# Description Telemetry extensions resolved meters and activity sources as `Opc.Ua.Types`, with results dependent on helper inlining. This prevented reliable attribution to the emitting component. - **Existing telemetry contract**: Add `CreateMeter(Assembly)` and `GetActivitySource(Assembly)` directly to `ITelemetryContext`. The separate `IAssemblyTelemetryContext` interface has been removed. - **Reliable component attribution**: Capture the caller assembly in non-inlined `CreateMeter`, `GetActivitySource`, and `StartActivity` extensions, then forward it to the existing telemetry context. - **Call-site routing and fallback**: Keep non-null meter calls on `telemetry.CreateMeter()`. Use explicit `TelemetryExtensions.CreateMeter(telemetry)` for nullable-context fallback. Preserve default meter/activity-source fallback when a context returns null. - **Coverage and documentation**: Cover caller-assembly naming, direct-context and extension routing, activity creation, and null-result fallback. Update diagnostics examples, OpenTelemetry filters, and migration guidance. **Compatibility:** Direct implementations of `ITelemetryContext` must implement the two new assembly-aware members. `TelemetryContextBase` supplies both. This interface addition is documented in the 2.0 migration guide; legacy implementer compatibility is not claimed. ## Local validation The Release build and focused `TelemetryExtensionsTests` fixture pass on both target frameworks: | Target | Result | | --- | --- | | net10.0 | Passed: 6, Failed: 0, Skipped: 0 | | net48 | Passed: 6, Failed: 0, Skipped: 0 | Both builds emit existing CA5394 warnings in `NodeStateChildNameIndexTests.cs`, which is unchanged by this PR. The full solution test suite was not run during this feedback pass. ## Related Issues ## Checklist - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [x] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [x] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [x] I have addressed **all** PR feedback received. <!-- START COPILOT CODING AGENT SUFFIX --> - Fixes #4483 --------- Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com> Co-authored-by: marcschier <11168470+marcschier@users.noreply.github.com> Co-authored-by: Marc Schier <marcschier@users.noreply.github.com>
OPC Foundation UA .NET Standard Reference Server
Introduction
The console reference server can be configured using several console parameters. Some of these parameters are explained in more detail below.
To see all available parameters call console reference server with the parameter -h.
Historical Access
The reference server starts with an in-memory Part 11 historian. Its historized
scalar nodes expose raw, modified, at-time, aggregate, annotation, and update
operations together with populated HistoricalDataConfigurationType
companions. CTT/Historical_KeyValuePairs demonstrates generic
StructuredHistoryData with two KeyValuePair entries at one timestamp. The
CTT notifier exposes historical event read/write bits, a
HistoricalEventConfigurationType companion, and seeded event history.
Writes to the two event-trigger variables report events; live forwarding
completes before the historian snapshots them into its bounded asynchronous
capture queue.
Run the matching client workflow with:
dotnet ConsoleReferenceClient.dll --historian --autoaccept --nosecurity \
opc.tcp://localhost:62541/Quickstarts/ReferenceServer
See docs/HistoricalAccess.md for the
provider contracts, status semantics, and custom storage examples.
Reverse Connect
The OPC UA reverse connect feature allows an OPC UA server to initiate the connection to a client, rather than the traditional model where clients connect to servers. This is particularly useful in scenarios where the server is behind a firewall or NAT, making it difficult for clients to directly connect to it.
How to use Reverse Connect
To enable reverse connect mode, specify the client endpoint URL using the --rc or --reverseconnect parameter:
dotnet ConsoleReferenceServer.dll --rc=opc.tcp://localhost:65300
or
dotnet ConsoleReferenceServer.dll --reverseconnect=opc.tcp://localhost:65300
Example: Server and Client with Reverse Connect
-
Start the client with reverse connect listener on port 65300:
dotnet ConsoleReferenceClient.dll --rc=opc.tcp://localhost:65300 opc.tcp://localhost:62541/Quickstarts/ReferenceServer -
In a separate terminal, start the server with reverse connect to the client:
dotnet ConsoleReferenceServer.dll --rc=opc.tcp://localhost:65300 -a
The server will establish a reverse connection to the client endpoint, and the client will use this connection to communicate with the server.
Additional Options
-aor--autoaccept: Auto accept untrusted certificates (for testing only)-cor--console: Log to console-lor--log: Log app output-tor--timeout: Timeout in seconds to exit application
For the complete list of options, use --help.
X509 user identity certificates
The reference server validates X509 user identity tokens against its trusted-user certificate
store (TrustedUserCertificates, by default %LocalApplicationData%/OPC Foundation/pki/trustedUser).
An untrusted user certificate is rejected with BadIdentityTokenRejected — the --autoaccept option
only auto-accepts the application/channel certificate, never user identity certificates.
To let a trusted client (for example the OPC Foundation Compliance Test Tool) authenticate with an
X509 user token, its user certificate must be present in that store. To make provisioning easy, the
server writes every rejected X509 user certificate to a dedicated review store,
pki/rejectedUser (a sibling of pki/trustedUser). After one failing activation you can move the
legitimate user certificate from pki/rejectedUser/certs into pki/trustedUser/certs (and any
issuing CA into pki/issuerUser/certs) and reconnect. Deliberately-untrusted certificates simply stay
out of the trusted store and continue to be rejected.