*** Settings ***
Resource api_http.resource
Resource common.resource
Suite Setup Neuron Context Ready
Suite Teardown Neuron Context Stop
*** Variables ***
*** Test Cases ***
POST ping, status can be ok
Ping
Use the wrong body to create a node, it should return failure
${res} = Add Node type=${${NODE_DRIVER}} namexx=test-node plugin_name=test-plugin-name
Check Response Status ${res} 400
Check Error Code ${res} ${ERR_REQUEST_BODY_INVALID}
Use a plugin name that does not exist to create a node, it should return failure
${res} = Add Node type=${${NODE_DRIVER}} name=test-node plugin_name=test-plugin-name
Check Response Status ${res} 404
Check Error Code ${res} ${ERR_LIBRARY_NOT_FOUND}
Use a invalid node type to create a node, it should return failure
${res} = Add Node type=${10} name=test-node plugin_name=modbus-tcp
Check Response Status ${res} 400
Check Error Code ${res} ${ERR_NODE_TYPE_INVALID}
Create a node with the correct body, it should return success
${res} = Add Node type=${${NODE_DRIVER}} name=test-node plugin_name=modbus-tcp
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}
Create an existing node, it should return failure
${res} = Add Node type=${${NODE_DRIVER}} name=test-node plugin_name=modbus-tcp
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_EXIST}
Get node with wrong parameters, it will return failure
GET /api/v2/node?tt=${NODE_DRIVER}
Integer response status 400
Integer response body error ${ERR_REQUEST_PARAM_INVALID}
Get DRIVER node, it should return all DRIVER node
${res} = Get Nodes ${NODE_DRIVER}
Check Response Status ${res} 200
FOR ${name} IN test-node
Node With Name Should Exist ${res}[nodes] ${name}
END
Get MQTT node, it should return all mqtt node
${res} = Add Node type=${${NODE_APP}} name=mqtt-adapter plugin_name=mqtt
${res} = Get Nodes ${NODE_APP}
Check Response Status ${res} 200
Node With Name Should Exist ${res}[nodes] mqtt-adapter
Get INVALID type node, it should return failure
${res} = Get Nodes ${123456}
Check Response Status ${res} 400
Check Error Code ${res} ${ERR_REQUEST_PARAM_INVALID}
Delete the existing node, it will return success
${res} = Get Nodes ${NODE_DRIVER}
Check Response Status ${res} 200
${node_id} = Get Node By Name ${res}[nodes] test-node
Should Not Be Equal As Integers ${node_id} 0
${res} = Del Node ${node_id}
Check Response Status ${res} 200
${res} = Get Nodes ${NODE_DRIVER}
Check Response Status ${res} 200
${node_id} = Get Node By Name ${res}[nodes] test-node
Should Be Equal As Integers ${node_id} 0
Delete a non-existent node, it will return failure
${res} = Del Node ${1000}
Check Response Status ${res} 404
Check Error Code ${res} ${ERR_NODE_NOT_EXIST}
Add setting to non-existent node, it should return failure
${res} = Node Setting ${999} {"host": "1.1.1.1", "port": 6677, "timeout": 3000}
Check Response Status ${res} 404
Check Error Code ${res} ${ERR_NODE_NOT_EXIST}
Get setting from non-existent node, it should return failure
${res} = Get Node Setting ${999}
Check Response Status ${res} 404
Check Error Code ${res} ${ERR_NODE_NOT_EXIST}
Get setting from a node that has never been set, it should return failure
${driver_node_id} = Add Node And Return ID ${NODE_DRIVER} driver-node ${PLUGIN_MODBUS_TCP}
${res} = Get Node Setting ${driver_node_id}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_NODE_SETTING_NOT_EXIST}
[Teardown] Del Node Check ${driver_node_id}
Add the correct settings to the node, it should return success
${driver_node_id} = Add Node And Return ID ${NODE_DRIVER} driver-node ${PLUGIN_MODBUS_TCP}
${res} = Node Setting ${driver_node_id} {"host": "1.1.1.1", "port": 6677, "timeout": 3000}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}
Get the setting of node, it should return to the previous setting
${driver_node_id} = Get Node ID ${NODE_DRIVER} driver-node
${res} = Get Node Setting ${driver_node_id}
${params} = Set Variable ${res}[params]
Check Response Status ${res} 200
Should Be Equal As Integers ${res}[node_id] ${driver_node_id}
Should Be Equal As Integers ${params}[port] 6677
Should Be Equal As Strings ${params}[host] 1.1.1.1
Should Be Equal As Integers ${params}[timeout] 3000
Add wrong settings to node, it should return failure
${driver_node_id} = Get Node ID ${NODE_DRIVER} driver-node
${res} = Node Setting ${driver_node_id} {"xxhost": "1.1.1.1", "port": 6677, "timeout": 3000}
Check Response Status ${res} 400
Check Error Code ${res} ${ERR_NODE_SETTING_INVALID}
Start an unconfigured node, it should return failure
${modbus_node_id} = Add Node And Return ID ${NODE_DRIVER} modbus-test-node ${PLUGIN_MODBUS_TCP}
Sleep 1s
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_INIT}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_DISCONNECTED}
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_START}
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_NOT_READY}
[Teardown] Del Node Check ${modbus_node_id}
Start the configured node, it should return success
${modbus_node_id} = Add Node And Return ID ${NODE_DRIVER} modbus-test-node ${PLUGIN_MODBUS_TCP}
Sleep 1s
Node Setting ${modbus_node_id} {"host": "127.0.0.1", "port": 502, "timeout": 3000}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_READY}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_START}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_RUNNING}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
Start the stopped node, it should return success
${modbus_node_id} = Get Node ID ${NODE_DRIVER} modbus-test-node
Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_STOP}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_START}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_RUNNING}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
Start the running node, it should return failure
${modbus_node_id} = Get Node ID ${NODE_DRIVER} modbus-test-node
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_START}
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_IS_RUNNING}
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}
Stop node that is stopped, it should return failure
${modbus_node_id} = Get Node ID ${NODE_DRIVER} modbus-test-node
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_IS_STOPED}
[Teardown] Del Node Check ${modbus_node_id}
Stop node that is ready(init/idle), it should return failure
${modbus_node_id} = Add Node And Return ID ${NODE_DRIVER} modbus-test-node ${PLUGIN_MODBUS_TCP}
Sleep 1s
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_NOT_RUNNING}
Node Setting ${modbus_node_id} {"host": "127.0.0.1", "port": 502, "connection_mode": 0}
${res} = Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
Check Response Status ${res} 409
Check Error Code ${res} ${ERR_NODE_NOT_RUNNING}
[Teardown] Del Node Check ${modbus_node_id}
When setting up a READY/RUNNING/STOPED node, the node status will not change
${modbus_node_id} = Add Node And Return ID ${NODE_DRIVER} modbus-test-node ${PLUGIN_MODBUS_TCP}
Sleep 1s
Node Setting ${modbus_node_id} {"host": "127.0.0.1", "port": 502, "timeout": 3000}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_READY}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
Node Setting ${modbus_node_id} {"host": "127.0.0.1", "port": 502, "timeout": 3000}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_READY}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
Node Ctl ${modbus_node_id} ${NODE_CTL_START}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_RUNNING}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
Node Ctl ${modbus_node_id} ${NODE_CTL_STOP}
${running_state} ${link_state} = Get Node State ${modbus_node_id}
Should Be Equal As Integers ${running_state} ${NODE_STATE_STOP}
Should Be Equal As Integers ${link_state} ${NODE_LINK_STATE_CONNECTING}
*** Keywords ***
Neuron Context Ready
Neuron Ready
LOGIN
Neuron Context Stop
Stop Neuron remove_persistence_data=True
Del Node Check
[Arguments] ${node_id}
${res} = Del Node ${node_id}
Check Response Status ${res} 200
Check Error Code ${res} ${ERR_SUCCESS}