# Description
Complete WoT Binding preservation and the two-pump aggregation workflow
without implicit overlays or multi-source action fan-out.
- Add verified linked-document export and bounded partition merging.
Preserve complete source facts, reject contradictory archival content,
and retain usable readable content when a future native grammar is
unsupported.
- Wire local Methods and Condition events through the existing
injectable binding/runtime infrastructure. Keep local and upstream
identities distinct, translate namespace-bearing values, and bound
occurrence routes by source and generation.
- Wait for asynchronous event-producer readiness before completing
subscription creation, so the first alarm is not lost. Preserve
cancellation, teardown, and startup-failure reporting.
- Import runtime types in inheritance order and attach typed Method
argument Properties. Keep generated Double spelling deterministic across
supported frameworks and remove an AOT-unsafe registry validation
conversion.
- Generate both pumps and their asset/group projections. Expose fifteen
typed readings per pump, separate source-owned controls, and
acknowledge/confirm/reset workflows. Extend the demo script for managed
and NativeAOT execution, bounded failures, and exact-process cleanup.
- Synchronize current-state documentation and specification fixtures.
Compose fixture paths from platform-independent components and emit/pin
LF pump XML so byte-exact regeneration holds on Windows, Linux, and
macOS.
- Keep sample JSON readable with sorted members, two-space indentation,
and LF line endings. Normalize generated filenames to single hyphens
without changing registry resource IDs, document values, logical links,
or dependency ordering; the manifest maps resource IDs to their physical
filenames.
Most changed files are deterministic regenerations of checked-in sample
documents. The demo manifest contains 533 linked resources; the
aggregation server remains generic and has no Pump-specific compiled
model dependency.
No new alarm vocabulary, shelving/suppression/dialog/ConditionRefresh
transport mapping, Azure SDK changes, or complete Pump/OpenUSD parity is
introduced.
## Related Issues
Fixes #4430, which records the approved implementation scope, design
decisions, and acceptance criteria.
Follow-up to #4411. Specification fixtures are pinned to
[OPCF-Members/spec-drafts commit
82620d9](https://github.com/OPCF-Members/spec-drafts/commit/82620d9e313f35386dfc7477f7875cd47d2fd268),
associated with OPCF-Members/spec-drafts#35.
## Validation
- .NET 10 and .NET 8: complete affected converter/schema, WoT
Connectivity, and binding suites passed.
- .NET Framework 4.8: affected libraries, converter/generator, projected
runtime, readiness, and NodeSet-import compatibility runs passed. The
existing filesystem test exceeding the host's legacy path limit passed
through a temporary short-path alias, without changing its assertions.
- All 29 aggregation sample tests passed, including the independent
companion-model oracle.
- Managed/default-port and NativeAOT/alternate-port demo runs completed
with 533 documents, two pumps, thirty Good readings, and all four
pump/source control and alarm workflows.
- Timeout and duplicate-port failure paths were exercised; owned
processes and ports were released.
- Specification artifact/rule checks, byte-identical example mirroring,
statement-digest verification, and changed-file whitespace checks
passed.
- The [Build and Test .NET 10.0 workflow for
278b092](https://github.com/OPCFoundation/UA-.NETStandard/actions/runs/34095520510)
passed, including the previously failing Linux/macOS Types and WoT
Connectivity jobs. Portability fixes preserve the existing assertions
and add an explicit LF-output regression.
- After the readability changes in `dc61d032`, all 131 targeted
sample/projected-runtime cases passed on both .NET 10 and .NET Framework
4.8, and all 29 aggregation sample tests passed after rebuilding. All
539 JSON assets meet the formatting and filename rules; the 538 document
JSON values are unchanged, with only physical paths changing in the
manifest. Byte-exact regeneration assertions remain in place.
Local validation was scoped to affected projects rather than the entire
UA.slnx solution. Numeric coverage percentages and remaining CI gates
remain for CI; coverage thresholds were not changed. Existing unrelated
analyzer warnings were left unchanged.
## Checklist
- [ ] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [ ] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [ ] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [x] I have addressed **all** PR feedback received.
Regression and integration tests are included and passed as described
above; the combined tests/coverage checkbox remains open because numeric
coverage was not measured locally.
---------
Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Copilot-Session: 6a9f41b1-72f0-4c74-bd7f-26fa531e5738
15 KiB
Runtime NodeSets
This guide explains how to load one or more NodeSet2 XML documents into the server's address space at startup without writing a source-generated or hand-coded NodeManager. You configure which files or streams to load; the server imports them in dependency order and registers the resulting nodes.
Within each imported set, types are registered in inheritance order rather than
XML record order. A derived type may precede its supertype in the document;
an inheritance cycle is rejected before registration. Imported namespace-zero
InputArguments and OutputArguments Properties populate their Method's typed
signature, retaining the declared Property NodeIds, argument order, and values.
When to use the runtime NodeSet path
Use AddRuntimeNodeSet when:
- You receive a NodeSet2 XML from a companion-specification vendor and want to host its nodes without regenerating source.
- Your information model changes frequently enough that rebuilding the source-generated manager for every XML update would be disruptive.
- You are prototyping or testing a new NodeSet2 design.
Use the source-generated path when you want compile-time safety, strong typing, and AOT-safe named constants for every node in your model. The runtime path gives you generic NodeState objects and untyped browse-path wiring.
Startup and live lifecycle semantics
AddRuntimeNodeSet on IOpcUaServerBuilder remains the startup path: its factory is created before the server starts and its NodeSet is imported during CreateAddressSpaceAsync.
Running servers also expose INodeManagerLifecycle. Resolve it from dependency injection in a hosted server, or use StandardServer.NodeManagerLifecycle when constructing the server directly. The lifecycle provider can add, reload, shadow-reload, and remove runtime NodeSets without restarting the server.
public sealed class ModelLoader(INodeManagerLifecycle lifecycle)
{
private NodeManagerRegistration? m_registration;
public async ValueTask LoadAsync(CancellationToken ct)
{
m_registration = await lifecycle.AddRuntimeNodeSetAsync(
new RuntimeNodeSetOptions
{
Sources = [RuntimeNodeSetSource.FromFile("Models/MyMachine.NodeSet2.xml")]
},
callerContext: null,
ct);
}
public async ValueTask ReloadAsync(CancellationToken ct)
{
m_registration = await lifecycle.ReloadRuntimeNodeSetAsync(
m_registration!,
new RuntimeNodeSetOptions
{
Sources = [RuntimeNodeSetSource.FromFile("Models/MyMachine.NodeSet2.xml")]
},
callerContext: null,
ct);
}
public ValueTask RemoveAsync(CancellationToken ct)
{
return lifecycle.RemoveAsync(m_registration!, callerContext: null, ct);
}
}
Each add returns an immutable NodeManagerRegistration, and reload returns the next generation while invalidating the previous handle.
AddRuntimeNodeSetAsync, ReloadRuntimeNodeSetAsync, and RemoveAsync take the operation the caller is running under. Pass context.GetOperationContext() when calling from a NodeManager or Method callback: a lifecycle operation drains the requests that are in flight, so one started from inside a request would wait for itself and is rejected with an InvalidOperationException. A control-plane caller such as the ModelLoader above is not serving a request and passes null. See Registering NodeManagers.
The rules that apply to every NodeManager registered at runtime -- what happens to MonitoredItems, Browse continuation points, namespace indexes, DataTypes, and change notifications, and which NodeManagers may be reloaded at all -- are described once in Registering NodeManagers. Runtime NodeSets follow those rules, and the built-in runtime NodeSet manager already implements the INodeManagerReloadParticipant contract that reload requires.
Shadow reload
ShadowReloadRuntimeNodeSetAsync (backed by INodeManagerLifecycle.ShadowReloadAsync) replaces a live registration the same way ReloadRuntimeNodeSetAsync does, but without the active-monitored-item guard:
public async ValueTask ShadowReloadAsync(CancellationToken ct)
{
m_registration = await lifecycle.ShadowReloadRuntimeNodeSetAsync(
m_registration!,
new RuntimeNodeSetOptions
{
Sources = [RuntimeNodeSetSource.FromFile("Models/MyMachine.NodeSet2.xml")]
},
ct);
}
The replacement generation is prepared and published through the same transactional prepare/publish/commit/rollback path as ReloadAsync, so a failure during preparation, publication, or the routing switch leaves the current generation fully active and cleans up the replacement, exactly as a normal reload does. Once committed, every new service request is atomically routed to the replacement generation, including for namespaces the current and replacement generations share.
The current generation is not torn down immediately. It is moved to the same retired-generation bookkeeping used for an ordinary reload, but its existing monitored items and any request or continuation point that already captured it keep being served by it, unaffected by the routing switch. The retired generation is disposed automatically, without deleting any client subscription, once its monitored items and in-flight state drain; a later lifecycle operation (or shutdown) opportunistically retries that cleanup until it succeeds. ShadowReloadAsync returns the replacement NodeManagerRegistration immediately and invalidates the current handle for further lifecycle mutations, the same as ReloadAsync.
Use ShadowReloadAsync when a model update must take effect for new requests without waiting for existing subscriptions to unsubscribe first; use the fail-closed ReloadAsync when a stale generation must never remain reachable, even briefly, for already-open monitored items.
Immediate reload
ImmediateReloadRuntimeNodeSetAsync (backed by INodeManagerLifecycle.ImmediateReloadAsync) performs the same atomic replacement but does not retain the previous generation until monitored items drain. After requests that already captured the old routing generation finish, every affected data-change monitored item is made publishable with BadNodeIdUnknown, event monitored items stop producing events, continuation points are invalidated, and the old NodeManager is disposed. The subscription and monitored-item records remain available so clients can receive the status and delete or recreate the affected items.
Use immediate reload only when continuity through the previous generation is not required. Durable monitored items are not eligible for immediate retirement because their terminal state would have to survive restart; choose shadow reload for any generation that owns them.
Quick-start examples
Single file
services.AddOpcUa()
.AddServer(o => { /* … */ })
.AddRuntimeNodeSet("Models/MyMachine.NodeSet2.xml");
Single file with a fluent callback
Wire read/write/method handlers on top of the imported nodes using the existing untyped INodeManagerBuilder surface:
services.AddOpcUa()
.AddServer(o => { /* … */ })
.AddRuntimeNodeSet(
"Models/MyMachine.NodeSet2.xml",
nodes =>
{
nodes.Node("Machines/Machine1/Start")
.OnCall(StartMachineAsync);
nodes.Variable<double>("Machines/Machine1/Temperature")
.OnRead(ReadTemperature);
});
Group of dependent NodeSets
Register multiple NodeSet2 sources that depend on each other. The factory resolves the import order automatically from the RequiredModel declarations in each document.
services.AddOpcUa()
.AddServer(o => { /* … */ })
.AddRuntimeNodeSet(options =>
{
options.Sources =
[
RuntimeNodeSetSource.FromFile("Models/Opc.Ua.Di.NodeSet2.xml"),
RuntimeNodeSetSource.FromFile("Models/MyMachine.NodeSet2.xml")
];
options.DefaultNamespaceUri = "urn:example:MyMachine";
options.Configure = nodes =>
{
nodes.Node("Machines/Machine1/Start").OnCall(StartMachineAsync);
};
});
Custom stream source
Use RuntimeNodeSetSource.FromStream when you want to open the NodeSet2 document lazily — for example from a database, a blob store, or an assembly resource. The delegate is called for each startup load or live generation and must return a fresh, readable Stream each time.
services.AddOpcUa()
.AddServer(o => { /* … */ })
.AddRuntimeNodeSet(options =>
{
options.Sources =
[
RuntimeNodeSetSource.FromStream(
name: "MyMachine",
openStream: ct => OpenNodeSetStreamAsync(ct),
modelNamespaceUris: ["urn:example:MyMachine"])
];
});
Direct factory registration
If you prefer to create the factory manually — for example to inject it into an existing StandardServer subclass — construct a RuntimeNodeSetNodeManagerFactory directly:
var factory = new RuntimeNodeSetNodeManagerFactory(new RuntimeNodeSetOptions
{
Sources = [RuntimeNodeSetSource.FromFile("Models/MyMachine.NodeSet2.xml")]
});
// In a StandardServer subclass constructor:
AddNodeManager(factory);
Stream ownership contract
When FromStream is used, the runtime loader calls the openStream delegate while each NodeManager generation is created and closes the returned stream after deserialization. You must ensure that:
- Each call to
openStreamreturns a new stream positioned at the beginning. - The stream is readable and contains a valid NodeSet2 XML document.
- You do not close the stream yourself; the factory disposes it after
UANodeSet.Read.
If the delegate returns null or the stream does not contain valid NodeSet2 XML, server startup fails with a clear InvalidOperationException that names the source.
Default namespace for unqualified browse paths
When the Configure callback uses browse paths without an explicit ns=N; prefix (for example "Machines/Machine1/Start"), the runtime loader must know which namespace index to apply for the first path segment. The resolution is:
- If
RuntimeNodeSetOptions.DefaultNamespaceUriis set, that URI is used. - Otherwise the factory infers the unique leaf model — the one model in the loaded group that is not required by any other included source.
- If inference is ambiguous (multiple leaf models and a
Configurecallback is present), startup fails with an error message that lists the candidates. In this case, setDefaultNamespaceUriexplicitly.
When no Configure callback is registered, DefaultNamespaceUri has no effect and may be omitted.
Dependency sorting
The factory reads the Models/Model/RequiredModel entries from each parsed NodeSet document and performs a topological sort (Kahn's algorithm) before importing. Import order guarantees that a required model's nodes are in the address space before any document that depends on them imports its nodes.
Dependencies on models not included in the group — for example the OPC UA base namespace or a third-party model hosted by a generated NodeManager — are silently allowed and treated as external. The server resolves cross-manager references through the normal AddReverseReferencesAsync mechanism.
Referencing a Node another NodeManager owns
A NodeSet may declare a Reference whose other endpoint belongs to a different NodeManager — an inverse Organizes placing an Object under a folder some other model defines, for instance. OPC 10000-3 requires such a Reference to be visible from both ends, so the forward edge has to appear on a Node this NodeManager does not own.
That works in both registration orders. At startup the master collects every NodeManager's external references first and applies them afterwards, so creation order does not matter. A NodeManager added after startup has no such second phase, so the master retains the startup references and each dynamic NodeManager's references, and replays them to any NodeManager registered later. Without that replay a Reference into a NodeManager that did not exist yet would simply be dropped — a reference to an absent Node is discarded rather than queued — leaving the two ends permanently disagreeing: the target browses to the source, the source does not list the target.
Both orders are pinned by RuntimeNodeSetCrossSourceReferenceTests.
Cycles among the included sources cause InvalidOperationException at startup with an error message that lists the participating sources.
Complex types
Runtime complex type loading (structures, enumerations, union types) is on by default and requires no extra configuration. After all NodeManagers have built their address spaces, StandardServer.OnNodeManagerStartedAsync scans every DataType node whose DataTypeDefinition attribute is populated and registers a NativeAOT-safe stand-in encodeable in the server's factory. The same stand-ins are reused for client decode/encode via the OPC UA Part 6 binary protocol.
You can tune this behaviour through the existing ServerComplexTypeOptions:
services.AddOpcUa()
.AddServer(o => { /* … */ })
.AddRuntimeNodeSet("Models/MyMachine.NodeSet2.xml")
.AddComplexTypeSystem(o => o.Enabled = false); // disable if not needed
Setting StandardServer.LoadComplexTypes = false or disabling the complex type system entirely suppresses the stand-in loading without producing a warning. No second complex-type loading path is introduced by the runtime NodeSet feature.
For a complete description of the server-side complex type system, see ComplexTypes.md.
Comparison with source-generated NodeManagers
| Aspect | Runtime NodeSet (AddRuntimeNodeSet) |
Source-generated ([NodeManager]) |
|---|---|---|
| Node access in callbacks | Generic NodeState / BaseVariableState via untyped browse paths |
Strongly typed, compiler-checked fluent accessors per node |
| Compilation required on model change | No — reload through INodeManagerLifecycle |
Yes — regenerate and rebuild |
| AOT / trimming compatibility | Full (uses the existing UANodeSet.Read XmlSerializer path) |
Full (generated code is static) |
| Named NodeId constants | Not generated | Generated (Variables.*, Objects.*, etc.) |
| Multiple namespaces in one manager | Yes — group multiple sources | One namespace per generator run |
| DI registration | AddRuntimeNodeSet(...) |
AddNodeManager<TFactory>() |
| Stream / file input | Files and custom stream factories | MSBuild AdditionalFiles only |
Source-generated managers are the recommended path for production code where type safety and compile-time validation matter. Runtime NodeSets are the recommended path for rapid prototyping, model-file delivery scenarios, and cases where the XML content changes independently of the server binary.
Related documentation
- Source-Generated NodeManagers — strongly typed alternative.
- Dependency Injection —
IOpcUaServerBuilderand service registration. - ComplexTypes.md — server-side complex type loading and client-side decoding.