# Description Resolves the open items of `plans/ctt-issues.md` (*Needs clarification*, *Open server findings*, *CTT project configuration notes*). Each item was checked against the OPC 10000 spec text. A server change was made only where the server was wrong, and every server change has a regression test. CTT script and oracle defects are filed in Mantis instead. ### Server changes (`Opc.Ua.Server`) - **NumberOfTransitions honours TreatUncertainAsBad.** - Part 13 §5.4.3.24 does not count Bad values. §4.2.1.2 makes Uncertain values "equivalent to Bad" when TreatUncertainAsBad is True, and the aggregate definition doesn't override that. - Uncertain values are therefore no longer counted, and no longer used as the previous value, when the setting is True. The now unused `TimeSlice.NonBadEarlyBound` is removed. - **DurationInStateZero/NonZero status follows the variable's interpolation.** - §5.4.3.2.2: "A region is Uncertain if a region ends in a Bad or Uncertain value and SlopedInterpolation is used." - The calculator always built stepped status regions. So on a sloped variable, the last region stayed Good while TimeAverage2 and Total2 over the same interval were already Uncertain. - The duration value doesn't change. - **AnnotationCount returns `Bad_NoData` and sets Partial.** - Table 68 requires `Bad_NoData` for intervals before the start or after the end of data. §5.3.3.2 requires the Partial bit for incomplete intervals. - `HistorianDispatcher` now derives the start and end of data from the raw history (read with bounds) plus the annotation timestamps. It passes them to a new `CalculateAnnotationCounts` overload; the old overload is unchanged. - Three existing dispatcher tests change their expectations. For example, a node without any data now returns `Bad_NoData` instead of Good zeros. ### Reference server sample and CTT configuration - **`de-DE` ApplicationName.** The server advertises `de-DE` in LocaleIdArray, but FindServers and GetEndpoints always returned the en-US name. The sample now keys the ApplicationName and registers en-US and de-DE translations (Part 4 §5.5.2.2 / §5.5.4.2 localeIds). - **Subscription limit.** `Max Supported Subscriptions` in `samples/UAReferenceServer.ctt.xml` and `MaxSubscriptionCount` in `Ctt.ReferenceServer.Config.xml` go from 100 to 200. Subscription Publish Min 05 `003.js` needs 190 subscriptions. - **Alarm Cycle Time.** The CTT template's Alarm Cycle Time is 30 s. At 60 s it equalled `RequestedSessionTimeout`, so a Limit/Level CU that starts a run finds its session expired (C40). ### Tests only - **AddNodes duplicate BrowseName test:** `AddNodeAsync_DuplicateBrowseNameUnderParent_ReturnsBadBrowseNameDuplicatedAsync` never ran. Its items had no TypeDefinition, so its `Assume` always made it inconclusive. The finding it belongs to (AddNodes after a rename returning `BadNodeIdExists`) was already fixed by #4477. - **RequestHandle echo:** a new test covers the ServiceFault for an oversized argument in a chunked request (already fixed by #4488). - **Value-based status:** a new test covers the aggregate status with TreatUncertainAsBad = false (already fixed by #4503). ### Not changed - **GDS QueryApplications/QueryServers still return records with ServerCapability `NA`.** OPC 10000-12 §6.5.10/§6.5.11 says they "shall not", but the CTT GDS scripts expect those records. Implementing the exclusion turned 40 GDS test cases from pass to error, so it waits for the script fix ([Mantis 11458](https://mantis.opcfoundation.org/view.php?id=11458)). - **Idle SecureChannels are still closed after `ChannelLifetime`.** Keeping them open would be security relevant. The CTT configuration's `ChannelLifetime` of 120000 (#4502) covers the CTT case. ### Mantis issues filed | Id | Issue | | --- | --- | | C51 | [11458](https://mantis.opcfoundation.org/view.php?id=11458) GDS scripts expect NA records in query results | | C52 | [11459](https://mantis.opcfoundation.org/view.php?id=11459) A & C Refresh scripts leak subscriptions on the shared alarm session | | C53 | [11460](https://mantis.opcfoundation.org/view.php?id=11460) `StartThreadPublish.js` defaults misspelled properties | | U2 | [11461](https://mantis.opcfoundation.org/view.php?id=11461) Minimum2 oracle on reverse reads | | U4 | [11462](https://mantis.opcfoundation.org/view.php?id=11462) Part 13 clarification: TreatUncertainAsBad and simple bounds (DeltaBounds) | The A & C `BadSubscriptionIdInvalid` failures (Refresh, Refresh2, Shelving) come from CPU load: with other processes at 100 % CPU, all subscriptions of the CTT alarm session expire within one second. This happens with and without this PR (3 of 3 loaded runs, 0 of 2 idle runs). ### CTT verification CTT 1.05.06, scripts 1.05.513, compared at test-case level against a build of the starting commit: | Group | Before | After | | --- | --- | --- | | Aggregates | 4,562 error messages | 4,186. NumberOfTransitions: 12 test cases go from error to pass. AnnotationCount `005-01.js`/`005-02.js` pass. NumberOfTransitions `003-02.js`/`004-02.js` now fail because of C1 ([Mantis 11420](https://mantis.opcfoundation.org/view.php?id=11420)): they request TreatUncertainAsBad = false, but the harness makes the server use its default of true. | | Discovery | 10 warnings | 0. Find Servers Filter `003.js`/`006.js` and Get Endpoints `002.js` pass. | | Subscription | – | Publish Min 05 `003.js` goes from warning to pass. | | Historical Access, GDS, Node Management | – | no new failures | `plans/ctt-issues.md` is updated: resolved items leave the open sections, and the new Mantis issues are recorded. ## Related Issues - Related to #4479 (CTT configuration notes) - Follows #4502 ## Checklist - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [ ] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. Tests run locally on net10.0 after merging master: | Project | Filter | Passed | | --- | --- | --- | | `Opc.Ua.Server.Tests` | Aggregate, Historian, NodeManagement, Publish, Subscription | 1,419 | | `Opc.Ua.Core.Tests` | TcpServerChannelBuffer | 65 | | `Opc.Ua.History.Tests` | Aggregate, Annotation | 67 | | `Opc.Ua.Sessions.Tests` | discovery locale tests | 8 | Before the merge, the whole `Opc.Ua.Sessions.Tests` ClientTest fixture passed (372 passed, 0 failed). 🤖 Generated with [Claude Code](https://claude.com/claude-code) --------- Co-authored-by: Claude Opus 5 <noreply@anthropic.com>
OPC Foundation UA .NET Standard Reference Server
Introduction
The console reference server can be configured using several console parameters. Some of these parameters are explained in more detail below.
To see all available parameters call console reference server with the parameter -h.
Historical Access
The reference server starts with an in-memory Part 11 historian. Its historized
scalar nodes expose raw, modified, at-time, aggregate, annotation, and update
operations together with populated HistoricalDataConfigurationType
companions. CTT/Historical_KeyValuePairs demonstrates generic
StructuredHistoryData with two KeyValuePair entries at one timestamp. The
CTT notifier exposes historical event read/write bits, a
HistoricalEventConfigurationType companion, and seeded event history.
Writes to the two event-trigger variables report events; live forwarding
completes before the historian snapshots them into its bounded asynchronous
capture queue.
Run the matching client workflow with:
dotnet ConsoleReferenceClient.dll --historian --autoaccept --nosecurity \
opc.tcp://localhost:62541/Quickstarts/ReferenceServer
See docs/HistoricalAccess.md for the
provider contracts, status semantics, and custom storage examples.
Reverse Connect
The OPC UA reverse connect feature allows an OPC UA server to initiate the connection to a client, rather than the traditional model where clients connect to servers. This is particularly useful in scenarios where the server is behind a firewall or NAT, making it difficult for clients to directly connect to it.
How to use Reverse Connect
To enable reverse connect mode, specify the client endpoint URL using the --rc or --reverseconnect parameter:
dotnet ConsoleReferenceServer.dll --rc=opc.tcp://localhost:65300
or
dotnet ConsoleReferenceServer.dll --reverseconnect=opc.tcp://localhost:65300
Example: Server and Client with Reverse Connect
-
Start the client with reverse connect listener on port 65300:
dotnet ConsoleReferenceClient.dll --rc=opc.tcp://localhost:65300 opc.tcp://localhost:62541/Quickstarts/ReferenceServer -
In a separate terminal, start the server with reverse connect to the client:
dotnet ConsoleReferenceServer.dll --rc=opc.tcp://localhost:65300 -a
The server will establish a reverse connection to the client endpoint, and the client will use this connection to communicate with the server.
Additional Options
-aor--autoaccept: Auto accept untrusted certificates (for testing only)-cor--console: Log to console-lor--log: Log app output-tor--timeout: Timeout in seconds to exit application
For the complete list of options, use --help.
X509 user identity certificates
The reference server validates X509 user identity tokens against its trusted-user certificate
store (TrustedUserCertificates, by default %LocalApplicationData%/OPC Foundation/pki/trustedUser).
An untrusted user certificate is rejected with BadIdentityTokenRejected — the --autoaccept option
only auto-accepts the application/channel certificate, never user identity certificates.
To let a trusted client (for example the OPC Foundation Compliance Test Tool) authenticate with an
X509 user token, its user certificate must be present in that store. To make provisioning easy, the
server writes every rejected X509 user certificate to a dedicated review store,
pki/rejectedUser (a sibling of pki/trustedUser). After one failing activation you can move the
legitimate user certificate from pki/rejectedUser/certs into pki/trustedUser/certs (and any
issuing CA into pki/issuerUser/certs) and reconnect. Deliberately-untrusted certificates simply stay
out of the trusted store and continue to be rejected.