Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com> Co-authored-by: Klaus Landsdorf <kl@iniationware.com> Co-authored-by: Marc Schier <marcschier@users.noreply.github.com> Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com> Co-authored-by: marcschier <11168470+marcschier@users.noreply.github.com> Co-authored-by: romanett <7413710+romanett@users.noreply.github.com>
5.2 KiB
OPC 10000-110 Asset Management Basics samples
Two console applications that show the Opc.Ua.AMB* libraries end to end: a
server that makes Device Integration devices and a Machinery machine
manageable assets, and a client that finds and reads them with AmbClient.
| Sample | What it does |
|---|---|
| AmbServer | Serves a cooling pump, the flow sensor it relies on and a hydraulic press as assets, and simulates their health alarms and maintenance |
| AmbClient | Discovers every asset, prints a snapshot of each, the location hierarchies, adds and removes a documentation link, and streams health alarms and maintenance activities |
The Asset Management Basics developer guide explains every API used here.
Run
In two terminals:
dotnet run --project samples/AMB/AmbServer -- --port 62553
dotnet run --project samples/AMB/AmbClient -- --insecure --seconds 60
--insecure makes the client accept the server's self-signed certificate;
never use it in production. The client also takes --url <endpoint> (default
opc.tcp://localhost:62553/AmbServer), --seconds <n> (how long to stream,
0 to skip) and --asset-id <id> (writes a new AssetId to the first asset
that has one and finds the asset by it).
The server keeps what clients write - AssetIds, edited and added
documentation links, the writable location and local time - below the local
application data folder (OPC Foundation/AmbServer/state), or in the folder
given with --state <directory>. Stop the server, start it again, and the
client reads the values it wrote before.
What the server shows
| File | Shows |
|---|---|
Program.cs |
AddMachinery() as the owner of the Device Integration address space, AddAssetManagement(...) with UseFileSystemStores, ConfigureAssetManagement(...) defining the location hierarchies and the ECLASS dictionary entry, ConfigureMachinery<T>() and ConfigureDevicesFor<MachineryNodeManager>(...) |
Plant.cs |
Two DI devices registered with RegisterAsAssetAsync: every building block - configurable AssetId, DeviceHealth derived from the alarms, health alarms, maintenance activities with details, documentation links (fixed, editable, user links), version information, locations and local time, classification, requirements and capabilities, and a 0:Utilizes relation between the assets |
PressConfigurator.cs |
A Machinery machine registered through IMachineHandle<T>.AsNode(); its servicing switches the machine into the Maintenance operation mode while it executes |
PlantSimulation.cs |
A BackgroundService that raises and clears a bearing temperature alarm with the sensor as root cause once a minute, fails the self test of the sensor every five minutes (AssetRootCauses.Self), and moves a maintenance activity of the pump and of the press on every two minutes |
Health alarms and maintenance activities are created while the owning node
manager builds its address space, which is why Plant and
PressConfigurator register the assets from the DI and Machinery setup.
What the client shows
Code in Program.cs |
Shows |
|---|---|
connection.Session.AssetManagement(telemetry) |
Creating the client; registers the AMB structured types |
amb.IsSupported |
Detecting whether the server publishes the AMB namespace |
DiscoverAssetsAsync |
All assets from the AMB alias categories |
ReadAssetAsync → AssetSnapshot |
Identification, DeviceHealth, alarms, maintenance, links, locations and classification in one pass |
BrowseLocationsAsync |
The hierarchical and operational location trees and the assets in them |
AddDocumentationLinkAsync, ReadDocumentationLinksAsync, RemoveDocumentationLinkAsync |
The DocumentationLinks AddIn |
WriteAssetIdAsync, FindAssetsAsync |
Configuring an AssetId and finding the asset by it |
ObserveHealthAlarmsAsync, AcknowledgeAsync |
Health alarms with severity, fault category and root causes; a cleared alarm is acknowledged |
ObserveMaintenanceAsync |
Maintenance activities moving through Planned, Executing and Finished |
SampleSession.cs is the session setup. It
keeps the ApplicationInstance alive until the session closes, because the
instance owns the CertificateManager the session validates with, and it
creates a ManagedSession, whose default streaming subscription the observe
calls use.
Troubleshooting
| Symptom | Fix |
|---|---|
Client reports BadCertificateUntrusted |
Pass --insecure for the demo, or trust the server certificate in the client's PKI (under the local application data folder, OPC Foundation/AmbClient/pki) |
AddLink / RemoveLink: refused: BadUserAccessDenied |
The server refuses anonymous link editing unless AuthorizeLinkEdit allows it; the sample server allows it |
| The stream shows nothing for a while | The alarm becomes active 20 s into every minute and maintenance moves on every two minutes; stream longer with --seconds |
| Port already in use | Start the server with --port <n> and the client with --url opc.tcp://localhost:<n>/AmbServer |