# Description Remove stock phrasing and correct misleading or inconsistent technical documentation. The initial two passes covered 367 Markdown files, followed by an interactive review of 169 editorial flags. The U5 interpretation originally deferred in that review has since received the upstream Mantis answer recorded by #4843; remaining server/spec follow-ups stay explicit in the CTT log. - Correct package responsibilities, migration steps, API names, ownership, protocol descriptions and links. Keep bundled migration guides synchronized. Preserve historical conclusions as historical records with separate re-check notes. - Provide at least two rendered TOC levels throughout `docs/`. Convert appropriate architecture figures to Mermaid without changing code examples, transcripts or historical quotations. - Address the October 19 feedback with concrete setup/migration instructions, corrected certificate paths and PubSub names, shorter repeated caveats, consistent XML comments, and a full review of the Concepts guide. Retain #4839's API corrections. - Integrate #4841's runtime/performance guidance and review incoming/recent prose. Preserve dated measurements rather than claiming new benchmark runs; clarify allocation ratios, startup-only processor settings, JIT warm-up and the benchmark commit's scope. Missing raw measurement artifacts and repeat ranges remain tracked by #4842. - Merge master through `e8c5d800a` in `32c6394b7`. Resolve the CTT log conflict using the updated Mantis states and OPC answers, retaining historical framing and re-checks for C28/C32/C43. - Address the latest naming/index feedback in `adb5bf693`: rename the guides to `docs/WotCon.md` and `docs/WotNodeSetConversion.md`; move the provider and DataType-declaration contracts into the conversion guide and remove `docs/WoT.md`. Rename `samples/DI` to `samples/Di` and `samples/Isa95` to `samples/ISA95`. Add content-index READMEs to Di, FluentApi, ISA95, Lds and PubSub; update solution entries, project references, Docker/CI paths, test fixture paths and documentation links with exact casing. **WoT guide scope.** This branch retains the detailed conversion guide that #4758 had replaced with an anchor stub. Conversion limits, verified document sets, preservation rules and provider ownership now live together in `WotNodeSetConversion.md`; binding/runtime guidance remains in `WotBindings.md` and `WotCon.md`. The design-rationale/test-ledger prose was shortened, the oversized argument-table cell moved into its section, and existing anchors preserved. **SDK policy is a separate, explicit user-directed change.** `global.json` sets a stable minimum of `10.0.400`, `rollForward: latestMajor`, and `allowPrerelease: false`. Newer major SDKs are permitted; CI's explicit SDK pins are unchanged. README, GettingStarted, DeveloperGuide and Recycling instructions reflect the possible analyzer differences. The image-contract regression fix accepts compatible stable SDK images instead of requiring exact equality with the floor. The latest four rename/index threads are resolved after publication. Three older threads remain open: universal obsolete-removal timing, unconditional nonce-strength wording, and a blanket Vision NativeAOT claim. Existing implementation/evidence constraints are explained in their inline replies. The two-level TOCs remain as requested. ## Validation - `git diff --check` and staged diff checks: passed. The untouched upstream AutoID NodeSet retains its provenance bytes, including two existing license-header trailing spaces. - `.\.azurepipelines\validate-migration-plugin.ps1`: passed; 15 bundled migration documents and manifests synchronized. - Documentation/path validation: **101** documents retain two rendered TOC levels (**2,228** entries), with idempotent formatting. **52** new relative links and their anchors passed exact-case checks. No tracked references to the old guide/sample paths remain. Both relocated provider-contract sections are preserved in the destination. - `dotnet sln UA.slnx list`: passed; shows the renamed Di/ISA95 projects and the existing FluentApi/Lds/PubSub projects. Updated solution and pump ProjectReference paths also passed exact-case existence checks. - Latest focused commands, run from the repository root: ```powershell # Passed: 61 channel send-order and reconnect tests. dotnet test tests\Opc.Ua.Core.Tests\Opc.Ua.Core.Tests.csproj -p:CustomTestTarget=net10.0 --filter 'FullyQualifiedName~UaSCBinaryChannelSendOrderTests|FullyQualifiedName~TcpReconnectKeyAgreementTests' --verbosity minimal # Passed: 5 pump datasheet tests; builds the renamed pump sample. dotnet test tests\Opc.Ua.Di.Tests\Opc.Ua.Di.Tests.csproj -p:CustomTestTarget=net10.0 --filter 'FullyQualifiedName~PumpDatasheetConformanceTests' --verbosity minimal # Passed: 4 repository NodeSet path/round-trip tests, including the moved pump models. dotnet test tests\Opc.Ua.Types.Tests\Opc.Ua.Types.Tests.csproj -p:CustomTestTarget=net10.0 --filter 'FullyQualifiedName~RepositorySourceSurvivesSerializedLinkedPartitionsAsync' --verbosity minimal # Passed: build, zero warnings/errors. dotnet build samples\ISA95\MinimalIsa95Server\MinimalIsa95Server.csproj -p:CustomTestTarget=net10.0 -f net10.0 --verbosity minimal # Passed: dependent sample-test project build, zero warnings/errors. dotnet build tests\Opc.Ua.WotCon.Samples.Tests\Opc.Ua.WotCon.Samples.Tests.csproj -p:CustomTestTarget=net10.0 -f net10.0 --verbosity minimal ``` Earlier focused integration checks passed 2,620 tests across AutoID, event queues/scheduling, source generation, MCP/package profiles and WoT. Both reviewed Mermaid diagrams rendered locally without network access. These checks are not a full solution run. The full solution has **not** been rerun for this review. Earlier `dotnet test UA.slnx -p:CustomTestTarget=net10.0 --verbosity quiet` did not pass: three AOT projects rejected VSTest and 20 Vision tests failed during graphics initialization with `OutOfMemoryException`. Remaining long-running tests were stopped at the user's request. A focused Vision rerun passed 558 tests and reproduced those 20 failures. The earlier `dotnet test UA.slnx -p:CustomTestTarget=net48 --verbosity quiet` was blocked by the former SDK pin and was not retried after the policy change. The user approved proceeding with those limitations documented; current remote CI is not claimed green. ## Related Issues - Follow-up #4842 tracks the requested 2.0.2+ benchmark/tuning and diagnostic-tool documentation refresh. #4841 supplies documentation and earlier results, not all newly requested measurements. - #4758 explains the conversion guide's earlier consolidation; the current provider contracts are now consolidated into `WotNodeSetConversion.md`. - #4839 supplies the reviewed API corrections; #4843 supplies the updated CTT issue record. - The original prose cleanup and SDK policy were user-requested without a source issue. No new runtime architecture is introduced by these documentation edits. ## Checklist _Put an `x` in the boxes that apply. You can complete these step by step after opening the PR._ - [ ] I have signed the [CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf) and read the [CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md) doc. - [ ] I have added tests that prove my fix is effective or that my feature works and increased code coverage. - [x] I have added all necessary documentation. - [ ] I have verified that my changes do not introduce (new) build or analyzer warnings. - [ ] I ran **all** tests locally using the **UA.slnx** solution against at least .net **framework** and .net **10**, and all passed. - [ ] I fixed **all** failing and flaky tests in the CI pipelines and **all** CodeQL warnings. - [ ] I have addressed **all** PR feedback received. --------- Co-authored-by: Roman Ettlinger <romanett98@gmail.com> Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
38 KiB
OPC UA Complex Types
Overview
The Opc.Ua.Client and Opc.Ua.Client.ComplexTypes libraries let client
applications handle custom data types (complex types) in Open Platform
Communications Unified Architecture (OPC UA). Complex types include:
- Custom Structures: User-defined structured data types with multiple fields
- Custom Enumerations: User-defined enumeration types with custom values
The libraries let clients discover and load server-specific types. Clients can then read and write structured values without manually defining each type.
Contents
- Overview
- Key Concepts
- Getting Started
- Approaches for Working with Custom Types
- Advanced Usage
- Common Patterns
- Error Handling
- Performance Considerations
- Troubleshooting
- Server-Side Complex Types
- API Reference
- Known Limitations
- Additional Resources
- See Also
Key Concepts
What are Complex Types?
In OPC UA, complex types are custom data types that a server defines beyond the built-in data types. They commonly represent structured data such as:
- Configuration structures with multiple parameters
- Device status information with multiple fields
- Custom enumerations specific to a domain or device
Type Discovery and Loading
The ComplexTypeSystem class discovers and loads custom types from an OPC UA
server. It:
- Browses the server's type system to discover custom types
- Loads type definitions (using DataTypeDefinition attribute or binary/XML dictionaries)
- Registers types that match those definitions in the session's type factory for encoding and decoding.
Supported Type Systems
The library supports multiple type definition mechanisms:
- OPC UA 1.04+ DataTypeDefinition Attribute: Modern structured type definitions
- OPC UA 1.03 Binary Schema Dictionaries: Legacy binary type dictionaries
- OPC UA 1.03 XML Schema Dictionaries: Legacy XML type dictionaries
The library automatically uses the most appropriate mechanism available on the server.
Getting Started
Type builders
Default type builder
A type builder builds the types that are registered in the EncodeableFactory by the ComplexTypeSystem class. The default type builder registers in memory IEncodeable "adapter" classes that wrap discovered DataTypeDefinition and provide "state" (a list of Variants for the properties) clone, compare, and encode/decode behavior. The default type builder is part of the Opc.Ua.Core.Schema library (namespace Opc.Ua) and is shared by client and server. It is used when no type builder is provided in the constructor of the ComplexTypeSystem class.
Reflection.Emit based type builder
The OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes nuget package extends the Opc.Ua.Client library by adding a type builder implementation that supports dynamically generating .NET types via Reflection.Emit at runtime. This has the added benefit over the default approach that the types can be reflected over by other tools, e.g. serializers. However, this is not NativeAOT compliant, and therefore building against a NativeAOT runtime will always fall back to the default behavior.
To use the Reflection.Emit type builder add the NuGet package to your project:
dotnet add package OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes
Or via Package Manager:
Install-Package OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes
Basic Usage
1. Loading All Custom Types from a Server
The most common approach is to load all custom types after establishing a session:
using Opc.Ua; // ComplexTypeSystem, IComplexTypeResolver, default type builder
using Opc.Ua.Client;
using Opc.Ua.Client.ComplexTypes; // client Create(...) helpers + NodeCacheResolver
// Create and connect session
var session = await Session.Create(...);
// Uses the default NativeAOT-friendly builder.
using var complexTypeSystem = ComplexTypeSystem.Create(
session, session.MessageContext.Telemetry);
await complexTypeSystem.LoadAsync();
Console.WriteLine($"Loaded {complexTypeSystem.GetDefinedTypes().Count} custom types");
The type system owns its resolver; the using declaration releases it even when
loading fails. Types already loaded remain registered with the session. The
optional Reflection.Emit builder is selected through the
custom factory overload, using
new ComplexTypeBuilderFactory() from the separate Client.ComplexTypes package.
After loading, the session can automatically encode and decode custom types when reading or writing values.
2. Reading Values with Complex Types
Once the type system is loaded, reading complex type values is straightforward:
// Read a value that contains a complex type
NodeId nodeId = new NodeId("ns=2;s=MyCustomStructVariable");
DataValue dataValue = await session.ReadValueAsync(nodeId);
// The value is automatically decoded to a .NET type
// Note: DataValue.Value is obsolete. Use WrappedValue (Variant) instead.
if (dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject))
{
// Access the structured data
if (extensionObject.Body is IStructure complexType)
{
// Access properties by name
Variant temperatureValue = complexType["Temperature"];
Variant pressureValue = complexType["Pressure"];
Console.WriteLine($"Temperature: {temperatureValue}");
Console.WriteLine($"Pressure: {pressureValue}");
// Enumerate all properties
foreach (IStructureField property in complexType.GetFields())
{
Console.WriteLine($"{property.Name}: {complexType[property.Name]}");
}
}
}
3. Writing Values with Complex Types
To write complex type values, modify the properties and write back:
// Read current value
DataValue dataValue = await session.ReadValueAsync(nodeId);
dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject);
var complexType = (IStructure)extensionObject.Body;
// Modify properties
complexType["Temperature"] = 25.5;
complexType["Pressure"] = 101.3;
// Write the modified value back
var writeValue = new WriteValue
{
NodeId = nodeId,
AttributeId = Attributes.Value,
Value = new DataValue
{
WrappedValue = extensionObject,
SourceTimestamp = DateTime.UtcNow
}
};
ArrayOf<WriteValue> writeValues = [writeValue];
var response = await session.WriteAsync(null, writeValues, CancellationToken.None);
if (StatusCode.IsGood(response.Results[0]))
{
Console.WriteLine("Value written successfully");
}
Approaches for Working with Custom Types
There are three ways to work with custom data types from an OPC UA server. The right approach depends on your use case.
Approach 1: Hand-Written IEncodeable + EncodeableFactory Registration
If you have already implemented (or generated) a class that implements IEncodeable, you can register it with the session's EncodeableFactory. The stack will then automatically decode incoming ExtensionObject values into instances of your type.
Step 1 – Implement IEncodeable
// Required namespaces:
// using Opc.Ua;
// using System.Runtime.Serialization;
[DataContract(Namespace = "http://www.siemens.com/simatic-s7-opcua")]
public class UDT_SemVer : IEncodeable
{
public UDT_SemVer() { Initialize(); }
[OnDeserializing]
private void Initialize(StreamingContext context = default) { }
[DataMember(Name = "Major", IsRequired = true, Order = 1)]
public byte Major { get; set; }
[DataMember(Name = "Minor", IsRequired = true, Order = 2)]
public byte Minor { get; set; }
[DataMember(Name = "Patch", IsRequired = true, Order = 3)]
public byte Patch { get; set; }
// TypeId must match the DataType NodeId on the server.
// The "DT_" prefix is a Siemens S7 OPC UA convention for data type nodes;
// the quoted name is the Siemens-specific identifier format.
public ExpandedNodeId TypeId =>
new ExpandedNodeId(
"nsu=http://www.siemens.com/simatic-s7-opcua;s=DT_\"UDT_SemVer\"");
// BinaryEncodingId must match the Binary Encoding NodeId on the server.
// The "TE_" prefix is the Siemens S7 OPC UA convention for type encoding nodes.
public ExpandedNodeId BinaryEncodingId =>
new ExpandedNodeId(
"nsu=http://www.siemens.com/simatic-s7-opcua;s=TE_\"UDT_SemVer\"");
public ExpandedNodeId XmlEncodingId => ExpandedNodeId.Null;
public void Encode(IEncoder encoder)
{
encoder.WriteByte("Major", Major);
encoder.WriteByte("Minor", Minor);
encoder.WriteByte("Patch", Patch);
}
public void Decode(IDecoder decoder)
{
Major = decoder.ReadByte("Major");
Minor = decoder.ReadByte("Minor");
Patch = decoder.ReadByte("Patch");
}
public bool IsEqual(IEncodeable? encodeable) =>
encodeable is UDT_SemVer other &&
Major == other.Major && Minor == other.Minor && Patch == other.Patch;
public object Clone() => MemberwiseClone();
}
Important
:
BinaryEncodingIdmust match the Binary Encoding NodeId returned by the server (visible in the OPC UA address space as theDataTypeEncodingTypechild node named"Default Binary"). The decoder uses this NodeId to look up the registered type.
Step 2 – Register the Type Before Reading
Register the type with the session's factory before reading any values that use it. The simplest way is to add the Type directly:
// Create and connect the session
var session = await Session.Create(...);
// Register the custom type with the session's encodeable factory
session.Factory.Builder
.AddEncodeableType(typeof(UDT_SemVer))
.Commit();
// Now read – the stack decodes the ExtensionObject automatically
DataValue result = await session.ReadValueAsync(
"ns=3;s=\"H35dispenser\".\"ID\".\"ElectricalVersion\"");
if (result.WrappedValue.TryGetValue(out ExtensionObject extObject) &&
extObject.Body is UDT_SemVer semVer)
{
Console.WriteLine($"Major={semVer.Major} Minor={semVer.Minor} Patch={semVer.Patch}");
}
You can also register all types from an entire assembly at once:
session.Factory.Builder
.AddEncodeableTypes(typeof(UDT_SemVer).Assembly)
.Commit();
Or register multiple types individually in a single builder chain:
session.Factory.Builder
.AddEncodeableType(typeof(UDT_SemVer))
.AddEncodeableType(typeof(UDT_AnotherType))
.Commit();
Note
:
ComplexTypeSystem.LoadAsync()is not required when using this approach. If you callLoadAsync()after registering your own types, the ComplexTypeSystem will skip types that are already registered in the factory.
Approach 2: Source-Generated IEncodeable (Recommended for New Code)
Starting with version 2.0, you can annotate a POCO class with [DataType] and
optional [DataTypeField] attributes and the OPC UA source generator will
automatically generate the IEncodeable implementation for you. This eliminates
the need to hand-write Encode, Decode, IsEqual, and Clone methods.
See Source-Generated Data Types for full details.
using Opc.Ua;
[DataType(Namespace = "http://www.siemens.com/simatic-s7-opcua",
BinaryEncodingId = "s=TE_\"UDT_SemVer\"")]
public partial class UDT_SemVer
{
[DataTypeField(Order = 1)]
public byte Major { get; set; }
[DataTypeField(Order = 2)]
public byte Minor { get; set; }
[DataTypeField(Order = 3)]
public byte Patch { get; set; }
}
After adding the source generator NuGet package, the generated registration extension method can be used:
session.Factory.Builder
.AddMyNamespaceDataTypes()
.Commit();
Approach 3: Runtime IStructure (No Pre-defined Types Required)
If you do not know the type structure at compile time, or prefer not to create
.NET types for every server type, use ComplexTypeSystem to load the type
definitions at runtime and access fields via the IStructure interface. This
requires no hand-written types.
See the Basic Usage and Advanced Usage sections below for examples.
Advanced Usage
Loading Specific Types
Instead of loading all types, you can load specific types or namespaces:
Load a Specific Type
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
// Load a specific type by NodeId
ExpandedNodeId typeNodeId = new ExpandedNodeId("ns=2;i=3001");
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId);
if (systemType != null)
{
Console.WriteLine($"Loaded type: {systemType.XmlName}");
}
Load a Specific Type with Subtypes
// Load a type and all its subtypes
ExpandedNodeId typeNodeId = new ExpandedNodeId("ns=2;i=3001");
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId, subTypes: true);
Load All Types from a Namespace
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
// Load all custom types from a specific namespace
string namespaceUri = "http://mycompany.com/MyCustomTypes";
bool success = await complexTypeSystem.LoadNamespaceAsync(namespaceUri);
if (success)
{
Console.WriteLine($"Successfully loaded types from namespace: {namespaceUri}");
}
Working with Complex Type Properties
The IStructure interface provides flexible access to complex type fields:
Access by Name
if (extensionObject.Body is IStructure complexType)
{
// Get property value by name
Variant value = complexType["PropertyName"];
// Set property value by name
complexType["PropertyName"] = newValue;
}
Access by Index
if (extensionObject.Body is IStructure complexType)
{
// Get property value by index
Variant value = complexType[0];
// Set property value by index
complexType[0] = newValue;
}
Enumerate Properties
if (extensionObject.Body is IStructure complexType)
{
// Enumerate with detailed information
foreach (IStructureField property in complexType.GetFields())
{
Console.WriteLine($"Property: {property.Name}");
Console.WriteLine($" Type: {property.TypeInfo}");
Console.WriteLine($" IsOptional: {property.IsOptional}");
Console.WriteLine($" Value: {complexType[property.Name]}");
}
}
Handling Enumeration Types
Custom enumerations are also supported:
// After loading the type system, enum values are automatically decoded
DataValue dataValue = await session.ReadValueAsync(enumNodeId);
if (dataValue.WrappedValue.TryGetValue(out EnumValue enumValue))
{
// The value is the numeric representation
Console.WriteLine($"Enum value: {enumValue}");
// You can also get the enum type from the factory
ExpandedNodeId enumTypeId = ...;
if (session.Factory.TryGetEnumeratedType(enumTypeId, out IEnumeratedType enumType))
{
Console.WriteLine($"Enum type: {enumType.XmlName}");
}
}
Type Information and Introspection
Get All Loaded Types
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
await complexTypeSystem.LoadAsync();
// Get all types that were dynamically created
IReadOnlyList<XmlQualifiedName> definedTypes = complexTypeSystem.GetDefinedTypes();
foreach (XmlQualifiedName type in definedTypes)
{
Console.WriteLine($"Type: {type.Namespace}.{type.Name}");
}
Get Type Definitions
// Get the DataTypeDefinition for a specific type
ExpandedNodeId dataTypeId = new ExpandedNodeId("ns=2;i=3001");
var definitions = complexTypeSystem.GetDataTypeDefinitionsForDataType(dataTypeId);
foreach (var kvp in definitions)
{
Console.WriteLine($"NodeId: {kvp.Key}");
Console.WriteLine($"Definition: {kvp.Value}");
}
Get Loaded Data Type IDs
// Get all NodeIds for loaded data types
IEnumerable<ExpandedNodeId> dataTypeIds = complexTypeSystem.GetDefinedDataTypeIds();
foreach (var dataTypeId in dataTypeIds)
{
Console.WriteLine($"Loaded type: {dataTypeId}");
}
Using Custom Type Factories
You can provide a custom type factory for advanced scenarios:
// Create a custom factory (implement IComplexTypeFactory)
IComplexTypeFactory customFactory = new MyCustomComplexTypeFactory();
// Use it with the ComplexTypeSystem
using var complexTypeSystem = ComplexTypeSystem.Create(
session, customFactory, session.MessageContext.Telemetry);
await complexTypeSystem.LoadAsync();
Working with Telemetry and Logging
Pass the session's telemetry context, or an application-provided ITelemetryContext,
to the factory. The type system logs loading diagnostics through that context.
ITelemetryContext telemetry = session.MessageContext.Telemetry;
using var complexTypeSystem = ComplexTypeSystem.Create(session, telemetry);
await complexTypeSystem.LoadAsync();
Keep the type system alive while loading types, and dispose it afterward even if loading fails. Loaded types remain registered with the session's factory.
Common Patterns
Pattern 1: One-Time Type Loading at Session Start
After establishing a session with the managed client API, load its types before reading custom values:
await using ManagedSession session = await new ManagedSessionBuilder(configuration, telemetry)
.UseEndpoint(endpoint)
.ConnectAsync(ct);
using var complexTypeSystem = ComplexTypeSystem.Create(session, telemetry);
await complexTypeSystem.LoadAsync(ct: ct);
Keep the session alive for subsequent reads. Disposing the loader releases its resolver, not the types registered in the session.
Pattern 2: Lazy Loading on Demand
Load a known DataType only when needed, then read its value. This avoids keeping a loader field alive merely to retain registered types:
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
IType? loadedType = await complexTypeSystem.LoadTypeAsync(typeNodeId);
if (loadedType == null)
{
throw new InvalidOperationException("The server DataType could not be loaded.");
}
DataValue value = await session.ReadValueAsync(variableNodeId);
Coordinate concurrent loading at the application's session boundary rather than using an unsynchronized Boolean flag. See type system caching for reuse guidance.
Pattern 3: Reading Multiple Complex Values
public async Task ReadMultipleComplexValuesAsync(IList<NodeId> nodeIds)
{
// Load types once
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
await complexTypeSystem.LoadAsync();
// Read all values
var nodesToRead = nodeIds.Select(id => new ReadValueId
{
NodeId = id,
AttributeId = Attributes.Value
}).ToList();
var response = await session.ReadAsync(
null,
0,
TimestampsToReturn.Both,
new ReadValueIdCollection(nodesToRead),
CancellationToken.None
);
// Process results
for (int i = 0; i < response.Results.Count; i++)
{
var dataValue = response.Results[i];
if (dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject) &&
extensionObject.Body is IStructure complexType)
{
Console.WriteLine($"NodeId: {nodeIds[i]}");
foreach (IStructureField property in complexType.GetFields())
{
Console.WriteLine($" {property.Name}: {complexType[property.Name]}");
}
}
}
}
Error Handling
Handling Type Loading Failures
try
{
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
bool success = await complexTypeSystem.LoadAsync(throwOnError: true);
if (success)
{
Console.WriteLine("All types loaded successfully");
}
else
{
Console.WriteLine("Some types could not be loaded");
}
}
catch (ServiceResultException ex)
{
Console.WriteLine($"Failed to load types: {ex.Message}");
// Handle error appropriately
}
Handling Missing Type Definitions
// Try to load a specific type
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId, throwOnError: false);
if (systemType == null)
{
Console.WriteLine($"Type {typeNodeId} could not be loaded");
// Fall back to reading as ExtensionObject with opaque body
}
Performance Considerations
Type System Caching
- The
ComplexTypeSystemloads types once and caches them in the session's factory - Subsequent reads/writes use the cached types automatically
- Types remain available for the lifetime of the session
Minimizing Load Time
// Load only enumerations (faster)
using var complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
await complexTypeSystem.LoadAsync(onlyEnumTypes: true);
// Or load only specific namespaces
await complexTypeSystem.LoadNamespaceAsync("http://mycompany.com/MyTypes");
Batch Operations
When reading multiple values with complex types, read them in batches to minimize round-trips:
// Read multiple values in one call
var response = await session.ReadAsync(
null,
0,
TimestampsToReturn.Both,
new ReadValueIdCollection(nodesToRead),
CancellationToken.None
);
Troubleshooting
Types Not Loading
Problem: LoadAsync() completes but types are not available
Solutions:
- Verify the server supports DataTypeDefinition or provides type dictionaries
- Check server logs for encoding/dictionary availability
- Use verbose logging to see what types are discovered
// Enable detailed logging through telemetry context
var telemetry = session.MessageContext.Telemetry;
using var complexTypeSystem = ComplexTypeSystem.Create(session, telemetry);
// The ComplexTypeSystem will log detailed information during type loading
await complexTypeSystem.LoadAsync();
Values Still Encoded as ExtensionObject
Problem: Values are read as ExtensionObject with opaque body instead of structured types
Solutions:
- If using
ComplexTypeSystem: ensureLoadAsync()was called before reading the value, verify the type is actually loaded withcomplexTypeSystem.GetDefinedTypes(), and check if the server's type definition is complete and valid. - If using a hand-written
IEncodeable(Approach 1): ensure the type is registered withsession.Factory.Builder.AddEncodeableType(typeof(YourType)).Commit()before reading. TheBinaryEncodingIdon your type must exactly match the Binary Encoding NodeId reported by the server — use a generic OPC UA client (e.g. UA Expert) to inspect the correct NodeId. - If using source-generated types (Approach 2): ensure the generated
Add...DataTypes()extension method is called onsession.Factory.Builderbefore reading.
Performance Issues
Problem: Type loading takes too long
Solutions:
- Load only required namespaces instead of all types
- Load types once at session start rather than on-demand
- Consider caching type information across sessions if reconnecting frequently
Server-Side Complex Types
Servers can build the same dynamic stand-in encodeables for custom DataTypes in their address space. This is useful when a server loads a NodeSet2 at runtime and its DataTypes have no compiled .NET types. Without a matching encodeable, the server cannot encode or decode instances of those DataTypes.
Server-side complex types prime the server's IEncodeableFactory with
stand-ins built from each custom DataType's DataTypeDefinition attribute.
This reuses the client's NativeAOT-friendly ComplexTypeSystem path in
Opc.Ua.Core.Schema. StandardServer runs this by default; control it with
LoadComplexTypes.
The server uses compiled, source-generated DataTypes as-is because the
generator already registers them in IEncodeableFactory. It builds stand-ins
only for DataTypes missing from the factory, such as types loaded from a
NodeSet at runtime.
If you are using Runtime NodeSets, the server-side complex-type pass runs automatically after startup imports and before each live lifecycle generation is published. No extra configuration is needed. See RuntimeNodeSets.md for startup and live add/reload/remove semantics, compatible DataType rules, and the stream ownership contract.
How compiled types reach the factory
Compiled DataTypes register explicitly, not through reflection. The OPC UA
source generator emits an Add<Namespace>(this IEncodeableFactoryBuilder)
extension for each namespace. A node manager calls the extension while it
builds its address space, for example
Server.Factory.Builder.AddTestData().Commit().
Node managers finish starting before OnNodeManagerStartedAsync runs.
Therefore, all source-generated types are already in server.Factory when
the complex-type pass executes. ComplexTypeSystem finds these types with
TryGetType or TryGetEncodeableType and skips them. It creates stand-ins
only for runtime-loaded DataTypes that remain.
Configuring via dependency injection (recommended)
Complex-type loading is on by default. Use the fluent AddComplexTypeSystem() extension when configuring the hosted server to tune the pass and expose the primed factory as a DI-resolvable schema IDataTypeDefinitionResolver:
using Microsoft.Extensions.DependencyInjection;
builder.Services
.AddOpcUa()
.AddServer(options => { /* ... */ })
.AddNodeManager<MyRuntimeNodeSetNodeManagerFactory>()
.AddComplexTypeSystem(); // build stand-ins for runtime-loaded DataTypes
The pass runs once after the server builds its address space and before it accepts connections. Clients therefore do not encounter custom values that they cannot decode.
The server also exposes the primed IEncodeableFactory as a schema
IDataTypeDefinitionResolver through EncodeableFactoryDefinitionSource.
This lets the server produce schemas directly from the factory without
populating a separate registry or walking the address space. If a
DataTypeDefinitionRegistry is registered, for example through
AddSchemaGeneration() for schema-only types without an encodeable, the
server composes it as a fallback.
Options can be configured:
.AddComplexTypeSystem(options =>
{
options.Enabled = true; // load complex types on startup (default)
options.OnlyEnumTypes = false; // also build structured types (default)
options.ThrowOnError = false; // log and continue on failures (default)
});
Direct usage without dependency injection
For servers that are not hosted through dependency injection, no extra type is required: StandardServer loads complex types by default (LoadComplexTypes), so a plain instance already builds the stand-ins once its address space is available:
var server = new StandardServer(telemetry);
await application.StartAsync(server);
Opt out by setting server.LoadComplexTypes = false before starting. To customize the pass — for example to load only enumerations — override OnNodeManagerStartedAsync in a StandardServer subclass and drive it yourself instead of calling base (which would run the default pass):
protected override async ValueTask OnNodeManagerStartedAsync(
IServerInternal server, CancellationToken cancellationToken)
{
var options = new ServerComplexTypeOptions { OnlyEnumTypes = true };
await server
.LoadComplexTypesAsync(server.Telemetry, options, cancellationToken: cancellationToken)
.ConfigureAwait(false);
}
IServerInternal.LoadComplexTypesAsync(...) can also be invoked directly on a running server to (re)build the stand-ins on demand. It drives the shared ComplexTypeSystem with an AddressSpaceComplexTypeResolver that surfaces the server's DataType nodes and their DataTypeDefinition attributes, and returns an IDataTypeDefinitionResolver backed by the primed factory. Because the runtime stand-ins (and the generated types) expose their definition via IDataTypeDefinitionSource, the encodeable factory itself is the source of truth for data type definitions — the DataTypeDefinitionRegistry is only needed for schema-only types that have no encodeable.
API Reference
ComplexTypeSystem Class
The main class for managing complex types.
Constructors
// The ComplexTypeSystem type is defined in Opc.Ua.Core.Schema (namespace Opc.Ua).
// Create with a complex type resolver and telemetry (uses the default DefaultComplexTypeFactory)
ComplexTypeSystem(IComplexTypeResolver complexTypeResolver, ITelemetryContext telemetry)
// Create with a resolver, a custom type builder factory and telemetry
ComplexTypeSystem(IComplexTypeResolver complexTypeResolver, IComplexTypeFactory complexTypeBuilderFactory, ITelemetryContext telemetry)
// As above; ownsResolver: true makes Dispose() also dispose the resolver. The other
// constructors leave a caller-supplied resolver with the caller.
ComplexTypeSystem(IComplexTypeResolver complexTypeResolver, IComplexTypeFactory complexTypeBuilderFactory, ITelemetryContext telemetry, bool ownsResolver)
// Client factory helpers (Opc.Ua.Client, namespace Opc.Ua.Client.ComplexTypes) bind a
// ComplexTypeSystem to a session through a NodeCacheResolver with its own node cache.
// The returned system owns that resolver, so dispose it when done loading types:
// Uses the default, NativeAOT friendly type builder
static ComplexTypeSystem ComplexTypeSystem.Create(ISession session, ITelemetryContext telemetry)
// Uses a caller-provided type builder, e.g. the Reflection.Emit ComplexTypeBuilderFactory
// (requires the OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes package)
static ComplexTypeSystem ComplexTypeSystem.Create(ISession session, IComplexTypeFactory complexTypeBuilderFactory, ITelemetryContext telemetry)
Methods
// Load all custom types from the server
ValueTask<bool> LoadAsync(bool onlyEnumTypes = false, bool throwOnError = false, CancellationToken ct = default)
// Load a specific type with optional subtypes
Task<IType?> LoadTypeAsync(ExpandedNodeId nodeId, bool subTypes = false, bool throwOnError = false, CancellationToken ct = default)
// Load all types from a namespace
Task<bool> LoadNamespaceAsync(string ns, bool throwOnError = false, CancellationToken ct = default)
// Get all dynamically created type names
IReadOnlyList<XmlQualifiedName> GetDefinedTypes()
// Get all loaded data type NodeIds
IEnumerable<ExpandedNodeId> GetDefinedDataTypeIds()
// Get data type definitions for a type
NodeIdDictionary<DataTypeDefinition> GetDataTypeDefinitionsForDataType(ExpandedNodeId dataTypeId)
// Clear the data type cache
void ClearDataTypeCache()
Properties
// Get the loaded data type dictionaries
NodeIdDictionary<DataDictionary> DataTypeSystem { get; }
IStructure Interface
Interface for accessing properties of complex types.
// Access property by zero-based index
Variant this[int index] { get; set; }
// Access property by name
Variant this[string name] { get; set; }
// Get property names
IReadOnlyList<IStructureField> GetFields()
IStructureField Interface
Provides metadata about a property in a complex type.
string Name { get; } // Property name
bool IsOptional { get; } // Whether field is optional
TypeInfo TypeInfo { get; } // Type info of the field
Known Limitations
- OptionSet Support: Concrete Structure-backed sub-types of the abstract
OptionSetDataType (i=12755, e.g.AccessRights,CarExtras) are automatically registered by the defaultComplexTypeSystembuilder asOpc.Ua.Encoders.OptionSetruntime instances, driven by either theEnumDefinitioncarried inDataTypeDefinitionor a fallback synthesized from theOptionSetValuesproperty. The runtime class exposes the two canonicalValue/ValidBitsByteStrings plus bit accessors keyed by field name or bit index. Per Part 3 §8.40 / §3.2.8, the overall ByteString length is fixed by the sub-type's declared bits (exposed asByteLength); setting a bit outside that range throwsArgumentOutOfRangeException. Remaining limitations:- UInteger-backed OptionSet DataTypes (DataTypes deriving from an unsigned integer with
IsOptionSet=true) continue to be represented as their underlying unsigned integer in aVariant— no per-bit metadata is surfaced. - The legacy Reflection.Emit builder in
Opc.Ua.Client.ComplexTypesthrowsNotSupportedExceptionfor OptionSet sub-types; switch to the default builder (ComplexTypeSystem.Create(session, telemetry)) for OptionSet support.
- UInteger-backed OptionSet DataTypes (DataTypes deriving from an unsigned integer with
- Legacy Dictionary Support: Some OPC UA 1.03 structured types that cannot be mapped to OPC UA 1.04 definitions are ignored
- Type Modifications: Once loaded, types cannot be dynamically updated during a session. Reconnect to reload modified types.
Additional Resources
- OPC UA Specification Part 3 - Address Space Model
- OPC UA Specification Part 5 - Information Model
- OPC UA Specification Part 6 - Mappings
- OPC Foundation .NET Standard Samples
- NuGet Package: OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes
See Also
- Source-Generated Data Types - Auto-generate IEncodeable implementations from annotated POCO classes
- Developer Guide - Building, testing, platform support, packages, and versioning
- Diagnostics Documentation - Logging, telemetry, audit events, server diagnostics, and packet capture
- Console Reference Client - Example client implementation