Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com> Co-authored-by: Klaus Landsdorf <kl@iniationware.com> Co-authored-by: Marc Schier <marcschier@users.noreply.github.com> Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com> Co-authored-by: marcschier <11168470+marcschier@users.noreply.github.com> Co-authored-by: romanett <7413710+romanett@users.noreply.github.com>
OPC 40001 Machinery samples
Two console applications that show the whole OPC 40001 series end to end.
| Sample | What it does |
|---|---|
| MachineryServer | Serves one simulated hydraulic press with every part of the series |
| MachineryClient | Walks the Machines folder, prints what it finds, downloads a result and streams state |
Run them in two terminals:
dotnet run --project samples/Machinery/MachineryServer -- --port 62546
dotnet run --project samples/Machinery/MachineryClient -- --insecure
The client prints something like:
Machine 12:HydraPress-1 (ns=12;i=1)
Acme Machine Tools HydraPress 500 — serial HP500-2024-0001
location: Hall 3 / Line 2
state: Executing / mode: Processing
component 12:HydraulicUnit
building block 13:Identification
building block 3:MachineryEquipment
building block 8:JobManagement
building block 3:Monitoring
building block 3:MachineryItemState
building block 3:Notifications
building block 13:OperationCounters
building block 3:MachineryOperationMode
building block 3:Components
device health: NORMAL
operation counters: power-on 12480.0 h, operating 9215.5 h
equipment UpperDie (urn:acme-machine-tools.example:equipment:die)
life: 118400 of 250000 left
process value HydraulicOilTemperature: 44.0 °C (setpoint 45.0, 45.7 % of range)
limits: 5.0 / 15.0 / 65.0 / 80.0
energy CompressedAir: Main = HydraPress-1/CompressedAir
NeEnergyImportHp = 0
NeEnergyExportHp = 0
Volume = 184320
VolumeFlowRate = 18.4
Pressure = 620000
Temperature = 294.65
energy Electricity: Main = HydraPress-1/Electricity
AcActivePowerTotal = 41250
Latest result: stroke-000019
downloaded 42 bytes:
resultId,stroke-000019
peakForceKN,4703.6
Observing MachineryItemState for 4s (OPC 40001-1 state changes always come from the server) …
22:33:52 -> Executing (via FromNotExecutingToExecuting)
22:33:52 -> NotExecuting (via FromExecutingToNotExecuting)
The namespace indices above are whatever the server happened to assign; only
the browse names are stable. 2:Identification and 2:OperationCounters show
up as 13: because OPC 40001-1 gives both the Device Integration namespace —
see Default instance browse names are
load-bearing.
The building blocks come from the OPC 40001-1 MachineryBuildingBlocks
organizer, which is the one place a client can discover what a machine
supports instead of probing for each block in turn. The oil temperature walks a
slow ramp across the datasheet limits, so the exclusive limit alarm on the
process value activates and clears while the sample runs; subscribe to
HydraulicOilTemperature to watch it.
What the sample does not need a second terminal for is the same walk as an
automated test: MachineryEndToEndTests runs this server and this client over
opc.tcp inside the test suite.
See the Machinery developer guide.