteLine($"{name}: unexpected value {value.WrappedValue}");
}
}
4. Check the result
Run the client:
dotnet run
The client prints output like this and exits with exit code 0:
Heating namespace index: 2
Temperature: 21.1 (Good [0x00000000])
Setpoint: 21 (Good [0x00000000])
Write Setpoint 22.5: Good [0x00000000]
Write Setpoint 35: BadOutOfRange [0x803C0000]
Boost 2: new setpoint 24.5
Boost 10: BadOutOfRange [0x803C0000]
The temperature varies, and the number format follows your system's culture. The server rejects the setpoint 35 and the boost to 34.5, because both are above 30.
The server keeps its state between client runs: if you run the client again, the setpoint starts at 24.5. Restart the server to start again from 21. When you are done, press Ctrl+C in the server terminal.
What the code does
| Step | Code | Learn more |
|---|---|---|
| Find the namespace | session.NamespaceUris.GetIndex(Heating.Namespaces.Heating) returns the index that this server assigned to the model's namespace URI. Heating.Namespaces.Heating is a generated constant. Do not hard-code namespace indexes: they can differ between servers. |
Concepts: node identity and namespaces |
| Find the nodes | TranslateBrowsePathsToNodeIdsAsync follows browse names from the Objects folder. It returns the NodeId of each path, or a Bad status such as BadNoMatch. The server chooses the NodeIds of instances; browse paths are the same on every server that implements the model. |
Concepts: the address space |
| Read | ReadValuesAsync reads several values in one request, and returns a DataValue and a ServiceResult for each. |
Concepts: values, status codes, and timestamps |
| Write | WriteAsync returns one status code for each value in the request. The request succeeds even when the server rejects a value. The value must have the variable's data type: 22.0 is a Double, but 22 is an Int32, which fails with BadTypeMismatch. |
Concepts: service results and errors |
| Call | ThermostatTypeClient is generated from ThermostatType. Its BoostAsync method calls Boost with typed arguments, and throws a ServiceResultException when the call fails. |
Methods with arguments (server side) |
| Implement nodes | The generated typed builder attaches PollEvery, OnRead, OnWrite, and OnCall callbacks to the model's nodes. |
Typed model traversal |
Troubleshooting
| Symptom | Cause | What to do |
|---|---|---|
The client build fails with error CS0234: The type or namespace name 'Server' does not exist in the namespace 'Opc.Ua'. |
The generator creates server-side helpers, which need the server package. | Set ModelSourceGeneratorOmitFluentApi to true in the client project. |
The server build fails with error CS0234: The type or namespace name 'BoostMethodState' does not exist in the namespace 'Heating'. |
With 2.0.0-preview.5, the model declares the method arguments on the method inside ThermostatType. |
Declare the arguments in a method type, as in step 1. |
The server build fails with error MODELGEN035: The NamespaceUri expression ... could not be resolved during source generation. |
[NodeManager] uses a generated constant, such as Namespaces.Heating. |
Use the namespace URI as a string literal. |
The server does not expose the Heating model. |
The server does not register the node manager, or the model uses another namespace URI. | Check the AddNodeManager call in the server, and the TargetNamespace in the model. |
OPC UA error BadNoMatch [0x806F0000]: A browse path was not found. |
A browse name in the client does not match the model. Browse names are case-sensitive. | Use the generated Heating.BrowseNames constants. |
A write fails with BadTypeMismatch. |
The value's data type differs from the variable's data type. | Write a Double, such as 22.0. |
BadSecurityChecksFailed or BadCertificateUntrusted |
The applications do not trust each other. | Repeat step B3 of Getting started. |
Next steps
- Monitor the temperature: pass
temperatureIdtoSubscribeDataChangesAsync, as the Getting started client does for the server clock. See Subscriptions. - Learn more about generated node managers: NodeSet2 models, instances created at run time, events, and alarms. See Source-generated node managers.
- Load models into a running server without generated code. See Runtime NodeSets.
- Define your own structures. See Source-generated data types.
- Use a standard model, such as Device Integration. See Use companion models.
- Before you deploy, work through the production readiness checklist.