# Description

Adds a **Generators companion-specification sample** alongside the
existing pump sample, and a **`SiteCompositionServer`** that composes
several device servers into one OpenUSD scene at a supervisory level —
demonstrating that servers can be aggregated without mirroring their
address spaces.

Three things, in dependency order:

### 1. `GeneratorServer`

A self-contained server realising the draft Generators spec
(`http://opcfoundation.org/UA/Generators/`) end to end: N simulated
generating sets, DI + Machinery integration, a twelve-state operating
state machine, four protection alarms per set, six control methods, and
a per-set OpenUSD twin.

The organising idea is that **load fraction is the only independent
variable**. Everything else is a function of it:

```
V̇_f(x) = 3.67 + 100·x                fuel rate      [L/h]
η(x)   = P(x) / (V̇_f(x) · ρ · LHV)   efficiency
S = P / PF     I = S / (√3·V_LL)     f = N·p / 120
```

This is not stylistic. When each measurement is an independent
oscillator — as the pump sample's simulation once was — a server happily
publishes a duty point no real machine could occupy, and no test can
catch it because there is nothing for the values to be inconsistent
*with*. Deriving them from one variable means `P = √3·V·I·PF` and `η =
P/(V̇·ρ·LHV)` hold at every tick by construction. The published
`DATASHEET.md`, the engineering ranges, the trip points and the
simulation all read the same constants in `GeneratorDatasheet.cs`, so
the document and the server cannot describe different machines.

The machine is a fictitious **SimGen Systems GenX-500** (400 kW prime /
440 kW standby, 400/230 V, 50 Hz, four-pole). Figures are representative
of a real industrial genset class; no vendor is named anywhere in the
code or docs.

### 2. Cross-server composition in the connector

`RemoteSessionFactory` already existed in the client library but the
connector CLI never set it, so cross-server composition was unreachable.
`--federate` wires it up: the connector opens a session to each server
named by a component binding, discovers its representations and drives
its bindings into the same stage.

It is **opt-in** because the endpoint the connector dials comes from the
server being rendered rather than from the operator, which makes
honouring it a trust decision. Federation is best-effort per component —
a subordinate that is down is logged and skipped, and the rest of the
scene still renders — which is the only `src/` change in this PR.

### 3. `SiteCompositionServer`

Owns no devices. It publishes a site stage plus one cross-server
component binding per subordinate, carrying that server's
`ComponentServerUri` and `ComponentEndpointUrl`. Nothing is mirrored, so
there is no cache to invalidate and no second copy of the truth.

## Notes for reviewers

**Everything interesting in this PR was found by running the servers,
not by reading the code.** Six defects, none of which looked wrong in
review:

- `IsShutdown` and `SubsystemName` are *optional* on
`GeneratorProtectionAlarmType`, so the generated factory does not
materialise them. `CreateOrReplace` alone produces a child that exists,
appears in `GetChildren` and holds the right value — but carries **no
`ReferenceTypeId`**, so no browse can reach it. Every alarm was
publishing its trip without saying whether the trip stops the machine or
which subsystem to go to. `AddXxx(context)` first is what gives the
child its `HasProperty` reference.
- **The protections could never fire.** Every trip point sits outside
the band the datasheet curves produce — that is what a datasheet *means*
— so all four alarms, the shutdown class, `ResetFaults` and the whole
`Fault` branch of the state machine were unreachable while the README
documented them as observable. Overload was worse: the load clamp
ceiling was set to exactly the trip point, making a
strictly-greater-than comparison unsatisfiable. Faults are now
injectable, and the first set — the one the hero camera frames —
develops one on a slow rotation.
- **A shutdown trip removes the condition that caused it**, because oil
pressure and coolant temperature are only supervised while the engine
turns. Each alarm went active for one tick and cleared, leaving an
operator with a stopped machine and no indication of why. Shutdown-class
alarms now latch until the set leaves the shutdown state. Every unit
test that checked the *condition* passed throughout — the defect only
appears when the trip and the supervision interact over time.
- **`Synchronizing` and `Paralleled` were declared, drawn in the README
and never entered.** The first set now energises a dead bus and closes
onto it while every other set synchronises to a live one — both how a
real plant parallels, and what makes the two states observable.
- **The tick raced client method calls.** The simulation tick runs on a
thread-pool thread while method calls arrive on request threads, and
both transition sets and write the same nodes. A tick moving a set to
`Cooldown` and a concurrent `EmergencyStop` could interleave the paired
`CurrentState` / `CurrentState.Id` writes and leave a client with a
state *name* from one transition and a state *node* from the other — the
exact failure the paired write exists to prevent, reintroduced by the
threading model. Both paths now take one gate.
- Low oil pressure supervised from raw speed **tripped every set during
cranking**, because pressure has not built yet. Now gated on
`IsSpinning`, which is what a real start-up bypass does.

Smaller fixes: shutdown trips are applied after the whole evaluation
pass (stopping mid-loop made the remaining conditions read healthy,
collapsing simultaneous trips to whichever came first in the table);
`ResetFaults` reports its clears as events (a client learns of condition
state changes only through events, so a silent clear leaves an
alarm-list client showing it forever); the start counter moved into the
transition so commanded starts are counted; the federated connector
closes the remote session if the connector constructor throws between
taking ownership and registering it; and `prepare_machinery_nodeset.py`
now *asserts* the IA namespace is last before removing it rather than
only claiming so in its docstring — removing any earlier entry would
silently renumber every namespace after it and rebind their NodeIds.

**A model limitation is left visible rather than papered over.**
`GeneratorStateMachineType` declares an emergency stop only out of
`Running`, `Loaded` and `Paralleled`, so the sample refuses
`EmergencyStop` from `Starting` and `Warmup`. A real panel stops from
anywhere. That is the specification's shape, not this sample's choice,
so it is pinned by a test and named in the docs.

**`Model/` vendors a reduced Machinery nodeset**, derived mechanically
by whitelist. The full official nodeset does not survive the model
source generator (`MODELGEN003`) and drags in IA through a single
optional `Stacklight` member a generating set does not have. Deriving it
by script keeps the provenance checkable; the whitelist is the only
thing to edit when more types are needed. **Never hand-edit the
generated output.**

**The federated scene renders end to end.** Getting there surfaced three
more defects, all of which produced a plausible-looking scene with
nothing in it: the generator sample's plant aggregation was created
under an already-registered `DeviceSet` and so was invisible to every
client (it had *never* rendered geometry, standalone or federated); the
connector's asset fetch ran on the primary session only, so composition
referenced layers that were never downloaded; and both generator colour
bindings wrote `primvars:displayColor` to prims that did not declare it,
so the renderer rejected every update while the file still looked
correct. Cross-server components compose under the subordinate's own
root, so the site layer now *places* `/Plant` and `/Powerhouse` rather
than leaving them stacked on the origin.

**`OpenUsdRepresentation` is now mounted with `HasAddIn`, not
`HasComponent`** (review feedback). The nodeset says so explicitly —
*"Mounted with HasAddIn"* — but every server in the tree used plain
`HasComponent`. It survived because `HasAddIn` is a *subtype* of
`HasComponent`: the representation still browses, still aggregates and
still drives a twin, so every functional test passed before the fix and
after it, and only a conformance checker could tell. Seven mount sites
corrected. `PumpDeviceIntegrationServer` and `MinimalRobotServer` had
hand-rolled the mount instead of calling the shared
`CreateRepresentation` helper, which is exactly how they drifted from
it. Both sample E2E suites now assert the reference type across
**every** discovered representation — a narrower check would have missed
the plant-level representation that arrived later from master still
carrying `HasComponent`.

**Live colour is not achievable in the current OpenUSD viewer, and that
is now documented rather than worked around.** Proven with a standalone
probe: `primvars:displayColor` resolves as `color3f[]` from the
`UsdGeomGprim` schema whatever the layer declares, and the `OpenUsd
0.4.0-alpha` managed API has no writer for that type. Bound
`UsdPreviewSurface` materials are not shaded either, so geometry renders
grey unless it also carries an explicit `displayColor` primvar. The
**visibility** bindings carry no such caveat and are what the samples
rely on to show state. Filed upstream as
[openusd-dotnet#2](https://github.com/marcschier/openusd-dotnet/issues/2),
[#3](https://github.com/marcschier/openusd-dotnet/issues/3) and
[#4](https://github.com/marcschier/openusd-dotnet/issues/4), and linked
from `docs/OpenUsd.md` so a reader can check whether they have since
been fixed.

## Related Issues

No tracking issue — this is additive sample and documentation work with
a single small, self-contained change to `src/` (per-component error
isolation and session-ownership hardening in
`OpenUsdConnector.Composition.cs`). Happy to open one if maintainers
would prefer it tracked.

## Checklist

- [x] I have signed the
[CLA](https://opcfoundation.org/license/cla/ContributorLicenseAgreementv1.0.pdf)
and read the
[CONTRIBUTING](https://github.com/OPCFoundation/UA-.NETStandard/blob/master/CONTRIBUTING.md)
doc.
- [x] I have added tests that prove my fix is effective or that my
feature works and increased code coverage.
- [x] I have added all necessary documentation.
- [x] I have verified that my changes do not introduce (new) build or
analyzer warnings.
- [x] I ran **all** tests locally using the **UA.slnx** solution against
at least .net **framework** and .net **10**, and all passed.
- [ ] I fixed **all** failing and flaky tests in the CI pipelines and
**all** CodeQL warnings.
- [ ] I have addressed **all** PR feedback received.

### Testing

The generator fixtures live in `tests/Opc.Ua.OpenUsd.Tests/Generator` —
**82 tests**, no new project. `Opc.Ua.Di.Tests` would have been the
natural home next to the pump fixtures, but both device samples
source-generate their own reduced `Opc.Ua.Machinery` model and expose it
via `InternalsVisibleTo`, so referencing both from one assembly makes
every Machinery type ambiguous (CS0433); `Opc.Ua.OpenUsd.Tests`
references no other sample and already hosts `RobotAssetContractTests`.
The suite runs **870** on net10.0 and net48 (784 existing + 86) and
**788** on net472, where the sample does not exist and only the
framework-independent asset-contract tests run — forgetting exactly that
exclusion broke CI on the sibling pump PR.

The tests target the things in this sample that fail *quietly*:

- **Datasheet conformance** holds the model to its own claim — rated
speed is `120·f/p`, rated current follows from the rating, the fuel
curve reproduces the published table, and `η = P/(V̇·ρ·LHV)` reconciles
at every load. Efficiency is swept across the whole simulated range to
show it stays inside (0,100) and rises monotonically; a fit that goes
negative somewhere in its range is a coincidence that happens to look
right at the duty point, not a model. A further test reads
`DATASHEET.md` and checks the document quotes the figures the server
actually serves.
- **Drift between the two descriptions of the state machine** — the
physics' `IsLegalTransition` and the model's `GeneratorStateMap` — is
checked in *both* directions. A transition the physics permits but the
map lacks moves a machine without telling a client; one the map holds
but the physics refuses is dead weight that looks supported.
- **Reachability at run time**, not just in the declared table — the
test that catches states the model declares and nothing ever enters.
- **That every protection can actually fire**, which is the half of the
alarm contract that "a healthy set annunciates nothing" does not cover.

A **hosted end-to-end fixture** connects a real client and asserts what
the address space actually exposes — the aggregation at
`/Powerhouse/Generators`, its component binding, and every per-set twin.
That is the only kind of test that catches the registration defect
above: the node object had the right browse name, binding and asset
reference, so every test that inspected objects passed while no client
could see it.

**Every state-machine and protection fix was checked by mutation.**
Restoring the clamp ceiling, the direct `Running → Loaded` path, the old
start-counter placement, or removing the alarm opt-in each makes the
corresponding test fail, naming the specific defect. A test that has
never been seen to fail has not been shown to work.

Verified against a running plant: `Synchronizing`, `Paralleled` and
`Fault` all observed on a two-set server, with
`HighCoolantTemperatureAlarm` seen active on the fault subject. Method
behaviour verified separately — per-set distinct `CurrentState` nodes,
`EmergencyStop` → `EmergencyStopped` with `Start` then refused as
`BadInvalidState`, `ResetFaults` → `Off`, `SetOperatingMode(9999)`
refused with the mode unchanged, and the other sets untouched
throughout. Also verified as a three-server federated stage.

0 warnings on a clean Release rebuild of both samples, the client
library, the connector and the tests, across every TFM.

---------

Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Copilot-Session: fe608993-f3c9-4779-a6b9-9a9eabfc24ba
2026-08-07 10:48:02 +02:00

11 KiB
Raw Permalink Blame History

Generators (generating sets)

The draft Generators companion specification (http://opcfoundation.org/UA/Generators/) realised end to end by GeneratorServer, and composed with the pump sample by SiteCompositionServer.

The model

A generating set is two things at once: an asset with a nameplate and a health, and a machine whose core is an engine coupled to an alternator. The specification layers on existing building blocks rather than reinventing them:

Layer Role
DI (OPC 10000-100) GeneratorSetType derives from DeviceType, inheriting the nameplate and DeviceHealth; each subsystem derives from ComponentType
Machinery (OPC 40001-1) Identification add-in and the MachineryItemState / MachineryOperationMode building blocks
Part 9 GeneratorProtectionAlarmType, a subtype of OffNormalAlarmType
Part 16 GeneratorStateMachineType, a twelve-state FiniteStateMachineType

Composition over deep inheritance: subsystems are separate ComponentType subtypes referenced by HasComponent, so a set is assembled from exactly the components it has.

Source generation

The sample generates the model locally from vendored NodeSet2 files rather than referencing a library:

<AdditionalFiles Include="Model\Opc.Ua.Generators.NodeSet2.xml">
  <ModelSourceGeneratorPrefix>Opc.Ua.Generators</ModelSourceGeneratorPrefix>
</AdditionalFiles>
<AdditionalFiles Include="Model\Opc.Ua.Generators.NodeSet2.csv" />

The CSV alongside each XML is the stable NodeId table. Without it the generator assigns synthetic NodeIds at compile time, which breaks byte-stable wire formats for clients that cache NodeIds across builds.

The Machinery dependency

The specification composes three Machinery types — MachineryItemState_StateMachineType, MachineryOperationModeStateMachineType and MachineIdentificationType — that the reduced Machinery nodeset carried by the pump sample does not define. The full official nodeset defines them but does not survive the model source generator (it fails with MODELGEN003), and it declares a dependency on the IA namespace through a single optional Stacklight member that a generating set does not have.

Model/prepare_machinery_nodeset.py therefore derives a reduced-but-sufficient set from the official nodeset by whitelist, strips the references left dangling and drops the IA dependency. Deriving it mechanically keeps the provenance checkable, and the whitelist is the only thing to edit when more types are needed.

Removing the IA URI is index-safe because it is the last entry in NamespaceUris, so the Machinery (1) and DI (2) indices used throughout the file do not move.

Simulation design

The sample's organising idea is that load fraction is the only independent variable. Everything else is a function of it:

V̇_f(x) = 3.67 + 100·x                      fuel rate       [L/h]
η(x)   = P(x) / (V̇_f(x) · ρ · LHV)         efficiency
S      = P / PF                            apparent power  [VA]
I      = S / (√3 · V_LL)                   line current    [A]
f      = N · p / 120                       frequency       [Hz]

This is not a stylistic choice. When each measurement is an independent oscillator — as the pump sample's simulation once was — a server happily publishes a duty point that no real machine could occupy, and no test can catch it because there is nothing for the values to be inconsistent with. Deriving them from one variable means P = √3·V·I·PF and η = P/(V̇·ρ·LHV) hold at every tick by construction, and GeneratorDatasheetConformanceTests asserts exactly that.

The published datasheet, the engineering ranges, the trip points and the simulation all read the same constants, so they cannot drift apart.

Control surfaces

The specification defines three ways to observe and command a set, and all three are driven from the same decider: the simulation's operating state. This is the design point worth copying. A state machine advanced independently of the physics that produced it will eventually report a machine as running while the simulation says it is stopped — and because both halves are internally consistent, nothing at run time notices.

GeneratorStateMachineType

Twelve states and twenty-two declared transitions, mandatory on the type. Because the node already exists, the sample attaches behaviour to it in lifecycle mode (StateMachineBuilder.For(machine, context)) rather than defining states — see State machines.

The simulation raises a transition callback; the address space follows it. Both CurrentState and its Id property are written, because a client that receives a state name it cannot resolve to a state node is no better off than one that received nothing.

The state and transition number tables are deliberately kept apart from the node manager, in GeneratorStateMap, and a test holds them against the simulation's own legality function in both directions: a transition the physics permits but the map lacks moves a machine without telling a client; one the map holds but the physics refuses is dead weight that looks supported.

GeneratorProtectionAlarmType

One instance per protection function rather than a single instance whose ProtectionFunction changes. A set can trip on low oil pressure and overspeed in the same moment, and collapsing them loses the second; it is also how a real control panel annunciates.

Because OffNormalAlarmType takes healthy as the normal state, each instance carries InputNode pointing at the variable it supervises. Without it a client can see that something tripped but not what was being watched.

Optional members must be opted into. ProtectionFunction is mandatory on the type and is materialised by the generated factory; IsShutdown and SubsystemName are optional and are not. Writing to an optional member with CreateOrReplace alone produces a child that exists, appears in GetChildren and holds the value — but carries no ReferenceTypeId, so no browse can reach it and the property is absent from a client's view. Call AddXxx(context) before writing. The failure is silent in both directions: the code looks right, and the server answers reads on everything it does publish, so only a client comparing against the type definition notices.

A simulation that cannot leave its healthy band cannot exercise its protections. The datasheet curves are bounded inside every trip point by construction, so a faithful simulation of a healthy machine leaves the entire protection path — alarms, shutdown class, ResetFaults, the Fault branch of the state machine — as dead code, while the documentation describes it as working. The sample therefore injects a deviation into the measurement rather than the curve, which is what a real fault is, and rotates it so a long run exercises every protection. The lesson generalises: when the model says a thing cannot happen, the code that handles it needs a deliberate way to be reached, or it is untested.

Trip after evaluating, not during. Stopping the set inside the evaluation loop makes its remaining conditions read healthy, so simultaneous trips collapse to whichever protection came first in the table — defeating the reason for having one alarm instance per function.

A shutdown protection must latch. The trip removes the condition that caused it, because the supervised quantities are only meaningful while the machine runs. An alarm that tracks its input therefore annunciates for one tick and clears, which tells an operator that something stopped the set but not what. Latch until the set leaves the shutdown state. This one is easy to miss in review and in unit tests — the condition logic is correct in isolation; the defect only appears when the trip and the supervision interact over time.

Clearing is an event, not just a state change. A client learns of condition state changes only through events. Clearing an alarm node without reporting leaves an alarm-list client displaying it as active and retained until a ConditionRefresh.

Trip conditions read the hysteresis the simulation already applies, so alarms latch and clear cleanly rather than chattering on the threshold, and events are reported only on change. A shutdown-class trip stops the machine; a warning does not — reporting a trip without stopping the set would publish a generator that is on fire and still loaded.

One trap worth naming: supervising low oil pressure during cranking trips every set the moment it tries to start, because pressure has not built yet. Real sets bypass that trip for exactly this reason.

Methods

Legality is decided in exactly one place, so no caller can drive a machine from Off straight to Loaded by picking the right method. A refused request answers BadInvalidState rather than silently doing nothing — a method that appears to succeed without acting is indistinguishable from a real success, which is worse than an honest refusal.

The method semantics are expressed against the simulation rather than against address-space nodes, which keeps each handler down to one line and lets the behaviour be tested without standing up a server.

Concurrency

The simulation tick runs on a thread-pool thread while client requests are served on their own threads, and both drive state transitions and write the same address-space nodes. They are serialised by a single gate held across the whole tick and across every method handler.

This matters more than it looks. Without it, a tick moving a set to Cooldown and a concurrent EmergencyStop both fire the state-change callback, and the paired CurrentState / CurrentState.Id writes interleave — leaving a client with a state name from one transition and a state node from the other. That is the precise failure the paired write exists to prevent, reintroduced by the threading model rather than by the write itself. One gate for the whole plant rather than one per set: a tick is microseconds of arithmetic, so the contention is irrelevant, and a single gate cannot be acquired in the wrong order.

Cross-server composition

SiteCompositionServer demonstrates composing several servers at a supervisory level. It owns no devices; it publishes a site stage and one cross-server component binding per subordinate, carrying that server's ComponentServerUri and ComponentEndpointUrl:

Opc.Ua.OpenUsd.Connector --server <site> --federate --view

With --federate the connector opens a session to each named server, discovers its representations and drives its bindings into the same stage — one scene, live machines, three servers.

Nothing is mirrored. The site server never proxies a subordinate's address space, so there is no cache to invalidate and no second copy of the truth.

--federate is opt-in because the endpoint the connector dials comes from the server being rendered rather than from the operator, which makes honouring it a trust decision. Federation is also best-effort per component: a subordinate that is down is logged and skipped, and the rest of the scene still renders.