mirror of
https://github.com/OPCFoundation/UA-.NETStandard.git
synced 2026-10-23 10:23:13 +08:00
ca89ac85a7
# Description Adds a **Generators companion-specification sample** alongside the existing pump sample, and a **`SiteCompositionServer`** that composes several device servers into one OpenUSD scene at a supervisory level — demonstrating that servers can be aggregated without mirroring their address spaces. Three things, in dependency order: ### 1. `GeneratorServer` A self-contained server realising the draft Generators spec (`http://opcfoundation.org/UA/Generators/`) end to end: N simulated generating sets, DI + Machinery integration, a twelve-state operating state machine, four protection alarms per set, six control methods, and a per-set OpenUSD twin. The organising idea is that **load fraction is the only independent variable**. Everything else is a function of it: ``` V̇_f(x) = 3.67 + 100·x fuel rate [L/h] η(x) = P(x) / (V̇_f(x) · ρ · LHV) efficiency S = P / PF I = S / (√3·V_LL) f = N·p / 120 ``` This is not stylistic. When each measurement is an independent oscillator — as the pump sample's simulation once was — a server happily publishes a duty point no real machine could occupy, and no test can catch it because there is nothing for the values to be inconsistent *with*. Deriving them from one variable means `P = √3·V·I·PF` and `η = P/(V̇·ρ·LHV)` hold at every tick by construction. The published `DATASHEET.md`, the engineering ranges, the trip points and the simulation all read the same constants in `GeneratorDatasheet.cs`, so the document and the server cannot describe different machines. The machine is a fictitious **SimGen Systems GenX-500** (400 kW prime / 440 kW standby, 400/230 V, 50 Hz, four-pole). Figures are representative of a real industrial genset class; no vendor is named anywhere in the code or docs. ### 2. Cross-server composition in the connector `RemoteSessionFactory` already existed in the client library but the connector CLI never set it, so cross-server composition was unreachable. `--federate` wires it up: the connector opens a session to each server named by a component binding, discovers its representations and drives its bindings into the same stage. It is **opt-in** because the endpoint the connector dials comes from the server being rendered rather than from the operator, which makes honouring it a trust decision. Federation is best-effort per component — a subordinate that is down is logged and skipped, and the rest of the scene still renders — which is the only `src/` change in this PR. ### 3. `SiteCompositionServer` Owns no devices. It publishes a site stage plus one cross-server component binding per subordinate, carrying that server's `ComponentServerUri` and `ComponentEndpointUrl`. Nothing is mirrored, so there is no cache to invalidate and no second copy of the truth. ## Notes for reviewers **Everything interesting in this PR was found by running the servers, not by reading the code.** Six defects, none of which looked wrong in review: - `IsShutdown` and `SubsystemName` are *optional* on `GeneratorProtectionAlarmType`, so the generated factory does not materialise them. `CreateOrReplace` alone produces a child that exists, appears in `GetChildren` and holds the right value — but carries **no `ReferenceTypeId`**, so no browse can reach it. Every alarm was publishing its trip without saying whether the trip stops the machine or which subsystem to go to. `AddXxx(context)` first is what gives the child its `HasProperty` reference. - **The protections could never fire.** Every trip point sits outside the band the datasheet curves produce — that is what a datasheet *means* — so all four alarms, the shutdown class, `ResetFaults` and the whole `Fault` branch of the state machine were unreachable while the README documented them as observable. Overload was worse: the load clamp ceiling was set to exactly the trip point, making a strictly-greater-than comparison unsatisfiable. Faults are now injectable, and the first set — the one the hero camera frames — develops one on a slow rotation. - **A shutdown trip removes the condition that caused it**, because oil pressure and coolant temperature are only supervised while the engine turns. Each alarm went active for one tick and cleared, leaving an operator with a stopped machine and no indication of why. Shutdown-class alarms now latch until the set leaves the shutdown state. Every unit test that checked the *condition* passed throughout — the defect only appears when the trip and the supervision interact over time. - **`Synchronizing` and `Paralleled` were declared, drawn in the README and never entered.** The first set now energises a dead bus and closes onto it while every other set synchronises to a live one — both how a real plant parallels, and what makes the two states observable. - **The tick raced client method calls.** The simulation tick runs on a thread-pool thread while method calls arrive on request threads, and both transition sets and write the same nodes. A tick moving a set to `Cooldown` and a concurrent `EmergencyStop` could interleave the paired `CurrentState` / `CurrentState.Id` writes and leave a client with a state *name* from one transition and a state *node* from the other — the exact failure the paired write exists to prevent, reintroduced by the threading model. Both paths now take one gate. - Low oil pressure supervised from raw speed **tripped every set during cranking**, because pressure has not built yet. Now gated on `IsSpinning`, which is what a real start-up bypass does. Smaller fixes: shutdown trips are applied after the whole evaluation pass (stopping mid-loop made the remaining conditions read healthy, collapsing simultaneous trips to whichever came first in the table); `ResetFaults` reports its clears as events (a client learns of condition state changes only through events, so a silent clear leaves an alarm-list client showing it forever); the start counter moved into the transition so commanded starts are counted; the federated connector closes the remote session if the connector constructor throws between taking ownership and registering it; and `prepare_machinery_nodeset.py` now *asserts* the IA namespace is last before removing it rather than only claiming so in its docstring — removing any earlier entry would silently renumber every namespace after it and rebind their NodeIds. **A model limitation is left visible rather than papered over.** `GeneratorStateMachineType` declares an emergency stop only out of `Running`, `Loaded` and `Paralleled`, so the sample refuses `EmergencyStop` from `Starting` and `Warmup`. A real panel stops from anywhere. That is the specification's shape, not this sample's choice, so it is pinned by a test and named in the docs. **`Model/` vendors a reduced Machinery nodeset**, derived mechanically by whitelist. The full official nodeset does not survive the model source generator (`MODELGEN003`) and drags in IA through a single optional `Stacklight` member a generating set does not have. Deriving it by script keeps the provenance checkable; the whitelist is the only thing to edit when more types are needed. **Never hand-edit the generated output.** **The federated scene renders end to end.** Getting there surfaced three more defects, all of which produced a plausible-looking scene with nothing in it: the generator sample's plant aggregation was created under an already-registered `DeviceSet` and so was invisible to every client (it had *never* rendered geometry, standalone or federated); the connector's asset fetch ran on the primary session only, so composition referenced layers that were never downloaded; and both generator colour bindings wrote `primvars:displayColor` to prims that did not declare it, so the renderer rejected every update while the file still looked correct. Cross-server components compose under the subordinate's own root, so the site layer now *places* `/Plant` and `/Powerhouse` rather than leaving them stacked on the origin. **`OpenUsdRepresentation` is now mounted with `HasAddIn`, not `HasComponent`** (review feedback). The nodeset says so explicitly — *"Mounted with HasAddIn"* — but every server in the tree used plain `HasComponent`. It survived because `HasAddIn` is a *subtype* of `HasComponent`: the representation still browses, still aggregates and still drives a twin, so every functional test passed before the fix and after it, and only a conformance checker could tell. Seven mount sites corrected. `PumpDeviceIntegrationServer` and `MinimalRobotServer` had hand-rolled the mount instead of calling the shared `CreateRepresentation` helper, which is exactly how they drifted from it. Both sample E2E suites now assert the reference type across **every** discovered representation — a narrower check would have missed the plant-level representation that arrived later from master still carrying `HasComponent`. **Live colour is not achievable in the current OpenUSD viewer, and that is now documented rather than worked around.** Proven with a standalone probe: `primvars:displayColor` resolves as `color3f[]` from the `UsdGeomGprim` schema whatever the layer declares, and the `OpenUsd 0.4.0-alpha` managed API has no writer for that type. Bound `UsdPreviewSurface` materials are not shaded either, so geometry renders grey unless it also carries an explicit `displayColor` primvar. The **visibility** bindings carry no such caveat and are what the samples rely on to show state. Filed upstream as [openusd-dotnet#2](https://github.com/marcschier/openusd-dotnet/issues/2), [#3](https://github.com/marcschier/openusd-dotnet/issues/3) and [#4](https://github.com/marcschier/openusd-dotnet/issues/4), and linked from `docs/OpenUsd.md` so a reader can check whether they have since been fixed. ## Related Issues No tracking issue — this is additive sample and documentation work with a single small, self-contained change to `src/` (per-component error isolation and session-ownership hardening in `OpenUsdConnector.Composition.cs`). Happy to open one if maintainers would prefer it tracked. ## Checklist - [x] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [x] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. ### Testing The generator fixtures live in `tests/Opc.Ua.OpenUsd.Tests/Generator` — **82 tests**, no new project. `Opc.Ua.Di.Tests` would have been the natural home next to the pump fixtures, but both device samples source-generate their own reduced `Opc.Ua.Machinery` model and expose it via `InternalsVisibleTo`, so referencing both from one assembly makes every Machinery type ambiguous (CS0433); `Opc.Ua.OpenUsd.Tests` references no other sample and already hosts `RobotAssetContractTests`. The suite runs **870** on net10.0 and net48 (784 existing + 86) and **788** on net472, where the sample does not exist and only the framework-independent asset-contract tests run — forgetting exactly that exclusion broke CI on the sibling pump PR. The tests target the things in this sample that fail *quietly*: - **Datasheet conformance** holds the model to its own claim — rated speed is `120·f/p`, rated current follows from the rating, the fuel curve reproduces the published table, and `η = P/(V̇·ρ·LHV)` reconciles at every load. Efficiency is swept across the whole simulated range to show it stays inside (0,100) and rises monotonically; a fit that goes negative somewhere in its range is a coincidence that happens to look right at the duty point, not a model. A further test reads `DATASHEET.md` and checks the document quotes the figures the server actually serves. - **Drift between the two descriptions of the state machine** — the physics' `IsLegalTransition` and the model's `GeneratorStateMap` — is checked in *both* directions. A transition the physics permits but the map lacks moves a machine without telling a client; one the map holds but the physics refuses is dead weight that looks supported. - **Reachability at run time**, not just in the declared table — the test that catches states the model declares and nothing ever enters. - **That every protection can actually fire**, which is the half of the alarm contract that "a healthy set annunciates nothing" does not cover. A **hosted end-to-end fixture** connects a real client and asserts what the address space actually exposes — the aggregation at `/Powerhouse/Generators`, its component binding, and every per-set twin. That is the only kind of test that catches the registration defect above: the node object had the right browse name, binding and asset reference, so every test that inspected objects passed while no client could see it. **Every state-machine and protection fix was checked by mutation.** Restoring the clamp ceiling, the direct `Running → Loaded` path, the old start-counter placement, or removing the alarm opt-in each makes the corresponding test fail, naming the specific defect. A test that has never been seen to fail has not been shown to work. Verified against a running plant: `Synchronizing`, `Paralleled` and `Fault` all observed on a two-set server, with `HighCoolantTemperatureAlarm` seen active on the fault subject. Method behaviour verified separately — per-set distinct `CurrentState` nodes, `EmergencyStop` → `EmergencyStopped` with `Start` then refused as `BadInvalidState`, `ResetFaults` → `Off`, `SetOperatingMode(9999)` refused with the mode unchanged, and the other sets untouched throughout. Also verified as a three-server federated stage. 0 warnings on a clean Release rebuild of both samples, the client library, the connector and the tests, across every TFM. --------- Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com> Copilot-Session: fe608993-f3c9-4779-a6b9-9a9eabfc24ba
12 KiB
12 KiB
| 1 | Machines | 1001 | Object |
|---|---|---|---|
| 2 | MachineryItemState_StateMachineType | 1002 | ObjectType |
| 3 | IMachineryItemVendorNameplateType | 1003 | ObjectType |
| 4 | MachineryItemIdentificationType | 1004 | ObjectType |
| 5 | MachineryComponentIdentificationType | 1005 | ObjectType |
| 6 | MachineComponentsType | 1006 | ObjectType |
| 7 | IMachineryEquipmentType | 1007 | ObjectType |
| 8 | MachineryOperationModeStateMachineType | 1008 | ObjectType |
| 9 | MachineryOperationCounterType | 1009 | ObjectType |
| 10 | IMachineVendorNameplateType | 1010 | ObjectType |
| 11 | IMachineTagNameplateType | 1011 | ObjectType |
| 12 | MachineIdentificationType | 1012 | ObjectType |
| 13 | MachineryEquipmentFolderType | 1013 | ObjectType |
| 14 | MonitoringType | 1014 | ObjectType |
| 15 | MachineryLifetimeCounterType | 1015 | ObjectType |
| 16 | NotificationsType | 1017 | ObjectType |
| 17 | Server_Namespaces_http___opcfoundation_org_UA_Machinery_ | 5001 | Object |
| 18 | MachineComponentsType_Component | 5002 | Object |
| 19 | MachineComponentsType_Component_Identification | 5003 | Object |
| 20 | MachineryItemState_StateMachineType_OutOfService | 5004 | Object |
| 21 | MachineryItemState_StateMachineType_NotAvailable | 5005 | Object |
| 22 | MachineryItemState_StateMachineType_Executing | 5006 | Object |
| 23 | MachineryItemState_StateMachineType_NotExecuting | 5007 | Object |
| 24 | MachineryItemState_StateMachineType_FromNotAvailableToOutOfService | 5008 | Object |
| 25 | MachineryItemState_StateMachineType_FromNotAvailableToNotExecuting | 5009 | Object |
| 26 | MachineryItemState_StateMachineType_FromNotAvailableToExecuting | 5010 | Object |
| 27 | MachineryItemState_StateMachineType_FromNotAvailableToNotAvailable | 5011 | Object |
| 28 | MachineryItemState_StateMachineType_FromOutOfServiceToNotAvailable | 5012 | Object |
| 29 | MachineryItemState_StateMachineType_FromOutOfServiceToNotExecuting | 5013 | Object |
| 30 | MachineryItemState_StateMachineType_FromOutOfServiceToExecuting | 5014 | Object |
| 31 | MachineryItemState_StateMachineType_FromOutOfServiceToOutOfService | 5015 | Object |
| 32 | MachineryItemState_StateMachineType_FromNotExecutingToNotAvailable | 5016 | Object |
| 33 | MachineryItemState_StateMachineType_FromNotExecutingToOutOfService | 5017 | Object |
| 34 | MachineryItemState_StateMachineType_FromNotExecutingToExecuting | 5018 | Object |
| 35 | MachineryItemState_StateMachineType_FromNotExecutingToNotExecuting | 5019 | Object |
| 36 | MachineryItemState_StateMachineType_FromExecutingToNotAvailable | 5020 | Object |
| 37 | MachineryItemState_StateMachineType_FromExecutingToOutOfService | 5021 | Object |
| 38 | MachineryItemState_StateMachineType_FromExecutingToNotExecuting | 5022 | Object |
| 39 | MachineryItemState_StateMachineType_FromExecutingToExecuting | 5023 | Object |
| 40 | MachineryOperationModeStateMachineType_None | 5024 | Object |
| 41 | MachineryOperationModeStateMachineType_Maintenance | 5025 | Object |
| 42 | MachineryOperationModeStateMachineType_Processing | 5026 | Object |
| 43 | MachineryOperationModeStateMachineType_Setup | 5027 | Object |
| 44 | MachineryOperationModeStateMachineType_FromNoneToMaintenance | 5028 | Object |
| 45 | MachineryOperationModeStateMachineType_FromNoneToSetup | 5029 | Object |
| 46 | MachineryOperationModeStateMachineType_FromNoneToProcessing | 5030 | Object |
| 47 | MachineryOperationModeStateMachineType_FromNoneToNone | 5031 | Object |
| 48 | MachineryOperationModeStateMachineType_FromMaintenanceToNone | 5032 | Object |
| 49 | MachineryOperationModeStateMachineType_FromMaintenanceToSetup | 5033 | Object |
| 50 | MachineryOperationModeStateMachineType_FromMaintenanceToProcessing | 5034 | Object |
| 51 | MachineryOperationModeStateMachineType_FromMaintenanceToMaintenance | 5035 | Object |
| 52 | MachineryOperationModeStateMachineType_FromSetupToNone | 5036 | Object |
| 53 | MachineryOperationModeStateMachineType_FromSetupToMaintenance | 5037 | Object |
| 54 | MachineryOperationModeStateMachineType_FromSetupToProcessing | 5038 | Object |
| 55 | MachineryOperationModeStateMachineType_FromSetupToSetup | 5039 | Object |
| 56 | MachineryOperationModeStateMachineType_FromProcessingToNone | 5040 | Object |
| 57 | MachineryOperationModeStateMachineType_FromProcessingToMaintenance | 5041 | Object |
| 58 | MachineryOperationModeStateMachineType_FromProcessingToSetup | 5042 | Object |
| 59 | MachineryOperationModeStateMachineType_FromProcessingToProcessing | 5043 | Object |
| 60 | MonitoringType_Status | 5044 | Object |
| 61 | MonitoringType_Health | 5045 | Object |
| 62 | MonitoringType_Process | 5046 | Object |
| 63 | MonitoringType_Consumption | 5047 | Object |
| 64 | MonitoringType_Status_MachineryItemState | 5048 | Object |
| 65 | MonitoringType_Status_MachineryOperationMode | 5049 | Object |
| 66 | MonitoringType_Status_Stacklight | 5050 | Object |
| 67 | MonitoringType_Health_DeviceHealthAlarms | 5051 | Object |
| 68 | MachineryEquipmentFolderType_MachineryEquipment | 5052 | Object |
| 69 | MachineryItemIdentificationType_ProductInstanceUri | 6001 | Variable |
| 70 | MachineryItemIdentificationType_Manufacturer | 6002 | Variable |
| 71 | MachineryItemIdentificationType_SerialNumber | 6003 | Variable |
| 72 | MachineryItemIdentificationType_YearOfConstruction | 6004 | Variable |
| 73 | MachineryItemIdentificationType_MonthOfConstruction | 6005 | Variable |
| 74 | MachineryItemIdentificationType_InitialOperationDate | 6006 | Variable |
| 75 | MachineryItemIdentificationType_ManufacturerUri | 6007 | Variable |
| 76 | MachineryItemIdentificationType_Model | 6008 | Variable |
| 77 | MachineryItemIdentificationType_ProductCode | 6009 | Variable |
| 78 | MachineryItemIdentificationType_HardwareRevision | 6010 | Variable |
| 79 | MachineryItemIdentificationType_SoftwareRevision | 6011 | Variable |
| 80 | MachineryItemIdentificationType_DeviceClass | 6012 | Variable |
| 81 | MachineryItemIdentificationType_AssetId | 6013 | Variable |
| 82 | MachineryItemIdentificationType_ComponentName | 6014 | Variable |
| 83 | MachineIdentificationType_ProductInstanceUri | 6015 | Variable |
| 84 | MachineryComponentIdentificationType_DefaultInstanceBrowseName | 6016 | Variable |
| 85 | MachineryComponentIdentificationType_DeviceRevision | 6017 | Variable |
| 86 | MachineComponentsType_DefaultInstanceBrowseName | 6018 | Variable |
| 87 | MachineComponentsType_Component_Identification_Manufacturer | 6019 | Variable |
| 88 | MachineComponentsType_Component_Identification_SerialNumber | 6020 | Variable |
| 89 | MachineryItemState_StateMachineType_DefaultInstanceBrowseName | 6021 | Variable |
| 90 | IMachineryItemVendorNameplateType_Manufacturer | 6022 | Variable |
| 91 | IMachineVendorNameplateType_ProductInstanceUri | 6023 | Variable |
| 92 | IMachineryItemVendorNameplateType_SerialNumber | 6024 | Variable |
| 93 | IMachineryItemVendorNameplateType_YearOfConstruction | 6025 | Variable |
| 94 | IMachineryItemVendorNameplateType_MonthOfConstruction | 6026 | Variable |
| 95 | IMachineryItemVendorNameplateType_InitialOperationDate | 6027 | Variable |
| 96 | IMachineTagNameplateType_Location | 6028 | Variable |
| 97 | MachineIdentificationType_Location | 6029 | Variable |
| 98 | MachineIdentificationType_DefaultInstanceBrowseName | 6030 | Variable |
| 99 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__IsNamespaceSubset | 6031 | Variable |
| 100 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__NamespacePublicationDate | 6032 | Variable |
| 101 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__NamespaceUri | 6033 | Variable |
| 102 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__NamespaceVersion | 6034 | Variable |
| 103 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__StaticNodeIdTypes | 6035 | Variable |
| 104 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__StaticNumericNodeIdRange | 6036 | Variable |
| 105 | Server_Namespaces_http___opcfoundation_org_UA_Machinery__StaticStringNodeIdPattern | 6037 | Variable |
| 106 | MachineryItemState_StateMachineType_OutOfService_StateNumber | 6038 | Variable |
| 107 | MachineryItemState_StateMachineType_NotAvailable_StateNumber | 6039 | Variable |
| 108 | MachineryItemState_StateMachineType_Executing_StateNumber | 6040 | Variable |
| 109 | MachineryItemState_StateMachineType_NotExecuting_StateNumber | 6041 | Variable |
| 110 | MachineryItemState_StateMachineType_FromNotAvailableToOutOfService_TransitionNumber | 6042 | Variable |
| 111 | MachineryItemState_StateMachineType_FromNotAvailableToNotExecuting_TransitionNumber | 6043 | Variable |
| 112 | MachineryItemState_StateMachineType_FromNotAvailableToExecuting_TransitionNumber | 6044 | Variable |
| 113 | MachineryItemState_StateMachineType_FromNotAvailableToNotAvailable_TransitionNumber | 6045 | Variable |
| 114 | MachineryItemState_StateMachineType_FromOutOfServiceToNotAvailable_TransitionNumber | 6046 | Variable |
| 115 | MachineryItemState_StateMachineType_FromOutOfServiceToNotExecuting_TransitionNumber | 6047 | Variable |
| 116 | MachineryItemState_StateMachineType_FromOutOfServiceToExecuting_TransitionNumber | 6048 | Variable |
| 117 | MachineryItemState_StateMachineType_FromOutOfServiceToOutOfService_TransitionNumber | 6049 | Variable |
| 118 | MachineryItemState_StateMachineType_FromNotExecutingToNotAvailable_TransitionNumber | 6050 | Variable |
| 119 | MachineryItemState_StateMachineType_FromNotExecutingToOutOfService_TransitionNumber | 6051 | Variable |
| 120 | MachineryItemState_StateMachineType_FromNotExecutingToExecuting_TransitionNumber | 6052 | Variable |
| 121 | MachineryItemState_StateMachineType_FromNotExecutingToNotExecuting_TransitionNumber | 6053 | Variable |
| 122 | MachineryItemState_StateMachineType_FromExecutingToNotAvailable_TransitionNumber | 6054 | Variable |
| 123 | MachineryItemState_StateMachineType_FromExecutingToOutOfService_TransitionNumber | 6055 | Variable |
| 124 | MachineryItemState_StateMachineType_FromExecutingToNotExecuting_TransitionNumber | 6056 | Variable |
| 125 | MachineryItemState_StateMachineType_FromExecutingToExecuting_TransitionNumber | 6057 | Variable |
| 126 | MachineryOperationModeStateMachineType_DefaultInstanceBrowseName | 6058 | Variable |
| 127 | MachineryOperationModeStateMachineType_None_StateNumber | 6059 | Variable |
| 128 | MachineryOperationModeStateMachineType_Maintenance_StateNumber | 6060 | Variable |
| 129 | MachineryOperationModeStateMachineType_Processing_StateNumber | 6061 | Variable |
| 130 | MachineryOperationModeStateMachineType_Setup_StateNumber | 6062 | Variable |
| 131 | MachineryOperationModeStateMachineType_FromNoneToMaintenance_TransitionNumber | 6063 | Variable |
| 132 | MachineryOperationModeStateMachineType_FromNoneToSetup_TransitionNumber | 6064 | Variable |
| 133 | MachineryOperationModeStateMachineType_FromNoneToProcessing_TransitionNumber | 6065 | Variable |
| 134 | MachineryOperationModeStateMachineType_FromNoneToNone_TransitionNumber | 6066 | Variable |
| 135 | MachineryOperationModeStateMachineType_FromMaintenanceToNone_TransitionNumber | 6067 | Variable |
| 136 | MachineryOperationModeStateMachineType_FromMaintenanceToSetup_TransitionNumber | 6068 | Variable |
| 137 | MachineryOperationModeStateMachineType_FromMaintenanceToProcessing_TransitionNumber | 6069 | Variable |
| 138 | MachineryOperationModeStateMachineType_FromMaintenanceToMaintenance_TransitionNumber | 6070 | Variable |
| 139 | MachineryOperationModeStateMachineType_FromSetupToNone_TransitionNumber | 6071 | Variable |
| 140 | MachineryOperationModeStateMachineType_FromSetupToMaintenance_TransitionNumber | 6072 | Variable |
| 141 | MachineryOperationModeStateMachineType_FromSetupToProcessing_TransitionNumber | 6073 | Variable |
| 142 | MachineryOperationModeStateMachineType_FromSetupToSetup_TransitionNumber | 6074 | Variable |
| 143 | MachineryOperationModeStateMachineType_FromProcessingToNone_TransitionNumber | 6075 | Variable |
| 144 | MachineryOperationModeStateMachineType_FromProcessingToMaintenance_TransitionNumber | 6076 | Variable |
| 145 | MachineryOperationModeStateMachineType_FromProcessingToSetup_TransitionNumber | 6077 | Variable |
| 146 | MachineryOperationModeStateMachineType_FromProcessingToProcessing_TransitionNumber | 6078 | Variable |
| 147 | MachineryOperationCounterType_PowerOnDuration | 6079 | Variable |
| 148 | MachineryOperationCounterType_OperationDuration | 6080 | Variable |
| 149 | MachineryOperationCounterType_OperationCycleCounter | 6081 | Variable |
| 150 | MachineryOperationCounterType_DefaultInstanceBrowseName | 6082 | Variable |
| 151 | MachineryLifetimeCounterType_LifetimeVariable | 6083 | Variable |
| 152 | MachineryLifetimeCounterType_LifetimeVariable_LimitValue | 6084 | Variable |
| 153 | MachineryLifetimeCounterType_LifetimeVariable_StartValue | 6085 | Variable |
| 154 | MachineryLifetimeCounterType_LifetimeVariable_EngineeringUnits | 6086 | Variable |
| 155 | MachineryLifetimeCounterType_DefaultInstanceBrowseName | 6087 | Variable |
| 156 | MachineryItemIdentificationType_DefaultInstanceBrowseName | 6088 | Variable |
| 157 | MonitoringType_DefaultInstanceBrowseName | 6089 | Variable |
| 158 | MonitoringType_Status_MachineryItemState_CurrentState | 6090 | Variable |
| 159 | MonitoringType_Status_MachineryItemState_CurrentState_Id | 6091 | Variable |
| 160 | MonitoringType_Status_MachineryOperationMode_CurrentState | 6092 | Variable |
| 161 | MonitoringType_Status_MachineryOperationMode_CurrentState_Id | 6093 | Variable |
| 162 | MonitoringType_Status_Stacklight_StacklightMode | 6094 | Variable |
| 163 | MonitoringType_Health_DeviceHealth | 6095 | Variable |
| 164 | MachineryEquipmentFolderType_MachineryEquipment_AssetId | 6096 | Variable |
| 165 | MachineryEquipmentFolderType_MachineryEquipment_ComponentName | 6097 | Variable |
| 166 | MachineryEquipmentFolderType_MachineryEquipment_Description | 6098 | Variable |
| 167 | MachineryEquipmentFolderType_MachineryEquipment_DeviceClass | 6099 | Variable |
| 168 | MachineryEquipmentFolderType_MachineryEquipment_Location | 6100 | Variable |
| 169 | MachineryEquipmentFolderType_MachineryEquipment_MachineryEquipmentTypeId | 6101 | Variable |
| 170 | MachineryEquipmentFolderType_MachineryEquipment_ManufacturerUri | 6102 | Variable |
| 171 | MachineryEquipmentFolderType_MachineryEquipment_Model | 6103 | Variable |
| 172 | MachineryEquipmentFolderType_MachineryEquipment_SerialNumber | 6104 | Variable |
| 173 | MachineryEquipmentFolderType_DefaultInstanceBrowseName | 6105 | Variable |
| 174 | NotificationsType_DefaultInstanceBrowseName | 6106 | Variable |
| 175 | IMachineryEquipmentType_Description | 6107 | Variable |
| 176 | IMachineryEquipmentType_MachineryEquipmentTypeId | 6108 | Variable |
| 177 | IMachineryEquipmentType_EquipmentLife | 6109 | Variable |
| 178 | IMachineryEquipmentType_EquipmentLife_LimitValue | 6110 | Variable |
| 179 | IMachineryEquipmentType_EquipmentLife_StartValue | 6111 | Variable |
| 180 | IMachineryEquipmentType_EquipmentLife_EngineeringUnits | 6112 | Variable |