fengzero
288175996c
Add plugin cmd function
...
add NEU_REQRESP_GET_SELF_NODE_ID cmd
add get_datatags_table func
define neu_addt_str_t
fix compile warning
add magic number and check function in neu_plugin_common_t
2021-09-02 11:22:51 +08:00
gc87
6872879c22
Add tags operation api
...
Modify modbus-tcp read and write type
2021-08-31 18:41:45 +08:00
fengzero
152302f68b
del macro DEMO, find read/write tag from group config
2021-08-30 18:14:33 +08:00
gc87
ebe450e303
Read and write Modbus driver through MQTT driver
...
1. Add config cmd to neu_manager
2. Modify MQTT driver to read and write
3. Fix modbus response
2021-08-28 16:43:47 +08:00
fengzero
1be8327439
read/write fixed value for demo
2021-08-28 14:15:04 +08:00
fengzero
e09963911d
Add unit test for modbus point
...
sort modbus point for optimizing read efficiency
read modbus point(coil, input, hold reg, input reg)
write modbus point(coil, hold reg)
2021-08-27 17:04:15 +08:00
fengzero
8194e2b2c7
Add write operation for modbus tcp, and process NEU_REQRESP_READ_DATA/NEU_REQRESP_WRITE_DATA
...
NEU_REQRESP_READ_DATA:
interval > 0: just parse modbus point
interval ==0: read modbus point
2021-08-26 15:39:34 +08:00
fengzero
8f72ec0c7e
refactor: modbus tcp read point
...
use point module process modbus point order
remove timerfd epoll
2021-08-25 18:38:39 +08:00
Parker Liu
9c42cdea41
Fix failed build in macOS by remove using epoll
...
The modbus tcp plugin can not work good because we use replace some functions
with empty function.
2021-08-25 16:24:28 +08:00
fengzero
2707499b17
remove tcp epoll, add modbus tcp plugin
...
send/receive data synchronously
2021-08-25 11:38:06 +08:00
fengzero
2abc5a6f27
Add tcp for connecting device and add modbus tcp plugin
...
*use epoll process tcp connection
*define modbus protocol struct and pack function
2021-08-24 11:52:22 +08:00